• Title/Summary/Keyword: analyzer

Search Result 4,506, Processing Time 0.031 seconds

Chemical Age Dating of Zircon and Monazite by E1ectron Microprobe (전자현미분석기를 이용한 저어콘 및 모나자이트의 화학적 연대 측정법)

  • 이석훈
    • The Journal of the Petrological Society of Korea
    • /
    • v.10 no.3
    • /
    • pp.179-189
    • /
    • 2001
  • The determination of trace concentration of U, Th and Pb was carried out for chemical dating of zircon and monazite by electron microprobe. Detection limit and error range should be considered to measure characteristic X-rays of M-line from those minerals, which are low in the ionization of atom and low peak intensity in the spectrum. The element of U, Th and Pb were simultaneously measured with 3 spectrometers equipped with PET crystal to reduce a total counting time and error due to drift of instrumental operating condition. Detection limit could be improved from increase of the peak/background ratio through adjusting pulse height analyzer about 1000 mv baseline. Under permissible maximum analytical conditions, theoretical detection limit of U, Th and Pb is down to 30 ppm (99% confidence level). The analytical result was maintained at a relative error $\pm$10% ($2{\sigma}$) in 800 ppm Pb, $\pm$5% ($2{\sigma}$) in 2330 ppm U and $\pm$10% ($2{\sigma}$) in dating from a single measurement of zircon at 15 keV and 100 nA. However, for the precise dating of zircon and monazite, if it is considered a 3 $\mu\textrm{m}$ spatial resolution, <100 ppm ($3{\sigma}$) detection limit and <$\pm$10% ($2{\sigma}$) relative error, optimum analytical conditions are given as 15~20 keV accelerating voltage, 100~200 nA beam current and 300~1200 sec total counting time. To reduce material damage by high current, there is need to be up to 3~5 $\mu\textrm{m}$ of electron beam diameter, or to use arithmetic average of multiple measuring at a shorter counting time. A younger or relatively low concentration rocks can be dated chemically by lower detection limit and improved precision resulted from increase of current and measuring time.

  • PDF

Major Characteristics Related on Eating Quality and Classification of Inbred Lines of Waxy Corn (찰옥수수 자식계통 식미관련 특성 및 계통 분류)

  • Jung Tae-Wook;Kim Sun-Lim;Moon Hyeon-Gui;Son Beom-Young;Kim Si Ju;Kim Soon Kwon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.50 no.spc1
    • /
    • pp.161-166
    • /
    • 2005
  • Objectives of this study were to select inbred lines which have a good eating quality and desirable segregates during inbreeding of waxy corn. The 64 inbred lines showed a large variance in their kernel shape and weight. 100-kernel weight, pericarp thickness, kernel length, kernel width, and kernel thickness ranged $11.7\~37.3g,\;11\~77{\mu}m,\;5.8\~9.6mm,\;6.5\~10.0mm$, and $4.1\~6.8mm$, respectively. The physicochemical analysis of 64 waxy corn inbred lines showed crude protein, crude fat, free sugar, and amylopectin content ranging $8.7\~15.8\%,\;2.3\~5.8\%,\;1.1\~11.0\%,\;and\;78.5\~93.8\%$, respectively. The texture property analysis of 64 inbred lines by texture analyzer showed a big difference. Gumminess, hardness, and chewiness of 64 inbred lines ranged $91\~383,\;181\~394,\;and\;73\~370$, respectively. The principal component analysis for 14 characteristics related to kernel quality showed that $73.1\%$ of the total variation could be attributed to the first five principal components. Biological meaning of the principal component was explained clearly by the correlation coefficient between principal components and characters. The first principal component appeared to correspond to small kernel and bad eating quality, The second principal component appeared to correspond to large kernel and good eating quality. The 64 inbred lines were classified into 8 groups by the cluster analysis using the first and second principal component. Among the groups, group VII and VIII included inbred lines with good eating quality that had thin pericarp thickness, low protein content, large kernel, and soft tenderness.

Quality characteristics of domestic and imported commercial plain wheat flour (시판 우리밀과 수입밀 중력 밀가루의 품질 특성 비교)

  • Kwak, Han Sub;Kim, Mi Jeong;Kim, Hoon;Kim, Sang Sook
    • Korean Journal of Food Science and Technology
    • /
    • v.49 no.3
    • /
    • pp.304-310
    • /
    • 2017
  • The aim of this study was to compare the physicochemical properties of domestic and imported commercial plain wheat flour and dough. Four types of domestic wheat flour (DW; DW1-4) were compared to four types of imported wheat flour (IW; IW1-4). DWs exhibited lower moisture content, lightness (L), and whiteness, and higher protein content, redness (a), and yellowness (b), than those exhibited by IWs. Solvent retention capacity of DWs and IWs was similar; however, DWs showed higher gluten performance index. Pasting properties, analyzed by rapid visco analyzer (RVA), were similar for DW1, DW2, and IWs; however, DW3 and DW4 showed different RVA patterns. Considering that DW3 and DW4 were organic wheat flour, possible incorporation of damaged kernel might increase amylase activities resulting in decreased peak viscosity. Dough resistance (108.4-159.9 g) and extensibility (11.8-16.7 mm) of IWs were higher than those of DWs (78.0-118.7 g, 8.7-12.5 mm, respectively).

Effects of Cobalt-60 Gamma Ray Irradiation on Blood Cells and Enzyme Activity of Albino Rats (코발트-60 감마선(線) 조사(照射)가 흰쥐의 혈액성분(血液成分) 및 수종(數種) 효소(酵素)의 활성(活性)에 미치는 영향(影響))

  • Lee, Sang-Suk
    • Journal of radiological science and technology
    • /
    • v.8 no.2
    • /
    • pp.47-63
    • /
    • 1985
  • This paper was aimed to study the effects of Cobalt-60 gamma ray irradiation on Albino rat blood cells and the activity of enzymes were measured using blood cell auto analyzer (Cell-Dyn 900) and enzyme autoanalyzer (Gilford 3500) respectively. Cobalt-60 gamma rays those are grouped into 200R, 400R, 600R, 800R, 1,000R, 1,200R, 1,300R, 1,400R, 1,500R and 1,600R to the rats of male and female and measured the numeral varieties of blood corpuscles of the rats and the active varieties of enzyme of acid, alkaline phosphatase (ACP, ALP), lactic acid dehydrogenase (LDH), glutamic oxaloacetic transaminase (GOT) and glutamic pyruvic transaminase. (GPT) those came out after 1, 3, 5 or 7 days. The results are summarized as follows: 1. In both case of male and female, the numeral varieties of the erythrocytes, in the 200R group of irradiation showed the minimum value in the 3 days group and a tendency of increase in the 5 and 7 days groups, while the numeral varieties of the leucocytes in every groups of irradiation showed a tendency of a rapid decrease after a day. The numeral varieties of the blood platelet in both case of male and female didn't show generally any great change in a day and 3 days groups, but showed a rapid decreasing appearance after the 5 days. 2. In both case of male and female, the activities of ACP were on the decrease gradually after 3 days of the irradiation and the activities of ALP were on the decrease after 5 days. Similarly in both case of mate and female, the activities of LDH showed the decrease after 3 and 5 days, and the phenomenous of GOT showed an appearance of increase in a day, but decreased after 3 days. As for the GPT activities couldn't find any great change in the male rats in comparison with the control groups, but in the female rats a tendency of the increase in 600R, 800R, 1,000R groups after 3 days. 3. In the case of the irradiation of high quantity of ray more than 1,200R, all rats died after 4 days, and by the irradiation of 1,600R all rats died after 3 days, and it showed the sensitive response of a living body to the irradiation of high quantity.

  • PDF

Evaluation on the Usefulness of Filter in Sentinel Lymphoscintigraphy Using $^{99m}Tc$-Phytate (Phytate를 이용한 감시림프절 검사 시 Filter의 유용성 평가)

  • Jeong, Yeong-Hwan;Seo, Han-Kyung;Shim, Cheol-Min;Lim, Seong-Dong;Han, Dong-Hyeon;Park, Yung-Sun;Kim, Dong-Yun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.35-39
    • /
    • 2010
  • Purpose: The aim of this study was to investigate distribution of particle size in phytate kit and compare filtered method with non-filtered method using 200 nm filter for sentinel lymphoscintigraphy (SLS). Materials and Methods: Five phytate kit of having the same available period was measured by particle size analyzer. For in-vivo experiment, $^{99m}Tc$-phytate was injected intradermally at both foot to perform lymphoscintigraphy. Imaging was acquired at 1hour after injection. Region of interest (ROI) was drawn in inguinal and background area for analysis. RAW 264.7 cells (Murine macrophage cell) were prepared for measurement of celluar uptake as a representative of macrophages. Paired t-test was performed using SPSS (SPSS Inc, USA) for statistical analysis. Results: The size of most particle in Techne phytate kit was distributed in 130~650 nm(90.5 %). In-vivo study, the ROI analysis showed similar result between filtered and non-filtered sample, and the numerical value of count/pixel were $58.3{\pm}5.97$ and $60.2{\pm}4.88$. In-vitro study, cellular uptake study also showed no difference between filtered and non-filtered sample by gamma counting. Conclusion: The present study demonstrates that there was no meaning of 200 nm filtered method for SLS using $^{99m}Tc$-phytate.

  • PDF

The Effect of Epigallocatechin-3-gallate on HIF-1 α and VEGF in Human Lung Cancer Cell Line (비소세포폐암주에서 저산소상태에 의해 유발된 HIFa-1 α와 VEGF의 발현증가에 미치는 Epigallocatechin-3-gallate의 억제 효과)

  • Song, Joo Han;Jeon, Eun Joo;Kwak, Hee Won;Lee, Hye Min;Cho, Sung Gun;Kang, Hyung Koo;Park, Sung Woon;Lee, Jae Hee;Lee, Byung Ook;Jung, Jae Woo;Choi, Jae Cheol;Shin, Jong Wook;Kim, Ki Jeong;Kim, Jae-Yeol;Park, In Won;Choi, Byoung Whui
    • Tuberculosis and Respiratory Diseases
    • /
    • v.66 no.3
    • /
    • pp.178-185
    • /
    • 2009
  • Background: Epigallocatechin-3-gallate (EGCG) is the major catechin in green tea, and has shown antiproliferative, antiangiogenic, antimetastatic and cell cycle pertubation activity in various tumor models. Hypoxia can be induced because angiogenesis is insufficient for highly proliferating cancer. Hypoxia-inducible factor-1$\alpha$ (HIF-1$\alpha$) and its downstream target, vascular endothelial growth factor (VEGF), are important for angiogenesis, tumor growth and metastasis. The aim of this study was to determine how hypoxia could cause changes in the cellular phenomena and microenvironment in a non-small cell culture system and to examine the effects of EGCG on a HIF-1$\alpha$ and VEGF in A549 cell line. Methods: A549 cells, a non-small cell lung cancer cell line, were cultured with DMEM and 10% fetal bovine serum. A decrease in oxygen tension was induced using a hypoxia microchamber and a $CO_2-N_2$ gas mixture. Gas analysis and a MTT assay were performed. The A549 cells were treated with EGCG (0, 12.5, 25, 50 ${\mu}mol/L$), and then examined by real-time-PCR analysis of HIF-1$\alpha$, VEGF, and $\beta$-actin mRNA. Results: Hypoxia reduced the proliferation of A549 cells from normoxic conditions. EGCG inhibited HIF-1$\alpha$ transcription in A549 cells in a dose-dependent manner. Compared to HIF-1$\alpha$, VEGF was not inhibited by EGCG. Conclusion: HIF-1$\alpha$ can be inhibited by EGCG. This suggests that targeting HIF-1$\alpha$ with a EGCG treatment may have therapeutic potential in non-small cell lung cancers.

Contents of Total and Organic Mercury in Bone, Muscle and Fin of Carassius carassius Middle Steam of Nakdong River, Korea (낙동강 본류에 서식하는 붕어에서의 총수은 및 유기수은 함량)

  • Choi, Young;Kim, Doo-Hie
    • Journal of agricultural medicine and community health
    • /
    • v.18 no.2
    • /
    • pp.131-140
    • /
    • 1993
  • This study was conducted to examine the levels of mercury in tissue of Carassius carassius collected at five areas(Andong, Sangju, Waekwan, Gangjung and Gaejin) in Nakdong river from February to March, 1993. The contents of total and organic mercury were determined by methods of Gold amalgam and Selective atomic absorption with mercury analyzer(Model SP-3A). The total mercury contents in muscle were $0.148{\pm}0.0646$ ppm by the Gold amalgam, and $0.113{\pm}0.0345$ ppm by the Selective atomic absorption, but in all parts of Carassius carassius were $0.342{\pm}0.4235$ ppm and $0.240{\pm}0.2974$ ppm respectively. These two methods were extremely high correlated(r=0.9812, p<0.001). The mean value of total and organic mercury by the two methods was high in the order of bone>fin>muscle, respectively, and the proportion of organic mercury to the total was 69.0%. Mean value of total and organic mercury in the muscle was the highest at Wakeman located in middle basin of Nakdong river, and in the bone and fin was the highest at Andong dam located in upper basin. According to sizes and parts of fish, the concentration of mercury was the highest in the muscle of 15-19 cm group, the highest in the bone of 10-14 cm group and in the fin of 20-24 cm group.

  • PDF

Timing Driven Analytic Placement for FPGAs (타이밍 구동 FPGA 분석적 배치)

  • Kim, Kyosun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.7
    • /
    • pp.21-28
    • /
    • 2017
  • Practical models for FPGA architectures which include performance- and/or density-enhancing components such as carry chains, wide function multiplexers, and memory/multiplier blocks are being applied to academic FPGA placement tools which used to rely on simple imaginary models. Previously the techniques such as pre-packing and multi-layer density analysis are proposed to remedy issues related to such practical models, and the wire length is effectively minimized during initial analytic placement. Since timing should be optimized rather than wire length, most previous work takes into account the timing constraints. However, instead of the initial analytic placement, the timing-driven techniques are mostly applied to subsequent steps such as placement legalization and iterative improvement. This paper incorporates the timing driven techniques, which check if the placement meets the timing constraints given in the standard SDC format, and minimize the detected violations, with the existing analytic placer which implements pre-packing and multi-layer density analysis. First of all, a static timing analyzer has been used to check the timing of the wire-length minimized placement results. In order to minimize the detected violations, a function to minimize the largest arrival time at end points is added to the objective function of the analytic placer. Since each clock has a different period, the function is proposed to be evaluated for each clock, and added to the objective function. Since this function can unnecessarily reduce the unviolated paths, a new function which calculates and minimizes the largest negative slack at end points is also proposed, and compared. Since the existing legalization which is non-timing driven is used before the timing analysis, any improvement on timing is entirely due to the functions added to the objective function. The experiments on twelve industrial examples show that the minimum arrival time function improves the worst negative slack by 15% on average whereas the minimum worst negative slack function improves the negative slacks by additional 6% on average.

Compact Orthomode Transducer for Field Experiments of Radar Backscatter at L-band (L-밴드 대역 레이더 후방 산란 측정용 소형 직교 모드 변환기)

  • Hwang, Ji-Hwan;Kwon, Soon-Gu;Joo, Jeong-Myeong;Oh, Yi-Sok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.7
    • /
    • pp.711-719
    • /
    • 2011
  • A study of miniaturization of an L-band orthomode transducer(OMT) for field experiments of radar backscatter is presented in this paper. The proposed OMT is not required the additional waveguide taper structures to connect with a standard adaptor by the newly designed junction structure which bases on a waveguide taper. Total length of the OMT for L-band is about 1.2 ${\lambda}_o$(310 mm) and it's a size of 60 % of the existing OMTs. And, to increase the matching and isolation performances of each polarization, two conducting posts are inserted. The bandwidth of 420 MHz and the isolation level of about 40 dB are measured in the operating frequency. The L-band scatterometer consisting of the manufactured OMT, a horn-antenna and network analyzer(Agilent 8753E) was used STCT and 2DTST to analysis the measurement accuracy of radar backscatter. The full-polarimetric RCSs of test-target, 55 cm trihedral corner reflector, measured by the calibrated scatterometer have errors of -0.2 dB and 0.25 dB for vv-/hh-polarization, respectively. The effective isolation level is about 35.8 dB in the operating frequency. Then, the horn-antenna used to measure has the length of 300 mm, the aperture size of $450{\times}450\;mm^2$, and HPBWs of $29.5^{\circ}$ and $36.5^{\circ}$ on the principle E-/H-planes.

Effect of Mouthguard on Tooth Distortion During Clenching (이악물기 시 발생되는 치아변형에 대한 구강보호장치의 역할)

  • Lee, Yun;Choi, Dae-Gyun;Kwon, Kung-Rock;Lee, Richard Sung-Bok;Noh, Kwan-Tae
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.4
    • /
    • pp.405-417
    • /
    • 2010
  • Previous studies have already shown that mouthguard is effective in protecting jaw bone, teeth and oral tissue against sports trauma. However, other than severe trauma, repetitive force, such as disorders like clenching, cause teeth or oral tissue damage. These kinds of disorders usually present pathologic attrition in the posterior teeth, resorption in alveolar bone, loss of teeth and destruction of occlusion. Wearing a mouthguard is believed to be effective in preventing these disorders. But its effect is not examined thoroughly enough. The purpose of this study is to identify whether mouthguard is effective in reducing strain caused by clenching. Mandibular first molars in the normal occlusal relationship without any history of dental treatment were chosen. Biaxial type strain gauge was placed on the buccal surface of the tooth. Having maximum occlusal force, measured by load cell, as a standard, clenching intensity were divided into three stages; moment of slightly tooth contact, medium bite force (50% of maximum bite force), maximum bite force. Strain occurring in dentition in each stage with and without mouthguard was measured. Changes in strain (on dentition) between each stage and difference in strain, between with or without mouthguard were recorded by PCD-300 analyzer and PCD-30 soft ware. The data was statistically analyzed by Wilcoxon signed rank test. The following results were drawn; Without mouthguard, strain given on dentition increased as the clenching force increased. With mouthguard, strain given on dentition also increased as the clenching force increased. With mouthguard, strain decreased, in all cases of clenching force stages. Data on the moment of slightly tooth contact stage, had no statistical significance. However, with mouthguard, 50-90% of decrease in strain could be obtained in maximum occlusal force, compared to the group without mouthguard. Mouthguard decreased the strain on the dentition, caused by clenching. Therefore, mouthguard seems to be effective in preventing damage on dentition, by acting against clenching, which occurs both consciously and unconsciously during sports activities.