• Title/Summary/Keyword: Ventilation capacity

Search Result 175, Processing Time 0.023 seconds

The Effects of the Multiple Pulmonary Function in the 20s People of Mild Intellectual Disabilities to Balloons Blowing Exercise (풍선불기운동이 20대 경도 지적장애인의 복합적인 폐기능에 미치는 영향)

  • Seo, Kyo-Chul;Park, Seung-Hwan;Kim, Dae-Rong
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.9
    • /
    • pp.121-126
    • /
    • 2021
  • The purpose of this study is to investigate the effect of balloon blowing exercise on multiple pulmonary function and maximum voluntary ventilation in patients with mild intellectual disabilities in their 20s. 10 people in the experimental group and 10 people in the control group participated in the experiment. The experimental group performed the balloon blowing exercise for 30 minutes a day, and the control group performed the diaphragm breathing exercise for 30 minutes each. The subjects measured voluntary capacity and maximal voluntary ventilation using Fitmate before and after the experiment. Subjects were assessed with Vital capacity(VC) and Maximal voluntary ventilation(MVV) before and after the test and the results were compared with the paired t test. Data analysis was performed with SPSS win 18.0. After the experiment, the experimental group showed higher lung capacity and maximum ventilation than the control group. Through this study, the experimental group increased voluntary capacity and maximum voluntary ventilation more than the control group. It is thought that the quality of life can be improved if we continuously manage the health of intellectuals by developing various breathing exercise programs.

A Study on ventilation characteristics in bidirectional traffic tunnels - with emphasis on the natural ventilation (대면통행 터널의 환기특성에 관한 연구 - 자연환기량을 중심으로)

  • Kim, Hyo-Gyu;Hong, Yoo-Jung;Yoo, Yong-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.6
    • /
    • pp.561-571
    • /
    • 2014
  • The standards of ventilation system for bi-directional tunnel have not been established now. For this reason, with regard to the bi-directional tunnel below 1km, some problems have been appeared in ventilation capacity designing and in determining whether the mechanical ventilation system is needed or not for each case. In this study, we examine the characteristics of natural ventilations, analyze ongoing ventilation design cases for bi-directional tunnels and classify those cases into two groups. This study is carried out about the capability of using natural ventilating system by calculation of reasonable ventilation capacity in bi-directional tunnel and review of relationship between natural wind speed ($Vr^*$) and required speed(Vreq). This paper aims at providing a basis data for bi-directional tunnel ventilation design standards.

Influence of Evjenth-Hamberg Stretching on the Lung Function of Adults with Forward Head Posture

  • Kim, Nyeon Jun;Koo, Ja Pung
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.9 no.4
    • /
    • pp.1663-1668
    • /
    • 2018
  • This study was conducted to examine the effects of Evjenth-Hamberg stretching of the sternocleidomastoid, upper trapezius, and pectoralis major on the lung function of adults with forward neck posture. The subjects were 20 adult students in P university located in Pohang, Korea, whose degree of head forward displacement measured according to NEW YORK state posture test was mild. The subjects were randomly and equally assigned to the Evjenth-Hamberg Stretching group (EHSG, n=10) and the control group (CG, n=10). Their forced vital capacity (FVC), slow vital capacity (SVC), and maximal voluntary ventilation (MVV) were measured before and after the experiment. In within-group comparison, only the EHSG experienced statistically significant improvement in FVC, forced expiratory volume in the first second (FEV1), and peak expiratory flow (PEE) after the experiment, compared to before the experiment (.05

Smoke Control According to the Ventilation Capacity in Subway Tunnel Fire: I. FDS Simulation (지하철 터널 화재시 환기시설의 용량에 따른 제연효과 I. FDS 시뮬레이션)

  • Park, Kyung-Jun;Lee, Ki-Jun;Hadi, Bettar El;Lee, Jai-Hyo;Shin, Dong-Il
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.3
    • /
    • pp.31-38
    • /
    • 2011
  • In this study, we investigate simulation studies to confirm the removal of smoke through ventilation when the subway car is on fire and stopped in an underground subway tunnel, by using Fire Dynamics Simulator (FDS) which is being upgraded by NIST. The structure of subway tunnel and train for simulation modeling are based actual data from Seoul metropolitan subway. The main purpose of this study is to assure the removal efficiency of the ventilation when changing the ventilation capacity between 2.0 m/s and 3.0 m/s. The results of the study shows that carbon monoxide (CO) and carbon dioxide ($CO_2$) are reduced by about 35% as the ventilation capacity is increased by 0.5 m/s. This study also performs the grid sensitivity verification of FDS for improved accuracy of the results. To find the effective size of the grid, three cases are simulated and the results are compared.

A Study on the Effect of Time Lapse After Position Change and Abdominal Band on Pulmonary Function in the Cervical Cord Injuries (척수손상 환자의 자세 변화 후 시간경과와 복대사용이 폐기능에 미치는 영향)

  • Lee, Jae-Ho;Park, Chang-Il;Chon, Joong-Sun
    • Physical Therapy Korea
    • /
    • v.4 no.3
    • /
    • pp.17-33
    • /
    • 1997
  • The objective of this study was to identify pulmonary functional variations in relation to postural changes, lapse after changing position, and the use of abdominal band in the cervical cord injured. The subjects of this study were 19 quadriplegic patients who had been admitted to the department of the Rehabilitation Hospital, College of Medicine, Yousei University, from April, 1997 through May 3, 1997. A spiroanalyzer was used to measure pulmonary function in supine, standing, time after changing position, and recording to the position, application method, and tightness of the abdominal band. The data were analyzed by the repeated measure one-way ANOVA, and Wilcoxon signed rank test. The findings were as follows: 1. All phase of the patients' pulmonary function improved significantly in supine posture in contrast to standing (vital capacity by $0.46{\ell}$ and expiratory reserve volume by $0.09{\ell}$). 2. The longer the time lapsed from supine posture to standing, the patient's expiratory reserve volume, maximum ventilation volume, vital capacity, and forced expiratory volume increased. 3. When the patient lay in supine position, the maximum ventilation volume, vital capacity, and the forced vital capacity increased then the center line of the abdominal band was placed along iliac crest; on the other hand, when the patient was standing, placing the bottom line of the abdominal band along iliac crest increased the maximum ventilation volume, vital capacity, and forced expiratory volume. 4. In placing the abdominal band in the patients, leaving space between the top and bottom lines of the band helped increased in maximum ventilation volume, vital capacity, and forced vital capacity for patient in supine as well as in standing. 5. When placing the abdominal band to patients in supine posture, reducing the length of the band by 2.5% along the patient's waist line increased the patients' vital capacity, while reducing the length by 10% to patients in standing increased the maximum ventilation volume. The abdominal band should be placed in such a way that the bottom part of the band should be more tightly fastened while leaving enough room for a hand to be placed in between the body and the band for the top part of the hand. It should also be noted that in a supine position, the bottom line of the band should be placed along the iliac crest, while in standing, the center line should be placed along the iliac crest. The length of the band should also be reduced by 2.5% of the waist line in supine position, and in standing, the length should be reduced by 10%. It should also be noted that the pulmonary function of the patients should be measured at least 10 minutes after one position change.

  • PDF

A Study on the Behaviour of Smoke Spread Caused by Vehicle Fire in a Road Tunnel (터널 내 차량 화재에 따른 연기 확산 거동에 관한 연구)

  • Yoon, Yong-Kyun;Ju, Eun-Hye
    • Tunnel and Underground Space
    • /
    • v.22 no.5
    • /
    • pp.365-372
    • /
    • 2012
  • This paper aims to evaluate the effects that presence, installation number and capacity of ventilation vent and presence of multiple fire sources have on the behaviour of smoke temperature induced by vehicle fire in road tunnel. Six types of scenarios were assumed and FDS was ran to simulate them. As the number of ventilation vents increases, the smoke temperature are calculated to be reduced, but it is shown that effects exerted by two ventilation vents are almost similar to ones by three ventilation vents. Capacity of ventilation vent has a greater impact on the reduction of smoke temperature than installation number of ventilation vents. Smoke temperatures computed for all scenarios except for scenario No. 1 (without ventilation vent) and scenario No. 6 (with multiple fire sources) above fire source are analyzed to be under $400^{\circ}C$ and it means that the radiation of smoke layer above fire source doesn't induce the ignition of materials around fire source.

A Numerical Analysis on the Indoor Air Ventilation by Stack Effect and Outdoor Wind in a High-rise Residential Building (초고층 주거건물에서 굴뚝효과와 외풍영향에 인한 실내 환기 기류해석 및 평가에 관한 연구)

  • Kim, Chi-Wan;Lim, Tae-Kun;Ahn, Young-Chull
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.12
    • /
    • pp.828-835
    • /
    • 2011
  • The purpose of this study is to analyze and evaluate the 3 types of indoor ventilation methods such as natural, mechanical, and hybrid ventilation in high-rise building which is affected by stack effect and outdoor air pressure. For the evaluation of the ventilation capacity, CFD simulation was performed in a typical high-rise residential building. The results of the simulations are as follows: 1) Natural ventilation method is not enough to the regulation. 2) In case of mechanical ventilation, congested area is occurred but meets the regulation. 3) In case of hybrid ventilation with stack effect, all the areas of indoor meet the regulation and congested area is reduced. 4) In case of high-rise building, the differences of ventilation rate among houses in the building are not large because the mechanical ventilation is main factor.

A Study on Ventilation System of Underground Low-Intermediate Radioactive Waste Repository (지하 동굴식 중-저준위 방사성 폐기물 처분장의 환기시스템 고찰)

  • Kim, Young-Min;Kwon, O-Sang;Yoon, Chan-Hoon;Kwon, Sang-Ki;Kim, Jin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.1
    • /
    • pp.65-78
    • /
    • 2007
  • The pollutants (Rn, CH, CO, HS, radioactive gas from radiolysis) were generated from the process of construction and operation of underground repository, and after disposal of low-intermediate radioactive waste inside there must be controlled by a ventilation system to distribute them in area where enough air is supported. Therefore, a suitable technical approach is needed especially at an underground repository that is equipped with many entry tunnels, storage tunnels, exhaust-blowing tunnels, and vertical shafts in complicated network form. For the technical approach of such a ventilation system, WIPP (Waste Isolation Pilot Plant) in U. S and SFR (Slutforvar for Reaktorafall) low-intermediate radioactive waste repository in Sweden were selected as the models, for calculating the required air quantity, organizing a ventilation network considering cross section, length, surface roughness of the air passage, and describing a calculation of resistance of each circuit. Based on these procedures, a best suited ventilation system was completed with designing proper capacity of fans and operating plan of vertical shafts. As a result of comparing the two repositories based on the geometry dimensions and ventilation facility equipment operation, more parallel circuit as in WIPP, brought decrease in resistance for entire system leading to reduce of operating costs, and the larger cross-sectional area of the SFR, the greater the percentage of disposal capacity. Accordingly, the mixture of parallel circuit of WIPP repository for reducing resistance and SFR repository formation for enlargement of disposal capacity would be the most rational and efficient ventilation system.

  • PDF

Energy and Air Quality Benefits of DCV with Wireless Sensor Network in Underground Parking Lots

  • Cho, Hong-Jae;Jeong, Jae-Weon
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.2
    • /
    • pp.155-165
    • /
    • 2014
  • This study measured and compared the variation of ventilation rate and fan energy consumption according to various control strategies after installing wireless sensor-based pilot ventilation system in order to verify the applicability of demand-controlled ventilation (DCV) strategy that was efficient ventilation control strategy for underground parking lot. The underground parking lot pilot ventilation system controlled the ventilation rate by directly or indirectly tracking the traffic load in real-time after sensing data, using vehicle detection sensors and carbon monoxide (CO) and carbon dioxide ($CO_2$) sensor. The ventilation system has operated for 9 hours per a day. It responded real-time data every 10 minutes, providing ventilation rate in conformance with the input traffic load or contaminant level at that time. A ventilation rate of pilot ventilation system can be controlled at 8 levels. The reason is that a ventilation unit consists of 8 high-speed nozzle jet fans. This study proposed vehicle detection sensor based demand-controlled ventilation (VDS-DCV) strategy that would accurately trace direct traffic load and CO sensor based demand-controlled ventilation (CO-DCV) strategy that would indirectly estimate traffic load through the concentration of contaminants. In order to apply DCV strategy based on real-time traffic load, the minimum required ventilation rate per a single vehicle was applied. It was derived through the design ventilation rate and total parking capacity in the underground parking lot. This is because current ventilation standard established per unit floor area or unit volume of the space made it difficult to apply DCV strategy according to the real-time variation of traffic load. According to the results in this study, two DCV strategies in the underground parking lot are considered to be a good alternative approach that satisfies both energy saving and healthy indoor environment in comparison with the conventional control strategies.

A study on the effects of exhaust emission standards on the required ventilation rate in vehicle tunnels (차량 배출가스 규제기준이 소요환기량에 미치는 연구)

  • Kim, Hyo-Gyu;Ryu, Ji-Oh;Song, Seog-Hun;Jung, Chang-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.3
    • /
    • pp.409-420
    • /
    • 2017
  • The amount of ventilation required in making the tunnel ventilation plan is an important factor for determining the capacity of the ventilation system. The amount of pollutant emission for each type of vehicle (basic emission amount for the design of ventilation volume) for estimating the required ventilation amount is based on the 'Standard for Allowing the Emission for the car manufacturing', proposed by Ministry of Environment. However, in 2013, the Ministry of Environment announced the 'Regulations on the calculation method of total emissions from vehicles' as a regulation for calculating the pollutants emitted from vehicles. In this regulation, there are the 'Emission factors for each type of vehicle'. Therefore, it is necessary to review the application of the Regulation to the estimation of the required ventilation volume for the road tunnel. In this study, the influence of the strengthened emission regulation in 2015 caused by the case of manipulation of emission volume for the diesel vehicle on the calculation of the required ventilation volume in the road tunnel has been checked. In addition, in this study, the required ventilation volume calculated according to the Standard for Allowing the Emission for the car manufacturing revised by Ministry of Environment and "Emission factors for each type of vehicle" and that calculated according to the EURO emission standard were compared for analysis. This study has implications that it provides the basic design data for calculating the reasonable ventilation capacity of the ventilation system based on the ground for calculating the required ventilation volume.