• Title/Summary/Keyword: air oxidation

Search Result 952, Processing Time 0.025 seconds

Electrochemical Properties of Pyrrole/Thiophene Polymer Composite (피롤/티오펜 고분자 복합체의 전기화학적 성질)

  • Cha, Seong Keuck;Choi, Kyu Seong;Ahn, Byuong Kee;Kang, Sang Jin
    • Journal of the Korean Chemical Society
    • /
    • v.40 no.7
    • /
    • pp.467-473
    • /
    • 1996
  • Although a polypyrrole shows better electrical conductivity, 100∼400 ${\Omega}^{-1}cm^{-1}$, than other organic conducting polymers, its electrical conductivity will be worsen in the presence of the oxygen due to its easy oxidation. On the other hand, polythiophene shows better stability in the air while its electrcal conductivity is poor compared to the polypyrrole. We succeed to develope the mixed polymer electrode that is stable in the air and shows a good redox characteristics. The mixed polymer electrode has been prepared by the electrical polymerization of polypyrrole on the Pt electrode as 1.70 C$cm^{-2}$ and then coating with polythiophene as 0.34 C$cm^{-2}$. The polymerization rate of polythiophene was $3.89{\times}10^{-8}$ at the bare Pt electrode and $6.07{\times}10^{-8}cms^{-1}$ at the mixed polymer electrode. And the standard rate constants of each electrode were $5.16{\times}10^{-6}\;and\;3.94{\times}10^{-4} cms^{-1}$ respectively. Also, the electrocatalytic rate of the polypyrrole polymer electrode was $3.45{\times}10^{-3}cm^3mol^{-1}s^{-1}.$ We found the immobilized layer at the modified electrode acted as an electrocatalyst. Finally, this polymerization process at the Pt electrode was the electron transfer controlled, but that the mixed polymer electrode was the diffusion and charge transfer controlled.

  • PDF

Effect of Ionomer Content on the Anode Catalyst Layers of PEM Fuel Cells (고분자 전해질 연료전지용 수소극 촉매층의 이오노머 함량 영향)

  • PAK, BEOMJUN;LEE, SEONHO;WOO, SEUNGHEE;PARK, SEOK-HEE;JUNG, NAMGEE;YIM, SUNG-DAE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.6
    • /
    • pp.523-530
    • /
    • 2019
  • For the low-Pt electrodes for polymer electrolyte fuel cells (PEMFCs), the optimization of ionomer content for anode catalyst layers was carried out. A commercial catalyst of 20 wt.% Pt/C was used instead of 50 wt.% Pt/C which is commonly used for PEMFCs. The ionomer content varies from 0.6 to 1.2 based on ionomer to carbon ratio (I/C) and the catalyst layer is formed over the electrolyte by the ultrasonic spray process. Evaluation of the prepared MEA in the unit cell showed that the optimal ionomer content of the air electrode was 0.8 on the I/C basis, while the hydrogen electrode was optimal at the relatively high ionomer content of 1.0. In addition, a large difference in cell performance was observed when the ionomer content of the hydrogen electrode was changed. Increasing the ionomer content from 0.6 to 1.0 by I/C in a hydrogen electrode with 0.05 mg/㎠ platinum loading resulted in more than double cell performance improvements on a 0.6 V. Through the analysis of various electrochemical properties in the single cell, it was assumed that the change in ionomer content of the hydrogen electrode affects the water flow between the hydrogen and air electrodes bounded by the membrane in the cell, which affects the overall performance of the cell. A more specific study will be carried out to understand the water flow mechanism in the future, and this study will show that the optimization process of hydrogen electrode can also be a very important cell design variable for the low-Pt and high-performance MEA.

Disposal of CO in CO-Poisoning Dogs (일산화탄소중독견(一酸化炭素中毒犬) 체내(體內)에서의 일산화탄소처리능(一酸化炭素處理能)에 관(關)하여)

  • Ryo, Ung-Yun;Kang, Bann
    • The Korean Journal of Physiology
    • /
    • v.2 no.2
    • /
    • pp.93-99
    • /
    • 1968
  • The Present study attempted to analyze the fate of CO diffused into the circulating blood through the alveoli. Dogs were induced to CO poisoning by rebreathing CO gas mixture contained in Krog's spirometer, by closed circuit method, for 60 minutes. The spirometer was filled initially with 282 ml of CO and 20 liters of air and oxygen, so the composition of gases were arranged as 1.4% in CO and 50% in $O_2$ at the begining of the rebreathing. Oxygen was added corresponding to the utilization of $O_2$ by the animal in proceeding of the experiment. At 60th minutes of CO rebreathing, the concentration of CO in arterial blood and in mixed venous blood were analysed and compared with each other after the CO contents were corrected with the hematocrit measured in the arterial and mixed venous blood. The distribution of CO gas to other tissues was estimated by the analysis of CO diffused into the cystic bile and into the peritoneal gas pocket which was formed by injection of 300 ml air into the peritoneal cavity prior to the CO gas rebreathing. The blood volume was measured by dilution method using $^{51}Chromium$ tagged red cells. CO amount vanished in the animal body was calculated by subtraction of total CO content in blood stream and the CO remained in closed circuit breathing system from the CO amount given to the breathing system at the begining of the experiment. Results obtained are summarized as follows: 1. The content of CO corrected by the hematocrit value was slightly less in mixed venous blood than in arterial blood. The amount of CO diffused into the cystic bile and into the peritoneal cavity was averaged to 0.1% and 0.4% of the CO amount in 100 ml of blood, respectively. 2. For 60 minutes of CO rebreathing, CO-hemoglobin saturation reached about 77% at the 60th minutes, CO amount vanished in the experimental animal averaged 36.1 ml/dog/hr., or 21% of the total CO volume in the blood stream. The average vanishing rate of CO during 60 minutes of CO rebreathing per kg of body weight was 2.71 ml/hr. Production of CO measured in ten dogs under hypoxic condition averaged 0.023 ml/kg/hr. The major part of the CO vanished in the dogs seemed to be oxidized to $CO_2$ by various tissues of the animal. The conclusion might be delivered as such oxidation of CO to $CO_2$ by animal tissues can play a role in part of the process of recovery and protection of animal from CO-poisoning.

  • PDF

Comparison of Solidification Pre-treatment Methods for the Determination of δ13C of Dissolved Organic Carbon: Alkaline Persulfate Oxidation-Carbonate Precipitation vs. Freeze Drying (용존유기탄소의 δ13C : 분석시 고형화 전처리 방법 비교 알칼린 과황산칼륨산화 탄산침전과 동결건조)

  • Jeon, Byeong-Jun;Park, Hyun-Jin;Choi, Woo-Jung;Park, Yong-Se;Lee, Sang-Mo;Yoon, Kwang-Sik
    • Korean Journal of Environmental Agriculture
    • /
    • v.36 no.2
    • /
    • pp.113-118
    • /
    • 2017
  • BACKGROUND: The carbon (C) isotope ratio (${\delta}^{13}C$) of dissolved organic C (DOC) is an indicator of water pollution source. In this study, the potential use of two pre-treatments for the ${\delta}^{13}C$ analysis, alkaline persulfate oxidation coupled with carbonate precipitation (precipitation) and freeze drying (drying), were compared to suggest a more feasible pre-treatment method. METHODS AND RESULTS: Two reference materials with different ${\delta}^{13}C$ values were used for the experiments; chemical grade glucose ($-12.0{\pm}0.02$‰) and pig manure compost extract ($-23.3{\pm}0.04$‰). In the precipitation method, the measured ${\delta}^{13}C$ values were consistently lower than the theoretically calculated values as dissolved $CO_2$ could not be removed due to the alkaline property of the reagents and the dissolution of air $CO_2$ into the alkaline solution. The drying method also resulted in more negative ${\delta}^{13}C$ than the calculated ${\delta}^{13}C$; however, the difference was systematic ($3.9{\pm}0.3$‰) and there was a strong correlation (${\delta}^{13}C_{calculated}=0.87{\times}{\delta}^{13}C_{measured}-0.624$, $r^2=0.98$) between the calculated and measured ${\delta}^{13}C$. Calibration of ${\delta}^{13}C$ using the relationship between the calculated and the measured ${\delta}^{13}C$ values produced reliable and accurate ${\delta}^{13}C$ values. CONCLUSION: Our results suggest that the drying method is more accurate pre-treatment method to minimize the influence of air $CO_2$ compared to the precipitation method for the determination of ${\delta}^{13}C$ of DOC.

Study on Hydrogen Production and CO Oxidation Reaction using Plasma Reforming System with PEMFC (고분자 전해질 연료전지용 플라즈마 개질 시스템에서 수소 생산 및 CO 산화반응에 관한 연구)

  • Hong, Suck Joo;Lim, Mun Sup;Chun, Young Nam
    • Korean Chemical Engineering Research
    • /
    • v.45 no.6
    • /
    • pp.656-662
    • /
    • 2007
  • Fuel reformer using plasma and shift reactor for CO oxidation were designed and manufactured as $H_2$ supply device to operate a polymer electrolyte membrane fuel cell (PEMFC). $H_2$ selectivity was increased by non-thermal plasma reformer using GlidArc discharge with Ni catalyst simultaneously. Shift reactor was consisted of steam generator, low temperature shifter, high temperature shifter and preferential oxidation reactor. Parametric screening studies of fuel reformer were conducted, in which there were the variations of the catalyst temperature, gas component ratio, total gas ratio and input power. and parametric screening studies of shift reactor were conducted, in which there were the variations of the air flow rate, stema flow rate and temperature. When the $O_2/C$ ratio was 0.64, total gas flow rate was 14.2 l/min, catalytic reactor temperature was $672^{\circ}C$ and input power 1.1 kJ/L, the production of $H_2$ was maximized 41.1%. And $CH_4$ conversion rate, $H_2$ yield and reformer energy density were 88.7%, 54% and 35.2% respectively. When the $O_2/C$ ratio was 0.3 in the PrOx reactor, steam flow ratio was 2.8 in the HTS, and temperature were 475, 314, 260, $235^{\circ}C$ in the HTS, LTS, PrOx, the conversion of CO was optimized conditions of shift reactor using simulated reformate gas. Preheat time of the reactor using plasma was 30 min, component of reformed gas from shift reactor were $H_2$ 38%, CO<10 ppm, $N_2$ 36%, $CO_2$ 21% and $CH_4$ 4%.

Soil CO2 Monitoring Around Wells Discharging Methane (메탄 유출 관정 주변의 토양 CO2 모니터링)

  • Chae, Gitak;Kim, Chan Yeong;Ju, Gahyeun;Park, Kwon Gyu;Roh, Yul;Lee, Changhyun;Yum, Byoung-Woo;Kim, Gi-Bae
    • Economic and Environmental Geology
    • /
    • v.55 no.4
    • /
    • pp.407-419
    • /
    • 2022
  • Soil(vadose zone) gas compositions were measured for about 3 days to suggest a method for monitoring and interpreting soil gas data collected around wells from which methane(CH4) is outflowing. The vadose zone gas samples were collected within 1 m around two test wells(TB2 and TB3) at Pohang and analyzed for CO2, CH4, N2 and O2 concentrations in situ. CO2 flux was measured beside TB2. In addition, gas samples from well head in TB2 and atmospheric air samples were collected for comparison. Carbon isotopes of CO213CCO2) of samples collected on the last day of the study period were analyzed in the laboratory. The two test wells (TB2 and 3) were 12.7 m apart and only TB3 was cemented to the surface. According to the bio-geochemical process-based interpretation, the relationships between CO2 and O2, N2, and N2/O2 of vadose zone gas were plotted between the lines of CH4 oxidation and CO2 dissolution. In addition, the CH4 concentrations of gas samples from the wellhead of the uncemented well (TB2) were 5.2 times higher than the atmospheric CH4 concentration. High CO2 concentrations (average 1.148%) of vadose zone gas around TB2 seemed to be attributed to the oxidation of CH4. On the other hand, the vadose zone CO2 around the cemented well(TB3) showed a relatively low concentration(0.136%). This difference indicates that the vadose zone gas(including CO2) around the CH4 outflowing well were strongly affected by well completion(cementing). This study result can be used to establish strategies for environmental monitoring of soil around natural gas sites, and can be used to monitor leakage around injection and observation wells for CO2 geological storage. In addition, the method of this study is useful for soil monitoring in natural gas storage and oil-contaminated sites.

Quality Comparison of Chuncheon Dakgalbi Made from Korean Native Chickens and Broilers (토종닭과 육계로 만든 춘천닭갈비의 품질비교)

  • Lee, Sung-Ki;Choi, Won-Hee;Muhlisin, Muhlisin;Kang, Sun-Moon;Kim, Cheon-Jei;Ahn, Byoung-Ki;Kang, Chang-Won
    • Food Science of Animal Resources
    • /
    • v.31 no.5
    • /
    • pp.731-740
    • /
    • 2011
  • This study was conducted to evaluate a quality comparison between Chuncheon Dakgalbi made from Korean native chickens (KNC) and that made from commercial broilers. Two Korean native chickens including Woorimatdag (KNCWoori) and Hanhyup3 (KNC-Hanhyup), and two commercial broilers including grades of 18 (Broiler-18) and 13 (Broiler-13) were slaughtered at 110, 70, 38, and 31 d of ages. Chuncheon dalkalbi was prepared by mixing/dipping the meat in chili pepper sauce; it was then packed with air-packaging (Air-P) and 30% $CO_2$-MAP (0% $O_2$/30% $CO_2$/70% $N_2$), and stored at $5^{\circ}C$ for 10 d. The results showed that the KNC group had a lower pH but a higher cooking loss compared with the broiler group (p<0.05). In a texture analysis, KNC-Woori had the highest shear force value among the breeds (p<0.05). For the fatty acid composition of the thigh, the KNC-Woori contained more total saturated acids, myristic acid, palmitic acid and stearic acid, but less total unsaturated fatty acids, linoleic acid and linolenic acid than other breeds (p<0.05). Also, the n6/n3 ratios of the KNC group (19.24 and 16.77) were higher than those of the broiler group (14.02 and 14.77) (p<0.05). The total acceptability scores of Dakgalbi made from the KNC group were decreased by sensory panelists. The Dakgalbi with 30% $CO_2$-MAP delayed the protein deterioration (Volatile basic nitrogen) and lipid oxidation during storage. However, no clear evidence was observed of $CO_2$-MAP on the effect of different chicken materials. It is suggested that 30% $CO_2$-MAP instead of Air-P is used for methods for Chuncheon Dakgalbi. Furthermore, it might be unfavorable to use Korean native chickens as raw material for Chuncheon Dakgalbi from a practical quality point of view.

Quality characteristics of rice noodles treated with cold plasma (저온 플라즈마 처리한 쌀국수의 품질 특성)

  • Kim, Hyun-Joo;Lee, Byong Won;Baek, Ki Ho;Jo, Cheorun;Kim, Jae-Kyung;Lee, Jin Young;Lee, Yu-Young;Kim, Min Young;Kim, Mi Hyang;Lee, Byoungkyu
    • Korean Journal of Food Science and Technology
    • /
    • v.52 no.5
    • /
    • pp.560-563
    • /
    • 2020
  • Cold plasma has been applied to improve quality of food product; however, studies on its effects on microbial and physicochemical qualities of rice noodles are rarely conducted. In this study, changes in the quality characteristics of rice noodles treated by cold plasma were determined. Cold plasma was generated in a square-shaped plastic container (250 W, 15 kHz, ambient air), and dielectric barrier discharge plasma treatments were applied to rice noodle samples for 0, 10, or 20 min. Rice noodles inoculated with either Bacillus cereus or Escherichia coli O157:H7 were subjected to plasma treatment for 20 min, and the approximate bacterial count reduction were 4.10 and 2.75 log CFU/g, respectively. The Hunter color values of the sample were increased after cold plasma treatment. Peroxide values and thiobarbituric acid reactive substance (TBARS) were increased with an increase in cold plasma treatment time. Futhermore, lipid oxidation was enhanced. Although further studies are warranted to evaluate changes in chemical qualities, such as lipid oxidation of rice noodles, induced by cold plasma, the results suggest that cold plasma can improve the microbial and physical qualities of rice noodles.

Use of Discriminant Analysis to Identify Soil Quality Variation by Land Use (판별분석을 이용한 토지이용별 토양 특성 변화 연구)

  • Ko Kyung-Seok;Kim Jae Gon;Lee Jin-Soo;Kim Tack Hyun;Lee Gyoo Ho;Cho Choon Hee;Oh In Suk;Cheong Young Wook
    • Economic and Environmental Geology
    • /
    • v.38 no.3 s.172
    • /
    • pp.207-219
    • /
    • 2005
  • The physical and chemical characteristics of soils in a small watershed were investigated and the effect of geology and land use on soil quality were examined by using multivariate statistical methods, principal components analysis and discriminant analysis. The soil developed from andesite had finer texture and higher contents of water extractable inorganic components, clay, and mafic minerals than the soil developed from granite. It is considered that the accumulation of salts in the farmland soils indicated by electrical conductivity, contents of cations and anions and pH was caused by fertilizer input during cultivation. The low contents of organic matter in the farmland soils was due to the enhanced oxidation of organic matter by tillage and by the harvest of crops. The contents of inorganic components are increased as following order: upland > orchard > paddy field > forest. The high contents of water soluble $SO_4\;^{2-}$ of paddy soils is due to the oxidation of sulfides mineral formed during the flooding period during the air-dry and extraction. The results of principal components analysis show the difference of soil quality was controlled by geology and land use. PCI indicate the input of fertilizer, mineral weathering and ion exchange reaction by application of nitrogenous fertilizers. The results of two discriminant analyses using water extractable inorganic components and their ratios by land use were also clearly classified by discriminant function 1 and 2. In discriminant analysis by components, discriminant function 1 indicated the effect of fertilizer application and increased as following order: upland > orchard > paddy field > forest soil. The investigated and predicted data for land use from discriminant analysis showed similar results. The discriminant analysis can be used as a useful method certifying the change of land use.

Anaerobic Ammonium Oxidation(ANAMMOX) in a Granular Sludge Reactor and its Bio-molecular Characterization (입상 슬러지 반응조 내의 혐기성 암모늄 산화(ANAMMOX) 및 분자생태학적 특성 평가)

  • Han, Ji-Sun;Park, Hyun-A;Sung, Eun-Hae;Kim, Chang-Gyun;Yoon, Cho-Hee;Bae, Young-Shin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.11
    • /
    • pp.1213-1221
    • /
    • 2006
  • In this study, granular sludge used in an anaerobic process treating brewery waste was inoculated in a laboratory scale of reactor to induce anaerobic ammonium oxidation(ANAMMOX). The reactor was operated with synthetic wastewater, which prepared at 1:1 ratio of $NH_4^+-N$ over $NO_2^--N$. Changes in nitrogen concentration, COD, alkalinity and gas production were analyzed. There are 3 phases of spanning in experimental period according to influent nitrogen concentration. In the Phase 1, each of the concentration of $NH_4^+-N$ and $NO_2^--N$ were increased from 1.91 $gN/m^3{\cdot}d$ to 14.29 $gN/m^3{\cdot}d$. Ammonium nitrogen loading(same as nitrite nitrogen) was 23.81 $gN/m^3{\cdot}d$ in the Phase 2 and 19.05 $gN/m^3{\cdot}d$ in the Phase 3, respectively $NO_2^--N$ has been removed up to 99% during whole period while the removal efficiency of $NH_4^+-N$ was significantly varied. In Phase 2, $NH_4^+-N$ was removed up to 75%. Microorganisms varied temporally through three phases were characterized by 16s rDNA analysis methods. ANAMMOX bacteria were dominantly found in phase 2 when the removal rate of $NO_2^--N$and $NH_4^+-N$ was the highest up to 99% and 75%, respectively. Due to erroneous exposed to air, the removal efficiency of $NH_4^+-N$ was unexpectedly lowered, but ANAMMOX bacteria still existed.