• 제목/요약/키워드: address discharge

검색결과 178건 처리시간 0.026초

Sustain 구간중 Address 전극에 인가되는 전압 펄스 폭에 따른 3차원 방전형상 분석 (The 3- dimensional analysis for the discharge of PDP according to the pulse width of voltage applied to the address electrode during sustain period)

  • 권형석;최훈영;이승걸;이석현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1830-1833
    • /
    • 2002
  • We measured 3-dimensional temporal behavior of the light emitted from AC plasma display panel(PDP) at various auxiliary voltage pulse width supplied to the address electrode in sustain period using scanned point detecting system. In the case of applying an auxiliary address voltage pulse, the light emission starts at the inner edges of the cathode so the larger discharge volume toward address electrode can be obtained compared with the normal sustain discharge. Especially, when the auxiliary voltage pulse width is the $2{\mu}s$, the maximum luminance and long emission time can be obtained.

  • PDF

AC PDP에서 고속 어드레싱을 위한 ADR(Address During Reset) 구동 방식 (The ADR(Address During Reset) Driving Method for High-Speed Addressing in an AC-PDP)

  • 송근영;김근수;이석현
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권6호
    • /
    • pp.269-273
    • /
    • 2005
  • In order to achieve high efficiency and low cost, new high-speed addressing method is suggested. This can be implemented by reducing the address discharge time lag through the priming effect. This paper suggests a new ADR(Address During Reset) driving method which provides priming particles by a separated driving method without adding auxiliary electrode or auxiliary discharge. The experimental results show an approximately 100ns reduction in the formative delay time of address discharge and a reduction in jitter of over 200ns. Also, due to enough time being available for reset, there was a reduction of about 29$\%$ in linht emitted during the reset period considerably.

Characteristic of Facing Discharge Front plate Address Electrode Structure in AC PDP

  • Cho, Hyun-Min;Kim, Dong-Hwan;Song, In-Cheol;Kim, Yun-Gi;Ok, Jung-Woo;Kim, Dong-Hyun;Lee, Hae-June;Lee, Ho-Jun;Park, Chung-Hoo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.104-107
    • /
    • 2009
  • In order to improve discharge characteristics in AC PDP, we suggest FDFA (Facing Discharge Front plate Address Electrode) structure. By adopting both long facing discharge electrodes and address electrodes in front plate, the FDFA structure make it possible to gain a high luminance, low power consumption, and a high luminous efficiency.

  • PDF

Observation and Analysis of Address and Sustain Discharges and Related Wall Voltage Characteristics AC-PDP

  • Park, Hyung-Dal;Tae, Heung-Sik;Hur, Min;Park, Soo-Ho;Yoo, Min-Son;Heo, Eun-Gi
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.597-600
    • /
    • 2007
  • The address and sustain discharge characteristics in plasma display panels (PDPs) are investigated and compared by the optical emission spectroscopy using the ICCD and Vt close-curve analysis. The observations on the xenon (Xe) emission show that the spatial and temporal evolutions in the first sustain discharge are quite different from those in the address and the other sustain discharges. The striation found in the conventional sustain discharge doesn't occur in the first sustain discharge. These different discharge behaviors are explained by employing the Vt close-curve.

  • PDF

HDTV급 플라즈마 디스플레이의 고속 어드레스 방전특성에 관한 연구 (A Study on the Discharge Characteristics of High Speed Addressing for the HDTV Class Plasma Display)

  • 염정덕
    • 조명전기설비학회논문지
    • /
    • 제15권1호
    • /
    • pp.13-21
    • /
    • 2001
  • 3전극 교류형 면방전 플라즈마 디스플레이의 방전특성을 분석하여 최대 방전전압에서 나타나는 방전의 불안정성은 2차방전에 의한 벽전하의 부분소거가 원임임을 알았다. 이를 이용하여 어드레스 방전과 표시방전의 상호관계를 고려한 동작마진을 새로이 정의하였고 실험을 통하여 이의 타당성을 검증하였다. 고속 어드레싱을 하기 위해서는 어드레스 펄스폭을 줄여야 한다. 그러나 어드레스 펄스폭이 좁아지면 어드레스 펄스의 동작마진이 줄어든다. 반면에 표시방전 유지펄스의 동작마진은 어드레스 펄스폭이 $1[{\mu}s]$ 이상만 되면 어드레스 펄스폭에 무관하다는 것을 알앗다. 시렇ㅁ결과 펄스폭 $1[{\mu}s]$의 고속 어드레스 ADS 구동방식으로 HDTV급 셀구조를 가지는 플라즈마 디스플레이 패널에 8bit 256계조의 화상을 구현 하였고 $560[cd/m^2]$의 휘도를 얻었다.

  • PDF

AC-PDP의 유지방전 전극사이의 간격과 어드레스 방전 특성과의 상관성 분석 (The Analysis of the Correlation between the Sustain-Electrode Gap of an AC-PDP and Address Discharge Characteristics)

  • 이영준;최수삼;박세광;김용득
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권5호
    • /
    • pp.239-244
    • /
    • 2006
  • To drive the high-image quality plasma displays of XGA and/or full-HD, we must effectively improve the driving waveform, which get the reset period for the stabilized control of wall charges, the address period to select discharge or non-discharge, and sustain period for luminance in 1 TV-frame, and also the display quality. To accomplish them, the development of the technology for the fast address discharge is required. In this paper, the correlation between the sustain-electrode gap and address discharge characteristics for the high-speed addressing was analyzed using the measurements of dynamic voltage margins. Results showed that the narrower the gap between the sustain electrodes, the narrower the with of the scan pulse became and a dynamic margin of data voltage of 29.2 V was obtained at scan pulse width of $1.0{\mu}s\;and\;V_{ramp}$ of 240 V for driving 4-inch test penal, which the gap between sustain electrodes was $65{\mu}m$.

교류형 플라즈마 디스플레이의 Address 전극의 전압에 따른 Sustain 방전 특성 연구 (A Study on the Sustain Discharge Characteristics as the Voltage of Address Electrode of AC-Plasma Display)

  • 신재화;최훈영;이석현
    • 전기학회논문지P
    • /
    • 제52권2호
    • /
    • pp.61-67
    • /
    • 2003
  • To improve the luminance and luminous efficiency of a surface-discharge alternate current plasma display panel, we analyzed the sustain discharge characteristics as the voltage of the address electrode In the study. As the results, when the address voltage is a half of the sustain voltage in the sustain period, the luminance and luminance efficiency are the highest. The luminance efficiency increased about 16.2%~20.8% compared with the conventional type.

A new ramp reset waveform for reducing reset period using address pulse of AC-PDP

  • Kim, Gun-Su;Choi, Hoon-Young;Lee, Seok-Hyun;Kim, Jun-Hyoung;Mim, Byoung-Kuk
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.609-612
    • /
    • 2002
  • A new reset waveform is proposed for reducing the reset period. A square pulse is applied to the address electrode while reset pulse ramps and before a discharge between the sustain electrodes occurs. The square pulse induces a discharge between the address electrode and the X electrode, and the induced wall charge is opposite to the applied ramp pulse. Thus, the next discharge between the sustain electrodes becomes weaker. The weaker discharge lowers background luminance and improves contrast ratio. Thus, the new reset waveform can reduce ramp up time in the ramp reset waveform The experimental results show that the ramp up time can be reduced by about 90% compared with the conventional ramp reset waveform.

  • PDF

AC PDP의 오방전 개선을 위한 어드레스 방전 특성 연구 (Study on the Address Discharge Characteristics for the Improvement of the Mis-firing Problem in AC PDP)

  • 전원재;김동훈;이석현
    • 전기학회논문지
    • /
    • 제58권6호
    • /
    • pp.1151-1156
    • /
    • 2009
  • Unstable sustain discharges can occur at the bottom cells of the panel at high temperature. To solve this problem, the wall charge variation during an address period was investigated. A test panel of 7.5 inch XGA level was used and one green cell was measured. In order to realize operating condition equal to that of the bottom cells of 50 inch panel, the addressing stress pulses are applied. It seems that the resultant wall charge loss during address period increased with increase of stress time, temperature, pressure and Xe %. Wall charge loss increases with potential difference between scan electrode and address electrode, therefore wall charge loss can be minimized by the increase of scan voltage during address period.

Effect of Auxiliary Address Pulse on Face-to-face Sustain Electrode Structure in AC-PDP

  • Kim, Bo-Sung;Tae, Heung-Sik
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.605-608
    • /
    • 2007
  • The discharge characteristics of the face-to-face sustain electrode structure employing auxiliary address pulse are investigated under a sustain driving frequency of 20 kHz and various auxiliary address pulse widths (500 ns, $1{\mu}s$, $2\;{\mu}s$) in the 6-in. test panel (42-in. Full HD grade) with a pressure of 450 Torr and a 4 % Xe-content. The luminance and the luminous efficiency at the auxiliary address pulse width of 500 ns are improved more than these of $1\;{\mu}s$ and $2\;{\mu}s$. At the auxiliary address pulse width of 500 ns, the luminous efficiency shows about 0.96 lm/W at the auxiliary pulse of 90 V and the sustain voltage of 260 V.

  • PDF