• Title/Summary/Keyword: Viscous model

Search Result 672, Processing Time 0.026 seconds

An Approximation Expression of Wave Velocity of Viscous Boundary for Infinitely tong Elevated Bridge (반무한 연속고가교에 대한 점성경계 설정속도의 간편식)

  • Lee, Sang-Hun;Endo, Takao;Lee, Weon-Cheol
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.140-143
    • /
    • 2007
  • A continuing elevated bridge is replaced with mass-spring system model, and a part of the bridge is cut out as an analytical area. A viscous boundary is installed at both ends, and dynamic analyses are carried out changing the wave velocity of the viscous boundary, The result is compared with a result of a very long model corresponding to the solution with infinite length. A wave velocity is chosen so that the good performance of a viscous boundary is exhibited. The parametric analyses are carried out changing the model of various structural properties, and an approximation expression is suggested to obtain the wave velocity easily for setting a viscous boundary.

  • PDF

Dynamic Analysis of the Small Reciprocating Compressors Considering Viscous Frictional Force of a Piston (피스톤의 점성 마찰력을 고려한 소형 왕복동 압축기의 동적 해석)

  • 김태종
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.11
    • /
    • pp.904-913
    • /
    • 2002
  • In this study, a dynamic analysis of the reciprocating compression mechanism considering viscous friction force of a piston used in small refrigeration compressors is performed. The length of cylinder in this class of compressors is shortening to diminish the frictional losses of the piston-cylinder system. So, the contacting length between piston and cylinder liner is in variable with the rotating crank angle around the BDC of the reciprocating piston. In the problem formulation of the compression mechanism dynamics, the change in bearing length of the piston and all corresponding viscous forces and moments are considered in order to determine the trajectories of piston and crankshaft. The piston orbits for viscous friction model and Coulomb friction model were used to compare the effect of the friction forces of piston on the dynamic trajectories of piston. To investigate the effect of friction force acting on the piston for the dynamic characteristics of crankshaft, comparison of the crankshaft loci is given in both viscous model and Coulomb model. Results show that the viscous friction force of piston must be considered in calculating for the accurate dynamic characteristics of the reciprocating compression mechanism.

Wind tunnel experiments of a building model incorporating viscous-damping walls

  • Pan, Austin D.E.;Yeung, Ngai
    • Wind and Structures
    • /
    • v.4 no.3
    • /
    • pp.261-276
    • /
    • 2001
  • This paper presents an experimental study on the effectiveness of viscous-damping walls in controlling the wind-induced vibrations of a building model. A simple four-story building model, square in plan, was constructed for wind tunnel study. In this paper the description of the model, its instrumentation, and the experimental set-up and methodology are reported. The effectiveness of viscous-damping walls in reducing vibrations was investigated for different fluid levels in the walls, and at varying wind speeds and attack angles. The results show that viscous-damping walls are highly effective in most cases.

Prediction of Creep Behavior for Cohesive Soils (점성토에 있어서의 크리프 거동 예측)

  • Kim Dae-Kyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.7
    • /
    • pp.79-89
    • /
    • 2004
  • An elastic-plastic-viscous constitutive model was proposed based on a simple formulation scheme. The anisotropic modified Cam-Clay model was extended for the general stress space for the plastic simulation. The generalized viscous theory was simplified and used for the viscous constitutive part. A damage law was incoporated into the proposed constitutive model. The mathematical formulation and development of the model were performed from the point of view that fewer parameters be better employed. The creep behaviors with or without creep rupture were predicted using the developed model for cohesive soils. The model predictions were favorably compared with the experimental results including the undrained creep rupture, which is an important observed phenomenon for cohesive soils. Despite the simplicity of the constitutive model, it performs well as long as the time to failure ratio of the creep rupture tests is within the same order of magnitude.

STABILITY ANALYSIS OF REGULARIZED VISCOUS VORTEX SHEETS

  • Sohn, Sung-Ik
    • Bulletin of the Korean Mathematical Society
    • /
    • v.53 no.3
    • /
    • pp.843-852
    • /
    • 2016
  • A vortex sheet is susceptible to the Kelvin-Helmhotz instability, which leads to a singularity at finite time. The vortex blob model provided a regularization for the motion of vortex sheets in an inviscid fluid. In this paper, we consider the blob model for viscous vortex sheets and present a linear stability analysis for regularized sheets. We show that the diffusing viscous vortex sheet is unstable to small perturbations, regardless of the regularization, but the viscous sheet in the sharp limit becomes stable, when the regularization is applied. Both the regularization parameter and viscosity damp the growth rate of the sharp viscous vortex sheet for large wavenumbers, but the regularization parameter gives more significant effects than viscosity.

Seismic analysis of 3-D two adjacent buildings connected by viscous dampers with effect of underneath different soil kinds

  • Farghaly, Ahmed Abdelraheem
    • Smart Structures and Systems
    • /
    • v.15 no.5
    • /
    • pp.1293-1309
    • /
    • 2015
  • 3D two adjacent buildings with different heights founded in different kinds of soil connected with viscous dampers groups, with especial arrangement in plane, were investigated. Soil structure interaction for three different kinds of soil (stiff, medium and soft) were modeled as 3D Winkler model to give the realistic behavior of adjacent buildings connected with viscous dampers under various earthquake excitations taking in the account the effect of different kinds of soil beneath the buildings, using SAP2000n to model the whole system. A range of soil properties and soil damping characteristics are chosen which gives broad picture of connected structures system behavior resulted from the influence soil-structure interaction. Its conclusion that the response of connected structures system founded on soft soil are more critical than those founded on stiff soil. The behavior of connected structures is different from those with fixed base bigger by nearly 20%, and the efficiency of viscous dampers connecting the two adjacent buildings is reduced by nearly 25% less than those founded on stiff soil.

Dynamic Analysis of Sand-Clay Layered Ground Considering Viscous Effect of Clay

  • Kim, Yong-Seong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.48 no.7
    • /
    • pp.45-52
    • /
    • 2006
  • A cyclic viscoelastic-viscoplastic constitutive model for clay is incorporated into an effective stress based seismic response analysis to describe viscous effect of clay layer to sand layer during earthquake. The seismic response against main shock of 1995 Hyogoken Nambu Earthquake is analyzed in the present study. Acceleration responses in both clay layer and just upper liquefiable sand layer are damped due to viscous effect of clay. A cyclic viscoelastic-viscoplastic constitutive model for clay was implemented into a FEM code, and $Newmark{\beta}$ method was employed for the time discretization in the finite element formulation. Seismic responses were simulated by numerical method with recorded data at Port Island, Kobe, Japan. As results of this study, it was found that a cyclic viscoelastic-viscoplastic constitutive model can give good description of dynamic behavior characteristics including viscoelastic effect.

Mechanical Characteristic Analysis of Coil Spring & Viscous Damper (Coil Spring & Viscous Damper System의 동특성분석)

  • Kim, Min-Kyu;Choun, Young-Sun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.2 s.54
    • /
    • pp.19-26
    • /
    • 2007
  • This paper presents the results of experimental studies of the mechanical characteristics of the Coil Spring and Viscous Damper system. The Coil Spring and Viscous Damper systems were selected for the isolation of Emergency Diesel Generator (EDG) which is located in Nuclear Power Plant (NPP). The Coil Spring and Viscous Damper systems were developed for the operating vibration isolation and seismic isolation for scaled Model EDG System. The damping properties of the viscous damper changes as the variation of velocity. Through this research nonlinear damping characteristics and the effective stiffness of coil spring and viscous damper system were evaluated.

Analysis of Forced Convection Heat Transfer for Axial Annular Flow of Giesekus Viscoelastic Fluid

  • Mohseni, Mehdi Moayed;Rashidi, Fariborz;Movagar, Mohammad Reza Khorsand
    • Korean Chemical Engineering Research
    • /
    • v.53 no.1
    • /
    • pp.91-102
    • /
    • 2015
  • Analytical solutions for the forced convection heat transfer of viscoelastic fluids obeying the Giesekus model are obtained in a concentric annulus under laminar flow for both thermal and hydrodynamic fully developed conditions. Boundary conditions are assumed to be (a) constant fluxes at the walls and (b) constant temperature at the walls. Temperature profiles and Nusselt numbers are derived from dimensionless energy equation. Subsequently, effects of elasticity, mobility parameter and viscous dissipation are discussed. Results show that by increasing elasticity, Nusselt number increases. However, this trend is reversed for constant wall temperature when viscous dissipation is weak. By increasing viscous dissipation, the Nusselt number decreases for the constant flux and increases for the constant wall temperature. For the wall cooling case, when the viscous dissipation exceeds a critical value, the generated heat overcomes the heat which is removed at the walls, and fluid heats up longitudinally.

The Study of Dynamic Characteristic of a Viscous Fluid Damper in Vibration Isolation (진동 방지용 점성 유체 댐퍼의 동특성 해석에 관한 연구)

  • 권오병;이강민;김유민;고철수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.1136-1140
    • /
    • 2001
  • Viscous fluid damper is used for vibration isolation of piping system, presses, turbo-generator and other heavy industrial equipments, as well as seismic isolation of buildings structure. So dynamic characteristic of viscous fluid damper is very important. This paper presents the result of the study of dynamic characteristic of viscous fluid damper. And the force-displacement relation of the viscous damper is described by experimentally calibrated fractional derivative Maxwell Model. The proposed model is validated by dynamic testing and A good agreement between predicted and experimental results is obtained.

  • PDF