• Title/Summary/Keyword: Vertical rail

Search Result 198, Processing Time 0.031 seconds

Classification of Rail System in Steel Structure Stadiums by Case Study (사례분석에 의한 강구조 스타디움 레일 시스템 분류)

  • Kim, Hye-Seong;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.1
    • /
    • pp.67-74
    • /
    • 2010
  • This paper focuses on steel arrays regarding the application of PV system for solar power system, a renewable energy in steel structure stadium that will be built in Korea, by foreign case study. 20 cases of Steel Structure Stadiums applying PV system after 1990 were selected as the main subjects. The 20 cases of Steel Structure Stadiums were categorized by rail systems that were installed to fix PV module. As the result, linear clamping and roof-integrated type among cross rails were 28% of the whole, followed by 17% of rail-fixed type and 11% of module group-fixed type among vertical-fixed types. In addition, linear clamping and roof-integrated type among cross rails were applied in the inside of the stadium while the outside and other parts of stadiums used angle bracket to fix PV module.

  • PDF

Analysis of Occurrence Tendency of Rail Force According to Running the Hanvit 200 Train on Transition Curve Track (한국형 틸팅차량 완화곡선 주행시 궤도작용력 발생경향 분석)

  • Park, Yong-Gul;Choi, Sung-Yong;Kim, Youn-Tae;Choi, Jung-Youl
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.5
    • /
    • pp.678-686
    • /
    • 2009
  • A trial run of locally-developed tilting train has been in process on Chungbuk line since the test vehicle was first produced. For the system stabilization, interface verification among the systems including track, structure, catenary and signaling system, not to mention the rolling stock, is very crucial. Therefore, in this study, the dynamic rail force of the tilting (Hanvit 200), high-speed (KTX) and general (Mugunghwa) vehicle caused by driving in transition curve track was measured. And, it compared the tilting response with the other by using the measured rail force data in transition curve track, and then evaluated probability the range of load fluctuation for the variable dynamic vertical and lateral wheel load. As a result, a range of rail force by occurred a change of cant from the high-speed and general vehicle which had fixed bogie structure was distributed throughout small deviation. Otherwise, in case of the tilting train which was consisted of the pendulum bogie structure was distributed wide range about large deviation by changed of cant.

Structural Analysis of the Gait Rehabilitation System of a Rail Type for Body-Weight Support Function (체중지지를 위한 레일형 보행 재활 시스템 구조 해석)

  • Kim, Jae Jun;Kim, Kyung;Seo, Young Soo;Kim, Jae Won;Kim, Je Nam;Chong, Wu Suk;Yu, Chang Ho;Kwon, Tae Kyu;Song, Won Kyung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.9
    • /
    • pp.761-768
    • /
    • 2016
  • Weight bearing is effective during rehabilitation of gait, in the elderly and disabled people. Various training devices using weight bearing function were developed along with treadmill walking; however, no device has been developed in conjunction to walking on the ground. Here, we designed a rail type frame of a gait rehabilitation system for body-weight support (BWS) function, and analyzed its mechanical safety in the static weight bearing condition of a vertical axis. Computational simulations were performed to analyze structure of the driving parts, which are connected with a rail and driving rollers and the lower plate of the BWS. Structural analyses showed the drivers and BWS were safe, when simulated at 135kg weight under static conditions. Thus, this rail type rehabilitation system can be used for gait training of the elderly and disabled.

A Study on the Economic and the Field Application Feasibility of Unit Curtain Wall Mullion Rail Lift System (유니트 커튼월 멀리온 레일 양중 시스템의 경제성 및 현장 적용 가능성에 관한 연구)

  • Jung, Ui-In;Kim, Hea-Na;Kim, Bong-Joo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.1
    • /
    • pp.41-49
    • /
    • 2021
  • This study was to solve the lift problem of the existing unit curtain wall type by using the vertical material mullion as a rail in curtain wall, which is recently used as an external finishing material for high-rise buildings. It has been shown that the application of the curtain wall mullion's rail can be quantified even at 20m/sec wind speed through the Mock-Up test. Based on the sites selected for comparison of construction methods, it was analyzed that the construction period could be shortened by 48 days, or about 20 percent. It was analyzed that the number of construction workers could be reduced by about 33 percent from the previous nine to six. Based on these results, assuming the installation of curtain wall units of 10,000㎡, it is judged that construction cost can be reduced by 80% or more.

The drained deformation characteristics of sand subjected to lateral cyclic loading

  • Junhua Xiao;Jiapei Ma;Jianfeng Xue;Zhiyong Liu;Yingqi Bai
    • Geomechanics and Engineering
    • /
    • v.34 no.5
    • /
    • pp.481-489
    • /
    • 2023
  • Drained cyclic triaxial tests were conducted on a saturated sand to examine its deformation characteristics under either axial or lateral cyclic loading condition. To apply lateral cyclic loading, the cell pressure was cycled while maintaining a constant vertical stress. The strain accumulations and flow direction in the soil were presented and discussed considering various initial stress ratios (η0), cyclic stress amplitudes and cyclic stress paths. The results indicate that axial strain accumulation shows an exponential increase with the maximum stress ratio (ηmax). The initial deviatoric stress has comparable effects with lateral cyclic stress amplitude on the accumulated axial strain. In contrast, the accumulated volumetric strain is directly proportional to the lateral cyclic stress amplitude but not much affected by η0 values. Due to the anisotropy of the soil, the accumulated axial and lateral bulging strains are greater in lateral cyclic loading when compared to axial cyclic loading even though ηmax is the same. It is also found that ηmax affects soil's lateral deformation and increasing the ratio could change the lateral deformation from contraction to bulging. The flow direction depends on ηmax in the sand under lateral cyclic loading, regardless of η0 values and the cyclic stress amplitudes, and a large ηmax could lead to great deviatoric strain but a little volumetric strain accumulation.

A Study on the contact force calculation by bending load of axle of rolling stocks (철도차량 차축의 굽힘하중에 의한 차륜/레일 접촉력 계산에 관한 연구)

  • Ham, Young-Sam
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.481-484
    • /
    • 2008
  • The important factor to evaluate the running safety of a railway vehicle would be the interaction force between wheel and rail(derailment coefficient), for which is one of important factors to check the running safety of a railway vehicle that may cause a tragic accident. Element that analyze derailment coefficient is consisted of wheel load and lateral force. In this paper, studied about method that calculate vertical force(wheel load) by bending load of axle in rolling stocks.

  • PDF

Fundamental Study of the Building Exterior Wall Cleaning Robot using Vertical rails (수직레일을 이용한 건물 외벽청소로봇 개발방향 연구)

  • Park, Su-Yeul;Kim, Kyoon-Tai;Han, Jae-Goo;Kim, Chang-Han
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.185-187
    • /
    • 2012
  • Recently increasing high-rise building cleaning on the exterior walls of high-rise buildings, there has been increased interest. Building exterior cleaning is cleaned by a cleaning robot and how to clean the exterior walls of the building and exterior glass cleaned by personnel. Number of stories in the building increases, being carried out by personnel cleaning the outer wall as there is a limit order to overcome this method. therefor, this study is a new exterior wall cleaning device has been proposed.

  • PDF

Parametric Study on Thermal Buckling of CWR Tracks (장대레일궤도의 온도좌굴에 영향을 미치는 매개변수 연구)

  • 최동호;김호배
    • Proceedings of the KSR Conference
    • /
    • 2001.05a
    • /
    • pp.295-302
    • /
    • 2001
  • The lateral stability of curved continuous welded rail (CWR) is studied fur buckling prevention. This study includes the influences of vehicle induced loads on the thermal buckling behavior of straight and curved CWR tracks. quasi-static loads model is assumed to determine the uplift region, which occurs due to the vertical track deformation induced by wheel loads of vehicle. Parametric numerical analyses are performed to calculate the upper and lower critical buckling temperatures of CWR tracks. The parameters include track lateral resistance, track curvature, longitudinal stiffness, tie-ballast friction coefficient, axle load, truck center spacing, and the ratio of lateral to vertical vehicle load. This study provides a guideline for the improvement or stability for dynamic buckling in on tracks.

  • PDF

Optimization of vertical SOI slot optical waveguide with confinement factor and sensitivity for integrated-optical biochemical sensors (구속계수와 감지도에 기반한 집적광학 바이오케미컬 센서에 적합한 수직 SOI 슬롯 광 도파로 최적화)

  • Jung, Hongsik
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.3
    • /
    • pp.131-138
    • /
    • 2021
  • The optimization of the specifications of vertical silicon on insulator (SOI) slot optical waveguides suitable for integrated-optical biochemical sensors was performed through computational analysis of the confinement factor of the guided mode distributed in the slot in addition to analytical examination of the TE mode. The optimized specifications were confirmed based on sensitivity in terms of the change in the refractive index of the biochemical analyte. When the slot width, rail width, and height were set to 120 nm, 200 nm, and 320 nm, respectively, the confinement factor was evaluated to be about 56% and the sensitivity was at least 0.9 [RIU/nm].

Evaluation on the Condition of Track Substructure Using GPR/PBS/LEWD (GPR/PBS/LFWD를 이용한 궤도하부 상태평가)

  • Kim Dae-Sang;Hwang Seon-Keun;Shin Min-Ho;Park Tae-Soon
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.5
    • /
    • pp.163-170
    • /
    • 2005
  • Track substructure (ballast, subgrade) should have sufficient strength and uniform stiffness to fully support track superstructure (rail, fastener, sleeper). Vertical support stiffness of track is strongly influenced by the condition of ballast and subgrade layers. Therefore, the evaluation of the condition of track substructure is very important to evaluate the vertical support stiffness of track. This paper proposes the trackbed evaluation system, which is composed of Ground Penetrating Radar (GPR), Portable Ballast Sample. (PBS), and Light Falling Weight Deflectomete. (LFWD), to diagnose track substructure. The laboratory and field tests are performed to evaluate the applicability of the proposed trackbed evaluation system.