• 제목/요약/키워드: X-ray radiography

검색결과 519건 처리시간 0.032초

An Intraoral Miniature X-ray Tube Based on Carbon Nanotubes for Dental Radiography

  • Kim, Hyun Jin;Kim, Hyun Nam;Raza, Hamid Saeed;Park, Han Beom;Cho, Sung Oh
    • Nuclear Engineering and Technology
    • /
    • 제48권3호
    • /
    • pp.799-804
    • /
    • 2016
  • A miniature X-ray tube based on a carbon-nanotube electron emitter has been employed for the application to a dental radiography. The miniature X-ray tube has an outer diameter of 7 mm and a length of 47 mm. The miniature X-ray tube is operated in a negative high-voltage mode in which the X-ray target is electrically grounded. In addition, X-rays are generated only to the teeth directions using a collimator while X-rays generated to other directions are shielded. Hence, the X-ray tube can be safely inserted into a human mouth. Using the intra-oral X-ray tube, a dental radiography is demonstrated where the positions of an X-ray source and a sensor are reversed compared with a conventional dental radiography system. X-ray images of five neighboring teeth are obtained and, furthermore, both left and right molar images are achieved by a single X-ray shot of the miniature X-ray tube.

이동형 구내방사선촬영기와 벽걸이 구내방사선촬영기로 촬영한 치근단 방사선촬영에서 환자의 흡수선량과 유효선량 평가 (Absorbed and effective dose for periapical radiography using portable and wall type dental X-ray machines)

  • 한원정
    • 대한치과보철학회지
    • /
    • 제50권3호
    • /
    • pp.184-190
    • /
    • 2012
  • 연구 목적: 이 연구는 상악 전치부와 하악 구치부 치근단 방사선촬영시 이동형 구내방사선촬영기와 벽걸이 구내방사선촬영기로 촬영한 경우에서 환자의 방사선량을 알아보고자 하였다. 연구 재료 및 방법: 방사선량 측정은 선량 측정용 두경부 마네킨의 23부위에 열형광선량계 소자를 위치시키고 해당 치근단 방사선촬영을 하였다. 열형광선량계 판독기로 흡수선량을 구하였고 방사선 조사된 조직의 비율을 곱하여 방사선 가중선량을 구하였다. 국제방사선방호위원회에서 2007년에 공지한 조직 가중계수를 이용하여 각 방사선촬영의 유효선량을 구하였다. 결과: 환자의 흡수선량은 이동형 구내방사선촬영기로 촬영한 상악 전치부와 이동형 및 벽걸이 구내방사선촬영기로 촬영한 하악 구치부 치근단방사선촬영의 경우 하악체에서 가장 높았다. 유효선량은 상악 전치부 치근단 방사선촬영에서는 이동형 촬영기로 촬영한 경우 $4{\mu}Sv$, 벽걸이 촬영기로 촬영한 경우 $2{\mu}Sv$였고 우측 하악 구치부 치근단 방사선촬영에서는 각각 $6{\mu}Sv$, $2{\mu}Sv$였다. 결론: 벽걸이 구내방사선촬영기보다 이동형 구내방사선촬영기로 촬영한 치근단 방사선촬영에서의 유효선량이 더 많기 때문에 술자는 구내방사선촬영기에 따른 방사선 노출 정도를 충분히 인지하고 이를 사용하여야 한다.

ORIGINAL ARTICLE - 이동형 구내방사선촬영기로 촬영한 치근단 방사선촬영과 파노라마방사선촬영의 흡수선량과 유효선량 평가 (A absorbed and effective dose from the full-mouth periapical radiography using portable dental x-ray machine and panoramic radiography)

  • 한원정
    • 대한치과의사협회지
    • /
    • 제50권7호
    • /
    • pp.420-430
    • /
    • 2012
  • Purpose: The purpose of this study was to measure the absorbed dose and to calculate the effective dose for full-mouth periapical radiography using the portable dental x-ray machine and panoramic radiography Material and Method: Thermoluminescent chips were placed at 25sites throughout the layers of the head and neck of a tissue-equivalent human skull phantom. The man phantom was exposed with the portable dental x-ray machine and panoramic unit. During full-mouth periapical radiography the exposure setting was 60 kVp, 2 mA and 0.15 ~ 0.25 seconds, while during panoramic radiography the selected exposure setting was 72 kVp, 8 mA and 18 seconds. Absorbed dose measurements were obtained and equivalent doses to individual organs were summed using ICRP 103 to calculate of effective dose. Result: In the full-mouth periapical radiography, the highest absorbed dose was recorded at the mandible body follow with submandibular glands and cheek. Using panoramic unit, the highest absorbed dose was parotid glands and the following was back of neck and submandibular glands. The effective dose in full-mouth periapical radiography using portable dental x-ray machine was 46 ${\mu}Sv$. In panoramic radiography, the effective dose was 38 ${\mu}pSv$. Conclusion: It was recommended to panoramic radiography for general check in the head and neck area because that the effect dose in the panoramic radiography was lower than the dose in the full-mouth periapical radiography using portable dental x-ray machine.

X선 촬영실 내 공간선량의 분포와 거리 역자승 법칙과의 관련성 (Relationship between the Distribution of Space doses in X-ray Rooms and the "Inverse Square Law of Distance")

  • 최성관
    • 한국콘텐츠학회논문지
    • /
    • 제13권8호
    • /
    • pp.301-307
    • /
    • 2013
  • 본 연구는 손, 머리, 복부 등의 X선 촬영 시에 발생되는 공간선량이 어느 정도인지를 알아보고, 산란선에 의한 공간선량의 강도가 "거리 역자승 법칙"에 의해 감쇠하는지를 파악했다. 첫째, 손처럼 X선 산란선 발생량이 적은 촬영의 공간선량은 대부분 "거리 역자승 법칙"에 근접한 감쇠가 이루어지면서, 2m 거리에서는 전혀 측정되지 않았다. 둘째, 머리나 복부처럼 X선 산란선 발생량이 많은 촬영의 공간선량은 조사야 중심을 기준으로 30cm에서 1m 거리까지는 "거리 역자승 법칙"보다 더 높은 비율의 감쇠가 이루어지고, 1m에서 2m 거리까지는 "거리 역자승 법칙"에 의한 감쇠가 이루어졌다. 따라서 X선 촬영실 내에서는 손 촬영의 경우 조사야 중심으로부터 적어도 2m 이상 떨어져 있어야 하고, 머리나 복부 촬영의 경우 촬영실 내 모든 공간에서 보호용구를 이용한 X선 피폭 방어조치가 요구된다.

Effect of the amount of battery charge on tube voltage in different hand-held dental x-ray systems

  • Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • 제42권1호
    • /
    • pp.1-4
    • /
    • 2012
  • Purpose : Hand-held dental x-ray system is a self contained x-ray machine designed to perform intraoral radiography with one or two hands. The issue about its usage as general dental radiography is still in dispute. The aim of the present study was to assess the relationship between the amount of battery charge and the tube voltage in different handheld dental x-ray systems. Materials and Methods : Seven hand-held dental x-ray units were used for the study. Tube voltage was measured with Unfors ThinX RAD (Unfors Instruments AB, Billdal, Sweden) for 3 consecutive exposures at the different amount of battery charge of each unit. The average and the deviation percentage of measured kV from indicated kV of each unit were calculated. Results : Tube voltage of only 1 unit was 70 kV (indicated by manufacturer) and those of the others were 60 kV. Tube voltage deviation percentage from the indicated kV at the fully charged battery was from 2.5% to -5.5% and from -0.8% to -10.0% at the lowest charged battery. Conclusion : Tube voltages of all units decreased as the residual amount of the battery charge decreased. It is suggested that the performance test for hand-held x-ray system should be performed for the minimum residual charged battery as well as the full charged one. Persistent battery charging is suggested to maintain the proper tube voltage of the hand-held portable x-ray system.

이동용 치과 X선 발생장치의 누설 및 산란 선량에 관한 연구 (Leakage and scattered radiation from hand-held dental x-ray unit)

  • 김은경
    • Imaging Science in Dentistry
    • /
    • 제37권2호
    • /
    • pp.65-68
    • /
    • 2007
  • Purpose: To compare the leakage and scattered radiation from hand-held dental X-ray unit with radiation from fixed dental X-ray unit. Materials and Methods: For evaluation we used one hand-held dental X-ray unit and Oramatic 558 (Trophy Radiologie, France), a fixed dental X-ray unit. Doses were measured with Unfors Multi-O-Meter 512L at the right and left hand levels of X-ray tube head part for the scattered and leakage radiation when human skull DXTTR III was exposed to both dental X-ray units. And for the leakage radiation only, doses were measured at the immediately right, left, superior and posterior side of the tube head part when air was exposed. Exposure parameters of handheld dental X-ray unit were 70 kVp, 3 mA, 0.1 second, and of fixed X-ray unit 70 kVp, 8 mA, 0.45 second. Results: The mean dose at the hand level when human skull DXTTR III was exposed with portable X-ray unit $6.39{\mu}Gy$, and the mean dose with fixed X-ray unit $3.03{\mu}Gy$ (p<0.001). The mean dose at the immediate side of the tube head part when air was exposed with portable X-ray unit was $2.97{\mu}Gy$ and with fixed X-ray unit the mean dose was $0.68{\mu}Gy$ (p<0.01). Conclusions: The leakage and scattered radiation from hand-held dental radiography was greater than from fixed dental radiography.

  • PDF

16kW 회전 Aonde형 모노블럭 X-선 발생장치 (A 16kw Rotating Anode type Monoblock X-ray Generator)

  • 오준용;김연충;김학성
    • 전력전자학회논문지
    • /
    • 제11권2호
    • /
    • pp.97-103
    • /
    • 2006
  • 본 논문은 회전형 대용량 진단 X-선 발생장치를 모노 블록 형태로 설계, 병원의 모바일 진단장치나, 산업용 X-선 장치로에 적용이 가능한 16kW급 회전 Anode형 모노블럭 X-선 발생장치에 관한 연구이다. 본 장치는 X-선 발생을 위해 회전 Anode 형의 X-선관을 사용하였고, X-선관의 Anode의 회전을 위한 로터를 구동할 수 있는 로터 구동회로를 추가 하였다. 고주파 고전압용 인버터에는 IGBT(600V/300A)소자를 100kHz로 고주파 스위칭 함으로서 고전압 변압기를 비롯한 고전압 발생부의 크기와 무게를 최소화하였다. 또한, 기존의 16kW급 대용량 진단 X-선 발생장치를 X-선관과 고전압부를 일체화한 모노블록 형태로 설계, 제작하여 부하변동에 따른 X-선 관전압과 관전류의 동작특성을 실험을 통하여 입증하였다.

디지털 방사선영상 시스템의 기본적 원리 (Physical principles of digital radiographic imaging system)

  • 최진우;이원진
    • Imaging Science in Dentistry
    • /
    • 제40권4호
    • /
    • pp.155-158
    • /
    • 2010
  • Digital radiographic systems allow the implementation of a fully digital picture archiving and communication system (PACS), and provide the greater dynamic range of digital detectors with possible reduction of X-ray exposure to the patient. This article reviewed the basic physical principles of digital radiographic imaging system in dental clinics generally. Digital radiography can be divided into computed radiography (CR) and direct radiography (DR). CR systems acquire digital images using phosphor storage plates (PSP) with a separate image readout process. On the other hand, DR systems convert X-rays into electrical charges by means of a direct readout process. DR systems can be further divided into direct and indirect conversion systems depending on the type of X-ray conversion. While a direct conversion requires a photoconductor that converts X-ray photons into electrical charges directly, in an indirect conversion, lightsensitive sensors such as CCD or a flat-panel detector convert visible light, proportional to the incident X-ray energy by a scintillator, into electrical charges. Indirect conversion sensors using CCD or CMOS without lens-coupling are used in intraoral radiography. CR system using PSP is mainly used in extraoral radiographic system and a linear array CCD or CR sensors, in panoramic system. Currently, the digital radiographic system is an important subject in the dental field. Most studies reported that no significant difference in diagnostic performance was found between the digital and conventional systems. To accept advances in technology and utilize benefits provided by the systems, the continuous feedback between doctors and manufacturers is essential.

X-ray Response Characteristic of Zn in the Polycrystalline Cd1-xZnxTe Detector for Digital Radiography

  • Kang, Sang-Sik
    • Transactions on Electrical and Electronic Materials
    • /
    • 제3권2호
    • /
    • pp.28-31
    • /
    • 2002
  • The Cdl-xZnxTe film was fabricated by thermal evaporation for the flat-panel X-ray detector. The stoichimetric ratio and the crystal structure of a polycrystalline Cd$_{1-x}$ Zn$_{x}$Te were investigated by EPMA and XRD, respectively. The leakage current and X-ray sensitivity of the fabricated films were measured to analyze the X-ray response characteristic of Zn in the polycrystalline CdZnTe thin film. The leakage current and the output charge density of Cd$_{0.7}$Zn$_{0.3}$Te thin film were measured to 0.37 nA/cm$^2$ and 260 pc/cm$^2$ at an applied voltage of 2.5 V/${\mu}{\textrm}{m}$, respectively. Experimental results showed that the increase of Zn doping rates in Cd$_{1-x}$ Zn$_{x}$Te detectors reduced the leakage current and improved the signal to noise ratio significantly.

강내형 X선 튜브 온도 및 선량 분포 특성 (The Characteristic of Temperature and Dose Distribution of intra oral X-ray Tube)

  • 조성호;이레나
    • 전자공학회논문지
    • /
    • 제50권5호
    • /
    • pp.262-266
    • /
    • 2013
  • 신개념 치과용 X선 촬영장치인 강내형 X선 튜브에 대한 연구가 소개되었다. 이는 초소형의 X-선 튜브를 구강내 삽입하여 외부에서 검출기로 영상을 획득하는 새로운 시스템이다. 본 연구에서는 구내 치근단 촬영을 위해 사용하는 강내형 X선 튜브의 온도분포 및 선량 분포 특성을 조사하였다. X선 튜브의 온도특성을 파악하기 위하여 튜브 표면에 써머커플을 부착하여 튜브 표면에서부터 거리에 대한 온도를 측정하였으며, EBT 필름을 이용하여 튜브표면에서부터 거리에 따른 선량 분포를 측정하였다. 그 결과 냉각장치가 없는 튜브에서 2mm 이상 거리에서 온도는 $27^{\circ}C$로 일정하였으며, 튜브에서 3cm, 5cm일 때 선량분포가 3.14, 1.84mGy로 나타났다. 그 결과 제안한 시스템은 기존 시스템에 비해 낮은 선량에서 안전하게 촬영이 가능한 것으로 향후 구내 치근단 촬영장치에 새로운 변화를 가져올 수 있을 것으로 사료된다.