• Title/Summary/Keyword: X-ray shield

검색결과 51건 처리시간 0.031초

A Copper Shield for the Reduction of X-γ True Coincidence Summing in Gamma-ray Spectrometry

  • Byun, Jong-In
    • Journal of Radiation Protection and Research
    • /
    • 제43권4호
    • /
    • pp.137-142
    • /
    • 2018
  • Background: Gamma-ray detectors having a thin window of a material with low atomic number can increase the true coincidence summing effects for radionuclides emitting X-rays or gamma-rays. This effect can make efficiency calibration or spectrum analysis more complicated. In this study, a Cu shield was tested as an X-ray filter to neglect the true coincidence summing effect by X-rays and gamma-rays in gamma-ray spectrometry, in order to simplify gamma-ray energy spectrum analysis. Materials and Methods: A Cu shield was designed and applied to an n-type high-purity germanium detector having an $X-{\gamma}$ summing effect during efficiency calibration. This was tested using a commercial, certified mixed gamma-ray source. The feasibility of a Cu shield was evaluated by comparing efficiency calibration results with and without the shield. Results and Discussion: In this study, the thickness of a Cu shield needed to avoid true coincidence summing effects due to $X-{\gamma}$ was tested and determined to be 1 mm, considering the detection efficiency desired for higher energy. As a result, the accuracy of the detection efficiency calibration was improved by more than 13% by reducing $X-{\gamma}$ summing. Conclusion: The $X-{\gamma}$ summing effect should be considered, along with ${\gamma}-{\gamma}$ summing, when a detection efficiency calibration is implemented and appropriate shielding material can be useful for simplifying analysis of the gamma-ray energy spectra.

The reduction methods of operator's radiation dose for portable dental X-ray machines

  • Cho, Jeong-Yeon;Han, Won-Jeong
    • Restorative Dentistry and Endodontics
    • /
    • 제37권3호
    • /
    • pp.160-164
    • /
    • 2012
  • Objectives: This study was aimed to investigate the methods to reduce operator's radiation dose when taking intraoral radiographs with portable dental X-ray machines. Materials and Methods: Two kinds of portable dental X-ray machines (DX3000, Dexcowin and Rextar, Posdion) were used. Operator's radiation dose was measured with an 1,800 cc ionization chamber (RadCal Corp.) at the hand level of X-ray tubehead and at the operator's chest and waist levels with and without the backscatter shield. The operator's radiation dose at the hand level was measured with and without lead gloves and with long and short cones. Results: The backscatter shield reduced operator's radiation dose at the hand level of X-ray tubehead to 23 - 32%, the lead gloves to 26 - 31%, and long cone to 48 - 52%. And the backscatter shield reduced operator's radiation dose at the operator's chest and waist levels to 0.1 - 37%. Conclusions: When portable dental X-ray systems are used, it is recommended to select X-ray machine attached with a backscatter shield and a long cone and to wear the lead gloves.

임산부 흉부촬영 시 복부차폐의 적정성 평가 (Adequacy Assessment to Abdomen Shield of Pregnant X-ray Chest PA)

  • 김기진;김가중
    • 대한안전경영과학회지
    • /
    • 제17권4호
    • /
    • pp.207-212
    • /
    • 2015
  • When performing Chest x-ray examination to pregnant woman, normally we shield back side of abdomen. In this situation, scattered rays made by equipment and surrounding structure can enter front side of abdomen. Therefore, in this study, we evaluate suitability of abdomen shield especially to pregnant woman. In case of One shielding material placed back of abdomen, the measured value is $0.676{\pm}0.19uSv/hr$. Two shielding material is $0.764{\pm}0.04uSv/hr$. Three is $0.685{\pm}0.16uSv/hr$. The exposure dose inferred in this study does not excess annual effective dose limit. But It is not mean absolute safety. So we have to minimize occurrence of stochastic effect of radiosensitivity by shielding front side of abdomen of pregnant woman in clinic.

일체형 방어벽 제작을 통한 이동형 엑스선 발생기의 차폐능 평가 (Shielding Capability Evaluation of Mobile X-ray Generator through the Production assembled Shield)

  • 김승욱;안병주
    • 한국방사선학회논문지
    • /
    • 제12권7호
    • /
    • pp.895-908
    • /
    • 2018
  • 의료방사선의 관리에서 가장 중요한 사항은 진료의 적정성을 확보하면서 방사선위해를 최소화하는 것이다. 국제원자력기구는 진단방사선 분야의 선량 감소 방법에 대한 지침서를 만들어 환자피폭선량을 측정하여 각 국가에 사용하도록 권고하고 있다. 또한 국내에서도 우리나라의 실정에 맞게 각 촬영마다 환자 피폭 선량값을 연구하여 진단참고준위를 제시하였다.환자가 질병 때문에 방사선 진료를 받는 것은 방사선 때문에 일어날 수 있는 위해보다 그것으로 얻어지는 이익이 크기 때문이다. 병실 이동검사와 같이 자신의 질병과 무관하게 방사선에 노출되는 환자 및 보호자들의 피폭을 줄이기 위해서는 환자, 방사선사, 의사 및 의료기관의 노력이 가장 중요하다.이에 본 연구에서는 개선방안의 일환으로 MG로 병실의 이동 검사에 대한 문제점을 제시하고 이 문제점을 근거로 하여 산란선으로 예상되는 공간선량률을 분석하였다. MG에 자체 개발한 방어벽을 설치하여 방어벽 설치 전후의 공간선량률을 측정하여 그 감소율을 분석하였다. 최종적으로 이 자료들을 종합하여 MG에 방어벽을 부착하여 방사선사의 병실이동에 대한 부담감의 최소화, 병실 이동검사로 인한 방사선사, 환자 및 보호자를 방사선 노출로부터 보호하고, 검사로 인한 주위 환자 및 보호자의 불편을 최소화하는데 의의가 있다. 이와 같은 개선안에 대해 보다 효율적인 시행을 위하여 MG에 대한 새로운 법 제도가 마련되면, 향후 예상되는 비용, 인력, 고객만족도 및 더욱 더 안정적인 피폭감소방안이 정착될 것이라 사료된다.

Constraining the shielded wind scenario in PG 2112+059

  • Saez, Cristian;Brandt, Niel;Bauer, Franz;Hamann, Fred;Chartas, George;Gallagher, Sarah
    • 천문학회보
    • /
    • 제41권1호
    • /
    • pp.36.1-36.1
    • /
    • 2016
  • The physical scenario describing the origin of quasar winds remains largely unsettled due to our failure to account for X-ray weak BAL quasars. We approach this problem by studying the relation between the inner part of the outflow which is likely to be shielding the X-ray emission and thereby helping to drive the UV winds characterised by broad absorption lines (BALs). In particular, we aim to probe the wind-shield connection in the highly X-ray variable BAL quasar PG 2112+059, which has exhibited periods of X-ray weakness and X-ray normality in the past. A set of two 20 ks Chandra observations and two contemporaneous HST observations, separated by at least eight months, combined with a nearly simultaneous archival Chandra-HST observation from 2002, afford us a unique opportunity to study the connection between the shield (which is thought to be responsible for the X-ray absorption) and the ionisation state of the wind (observed as UV BAL features; e.g., C IV and O VI lines) over various timescales.

  • PDF

3차원 프린팅 기술을 이용한 차폐체 제작 및 유용성 평가 (Usefulness Evaluation and Fabrication of the Radiation Shield Using 3D Printing Technology)

  • 장희민;윤준
    • 한국방사선학회논문지
    • /
    • 제13권7호
    • /
    • pp.1015-1024
    • /
    • 2019
  • 최근 의료분야에서 X선은 질병의 진단 및 치료영역에서 필수적으로 요구되며, 영상의학 기술의 발전과 더불어 X선의 이용은 지속적으로 증가하는 추세지만, X선은 방사선 피폭의 단점을 가지고 있다. 방사선피폭을 방어하기 위해 임상에서는 납 방호도구를 사용하지만 납은 중금속으로 분류되어 납중독 등 인체에 유해한 반응을 일으킬 수 있다. 따라서 본 연구는 FDM(Fused Deposition Modeling)방식의 3차원 프린터의 재료를 이용하여 제작한 차폐체의 유용성을 알아보고자 한다. 필라멘트의 선감약계수를 확인하기 위해 PLA, XT-CF20, Wood, Glow, Brass를 이용해 팬텀을 제작 하고, CT scan을 하였다. 그리고 100 × 100 × 2 mm 크기의 차폐 시트를 모델링하고, 진단용 X선발생장치와 조사선량계를 이용하여 선량 및 차폐율을 측정하였으며, 납 방호도구와의 차폐율을 비교하였다. 실험결과 Brass의 CT number가 가장 높게 측정되어 Brass를 이용하여 차폐시트를 제작하였으며, 진단용 X선발생장치로 확인한 결과 100 kV, 40 mAs 조건으로 X선 조사 시 6 mm 두께의 차폐시트에서 차폐율이 90 % 이상으로 측정되어 apron 0.25 mmPb보다 차폐율이 높은 것을 확인하였다. 본 연구의 결과 3차원 프린팅 기술로 제작한 차폐체가 진단용 X선 영역에서 높은 차폐율을 보이는 것을 확인하였으며, 납 방호도구와의 비교를 통하여 납을 대체하여 방사선 방호도구로서의 가능성을 알 수 있었다.

산화철, 알루미나를 이용한 X선 차폐체 개발 및 성능 평가 (Development and Performance Evaluation of X-Ray Shields using Fe2O3 and Al2O3)

  • 양희수;김지환;전민철
    • 미래기술융합논문지
    • /
    • 제1권2호
    • /
    • pp.19-25
    • /
    • 2022
  • 방사선 차폐 물질인 납을 대신하여 싸고 친환경적인 산화철, 알루미나로 차폐체를 제작 후 차폐체의 성능을 평가하고자 한다. 산화철과 알루미나 각각 석고와 혼합하여 차폐체를 제작 이후 X-ray Tube를 이용하여 석고보드, 납복과 비교하여 성능을 평가한다. 관전압에 변화를 주며 실험한 결과 알루미나의 차폐 성능은 석고보드보다 차폐 성능이 떨어졌으며 50%의 알루미나가 함유되었을 때 석고보드와 차폐 성능이 비슷하였다. 산화철은 약 75%가 함유되었을 때 납복의 차폐 성능과 비슷해졌다. 알루미나를 이용한 차폐체는 석고와 비슷한 차폐 성능을 보여줘 납 대체물질로 적합하지는 않다. 하지만 산화철은 납복과 비슷한 차폐 성능을 나타내어 향후 납을 대체하는 X선 차폐 물질로 활용이 가능하기에 추가 연구가 필요하다.

이동형 방사선 차폐장치의 성능평가에 관한 연구 (A Study on the Performance Evaluation of Portable Radiation Shielding Apparatus)

  • 구본열;한상현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권4호
    • /
    • pp.289-295
    • /
    • 2018
  • When using a mobile X-ray unit, primary radiation creates medical images and secondary radiation scatters in many directions, which reduces image quality and causes exposure to patients, care givers and medical personnel. The purpose of this study was to develop a radiation shielding system for effectively shielding secondary radiation and evaluate its effectiveness. Using a mobile X-ray unit, spatial dose according to presence of human equivalent phantom and spatial dose using the developed shielding device were measured, and the phantom at 80 cm equidistance from center of X-ray was compared with spatial dose according to use of a shield. Measurements were taken at intervals of 10 cm every $30^{\circ}$ from the head direction($-90^{\circ}$) to the body direction($+90^{\circ}$). In the spatial dose measurement with and without the phantom, when the human equivalent Phantom was used, the spatial dose was increased by 40% in all directions from 40 cm to 100 cm from the central X-ray, and about 88% of the space dose was reduced when using the developed shields with the phantom. The equidistance dose at 80 cm from the central X-ray was increased by 39% from $5.1{\pm}0.26{\mu}Gy$ to $7.1{\pm}0.15{\mu}Gy$ when the human equivalent phantom was used, and when phantom was used and shielding was used, the spatial dose was reduced by about 90% from $7.1{\pm}0.15{\mu}Gy$ to $0.7{\pm}0.07{\mu}Gy$. The spatial dose of natural radiation was measured to be about $0.2{\pm}0.04{\mu}Gy$ when using the developed shielding with Phantom at a distance of 1 m or more. It is expected that by using the developed shielding system, it will be possible to effectively reduce secondary radiation dose received in all directions and to ensure safe imaging.

앉은 자세 상지 X-ray 검사(Sitting Position Upper Extremity X-ray Examinations)에서 피폭선량 저감화 연구 (A Study on the Gonads Exposure Dose of Upper Extremity Examinations in Sitting Position)

  • 조평곤
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제34권3호
    • /
    • pp.189-193
    • /
    • 2011
  • 상지 검사(upper extremity X-ray examinations, UEX) 시 환자 위치 잡이로 가장 많이 활용되고 있는 앉은 자세 상지 X-ray 검사(sitting position upper extremity X-ray examinations, SUEX) 시 방사선에 민감한 생식샘과 목적장기 이외 부위에 대한 피폭이 크다고 판단되어 의료기관 별 SUEX 시 납 앞치마(Apron) 착용 유무와 생식샘 및 목적장기 이외 부위에 대한 방사선 피폭과 피폭선량 감소 방안에 대한 연구 결과 거리가 멀어 질수록, 조사야 조절장치를 가능한 목적장기 부위로 제한 조절할수록, 피사체의 두께가 얇을수록 방사선에 의한 피폭은 감소하였고, 생식샘 차폐 유무에 따른 피폭은 생식샘을 차폐했을 때 약 10~50%의 저감화효과를 얻을 수 있었다. 또한 검사 시 apron 착용 유무에 대한 조사에서는 대부분의 경우 apron을 착용하지 않은 것으로 조사되어 시급히 시정되어야 될 것으로 생각된다.