Browse > Article

Study on the Address Discharge Characteristics for the Improvement of the Mis-firing Problem in AC PDP  

Jeon, Won-Jae (인하대 IT공대 전기공학과)
Kim, Dong-Hun (인하대 IT공대 전기공학과)
Lee, Seok-Hyun (인하대 IT공대 전기공학과)
Publication Information
The Transactions of The Korean Institute of Electrical Engineers / v.58, no.6, 2009 , pp. 1151-1156 More about this Journal
Abstract
Unstable sustain discharges can occur at the bottom cells of the panel at high temperature. To solve this problem, the wall charge variation during an address period was investigated. A test panel of 7.5 inch XGA level was used and one green cell was measured. In order to realize operating condition equal to that of the bottom cells of 50 inch panel, the addressing stress pulses are applied. It seems that the resultant wall charge loss during address period increased with increase of stress time, temperature, pressure and Xe %. Wall charge loss increases with potential difference between scan electrode and address electrode, therefore wall charge loss can be minimized by the increase of scan voltage during address period.
Keywords
PDP; Address discharge; Wall charge; Misfiring;
Citations & Related Records

Times Cited By SCOPUS : 0
연도 인용수 순위
  • Reference
1 Ji Yong Kim, Dong -Hun Kim, Tae Yong Song, Sun Kim, Seok-Hyun Lee, Joon-Yub Kim* 'A Study on the Improvement of Address Discharge Time Lag in AC PDP at Low Temperature' ASID. WP 1.02, pp. 369-372 October, 2006
2 Byung-Tae Choi, Hyung Dal Park, Jae Kwang Lim, and Heung-Sik Tae 'Analysis of Wall VoltageVariation During Address Period Using V(t) Closed Curves' SID'07 Digest, pp. 565-568, 2007   DOI   ScienceOn
3 Larry F. Weber, 'The Promise of Plasma Display for HD-TV.', Society for Information Display(SID), vol. 16, no. 12, pp 16-20, 2000   DOI
4 H. Uchike, T. Hirakawa, 'Color Plasma Displays', Proceedings of the IEEE, vol, 90, No.4, April 2002   DOI   ScienceOn