• Title/Summary/Keyword: Winding insulation

Search Result 254, Processing Time 0.029 seconds

A Study on the Complex Accelerating Degradation and Condition Diagnosis of Traction Motor for Electric Railway (전기철도용 견인전동기의 복합가속열화 상태진단에 관한 연구)

  • 왕종배
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.1
    • /
    • pp.93-101
    • /
    • 2002
  • In this study, the stator form-winding sample coils based on silicone resin and polyimide were made for fault prediction and reliability estimation on the C-Class(200$\^{C}$ ) insulation system of traction motors. The complex accelerative degradation was periodically performed during 10 cycles, which was composed of thermal stress, fast rising surge voltage, vibration, water immersion and overvoltage applying. After aging of 10 cycles, the condition diagnosis test such as insulation resistance '||'&'||' polarization index, capacitance '||'&'||' dielectric loss and partial discharge properties were investigated in the temperature range of 20 ∼ 160$\^{C}$. Relationship among condition diagnosis tests was analyzed to find a dominative degradation factor and an insulation state at end-life point.

Insulation Properties of Unaged Stator Winding Bars for Turbine Generators (터빈 발전기용 비열화 고정자 권선 바의 절연 특성)

  • Kim, Tae-Hee;Kang, Myung-Guk;Lee, Jai-Kwun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2097-2099
    • /
    • 2005
  • Class-F and class-B insulating materials based on the resin rich type mica-epoxy composites for the stator windings in large turbine generators have been developed by DHIC. In recent, stator winding bars applied with prototype insulation tapes and commercially available resin rich groundwall tapes were produced through the same manufacturing processes as the real bars. Comparative tests to obtain the insulation properties of both bars were carried out such as IR/PI. dissipation factor and partial discharge at room temperature. In this paper, the manufacturing processes and the insulation properties of the bars which were not aged are presented.

  • PDF

A study on insulation characteristics with AC Breakdown Test for Stator Winding of 3.3kV class Induction Motor (절연파괴시험을 통한 3.3kV 유도전동기의 절연특성 연구)

  • Lee, Dong-Geun;Lee, Kwang-Ho;Choi, Kyo-Nam;Kim, Hyun-Il;Kwak, Hee-Jin;Oh, Bong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2118-2122
    • /
    • 2005
  • This test was performed to assess the corelation of insulation deterioration condition with breakdown voltage of the stator winding of 3.3kV class induction motors which have been in service for 10 years after being installed in 1993. The insulation diagnostic tests include resistance, polarization index(P.I), dissipation factor$({\Delta}tan{\delta})$, maximum partial discharges (Qmax) and AC breakdown test. we evaluated the corelation of insulation diagnostic test with AC breakdown test for stator wilding of high voltage induction motor.

  • PDF

A study on charging and electrical stability characteristics with no-insulation and metal insulation in form of racetrack type coils

  • Quach, Huu Luong;Kim, Ho Min
    • Progress in Superconductivity and Cryogenics
    • /
    • v.22 no.3
    • /
    • pp.13-19
    • /
    • 2020
  • This study presents the experiment and simulation results on the magnetic field response and electrical stability behaviors of no-insulation (NI) and metal insulation with stainless steel tape (MI-SS) which wound in form of racetrack type coils. First of all, the structural design of the racetrack type bobbin was shown along with its parameters. Then, the current-voltage tests were carried out to measure the critical current of both test coils. Also, the sudden discharging and charging tests were performed in the steady state to estimate the decay field time and magnetic field response, respectively. Finally, the overcurrent tests were conducted in the transient state to investigate the electrical stability of these test coils. Based on the experimental results, the contact surface resistances were calculated and applied to the field coils (FCs) of 10-MW-class second generation high temperature superconducting generator (2G HTSG) used in wind offshore environment. The charging delay time and electrical stability for NI and MI-SS HTS FCs of 10-MW-class 2G HTSG are analyzed by the equivalent circuit model and the key parameters which were obtained from the electromagnetic finite element analysis results.

Site Evaluation and Application of the On-line and Off-line Test for the 13[kV] Class Hydropower Generator Stator Windings (13[kV]급 수력발전기 고정자 권선의 운전 및 정지 중 진단시험 현장적용 평가 및 분석)

  • Chang, Jeong-Ho;Lee, Dong-Keun;Lee, Heung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.11
    • /
    • pp.73-82
    • /
    • 2011
  • The solid insulation system of stator windings in high voltage rotational machines is usually aging in accordance with long time operation. The partial discharge test have been known to check whether insulation deterioration exist or not, and the PD test can effectively diagnose a solid insulation condition regardless of during operation(on-line) or not(off-line). The on-line PD measurement have proven to be a successful technique in monitoring stator insulation condition nowadays. This paper describes the characteristics of comparing the on-line PD measurement data using PDMS-HG(Partial Discharge Monitoring System for Hydro-electric Generator) installed in field with the off-line diagnosis measurement data(insulation resistance, winding resistance, PI, ${\Delta}tan{\delta}$ and PD) on hydro generator(13[kV]) stator windings. These results make good use of managing rotational machines through evaluating the solid insulation condition of stator windings.

A Study on the Expected Life Evaluation of Rotating Machine (회전 기기의 수명 예측 평가에 관한 연구)

  • Kim, Ki-Joon;Kim, Sang-Jin;Oh, Yong-Chei;Seong, Nak-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.73-76
    • /
    • 2000
  • Traction motors that is one of the rotating machines for urban transit EMU have been subjected to increased demand for higher operating temperature, more demanding duty cycles, higher starting current, frequent voltage transients and severe environmental exposure. With the advent of PWM drives using power IGBTs in addition to the thermal considerations, it is important to take into account the impact of the dielectric stress upon the winding insulation system life. In analyzing the life of the stator winding, which is the heart of the motor, the majority of all winding failures are usually caused by a combination of various stresses acting on the insulation materials and system. In this paper, to evaluate the expected life of traction motor for urban transit E.M.U. it is proposed a new test method of complex accelerating degradation.

  • PDF

Electrical Stress Analysis of High Voltage motor Winding by Switching Surge (스위칭 서지에 의한 고압유도전동기의 권선의 전기적 스트레스 해석)

  • Kim, Jong-Kyeom;Lee, Eun-Woong;Kim, Il-Jung
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.990-992
    • /
    • 1993
  • Studies have been made to establish what coil design parameters have an important influence on the amplitude of interturn voltages developed in a machine winding subject to steep-fronted surges. The studies are based on a lattice-diagram model of multi conductor transmission line in a machine winding energised by a simple ramp function. Variations in interturn voltages produced by changes in insulation thickness, insulation permittivity, surge wave-front are examined and certain guidelines for avoiding high interturn voltages are evaluated.

  • PDF

Applied Technology of FRP Single Pole for Power Distribution Line (배전용 지지물의 FRP 적용 기술)

  • 박기호;조한구;한동희
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.79-81
    • /
    • 2000
  • Outdoor insulation of overhead distribution lines with wood, concrete and steel pole has been safety under various environmental conditions including contamination, moisture condensation, rain and lightning overvoltages. In this paper introduce to FRP technology of the power distribution single pole. FRP pole has been used very much as high strength material for insulators because of its high strength and good insulation properties. In addition, FRP pole was made by filament winding method. In a filament winding process, a band of continuous resin-impregnated rovings or monofilaments is wrapped around a rotating mandrel and cured to produce axisymmetric hollow parts.

  • PDF

Analysis on Partial Discharge Fault Signals of PRPD for High Voltage Motor Stator Winding (고압전동기 고정자 권선의 PRPD 부분방전 결함신호 해석)

  • Park Jae-Jun;Lee Sung-Young;Mun Dae-Chul
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.10
    • /
    • pp.942-946
    • /
    • 2006
  • We simulated insulation defects of stator winding wire on high voltage generator by 5 types. 4 types have one discharge source and other one has multi discharge source by simulation. For accurate decision, measurements used to PRPD pattern to occurred partial discharge source of various types. In this research, when PRPD pattern carried out or analyzed pattern recognition of discharge source, it used to powerful tools. In this result, PRPD Pattern defined to have single discharge source of 4 types by insulation defect. When insulation defect simulated, all the defected winding have not the same result. Errors for a little different can make mistakes from a subtle distinction. The difference between internal and void discharge have magnitude of pulse amplitude of inner discharge bigger than void discharge and have a shape of bisymmetry. But void discharge has a shape of bisymmetry against maximum value on polarity respectively. In cases of slot and surface discharge, we confirmed to show similar results those other researchers. In case of multi-discharge, as a result of we could classify not perfect match with occurred patterns in single discharge eachother. In the future, we will have to recognize and classify with results of multi-discharge.

A Case Study of On-line PD Measuring System on the Stator Winding for High Voltage Rotating Machine (고전압회전기 고정자권선 운전중 부분방전진단시스템의 현장적용사례 연구)

  • Oh, Bong-Keun;Kang, Dong-Sik;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.109-109
    • /
    • 2010
  • On-line partial discharge(PD) diagnostic system is the most prominent systems to diagnose insulation condition for the high voltage rotating machines. Partial discharge measuring system(PDMS) series with ceramic coupler(PD detecting sensor) installed hydro generator and high voltage motor have been measured the PD data for many years. The trend of PD magnitude in the on-line PD system increased for some machines. These machines showed a same result in the conventional off-line PD test and PD magnitude decreased after stator winding insulation cleaning. This case study show that PDMS has been proved to be good results by comparing PD magnitude with on-line and off-line PD test and it is important to plan the maintenance project for the hydro generator stator winding because PD value was decreased after insulation cleaning.

  • PDF