Browse > Article
http://dx.doi.org/10.5392/JKCA.2010.10.6.329

Image Quality Evaluation of Medical Image Enhancement Parameters in the Digital Radiography System  

Kim, Chang-Soo (부산가톨릭대학교 보건과학대학 방사선학과)
Kang, Se-Sik (부산가톨릭대학교 보건과학대학 방사선학과)
Ko, Seong-Jin (부산가톨릭대학교 보건과학대학 방사선학과)
Publication Information
Abstract
Digital imaging detectors can use a variety of detection materials to convert X-ray radiation either to light or directly to electron charge. Many detectors such as amorphous silicon flat panels, CCDs, and CMOS photodiode arrays incorporate a scintillator screen to convert x-ray to light. The digital radiography systems based on semiconductor detectors, commonly referred to as flat panel detectors, are gaining popularity in the clinical & hospital. The X-ray detectors are described between a-Silicon based indirect type and a-Selenium based direct type. The DRS of detectors is used to convert the x-ray to electron hole pairs. Image processing is described by specific image features: Latitude compression, Contrast enhancement, Edge enhancement, Look up table, Noise suppression. The image features are tuned independently. The final enhancement result is a combination of all image features. The parameters are altered by using specific image features in the different several hospitals. The image in a radiological report consists of two image evaluation processes: Clinical image parameters and MTF is a descriptor of the spatial resolution of a digital imaging system. We used the edge test phantom and exposure procedure described in the IEC 61267 to obtain an edge spread function from which the MTF is calculated. We can compare image in the processing parameters to change between original and processed image data. The angle of the edge with respect to the axes of detector was varied in order to determine the MTF as a function of direction. Each MTF is integrated within the spatial resolution interval of 1.35-11.70 cycles/mm at the 50% MTF point. Each image enhancement parameters consists of edge, frequency, contrast, LUT, noise, sensitometry curve, threshold level, windows. The digital device is also shown to have good uniformity of MTF and image parameters across its modality. The measurements reported here represent a comprehensive evaluation of digital radiography system designed for use in the DRS. The results indicate that the parameter enables very good image quality in the digital radiography. Of course, the quality of image from a parameter is determined by other digital devices in addition to the proper clinical image.
Keywords
Digital Radiography System; Image Quality; MTF; Image Enhancement Parameters;
Citations & Related Records
연도 인용수 순위
  • Reference
1 이대형, DR Detector의 Raw Data 분석을 통한 NPS, MTF, DQE 측정과 성능평가연구, 고려대학교 의용과학대학원 석사논문, pp.15-29, 2008.
2 석대우, MTF, NPS, DQE 측정을 통한 비정질 셀레늄 기반 디지털 방사선 검출기의 성능 평가에 관한 연구, 인제대학교 의용공학과 대학원, pp.8-68, 2004.
3 이경하, 변조전달함수 측정에 의한 X-선 영상 시스템의 공간해상도 평가 기법에 관한 연구, 연세대학교 보건환경대학원 석사논문, pp.10-27, 2006.
4 E. Berry, A practical Approach to Medical Image Processing, Taylor & Francis, pp.121-148. 2008.
5 P. R. Granfors and R. Aufrichting, "Performance of a 41×41cm2 amorphous silicon flat panel x-ray detector designed for angiographic and R&F imaging applications," Medical Physics, Vol.30, No.10, pp.2715-2726, 2003.   DOI   ScienceOn
6 N. Reznik, P. T. Komljenovic, S. Germann, J. A. Rowlands, "Digital radiograhpy using amorphous selenium: Photoconductively switch(PAS) readout system," Medical Physics, Vol.35, No.3, pp.1039-1050, 2008.   DOI   ScienceOn
7 K. S. Park, J. M. Park, Y. S. Yoon, B. W. Kim, and J. Y. Kang, "Semiconductor Detectors for Radiation Imaging Applications," ETRI Vol.22, No.5, pp.95-107, 2007.