• 제목/요약/키워드: a conversion factor

검색결과 863건 처리시간 0.031초

Estimating the Soil Volume Conversion Factor of Weathered Ground with Consideration of Field Situations

  • Jin, Kyu-Nam;Cho, Gye-Chun;Lee, Jung-Min;Ryu, Hee-Hwan;Park, Sung-Wook
    • 토지주택연구
    • /
    • 제2권2호
    • /
    • pp.145-155
    • /
    • 2011
  • It is very important for successful construction to estimate the soil volume conversion factor of domestic weathered ground accurately and reasonably. However, it is very difficult to quantify the weathering degree of weathered ground at the field, so that the soil volume conversion factor used in Korea is often dependent upon the standard of foreign countries. Besides, the soil volume conversion factor of domestic weathered ground has been rarely studied and the use and accuracy of the soil volume conversion factor have been questioned persistingly. This study suggests a simple but robust method for estimating the soil volume conversion factor and measuring the weathering degree reasonably, and attempts to establish the utilization of a soil volume conversion factor measurement system based on experimental and analytical results. We made relationship between electrical resistivity and weathering degree presented from weathering index obtained through laboratory tests using field samples, and an estimation method of in-situ weathering degree for granites and a calculation method of soil volume conversion factor using electrical resistivity. And also, we suggested the photogrametry measurement-equipment system for measuring the volume of cargo box and the application plan of stand equipment and RFID for calculating the earth volume and distinguishing buggies in order to design the measurement system for soil volume conversion factor applicable to the field. Ultimately, the Weathered Earth-work Management Program (WEMP) was developed, so field managers may easily obtain the information about earth volume and soil volume conversion factor at the weathered ground.

단상 SRM의 제어 모드 변환에 관한 연구 (A Study on the Mode Conversion of Control in the Single Phase Switched Reluctance Motor)

  • 고성철;안준선;김솔;이주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.635-636
    • /
    • 2006
  • A pulse with modulation(PWM) that keeps a constant angle of dwell and adjust duty ratio is a good method to control a speed of SRM. And a method of one pulse control is proper a operation on range of high speed in SRM for a good energy efficiency. Because PWM method is more safety than one pulse method, conversion of those is best choice according the speed range. So, some algorithm is need for smooth conversion of the mode of control. This paper presents a factor of conversion that proper the conversion of control mode between PWM and one pulse method This factor is from estimation of torque and proper at the variable range of conversion and show the better conversion characteristic than constant factor of conversion.

  • PDF

외래⦁입원 환산지수에 기초한 2020년도 환산지수 산출 연구 (A Study on the introduction of the outpatient and inpatient conversion factors in the 2020 Physician Fee Contract)

  • 오동일
    • 한국산학기술학회논문지
    • /
    • 제22권4호
    • /
    • pp.183-194
    • /
    • 2021
  • 본 연구에서는 SGR 모형과 AR 모형으로 부터 개발된 유형별 외래 및 입원 환산지수 분리 모형을 바탕으로 실제 건강보험 진료비 자료를 사용하여 2020년도 환산지수를 추정하였다. 또한 유형별 환산지수 계약 하에서 병원의 단일 환산지수 조정률과 외래 및 입원으로 분리된 복수의 환산지수 조정률을 산출하였다. 마지막으로 환산지수 분리 모형이 의료전달체계를 확립하기 위한 수단의 하나로 효과적으로 사용되기 위한 정책적 방안을 제안하였다. 본 연구의 주요 결론은 다음과 같다. 첫째, r=0.1에서 2020년도 병원의 단일 환산지수 조정률은 2.0%이며 병원의 환산지수를 분리하는 경우 외래 및 입원 환산지수 조정률은 각 각 2.2%, 2.3%로 나타났다. 그리고 조정계수를 활용하여 외래 및 입원 환산지수를 결합하는 방안을 제시하였다. 둘째, 의료전달체계 확립을 위한 조치의 하나로 제안된 가산율 조정 방식 대신에 가산율과 환산지수를 연동하여 운영하는 방안을 제안하였다. 셋째, 병원⦁의원 등 유형별로 외래환산지수, 입원환산지수, 조정계수를 도입하는 것에 추가해 진료량에 대한 목표관리를 가능하게 하는 모형 개발이 필요하다.

원자현미경(AFM)에서 마찰력 측정을 위한 새로운 보정 기술 연구 (A New Method for Lateral Force Calibration in Atomic Force Microscope)

  • 윤의성;김홍준;;공호성
    • Tribology and Lubricants
    • /
    • 제21권5호
    • /
    • pp.221-226
    • /
    • 2005
  • A new calibration method for exact measurement of friction force in atomic force microscope (AFM) is presented. A new conversion factor involves a contact factor affected by tip, cantilever and contact stiffness. Especially the effect of contact stiffness on the conversion factor between lateral force and lateral signal is considered. Conventional conversion factor and a new modified conversion factor were experimentally compared. Results showed that a new calibration method could minimize the effect of normal load on friction force and improve the conventional method. A new method could be applied to the specimens with different physical properties.

효율적 건강보험수가에 기반을 둔 병원 그룹화에 관한 연구 -AHP와 DEA를 이용한 분석- (A Study on the discriminating of the hospitals based on the efficient insurance conversion factor by AHP and DEA)

  • 오동일
    • 한국산학기술학회논문지
    • /
    • 제10권6호
    • /
    • pp.1304-1316
    • /
    • 2009
  • 본 연구는 효율성에 기초한 환산지수의 도입 가능성을 알아보기 위한 기초 연구로 시도되었다. DEA 효율성지표와 환산지수가 전공의 수련교육을 실시하고 있는 60 개 병원을 그룹화하는데 얼마나 유용하게 사용될 수 있는가를 고찰하였다. 이러한 목적을 달성하기 위해 자료수집이 가능한 표본병원의 환산지수와 AHP 개념을 도입해 DEA 모형의 투입변수와 산출변수를 선정하였다. 그 결과 병상규모가 클수록 규모적 비효율성이 큰 것으로 나타났으며 기술적으로 또는 규모적으로 비효율적인 병원일수록 환산지수가 더 큰 것으로 나타났다. 환산지수와 효율성지표는 수련병원을 병원의 종별에 따라 종합전문병원과 종합병원으로 구분하는데 유용하게 사용될 수 있었다. 또한 DEA 효율성을 구하는 과정에서 독립변수로 사용된 투입 산출변수를 판별함수에 도입하였음에도 불구하고 환산지수와 효율성지표는 판별함수를 구성하는 주요 변수로 작용함을 확인하였다. 따라서 만약 모집단을 대표할 수 있는 많은 표본을 기초로 보다 명확한 결과를 얻을 수 있다면 건강보험의 수가계약제 하에서 효율성 개념을 바탕으로 한 환산지수계약의 도입을 신중하게 고려해 볼 수 있다.

원자 현미경에서 마찰력 측정을 위한 새로운 실험 기법 (A New Experimental Technique for Calibration of Frictional Force in Atomic Force Microscopy)

  • 최덕현;황운봉;윤의성
    • 대한기계학회논문집A
    • /
    • 제28권12호
    • /
    • pp.1906-1913
    • /
    • 2004
  • A new method has been proposed for the calibration of frictional forces in atomic force microscopy. Angle conversion factor is defined using the relationship between torsional angle and frictional signal. Once the factor is obtained from a cantilever, it can be applied to other cantilevers without additional experiments. Moment balance equations on the flat surface and top edge of a commercial step grating are used to obtain angle conversion factor. Proposed method is verified through another step grating test and frictional behavior of Mica.

원자 현미경에서 마찰력 측정을 위한 새로운 실험 기법 (A New Experimental Technique for Calibration of Frictional Force in Atomic Force Microscopy)

  • 최덕현;황운봉;윤의성;김준원;김동식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.846-851
    • /
    • 2004
  • A new method has been proposed for the calibration of frictional forces in atomic force microscopy. Angle conversion factor is defined using the relationship between torsional angle and frictional signal. Once the factor is obtained from a cantilever, it can be applied to other cantilevers without additional experiments. Moment balance equations on the flat surface and top edge of a commercial step grating are used to obtain angle conversion factor. Proposed method is verified through another step grating test and frictional behavior of Mica.

  • PDF

건강보험 의료행위의 비용구조 (Cost Structure of Medical Services in Korean National Health Insurance)

  • 오영숙;강길원
    • 보건행정학회지
    • /
    • 제20권2호
    • /
    • pp.40-52
    • /
    • 2010
  • Health insurance fees are set by relative value scales and conversion factors. Since 2008 the conversion factor has been classified into 7 according to the provider type, and a separate contract has been made respectively. As such classification of the conversion factor reflects only the different characteristics of providers, however, further classification to reflect the different cost structures of providers is proposed. Cost varies according to the type of not only providers but also services each provider supply. In fact different cost structures of providers are the result of their different services. This study analyzed the cost structure of medical services to propose a new approach to the classification of the conversion factor. This study analyzed the cost structure of medical services using cost data constructed in the revision study of relative value scales. The cost data consist of doctor's fee, support staff's fee, cost of medical equipments, cost of medical supplies and indirect cost. The proportion of each cost component to the total cost was analyzed in terms of service department and service type. 72 service groups are defined in terms of the combination of service department and service type. Through cluster analysis, 72 service groups were reduced into 7 clusters each of which has a similar cost structure. Conversion factor is contracted annually to reflect the change in the cost of providing medical services. So the classification of conversion factor has to be based on the cost structures of medical services, not the characteristics of providers. Service clusters derived in this study can be used as a new classification for health insurance fee contract.

고역률을 갖는 단일 전력변환 AC-DC 컨버터 (Single Power-conversion AC-DC Converter with High Power Factor)

  • 조용원;박천윤;권봉환
    • 전력전자학회논문지
    • /
    • 제19권1호
    • /
    • pp.23-30
    • /
    • 2014
  • This paper proposes a single power-conversion ac-dc converter with a dc-link capacitor-less and high power factor. The proposed converter is derived by integrating a full-bridge diode rectifier and a series-resonant active-clamp dc-dc converter. To obtain a high power factor without a power factor correction circuit, this paper proposes a suitable control algorithm for the proposed converter. The proposed converter provides single power-conversion by using the proposed control algorithm for both power factor correction and output control. Also, the active-clamp circuit clamps the surge voltage of switches and recycles the energy stored in the leakage inductance of the transformer. Moreover, it provides zero-voltage turn-on switching of the switches. Also, a series-resonant circuit of the output-voltage doubler removes the reverse-recovery problem of the output diodes. The proposed converter provides maximum power factor of 0.995 and maximum efficiency of 95.1% at the full-load. The operation principle of the converter is analyzed and verified. Experimental results for a 400W ac-dc converter at a constant switching frequency of 50kHz are obtained to show the performance of the proposed converter.

두 종류의 부하곡선에 관한 공급지장시간기대치(LOLE)의 상호 변환관계성 (Conversion Function and Relationship of Loss of Load Expectation Indices on Two Kinds of Load Duration Curve)

  • 이연찬;오웅진;최재석;차준민;최홍석;전동훈
    • 전기학회논문지
    • /
    • 제66권3호
    • /
    • pp.475-485
    • /
    • 2017
  • This paper develops a conversion function and method transforming from daily peak load curve used $LOLE_D$ [days/year] to hourly load curve used $LOLE_H$[hours/year]and describes relationship between $LOLE_D$ [days/year] and $LOLE_H$ [hours/year]. The indices can not only be transformed just arithmetically but also have different characteristics physically because of using their different load curves. The conversion function is formulated as variables of capacity and forced outage rate of generator, hourly load daily load factor and daily peak load yearly load factor, etc. Therefore, the conversion function (${\gamma}={\varphi}$(.)) can not be simple. In this study, therefore, the function is formulated as linear times of separated two functions. One is an exponential formed conversion function of daily load factor. Another is formulated with an exponential typed conversion function of daily peak load yearly load factor. Futhermore, this paper presents algorithm and flow chart for transforming from $LOLE_D$[days/year] to $LOLE_H$[hours/year]. The proposed conversion function is applied to sample system and actual KPS(Korea Power System) in 2015. The exponent coefficients of the conversion functions are assessed using proposed method. Finally, assessment errors using conversion function for case studies of sample system and actual system are evaluated to certify the firstly proposed method.