• 제목/요약/키워드: advanced criterion

검색결과 237건 처리시간 0.029초

Receding Horizon Finite Memory Controls for Output Feedback Controls of Discrete-Time State Space Models

  • Han, Soo-Hee;Kwon, Wook-Hyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1896-1900
    • /
    • 2003
  • In this paper, a new type of output feedback control, called a receding horizon finite memory control (RHFMC), is proposed for stochastic discrete-time state space systems. Constraints such as linearity and finite memory structure with respect to an input and an output, and unbiasedness from the optimal state feedback control are required in advance. The proposed RHFMC is chosen to minimize an optimal criterion with these constraints. The RHFMC is obtained in an explicit closed form using the output and input information on the recent time interval. It is shown that the RHFMC consists of a receding horizon control and an FIR filter. The stability of the RHFMC is investigated for stochastic systems.

  • PDF

Design of Step-Stress Accelerated Life Tests for Weibull Distributions with a Nonconstant Shape Parameter

  • Kim, C. M.;D. S. Bai
    • Journal of the Korean Statistical Society
    • /
    • 제28권4호
    • /
    • pp.415-433
    • /
    • 1999
  • This paper considers the design of step-stress accelerated life tests for the Weibull distribution with a nonconstant shape parameter under Type I censoring. It is assumed that scale and shape parameters are log-linear functions of (possibly transformed) stress and that a cumulative exposure model holds for the effect of changing stress. The asymptotic variance of the maximum likelihood estimator of a stated quantile at design stress is used as an optimality criterion. The optimum three step-stress plans are presented for selected values of design parameters and the effects of errors in pre- estimates of the design parameters are investigated.

  • PDF

An Approach for the Automatic Box-Jenkins Modelling

  • Park, Sung-Joo;Hong, Chang-Soo;Jeon, Tae-Joon
    • 대한산업공학회지
    • /
    • 제10권1호
    • /
    • pp.17-25
    • /
    • 1984
  • The use of Box-Jenkins technique is still very limited due to the high level of knowledge required in comprehending the technique and the cumbersome iterative procedure which requires a large amount of cost and time. This paper proposes a method of automating the univariate Box-Jekins modelling to overcome the limitations of subjective identification in iterative procedure by using Variate Difference method, D-statistic and Pattern Recognition algorithm combined with Akaike's Information Criterion. The results of the application to real data show that the average performance of automatic modelling procedure is better or not worse, at least, than those of the existing models which have been manually set up and reported in the literature.

  • PDF

Analysis of Failure in Miniature X-ray Tubes with Gated Carbon Nanotube Field Emitters

  • Kang, Jun-Tae;Kim, Jae-Woo;Jeong, Jin-Woo;Choi, Sungyoul;Choi, Jeongyong;Ahn, Seungjoon;Song, Yoon-Ho
    • ETRI Journal
    • /
    • 제35권6호
    • /
    • pp.1164-1167
    • /
    • 2013
  • We correlate the failure in miniature X-ray tubes with the field emission gate leakage current of gated carbon nanotube emitters. The miniature X-ray tube, even with a small gate leakage current, exhibits an induced voltage on the gate electrode by the anode bias voltage, resulting in a very unstable operation and finally a failure. The induced gate voltage is apparently caused by charging at the insulating spacer of the miniature X-ray tube through the gate leakage current of the field emission. The gate leakage current could be a criterion for the successful fabrication of miniature X-ray tubes.

모델보정을 위한 구조물 매개변수 규명시 가진점 .측정점의 선정 (Excitation and Measurement Points Selection to Identify Structural Parameters for Model Tuning)

  • 박남규;박윤식
    • 대한기계학회논문집A
    • /
    • 제24권5호
    • /
    • pp.1271-1280
    • /
    • 2000
  • A sensor placement technique to identify structural parameter was developed. Experimental results must be acquired to identify unknown dynamic characteristics of a targeting structure for the comparison between analytical model and real structure. If the experimental environment was not equipped itself properly, it can be happened that some valuable information are distorted or ill-condition can be occurred. In this work the index to determine exciting points was derived from the criterion of maximizing parameter sensitivity matrix and that to choose measurement points was from that of preserving the invariant of sensitivity matrix. This idea was applied to a compressor hull structure to verify its performance. The result shows that the selection of measurement and excitation points using suggested criteria improve the ill-conditioning problem of inverse type problems such , as model updating.

유전자 알고리즘을 이용한 예측제어 (Constrained GA-based Predictive Control)

  • Seung C. Shin;Zeungnam Bien
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 추계종합학술대회 논문집
    • /
    • pp.732-735
    • /
    • 1999
  • A GA-based optimization technique is adopted in the paper to obtain optimal future control inputs for predictive control systems. For reliable future predictions of a process, we identify the underlying process with an NNARX model structure and investigate to reduce the volume of neural network based on the Lipschitz index and a criterion. Since most industrial processes are subject to their constraints, we deal with the input-output constraints by modifying some genetic operators and/or using a penalty strategy in the GAPC. Some computer simulations are given to show the effectiveness of the GAPC method compared with the adaptive GPC algorithm.

  • PDF

A Distributed Dynamic Channel Assignment Algorithm in Highway Microcells

  • Lee, Chae-Young;Park, Hyun-Jeong
    • 한국경영과학회지
    • /
    • 제21권2호
    • /
    • pp.187-201
    • /
    • 1996
  • A distributed dynamic channel assignment is proposed and its performance is examined in a highway microcellular radio environment. In the two step ordered local packing (TOLP) scheme, channels are assigned on an ordered basis under cochannel utilization in congested microcell region. A selection criterion is employed to decide the cell from which a free channel is borrowed. Simulation results show that the proposed scheme outperforms existing methods is channel utilization and call blocking probabilities, especially under asymmetric call arrivals with a lower call switching requirement.

  • PDF

Efficient Design of 2-D FIR Fan Filters Using New Formulas for McClellan Transform Parameters

  • Song, Young-Seog;Lee, Yong-Hoon
    • Journal of Electrical Engineering and information Science
    • /
    • 제1권1호
    • /
    • pp.160-163
    • /
    • 1996
  • New formulas for McClellan transform parameters for the design of 2-D zero-phase FIR fan filters are optimally derived under the integral squared error(ISE) criterion. By imposing the constraint that F(0, 0)=\ulcorner, where F($.$) is the McClellan transform and $\omega$\ulcorner is the cutoff frequency of the 1-D prototype filter, the ISE is directly minimized without modifying it and, as a consequence, closed-form formulas for the McClellan transform parameters are obtained. It is shown that these formulas lead to a very efficient design for 2-D zero-phase FIR fan filters.

  • PDF

Numerical modeling and prediction of adhesion failure of adhesively bonded composite T-Joint structure

  • Panda, Subhransu K;Mishra, Pradeep K;Panda, Subrata K
    • Structural Engineering and Mechanics
    • /
    • 제74권6호
    • /
    • pp.723-735
    • /
    • 2020
  • This study is reported the adhesion failure in adhesive bonded composite and specifically for the T-joint structure. Three-dimensional finite element analysis has been performed using a commercial tool and the necessary outcomes are obtained via an eight noded solid element (Solid 185-element) from the library of ANSYS. The structural analysis input has been incurred through ANSYS parametric design language (APDL) code. The normal and shear stress distributions along different layers of the joint structure have been evaluated as the final outcomes. Based on the stress distributions, failure location in the composite joint structure has been identified by using the Tsai-Wu stress failure criterion. It has been found that the failure index is maximum at the interface between flange and web part of the joint (top layer) which indicates the probable location of failure initiation. This kind of failures are considered as adhesion failure and the failure propagation is governed by strain energy release rate (SERR) of fracture mechanics. The different adhesion failure lengths are also considered at the failure location to calculate the SERR values i.e. mode I fracture (opening), mode II fracture (sliding) and mode III fracture (tearing) along the failure front. Also, virtual crack closure technique (VCCT) principle of fracture mechanics steps is used to calculate the above said SERRs. It is found that the mode I SERR is more dominating compared to other two modes of failure for the joint considered. Finally, the influences of various parametric (geometrical and material) effect on SERR of the joint structure are evaluated and discussed in details.

590인승 Ro-Pax형(型) 연안여객선의 선실 내 봄철 온열환경 측정평가 (A Measurement and Evaluation of Indoor Thermal Conditions in Spring of a Coastal Passenger Ship - 590-Passenger Ro-Pax Type)

  • 황광일;신동걸;김은수;도요한;최윤석;최정열
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권8호
    • /
    • pp.1170-1177
    • /
    • 2008
  • The purpose of this study is to measure and analyze the indoor thermal conditions in the spring of a korean coastal passenger ship which is 590-passenger Ro-Pax type built at 1997. Especially this study has focussed on the relations between the diffuser open ratio, which can be controlled by 12 steps, and the comfort. Followings are the results of this study. (1) The supply air volume to cabins are maximum 4.3 and 2 times more than design quantity when the diffusers in cabins are open 100% and 50%, respectively. (2) Regardless of diffuser open ratio, the supply air maintains constantly high temperature and below 10% of relative humidity through the experimental days. (3) All the cabins are not satisfied with the ASHRAE comfort criterion at the condition of 100% and 50% of diffuser open ratio, because of high temperature and low relative humidity. (4) At a low diffuser open ratio, number of cabins which satisfy the ASHRAE comfort criterion are increased. (5) Humidifying and dehumidifying, and hvac control system of each cabin must be reviewed and studied at the view of passengers to service more comfort environments.