• 제목/요약/키워드: a angle detector

검색결과 177건 처리시간 0.034초

Updated Comparison Study of Extensive Air Shower Simulations with COSMOS and CORSIKA

  • 김지희;노순영;류동수
    • 천문학회보
    • /
    • 제36권2호
    • /
    • pp.128.2-128.2
    • /
    • 2011
  • Experiments to study high-energy cosmic rays (CRs) employ Monte Carlo codes for extensive air shower (EAS) simulations to figure out the properties of CRs. COSMOS and CORSIKA among EAS simulation codes are currently being used to analyze the data of the Telescope Array experiment. We have generated a library of about 10,000 simulated EASs with the primary energy ranging from $10^{18.5}eV$ to $10^{20}eV$ and the zenith angle of primary particles ranging from 0 to 45 degree for proton and iron primaries. We have compared the results predicted by CORSIKA and COSMOS under the same condition. In this talk, we show the differences in the energy spectra at the ground, the longitudinal shower profile as a function of atmospheric depth, the Calorimetric energy, and the Xmax distribution. We also discuss the lateral distribution function obtained from GEANT4 simulations which is being used to measure the detector response.

  • PDF

Short Wave Infrared Imaging for Auroral Physics and Aeronomy Studies

  • Trond S. Trondsen;John Meriwether;Craig Unick;Andrew Gerrard;Matthew Cooper;Devin Wyatt
    • Journal of Astronomy and Space Sciences
    • /
    • 제41권2호
    • /
    • pp.121-138
    • /
    • 2024
  • Advances in solar-terrestrial physics are generally linked to the development of innovative new sensor technologies, affording us ever better sensitivity, higher resolution, and broader spectral response. Recent advances in low-noise InGaAs sensor technology have enabled the realization of low-light-level scientific imaging within the short-wave infrared (SWIR) region of the electromagnetic spectrum. This paper describes a new and highly sensitive ultra-wide angle imager that offers an expansion of auroral and airglow imaging capabilities into the SWIR spectral range of 900-1,700 nm. The imager has already proven successful in large-area remote sensing of mesospheric temperatures and in providing intensity maps showing the propagation and dissipation of atmospheric gravity waves and ripples. The addition of an automated filter wheel expands the range of applications of an already versatile SWIR detector. Several potential applications are proposed herein, with an emphasis on auroral science. The combined data from this type of instrument and other existing instrumentation holds a strong potential to further enhance our understanding of the geospace environment.

Current Status of the Synchrotron Small-Angle X-ray Scattering Station BL4C1 at the Pohang Accelerator Laboratory

  • Jorg Bolze;Kim, Jehan;Huang, Jung-Yun;Seungyu Rah;Youn, Hwa-Shik;Lee, Byeongdu;Shin, Tae-Joo;Moonhor Ree
    • Macromolecular Research
    • /
    • 제10권1호
    • /
    • pp.2-12
    • /
    • 2002
  • The small-angle X-ray scattering (SAXS) beamline BL4C1 at the 2.5 GeV storage ring of the Pohang Accelerator Laboratory (PAL) has been in its first you of operation since August 2000. During this first stage it could meet the basic requirements of the rapidly growing domestic SAXS user community, which has been carrying out measurements mainly on various polymer systems. The X-ray source is a bending magnet which produces white radiation with a critical energy of 5.5 keV. A synthetic double multilayer monochromator selects quasi-monochromatic radiation with a bandwidth of ca. 1.5%. This relatively low degree of monochromatization is sufficient for most SAXS measurements and allows a considerably higher flux at the sample as compared to monochromators using single crystals. Higher harmonics from the monochromator are rejected by reflection from a flat mirror, and a slit system is installed for collimation. A charge-coupled device (CCD) system, two one-dimensional photodiode arrays (PDA) and imaging plates (IP) are available its detectors. The overall performance of the beamline optics and of the detector systems has been checked using various standard samples. While the CCD and PDA detectors are well-suited for diffraction measurements, they give unsatisfactory data from weakly scattering samples, due to their high intrinsic noise. By using the IP system smooth scattering curves could be obtained in a wide dynamic range. In the second stage, stating from August 2001, the beamline will be upgraded with additional slits, focusing optics and gas-filled proportional detectors.

X선 진단영역 에너지 측정을 위한 Photo-Diode 선량계(PD-2000)의 개발 (The development of photo-diode dosimeter(PD-2000) for the diagnostic X-ray Energy)

  • 김성철;이우철;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제23권2호
    • /
    • pp.27-32
    • /
    • 2000
  • It was produced radiation dosimeter used photo-diodes for which ionization by x-ray was applied and evaluated the value of utility in clinics as compared with ion-chamber. The result obtained were as follows : 1. Comparison of ion-chamber with photo-diode dosimeter's x-ray output by the change of x-ray tube voltage, and the ratio of ion-chamber to diode was $0.96{\sim}1.02$ which was not affected by x-ray beam quality. 2. The ratio of ion-chamber to diode was 0.96 by change of tube current and 0.97 by change of exposure time that is not affected by x-ray quantity. 3. The ratio of ion-chamber to diode was $0.97{\sim}1.04$ by thickness and $0.93{\sim}1.10$ by radiation field that is little affected by second ray quantity. 4. Reproducibility of photo-diode dosimeter was 0.011(CV) and it is a good result. 5. Photo-diode dosimeter was affected by the surface angle of detector over 30 degrees. Produced dosimeter was small, light, and meets good result compared with ionization chamber. It was expected come into wide use in clinic.

  • PDF

특이값분해 기반 동적의료영상 재구성기법의 특징 파악을 위한 시뮬레이션 연구 (Simulation Study for Feature Identification of Dynamic Medical Image Reconstruction Technique Based on Singular Value Decomposition)

  • 김도휘;정영진
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권2호
    • /
    • pp.119-130
    • /
    • 2019
  • Positron emission tomography (PET) is widely used imaging modality for effective and accurate functional testing and medical diagnosis using radioactive isotopes. However, PET has difficulties in acquiring images with high image quality due to constraints such as the amount of radioactive isotopes injected into the patient, the detection time, the characteristics of the detector, and the patient's motion. In order to overcome this problem, we have succeeded to improve the image quality by using the dynamic image reconstruction method based on singular value decomposition. However, there is still some question about the characteristics of the proposed technique. In this study, the characteristics of reconstruction method based on singular value decomposition was estimated over computational simulation. As a result, we confirmed that the singular value decomposition based reconstruction technique distinguishes the images well when the signal - to - noise ratio of the input image is more than 20 decibels and the feature vector angle is more than 60 degrees. In addition, the proposed methode to estimate the characteristics of reconstruction technique can be applied to other spatio-temporal feature based dynamic image reconstruction techniques. The deduced conclusion of this study can be useful guideline to apply medical image into SVD based dynamic image reconstruction technique to improve the accuracy of medical diagnosis.

디지털 방사선시스템에서 영상증강 파라미터의 영상특성 평가 (Image Quality Evaluation of Medical Image Enhancement Parameters in the Digital Radiography System)

  • 김창수;강세식;고성진
    • 한국콘텐츠학회논문지
    • /
    • 제10권6호
    • /
    • pp.329-335
    • /
    • 2010
  • 디지털 방사선시스템에서의 의료영상 획득의 방법은 X선을 조사하고, 반도체 디텍터(Detector)를 이용하여 직접 및 간접으로 변환하여 기존 업체마다 여러 가지 알고리즘을 적용하여 적절한 이미지 프로세싱을 거쳐서 임상의 적정한 영상을 획득한다. 방사선과에서 적절한 의료 영상 형성을 위하여 적용하는 이미지 프로세싱 파라미터(Image Processing Parameters)는 Edge, Frequency, Contrast, Latitude, LUT, Noise 등의 영상 증강의 과정은 기술력 및 업체 알고리즘에 따라 다르게 적용되고 있다. 따라서 본 논문에서는 디지털 방사선 환경에서의 최종의 임상 영상을 위한 이미지 증강의 파라미터들의 적정 세팅 값의 기준을 제시하고자 한다. 그리고 각 병원들의 의료 영상을 바탕으로 이미지 프로세싱 파라미터들을 변화하여 각 파라미터들의 세부적인 기준 세팅값을 연구하며, 실제적인 파라미터 변화에 대한 적합한 의료 영상을 디지털방사선시스템의 영상 평가 방법을 도식화하여 결과를 제시하고, 향후 임상에서 적응 및 활용 가능한 객관적인 영상 파라미터에 대한 특성 평가의 응용을 정립하고자 한다. 또한 다양한 표본 병원의 디지털 방사선 환경에서 적정 파라미터 값들을 조사하여 임상에서 영상의 화질에 미치는 영향으로 특성 평가의 객관적인 기준의 변조전달함수(MTF)의 공간해상력을 제시하고 한다.

볼트풀림에 의한 터미널 블록의 접속부 발열 위험성 분석 (Analysis of the Risk of Heat Generation due to Bolt Loosening in Terminal Block Connector Parts)

  • 연영모;김승희
    • 한국화재소방학회논문지
    • /
    • 제34권3호
    • /
    • pp.67-75
    • /
    • 2020
  • 본 연구는 산업현장에서 사용되는 분전반 내 터미널 블록의 탄화 사고를 예방하기 위한 목적으로, 전선 접속부 볼트의 이상(Abnormal) 풀림 각도에 따라 변화하는 정상전류 및 과전류의 접속부 발열 위험성을 확인하고 열적 특성을 통해 위험성을 분석하였다. 이를 위하여 터미널 블록에 Resistance temperature detector (RTD) 센서 보드를 설치하여 실시간으로 터미널 블록의 발열 온도와 온도의 변화를 측정하는 새로운 기법을 적용하였다. 실험 결과 정격 전류가 작은 터미널 블록 모델의 발열 온도가 높게 나타남에 따라 부하전류에 따른 터미널 블록 용량 선정의 중요성을 확인하였다. 또한 정격전류가 높은 터미널 블록의 정격 전류가 높을수록, 이상 풀림 정도가 클수록 탄화점이 빨라짐을 확인하였다. 이러한 발열 온도 모니터링을 통해서 실시간 발열 온도를 측정할 수 있었고 열적 분석을 통해서 단계별 위험수위 설정이 가능함을 확인할 수 있었다. 본 연구의 탄화 위험성 측정 및 분석 결과는 탄화로 인한 화재 위험성에 대한 응용 연구의 이론적 기초를 제공할 수 있다. 또한 본 연구에서 새롭게 적용한 온도 센서 보드를 활용한 열화 측정 방법은 위험수준관리 및 전기적 접촉 불량으로 인한 화재 예방 활동에 광범위하게 적용 가능할 것으로 사료된다.

2차원 Magnetic Fluxgate센서의 구현에 관한 연구 (A Study on the Implementation of the 2-Dimension Magnetic Fluxgate Sensor)

  • 박용우;김남호;류지구
    • 센서학회지
    • /
    • 제11권2호
    • /
    • pp.67-76
    • /
    • 2002
  • 본 연구에서는 페라이트 링 코어를 이용한 2차원 fluxgate 센서를 제안하였으며, 본 fluxgate 센서 시스템은 2차원 자장을 측정할 수 있는 센서와 그 센서를 구동하기 위한 구동회로, 그리고 신호처리회로 등으로 구성하였다. 신호 검출 방법으로는 우수고조파 성분 검출을 위해 PSD(phase sensitivity detector) 회로를 사용하였으며, 기존의 제 2고조파 검출법과 비교하기 위해서 pick-up 코일 출력전압의 제 2고조파 성분을 FFT 스펙트럼 분석기를 사용하여 측정하였고, 이렇게 측정된 제 2고조파 성분의 전압과 PSD 단의 출력전압을 비교하였다. 그 결과 여자전류의 증가에 따라 센서의 출력전압도 증가하였으며, 구동주파수에 따른 PSD 단의 출력전압은 주파수가 1.5[kHz]일 때까지는 증가하였지만, 그 이상의 주파수에서는 감소함을 보였다. 그리고 pick-up 코일의 제 2고조파 성분의 전압은 계속 증가함을 보였다. 센서의 최대감도는 구동주파수 1.5 [kHz], 구동전류 2 [App]에서 최대값을 보였으며 감도는 약 1580 [V/T]였다. 센서의 비선형계수는 3 [G] 이내에서 제 2고조파 성분의 전압인 경우 약 1 [%]이내였으며, PSD 단 이후는 약 2.3 [%]이내였다. 그리고 각도오차는 약 ${\pm}2$ [%/FS]이내였다.

모사된 컴프턴 카메라 투사데이터의 재구성을 위한 OSEM 알고리즘의 부분집합 구성법 비교 연구 (A Comparative Study of Subset Construction Methods in OSEM Algorithms using Simulated Projection Data of Compton Camera)

  • 김수미;이재성;이미노;이주한;김중현;김찬형;이춘식;이동수;이수진
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제41권3호
    • /
    • pp.234-240
    • /
    • 2007
  • 목적: 본 연구에서는 컴프턴 카메라의 투사데이터를 재구성하기 위하여 부분집합 개수에 비례하여 고속화된 수렴속도를 보이는 통계학적 영상재구성 방법인 OSEM 알고리즘을 적용하였다. 또한 연산시간 및 퍼센트 오차 측면에서 컴프턴 투사데이터의 부분집합 구성 시 여러 구분방법에 대한 비교연구를 수행함으로써 컴프턴 투사데이터의 최적화된 OSEM 알고리즘을 제안하고자 하였다. 대상 및 방법: 산란부와 흡수부로 구성된 컴프턴 카메라의 투사데이터를 재구성하기 위하여 단순역투사, 기댓값 최대화 방법과 OSEM 알고리즘을 구현하였다. 그리고 OSEM의 경우 컴프턴 투사데이터는 산란부 및 흡수부의 검출위치 및 산란각에 따라 부분 집합으로 구분하였다. EM 알고리즘은 64번의 반복연산을 수행하였으며 OSEM은 16개의 부분집합에 대해 4번의 반복연산을 수행하였다. 각 재구성 방법과 부분집합 구분방법에 대한 정량적 성능평가를 위하여 계산 시간과 퍼센트 오차를 측정하였다. 결과: SBP 방법에 비해 모든 통계학적 영상재구성 방법의 결과들이 보다 정확하였다. 64번 반복연산을 수행한 EM 알고리즘에 비해 4번의 반복연산과 16개의 부분집합을 가지는 모든 OSEM 알고리즘은 유사한 퍼센트 오차를 나타내면서 14배 빠른 수렴속도를 보였다. OSEM의 경우, 부분집합의 구분방법에 따라 연산속도와 재구성된 영상의 정확도 면에서는 거의 차이가 없었다. 결론: 본 연구의 실험 결과를 통하여 핵의학 영상 분야에서 사용하는 OSEM 알고리즘이 컴프턴 카메라에 대한 재구성 알고리즘으로 유용함을 확인하였으며 OS-EM 방법은 EM에 비해 유사한 결과영상을 재구성하면서 14배 빠른 수렴속도를 보이며 컴프턴 투사데이터를 부분집합으로 구분 시 검출위치와 산란각을 모두 이용하는 것이 가장 효율적인 것으로 간주된다.NIS와 EGFP의 이중 리포터 유전자를 가지고 있는 HepG2 세포주가 성공적으로 만들어졌다. 세포의 약 50% 정도가 형광 현미경 아래에서 관찰되었다. NIS 유전자의 발현은 역전사효소 중합효소 연쇄반응 실험을 통해서 확인하였고, NIS가 발현된 세포의 방사능옥소 섭취량은 대조군에 비하여 약 9배 정도 높게 나타났다. 방사능옥소 유출량 실험에서는 약 9분에 반 정도의 옥소가 유출되는 것이 확인되었다. 구축된 세포주를 이식한 후 획득한 형광 영상, 감마카메라과 소동물용 PET 영상에서는 반대쪽의 대조군 세포를 이식한 것에 비하여 뚜렷한 형광신호가 보였고, 더 높은 방사능옥소 섭취가 확인되었다. 결론: NIS와 EGFP의 이중 리포터 유전자를 가지는 간암 세포주가 성공적으로 구축되었고, 소동물에서 두 유전자를 각각 치료용 리포터 유전자와 영상 리포터 유전자로의 사용이 가능할 것이라고 생각된다.타내는 중요한 효소로 인정되고 있으며, 조직의 손상, 발암, 염증, 성인병 및 노화 등과 같은 여러 가지 유해 작용을 일으킨다. 정상군에 비해 대조군은 1.74배 수치가 증가되었으며, RCM투여군의 대조군과 비교 시 57.4% 감소되는 효과를 볼 수 있었다. 본 연구는 LPS로부터 유도된 산화적 스트레스에 대한 복분자의 선투여 후 예방효과를 알아보았다. 생약재의 일종인 복분자의 경우 LPS로 유도된 산화적 스트레스 억제 및 지질대사로부터의 개선 효과가 있는 것으로 판단되며 지질과산화에 대해서 강한 억제 활성을 나타내는 것을 알 수 있었다. 이러한 결과로 복분자는 생활 습관병의 예방과 개선에 유효한 것으로 사료되었으며, 지질대사와 과산화지표의 검증을 통해 기능성 식품소재로 활용될 수 있음을 보여주었다.로서 역시 CTV 치료계획에서 적게 조사되었다(p=0.005). 기존의 ICRU 치료계획은

검출기 측정방법에 따른 PAE값의 변화 (Change of PAE according to Detector Measurement Method)

  • 임인철
    • 한국콘텐츠학회논문지
    • /
    • 제10권6호
    • /
    • pp.307-311
    • /
    • 2010
  • 본 연구는 검출기 측정방법에 따라 관전압 정확도 검사결과인 PAE값이 어떻게 달라지는지 알아보고자 한다. 실험방법으로는 측정거리와 X선관 각도, 방향에 따른 PAE값의 변화실험에서는 초점과 측정기간의 거리를 100cm, 80cm, 60cm에 위치시킨 상태에서 관전압지시치는 70kVp, X선관 각도는 음극, 양극측으로 $5^{\circ},\;10^{\circ},\;15^{\circ},\;20^{\circ},\;25^{\circ},\;30^{\circ}$로 맞추어 측정하고, 관전압지시치에 따른 PAE값의 변화실험에서는 관전압 60kVp, 70kVp, 80kVp, 90kVP, 100kVp를 설정하고 소초점과 대초점을 전환하며 측정하였다. 측정거리와 X선관 각도, 방향에 대한 PAE값의 결과를 보면 100cm일 경우에는 음극측에서 전체적으로 PAE값이 높게 나타났으며 80cm, 60cm일 경우에는 양극측에서 높게 나타났다. PAE값의 변동율은 100cm일 경우 음, 양극측 모두 안정적으로 나타났으며 80cm, 60cm일 경우에는 불균형적으로 나타났다. 관전압지시치에 따른 PAE값의 결과로는 대초점보다는 소초점이 높게 나타났으며, 지시치가 클수록 높게 나타났다. 오차 범위는 지시치가 클수록 적게 나타났다.