Abstract
This paper presents the results of experimental studies of the mechanical characteristics of the Coil Spring and Viscous Damper system. The Coil Spring and Viscous Damper systems were selected for the isolation of Emergency Diesel Generator (EDG) which is located in Nuclear Power Plant (NPP). The Coil Spring and Viscous Damper systems were developed for the operating vibration isolation and seismic isolation for scaled Model EDG System. The damping properties of the viscous damper changes as the variation of velocity. Through this research nonlinear damping characteristics and the effective stiffness of coil spring and viscous damper system were evaluated.
Keywords
Coil Spring and Viscous Damper system; Emergency Diesel Generator (EDG); Nuclear Power Plant (NPP); velocity dependent damping property;
Citations & Related Records
연도 인용수 순위
  • Reference
1 김민규, 전영선, 권형오, '기초형식에 따른 비상디젤발전기의 진동저감효과 분석',2005년도 대한토목학회 정기 학술대회, 제주, 2005
2 Huffmann, G.K. 'Protection of Spring Supported Equipment Against Seismic Excitation,' PVP-Vol. 222, Seismic, Shock and Vibration Isolation, ASME, 1991, pp. 45-50
3 Macinate, J.A., Seismic Mountings for Vibration Isolation, John Wiley & Sons, 1984
4 Makris, N. and Constantinou, M.C. 'Spring-Viscous Damper Systems for Combined Seismic and Vibration Isolation,' Earthquake engineering and Structural Dynamics, Vol. 21, 1992, pp. 649-664   DOI
5 Makris, N. and Deoskar, H. 'Prediction of Observed Response of Base-Isolated Structure,' Journal of Structural Engineering, Vol. 122, No.5, 1996, pp. 485-493   DOI
6 Makris, N. Constantinou, M.C. and Huffmann, G.K. 'Testing and Modeling of Viscous Dampers,' PVP-Vol. 222, Seismic, Shock, and Vibration Isolation, ASME, 1991, pp. 51-56
7 Huffmann, G.K. 'Full Base Isolation for Earthquake Protection by Hellical Spring and Viscodarnper,' Nuclear Engineering and Design, Vol. 84, 1985, pp. 331-338   DOI   ScienceOn
8 GERB Schwingungsisolierungen GmbH & Co KG, Vibration Isolation Systems. Essen, Germany, 2000
9 전영선, 최인길, '원전기기의 지진력 저감이 노심손상빈도에 미치는 영향 평가', 한국원자력학회 추계학술발표회, 2002