• Title/Summary/Keyword: a spectrum

Search Result 10,373, Processing Time 0.047 seconds

Mechanism and Activation Parameters $({\Delta}H^{\neq},\;{\Delta}S^{\neq}$ and ${\Delta}V^{\neq})$ of Electron Transfer Reaction Between $Co^{II}CyDTA\;and\;Fe^{III}$CN Complex Ions (Co(II)-CyDTA와 Fe(III)-CN 착이온간의 전자이동반응에서 활성화파라미터 $({\Delta}H^{\neq},\;{\Delta}S^{\neq}$${\Delta}V^{\neq})$ 와 반응메카니즘)

  • Yu Chul Park;Seong Su Kim
    • Journal of the Korean Chemical Society
    • /
    • v.33 no.3
    • /
    • pp.273-280
    • /
    • 1989
  • The spectra of the $Co^{II}CyDTA$(CyDTA: cyclohexyldiaminetetraacetic acid) complex have been measured in aqueous solution of pH = 6-13.2. The red shift of the spectrum in the more basic solution was ascribed to the transformation of $CoCyDTA^{2-}$ into $CoCyDTA(OH)^{3-}$. The equilibrium constant, $K_{OH} = [CoCyDTA(OH)^{3-}]/[CoCyDTA^{2-}][OH^-]$ was $75M^{-1}$ at $40^{\circ}C$. The electron transfer reactions of $CoCyDTA^{2-}$ and $CoCyDTA(OH)^{3-}$ with $Fe(CN)_6^{3-}$ have been studied using spectrophotometric technique in the range of pH applied to the determination of equilibrium constant. The pseudo first-order rate constants observed ($k_{obs}$) were not changed upto pH = 10.8, but increased with increasing pH in the range of pH = $10.8{\sim}13.0$. The rate law reduced in the range of pH = 6-13 was $k_{obs} = (k_3[CoCyDTA^{2-}] + k_4[CoCyDTA(OH)^{3-}])/(1+K_1[CoCyDTA^{2-}])$. The rate constants of the reactions (3a) and (3b), $k_3$ and $k_4$ respectively have been determined to be 0.529 and $4.500M^{-1}sec^{-1}$ at $40^{\circ}C$. The activation entropies (147{\pm}1.1JK^{-1} mol^{-1}$ at pH = 10.8) and activation volumes $(6.25cm^3mol^{-1}, pH = 10.8)$ increased with increasing pH, while the activation enthalpy (12.44 ${\pm}$ 0.20 kcal/mole) was independent of pH. Using the pH effect on the rate constants, the activation entropies and the activation volumes, the mechanism of the electron transfer reaction for $Co^{II}-Fe^{III}$ system was discussed.

  • PDF

Evaluation for the Antimicrobial, Antioxidant and Anti-thrombosis Activity of Korean Traditional Liquors (시판 전통주의 항균, 항산화 및 항혈전 활성 평가)

  • Ryu, Hee-Young;Kum, Eun-Joo;Bae, Kyung-Hwa;Kim, Young-Kwan;Kwun, In-Sook;Sohn, Ho-Yong
    • Microbiology and Biotechnology Letters
    • /
    • v.35 no.3
    • /
    • pp.238-244
    • /
    • 2007
  • To identify the useful biological activities and the superiority in quality of Korean traditional liquors, we prepared the alcohol-free concentrates from different types of commercial traditional liquors, Takju ($T1{\sim}T3$), Yakju/Cheongju ($Y-1{\sim}Y-5$), Fruit wine (F-1) and Soju (S-1, S-2), respectively. We investigate their compositions as well as antimicrobial, antioxidant, and anti-thrombosis activity. Among the 11 traditional liquors, Y-3, Y-4, Y-5 and F-1 showed higher total-polyphenol, total-flavonoids and reducing sugars than the others. The strong antibacterial and anti-thrombosis activities were identified in Y-3, Y-4, Y-5 and F-1, and a minor antioxidant activity was found in F-l. The antibacterial activity of the Y-3, Y-4, Y-5 and F-1 alcohol-free concentrates showed a broad-spectrum, and growth inhibition was found in gram-positive, gram-negative, and ampicillin-resistant bacteria. The sequential solvent fractionation of Y-3, Y-4, Y-5 and F-1, and following analysis showed that ethyl acetate fractions of Y-3, Y-4, Y-5 and F-1 possess strong antibacterial and anti-thrombosis activity. Especially, the ethyl acetate fractions of Y-3, Y-4 and F-1 showed superior anti-thrombosis activity compared than that of aspirin. Our results suggest that the useful substances are produced from substrates and edible plant added during the fermentation, and the Korean traditional liquors could be developed as strong antibacterial and anti-thrombosis agents.

A Design of PLL and Spread Spectrum Clock Generator for 2.7Gbps/1.62Gbps DisplayPort Transmitter (2.7Gbps/1.62Gbps DisplayPort 송신기용 PLL 및 확산대역 클록 발생기의 설계)

  • Kim, Young-Shin;Kim, Seong-Geun;Pu, Young-Gun;Hur, Jeong;Lee, Kang-Yoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.2
    • /
    • pp.21-31
    • /
    • 2010
  • This paper presents a design of PLL and SSCG for reducing the EMI effect at the electronic machinery and tools for DisplayPort application. This system is composed of the essential element of PLL and Charge-Pump2 and Reference Clock Divider to implement the SSCG operation. In this paper, 270MHz/162MHz dual-mode PLL that can provide 10-phase and 1.35GHz/810MHz PLL that can reduce the jitter are designed for 2.7Gbps/162Gbps DisplayPort application. The jitter can be reduced drastically by combining 270MHz/162MHz PLL with 2-stage 5 to 1 serializer and 1.35GHz PLL with 2 to 1 serializer. This paper propose the frequency divider topology which can share the divider between modes and guarantee the 50% duty ratio. And, the output current mismatch can be reduced by using the proposed charge-pump topology. It is implemented using 0.13 um CMOS process and die areas of 270MHz/162MHz PLL and 1.35GHz/810MHz PLL are $650um\;{\times}\;500um$ and $600um\;{\times}\;500um$, respectively. The VCO tuning range of 270 MHz/162 MHz PLL is 330 MHz and the phase noise is -114 dBc/Hz at 1 MHz offset. The measured SSCG down spread amplitude is 0.5% and modulation frequency is 31kHz. The total power consumption is 48mW.

Influence of the curing time for the adhesive on the oxygen-inhibited layer thickness and the shear bond strength to dentin (광조사 시간이 접착제의 표면 미중합층의 두께와 전단접착강도에 미치는 영향에 관한 연구)

  • Choi, Yong-Hoon;Bae, Ji-Hyun;Son, Ho-Hyun;Lee, In-Bog;Um, Chung-Moon;Baek, Seung-Ho;Kim, Oh-Young;Kim, Chang-Keun;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.2
    • /
    • pp.177-184
    • /
    • 2004
  • Objectives : This study investigated the hypothesis that increasing light-curing time would leave the oxygen-inhibited layer (OIL) of the adhesive thinner, and in turn, result in lower shear bond strength (SBS) than those obtained by the routine curing procedures. Methods:120 human extracted posterior teeth were randomly divided into three groups for bonding with three adhesives:All Bond 2/sup (R)/, One Step/sup (R)/, and Adper Prompt/sup (R)/. They were subsequently divided into four subgourps with different light-curing time (10, 20, 30 and 60s). The assigned adhesives were applied on superficial occlusal dentin according to the manufacturer's instructions and cured with one of the four curing times. Composite resin cylinder, 2.35㎜ in diameter, were built on the cured adhesive and light-cured for 40s. SBS were measured after 24h from the bonding using a universal testing machine (crosshead speed 1.0 ㎜/min). The relative thickness of the OIL and the degree of conversion (DC) were determined from the adhesive on a slide glass using FT-NIR in an absorbance mode. Data were analysed with One-way ANOVA and Duncan's multiple test (p〈0.05), Results:With increasing cure time, although there were no significant difference in th SBS of One-step and Adper Prompt (p〉0.05), those of All Bond 2 decreased significantly (p〈0.05). The relative thicknesses of the OIL on each adhesive were not affected by the cure time (p〉0.05). Although the DC of All-Bond 2 were statistically not different with increasing cure time (p〉0.05), those of One-Step and Adper Prompt showed an increasing trends with increasing cure time (p〈0.05). Conclusions:Increasing light-curing time did not affect on the relative thickness of the OIL of the adhesives, and in turn, on the SBS to dentin.

Clinical Spectrum of Norovirus Gastroenteritis Compared to Rotavirus Gastroenteritis at a Single Center in Gwangju, Korea during 2005-2006 (2005-2006년 광주 지역에서 소아 Norovirus 장염의 임상적 고찰; Rotavirus 장염과 비교)

  • Lee, Yang Jin;Jeong, Seong Nam;Yoo, Ju Hee;Cho, Hyoung Min;Yoo, Eun Jung;Kim, Eun Young;Kim, Yong Wook;Kim, Kyoung Sim;Kim, Sun Hee
    • Pediatric Infection and Vaccine
    • /
    • v.16 no.1
    • /
    • pp.61-72
    • /
    • 2009
  • Purpose : We evaluated the clinical features of Norovirus gastroenteritis compared with Rotavirus gastroenteritis in hospitalized children. Methods : We detected causative agents in 3,261 samples of children hospitalized with gastroenteritis symptoms at a single center of pediatrics between 2005 and 2006. Among 266 and 303 samples which tested positive for Norovirus and Rotavirus, we selected 73 and 182 samples of children with relatively pure gastroenteritis symptoms and retrospectively analyzed the corresponding medical records. Results : The male-to-female ratio of the Norovirus (+) and Rotavirus (+) groupswas 1.43:1 and 1.56:1 both groups were predominantly in males. The mean age of the Norovirus (+) and Rotavirus (+) groups was 36.7 and 24.4 months, respectively the children in the former group were older than the children in the latter group. The incidence in the Norovirus (+) group was more concentrated in the winter. The symptoms in the Norovirus (+), in decreasing order, included vomiting, diarrhea, and fever. The duration of vomiting, diarrhea, and fever was 2.1, 1.2, and 1.2 days. The maximum number of episodes of vomiting and diarrhea per day was 3.5 and 4.5, respectively. The severity score was 10.16. The symptoms inthe Rotavirus (+) group, in decreasing order, included diarrhea, vomiting, and fever. The duration of diarrhea, vomiting, and fever was 2.2, 4.3, and 2.2 days, respectively. The maximum number of episodes of vomiting and diarrhea per day was 3.3 and 6.5, respectively. The severity score was 11.9. The severity in the Norovirus (+) group was somewhat lower than the Rotavirus (+) group. The younger the child, the more severe the symptoms in the Norovirus (+) group. There was no difference between mono-and co-infection in severity and between the two groups regarding the hematologic findings. Conclusion : Based on the findings reported herein, additional studies about prophylaxis, as well as the epidemiology and clinical features of pediatric Norovirus gastroenteritis, are required.

  • PDF

4th Industrial Revolution, Re-evaluation on Criticism of Confucian Familism - Rediscovering the Confucianism of Confucius and Mencius - (4차 산업혁명 시대, 유교의 가족주의 비판에 대한 재평가 - 공맹유학의 재발견 -)

  • Kim, Sang-hyun
    • Journal of Korean Philosophical Society
    • /
    • v.145
    • /
    • pp.1-43
    • /
    • 2018
  • This article intends to look for the desirable form of Confucian familism in the era of the 4th Industrial Revolution. First of all, the concept of the fourth industrial revolution is a very vague concept. Therefore, it would be more meaningful to analyze the situation of the family in present Korean society and to find an alternative to it in Confucian familism. But the problem is that it is very burdensome to bring out the Confucian familism idea again. Since Confucian Confucianism was criticized in 1915 during the New Cultural Movement, many people have criticized Confucian familism as patriarchal and authoritarian, and thus an anti-democratic value that seriously damaged the equality of men and women. Therefore, the discussion starts with looking at the justification of such an evaluation. I wanted to see if their evaluation of Confucian familism is legitimate or an unjustified evaluation resulting from misunderstanding, and if it is an inappropriate evaluation, where they are based. In addition, I examined whether the cause of such an evaluation was attributed to the subject who made the evaluation, or because the spectrum of significance contained in the Confucian familism thought formed over 2500 years was too wide. I sought to reassess criticism of the existing Confucian familism by looking for answers to these questions. Through such a reevaluation, I has found that the wrong criticism of Confucian familism was because we saw the Confucian scholarship and the Confucian scholarship without distinguishing the ideological Confucianism from the Qin(秦) Dynasty. In the end, I tried to show that Confucian familism can function as an alternative to resolve family problems that are occurring in today's Korean society through the illuminating work of the ideas of Confucian familism.

Element Dispersion and Wallrock Alteration Analysis Using Portable XRF and SWIR in the Samgwang Au Deposit (휴대용 XRF와 단파장적외선 분광분석을 이용한 삼광 금광상의 원소분산 및 모암변질 분석)

  • Kim, Junkyum;Shin, Dongbok;Yoo, Bongchul;Im, Heonkyung;Kim, Ilkyu
    • Economic and Environmental Geology
    • /
    • v.52 no.4
    • /
    • pp.259-274
    • /
    • 2019
  • Using portable XRF and SWIR analyzer, the characteristics of element dispersion and wallrock alterations induced by interaction between hydrothermal fluids and host rocks were investigated and ore exploration factors were estimated for the orogenic-type Samgwang Au deposits. On this purpose, in-situ measurements were conducted for 804 spots at regular intervals with a total of 4,824 times for host rocks, consisting of schist and gneiss, and altered wallrocks contacted with quartz veins in the Bonhang adit of the deposit, and the results were compared with quantitative data obtained by XRF and ICP analysis. The regression coefficients are 0.88 for major elements and 0.56 for trace elements, excluding V. For polished rock slabs, better results came out for major elements, 0.97 and for trace elements, 0.65. In altered wallrocks contacted with quartz veins, elements such as Fe, Zn, and Rb exhibit positive correlations with As in concentrations, while V forms a negative trend. Contour maps demonstrate that As, Zn, Rb, Fe, Ti, Cr, and Ni are enriched together near quartz veins, showing similar elemental behaviors. In-situ analysis using portable SWIR analyzer represents that schist and gneiss contain mica, illite, chlorite, sericite, amphibole, and epidote, while illite, sericite, gypsum, and mica are present in the altered rocks contacted with quartz veins. In contour maps, chlorite occurs mostly in host rocks, while sericite is concentrated near quartz veins. These results are similar to those of previous studies for element dispersion and hydrothermal alteration, and support the possibility for application of in-situ analysis on the exploration of orogenic gold deposit.

Comparison Evaluation of Image Quality with Different Thickness of Aluminum added Filter using GATE Simulation in Digital Radiography (GATE 시뮬레이션을 사용한 알루미늄 부가필터 두께에 따른 Digital Radiography의 영상 화질 비교 평가)

  • Oh, Minju;Hong, Joo-Wan;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.81-86
    • /
    • 2019
  • In X-ray image, the role of filtration through the filter is to reduce the exposure of the patient by using photon which is useful in formation of the image, and at the same time, enhance the contrast of the image. During interaction between photon and object, low energy X-rays are absorbed from the site of a few cm of the first patient's tissue, and high energy X-rays are the one which form the image. Therefore, the radiation filter absorbs low energy X-ray in order to lower the exposure of the patient and improve the quality of the image. The purpose of this study is to compare the effect on the image quality by differences of added filter through simulation image and actual radiation image. For that purpose, we used Geant4 Application for Tomographic Emission (GATE) as a tool for Monte Carlo simulation. We set actual size, shape and material of Polymethylmethacrylate (PMMA) Phantom on GATE and differentiated the parameter of added filter. Also, we took image of PMMA phantom with same parameter of added filter by digital radiography (DR). Than we performed contrast-to-noise ratio (CNR) evaluation on both simulation image and actual DR image by Image J. Finally, we observed the effect on image quality due to different thickness of added filter, and compared two images' CNR evaluation's transitions of change. The result of this experiment showed decreasing in the progress of CNR on both DR and simulation image. It is ultimately caused by decreasing in contrast on image. In theory, contrast decrease with kVp increased. Given that condition, this study found out that filter makes not only decreasing total dose by absorbing low energy of X-ray, but also increasing average energy of X-ray.

Single Dose Oral Toxicity Test of Water Extract of Corni Fructus in ICR Mice (ICR 마우스를 이용한 산수유 건피 추출물의 단회 경구투여 독성시험)

  • Hwang-Bo, Hyun;Kwon, Da Hye;Kim, Min Young;Ji, Seon Yeong;Choi, Eun Ok;Kim, Sung Ok;Jeong, Ji-Suk;Hong, Su Hyun;Choi, Sung Hyun;Park, Cheol;Choi, Yung Hyun
    • Journal of Life Science
    • /
    • v.29 no.1
    • /
    • pp.112-117
    • /
    • 2019
  • Herbal medicines are widely used as therapeutic products in many countries. Corni fructus (CF), the dried ripe sarcocarp of Cornus officinalis Sieb. et Zucc (Cornaceae), has been used for thousands of years in traditional medicine and has been reported to be effective for the prevention and treatment of various diseases, such as kidney diseases and diabetes. Recent research on CF has documented a wide spectrum of therapeutic properties, which include anti-inflammatory, ant-oxidative, immunomodulatory, and anti-cancer effects. However, there is no information on its safety. Therefore, in this study, the toxicity of water extract of CF to ICR mice was investigated. The mice received a single dose of water extract of CF (1,000, 2,000, and 5,000 mg/kg of body weight) via the oral route. Mortality, clinical signs, body weight changes, gross findings, and weights of the principal organs after 14 d were then assessed. The results revealed no adverse effects of CF as determined by clinical signs, body weights, or organ weights and no gross pathological findings in any of the treatment groups. These results suggest that the 50% lethal dose and approximated lethal dose of CF extract is over 5,000 mg/kg. The findings provide scientific evidence for the safety of CFs.

Sea Water Type Classification Around the Ieodo Ocean Research Station Based On Satellite Optical Spectrum (인공위성 광학 스펙트럼 기반 이어도 해양과학기지 주변 해수의 수형 분류)

  • Lee, Ji-Hyun;Park, Kyung-Ae;Park, Jae-Jin;Lee, Ki-Tack;Byun, Do-Seung;Jeong, Kwang-Yeong;Oh, Hyun-Ju
    • Journal of the Korean earth science society
    • /
    • v.43 no.5
    • /
    • pp.591-603
    • /
    • 2022
  • The color and optical properties of seawater are determined by the interaction between dissolved organic and inorganic substances and plankton contained in it. The Ieodo - Ocean Research Institute (I-ORS), located in the East China Sea, is affected by the low salinity of the Yangtze River in the west and the Tsushima Warm Current in the south. Thus, it is a suitable site for analyzing the fluctuations in circulation and optical properties around the Korean Peninsula. In this study, seawater surrounding the I-ORS was classified according to its optical characteristics using the satellite remote reflectance observed with Moderate Resolution Imaging Spectroradiometer (MODIS)/Aqua and National Aeronautics and Space Administration (NASA) bio-Optical Marine Algorithm Dataset (NOMAD) from January 2016 to December 2020. Additionally, the variation characteristics of optical water types (OWTs) from different seasons were presented. A total of 59,532 satellite match-up data (d ≤ 10 km) collected from seawater surrounding the I-ORS were classified into 23 types using the spectral angle mapper. The OWTs appearing in relatively clear waters surrounding the I-ORS were observed to be greater than 50% of the total. The maximum OWTs frequency in summer and winter was opposite according to season. In particular, the OWTs corresponding to optically clear seawater were primarily present in the summer. However, the same OWTs were lower than overall 1% rate in winter. Considering the OWTs fluctuations in the East China Sea, the I-ORS is inferred to be located in the transition zone of seawater. This study contributes in understanding the optical characteristics of seawater and improving the accuracy of satellite ocean color variables.