• Title/Summary/Keyword: Variable Input

Search Result 1,461, Processing Time 0.029 seconds

Efficiency analysis of Oriental hospitals according to characteristics (한방병원 특성별 경영효율성 분석)

  • Kim, Young-Sik;Lee, Woo-Chun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.59-67
    • /
    • 2017
  • This study analyzes the efficiency of oriental hospitals using DEA(Data Envelopment Analysis). The input variables include the numbers of doctors, nurses, medical technicians, and beds. The output variable iscomprised of the sales account. The analysis tools used are EnPas and IBM SPSS Statistics 19. As a result of efficiency analysis, the private hospitals(establishment), less than 10 years in operation(operating period), containing less than 50 beds (number of the beds), located in the metropolitan area(location) showed high efficiency in the BCC(Banker, Charnes & Cooper) model, but indicated relatively low efficiency in CCR(Charnes, Cooper & Rhodes) model. This contradictory result is caused by inefficiencies in hospital size. The logistic regression analysis conducted to analyze the variables that affect the efficiency of oriental hospitals found that the efficiency decreased by 0.955 with each increase of 1 bed in the hospital.

The Effects of Wearing Roller Shoes on Muscle Activity in The Lower Extremity During Walking (롤러신발과 일반신발의 착용 후 보행 시 하지근의 근전도 비교)

  • Chae, Woen-Sik;Lim, Young-Tae;Lee, Min-Hyung;Kim, Jung-Ja;Kim, Youn-Joung;Jang, Jae-Ik;Park, Woen-Kyoon;Jin, Jae-Hong
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.3
    • /
    • pp.137-148
    • /
    • 2006
  • The purpose of this study was to compare muscle activity in the lower extremity during walking wearing jogging and roller shoes. Twelve male middle school students (age: 15.0 yrs, height 173.7 cm, weight 587.7 N) who have no known musculoskeletal disorders were recruited as the subjects. Seven pairs of surface electrodes (QEMG8, Laxtha Korea, gain = 1,000, input impedance >$1012{\Omega}$, CMMR >100 dB) were attached to the right-hand side of the body to monitor the rectus femoris (RF), vastus medialis (VM), vastus lateralis (VL), biceps femoris (BF), tibialis anterior (TA), and medial (GM) and lateral gastrocnemius (GL) while subjects walked wearing roller and jogging shoes in random order at a speed of 1.1 m/s. An event sync unit with a bright LED light was used to synchronize the video and EMG recordings. EMG data were filtered using a 10 Hz to 350 Hz Butterworth band-passdigital filter and further normalized to the respective maximum voluntary isometric contraction EMG levels. For each trial being analyzed, five critical instants and four phases were identified from the recording. Averaged IEMG and peak IEMG were determined for each trial. For each dependent variable, paired t-test was performed to test if significant difference existed between shoe conditions (p<.05). The VM, TA, BF, and GM activities during the initial double limb stance and the initial single limb stance reduced significantly when going from jogging shoe to roller shoe condition. The decrease in EMG levels in those muscles indicated that the subjects locked the ankle and knee joints in an awkward fashion to compensate for the imbalance. Muscle activity in the GM for the roller shoe condition was significantly greater than the corresponding value for the jogging shoe condition during the terminal double limb stance and the terminal single limb stance. Because the subjects tried to keep their upper body weight in front of the hip to prevent falling backward, the GM activity for the roller shoe condition increased. It seems that there are differences in muscle activity between roller shoe and jogging shoe conditions. The differences in EMG pattern may be caused primarily by the altered position of ankle, knee, and center of mass throughout the walking cycle. Future studies should examine joint kinematics during walking with roller shoes.

Response of Soil Microbial Communities to Different Cultivation Systems in Controlled Horticultural Land

  • Lee, You-Seok;Kang, Jeong-Hwa;Choi, Kyeong-Ju;Lee, Seong-Tae;Kim, Eun-Seok;Song, Won-Doo;Lee, Young-Han
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.1
    • /
    • pp.118-126
    • /
    • 2011
  • Ester-linked fatty acid methyl ester (EL-FAME) profiles were used to describe differences in soil microbial communities influenced by conventional farming system (CFS), and organic farming system (OFS) in controlled horticultural land. Soil physicochemical properties and soil microbial communities were determined in the experimental fields. Higher organic matter content in OFS reduced soil bulk density which in turn increased the soil porosity. Generally, soil chemical properties in OFS were higher than those of CFS, but EC value in OFS was significantly lower than that of CFS. With the exception of Fe content, other macronutrient contents and pH in both farming system decreased with the soil depth. Soil microbial biomass of OFS was approximately 1.3 times in topsoil and 1.8 times in subsoil higher than those of CFS. Lower ratios of cy17:0 to $16:1{\omega}7c$ and cy19:0 to $18:1{\omega}7c$ were found in the CFS soils than the OFS soils, indicating that microbial stress decreased. The ratio of MUFA to SFA was higher in OFS due to organic input to the soil. In principal components analysis (PCA), the first variable accounted for 54.3%, while the second for 27.3%, respectively. The PC1 of the PCA separated the samples from CFS and OFS, while the PC2 of the PCA separated the samples from topsoil and subsoil. EL-FAMEs with the positive eigenvector coefficients for PC1 were cy17: 0 to $16:1{\omega}7c$ ratio, cy19:0 to $18:1{\omega}7c$ ratio, soil pH, soil organic matter, and soil $NO_3$-N content. Our findings suggest that the shifting cy19:0 to $18:1{\omega}7c$ ratio should be considered as potential factors responsible for the clear microbial community differentiation observed between different cultivation systems and soil depth in controlled horticultural land.

Prediction of multipurpose dam inflow using deep learning (딥러닝을 활용한 다목적댐 유입량 예측)

  • Mok, Ji-Yoon;Choi, Ji-Hyeok;Moon, Young-Il
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.2
    • /
    • pp.97-105
    • /
    • 2020
  • Recently, Artificial Neural Network receives attention as a data prediction method. Among these, a Long Shot-term Memory (LSTM) model specialized for time-series data prediction was utilized as a prediction method of hydrological time series data. In this study, the LSTM model was constructed utilizing deep running open source library TensorFlow which provided by Google, to predict inflows of multipurpose dams. We predicted the inflow of the Yongdam Multipurpose Dam which is located in the upper stream of the Geumgang. The hourly flow data of Yongdam Dam from 2006 to 2018 provided by WAMIS was used as the analysis data. Predictive analysis was performed under various of variable condition in order to compare and analyze the prediction accuracy according to four learning parameters of the LSTM model. Root mean square error (RMSE), Mean absolute error (MAE) and Volume error (VE) were calculated and evaluated its accuracy through comparing the predicted and observed inflows. We found that all the models had lower accuracy at high inflow rate and hourly precipitation data (2006~2018) of Yongdam Dam utilized as additional input variables to solve this problem. When the data of rainfall and inflow were utilized together, it was found that the accuracy of the prediction for the high flow rate is improved.

A Study on the Operating Efficiency of Parcel Delivery Sub-terminal Agency focus on A company (택배서브터미널 대리점 운영효율성에 관한 연구 (A사를 중심으로))

  • Yoon, Sung-Goo;Park, Sung-Hoon;Ma, Hye-Min;Yeo, Gi-Tae
    • Journal of Digital Convergence
    • /
    • v.15 no.10
    • /
    • pp.31-43
    • /
    • 2017
  • This study was aimed at analyzing the operational efficiency of DPAs(the delivery and pickup agents), which serve as sub-terminals in parcel delivery services, using CCR/BCC models in DEA. The input variables included the number of employees, and the amount of equipment and the operating expenses. The output variable was revenue value. The efficiency for the period from 2014 to 2016 was analyzed. The results revealed that the operational efficiency improved in 2016, compared with 2014, in both CCR and BCC models. According to the benchmarking analysis, DMU 1 and DMU 7 showed higher efficiency in 2016. The inefficiency analysis based on the BCC model showed increased efficiency of all factors in 2016 when compared with 2014. The Malmquist productivity index (MPI) dropped slightly as a result of technical changes and indicated a declining technical efficiency in all DMUs. This study suggests the need for government-led systematic improvement and support for DPAs by providing current insight into the parcel delivery industry and analyzing DPAs' operational efficiency in Korea for the first time. This research performed efficiency analysis of DPAs located in new town of paju and gimpo cities. In future research, comparative study on efficiency analysis including new town, old town area, and other cities are needed.

A Study on T5 28W Fluorescent Lamp Ballast Using a Piezoelectric Transformer and One-chip Microcontroller (One Chip Microcontroller와 압전변압기를 이용한 T5 28W 형광등용 전자식 안정기에 관한 연구)

  • 황락훈;류주현;장은성;조문택;안익수;홍재일
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.1
    • /
    • pp.70-79
    • /
    • 2003
  • In this paper, T5 28-watt fluorescent lamp ballast using a piezoelectric transformer is fabricated and its characteristic is investigated. Developed electronic ballast is composed of basic circuits and blocks, such as rectifier part, active power factor corrector part, frequency oscillation part using microcontroller and feedback control, piezoelectric transformer and resonant half bridge inverters. The fabricated ballast uses to variable frequency methode in external so exciting that the frequency of piezoelectric transformer could be generated by voltage control oscillator using microcontroller(AT90S4433). The current of fluorescent lamp is detected by feedback control circuit. The signal of inverter output is received using Piezoelectric transformer, and then its output transmitted to fluorescent lamp. Traditional electromagnetic ballasts operated at 50-60Hz have been suffered from noticeable flicker, high loss, large crest factor and heavy weight. A new electronic ballast is operated at high frequency about 75kHz, and then Input power factor, distortion of total harmonic and lamp current crest factor are measured about 0.9!35, 12H and 1.5, respectively Accordingly, the traditional ballast is by fabricated electronic ballast using piezoelectric transformer and voltage control oscillator because of its lighter weight, high efficiency, economic merit and saving energy.

A High-Efficiency, Robust Temperature/voltage Variation, Triple-mode DC-DC Converter (고효율, Temperature/voltage 변화에 둔감한 Triple-mode CMOS DC-DC Converter)

  • Lim, Ji-Hoon;Ha, Jong-Chan;Kim, Sang-Kook;Wee, Jae-Kyung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.6
    • /
    • pp.1-9
    • /
    • 2008
  • This paper suggests the triple-mode CMOS DC-DC converter that has temperature/voltage variation compensation techniques. The proposed triple-mode CMOS DC-DC converter is used to generate constant or variable voltages of 0.6-2.2V within battery source range of 3.3-5.5V. Also, it supports triple modes, which include Pulse Width Modulator (PWM) mode, Pulse Frequency Modulator (PFM) mode and Low Drop-Out (LDO) mode. Moreover, it uses 1MHz low-power CMOS ring oscillator that will compensate malfunction of chip in temperature/voltage variation condition. The proposed triple-mode CMOS DC-DC converter, which generates output voltages of 0.6-2.2V with an input voltage sources of 3.3-5.5V, exhibits the maximum output ripple voltage of below 10mV at PWM mode, 15mV at PFM mode and 4mV at LDO mode. And the proposed converter has maximum efficiency of 93% at PWM mode. Even at $-25{\sim}80^{\circ}C$ temperature variations, it has kept the output voltage level within 0.8% at PWM/PFM/LDO modes. For the verification of proposed triple-mode CMOS DC-DC converter, the simulations are carried out with $0.35{\mu}m$ CMOS technology and chip test is carried out.

A Study on Prototype Model for Mesoscopic Evacuation Using Cube Avenue Simulation Model (Cube Avenue 시뮬레이션 모델을 이용한 중규모 재난대피 프로토타입 모델 연구)

  • Sin, Heung Gweon;Joo, Yong Jin
    • Spatial Information Research
    • /
    • v.21 no.5
    • /
    • pp.33-41
    • /
    • 2013
  • Recently, the number of disasters has been seriously increasing. The total damages by the natural or man-made disasters during the past years resulted in tremendous fatalities and recovery costs. It is necessary to have efficient emergency evacuation management which is concerned with identifying evacuation route, and the estimation of evacuation and clearance times. An emergency evacuation model is important in identifying critical locations, and developing various evacuation strategies. In that existing evacuation models have focused on route analysis for indoor evacuation, there are only a few models for areawide emergency evacuation analysis. Therefore, we developed a mesoscopic model by using Cube Avenue and performed evacuation simulation, targeting road network in City of Fargo, North Dakota. Consequently, a mesoscopic model developed in this study is used to carry out dynamic analysis using network and input variable of existing travel demand model. The results of this study show that the model is an appropriate tool for areawide emergency evacuation analysis to save time and cost. Henceforth, the results of this study can be applied to develop a disaster evacuation model which can be used for a variety of disaster simulation and evaluation based on scenarios in the local metropolitan area.

Quantitative Analysis of Dynamic PET images in Cardiac patients using Patlak tool on GE PET workstation

  • Son, Hye-Kyung;Mijin Yun;Kim, Dong-Hyeon;Haijo Jung;Lee, Jong-Doo;Yoo, Hyung-Sik;Kim, Hee-Joung
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.314-317
    • /
    • 2002
  • The purpose of this study was to evaluate the clinical application of Patlak tool on GE PET workstation for quantitative analysis of dynamic PET images in cardiac patients. Three patients including coronary artery disease (CAD), myocardial infarction (MI), and angina were studied. All subjects underwent dynamic cardiac PET scan using a GE Advance scanner. After 10 min transmission scan for attenuation correction using two rotating $\^$68/Ge rod sources, three patients with cardiac disease were performed dynamic cardiac PET scan after the administration of approximately 370 MBq of FDG. The dynamic scan consisted of 36 frames with variable frame length (12${\times}$10s, 6${\times}$20s, 6${\times}$60s, 12${\times}$300s) for a total time of 70 min. Blood samples were obtained to determine the plasma substrate concentration. Region of interest of circular and rectangular shape to acquire input functions and tissue data were placed on left ventricle and myocardium. A value of 0.67 was used for lumped constant. Mean plasma substrate concentrations for three patients were 100 mg/dl (CAD), 100 mg/dl (MI), 132 mg/dl (angina), respectively. Regional MMRGlc values (mean${\pm}$SD) at lateral myocardium area for CAD, MI, and angina were 8.43${\pm}$0.24, 4.08${\pm}$0.16, and 6.15${\pm}$0.23 mg/min/100ml, respectively. Patlak tool on GE PET workstation appeared to be useful for quantitative analysis of dynamic PET images in cardiac patients, although further studies may be required for absolute quantitation.

  • PDF

Design of Low Power 4th order ΣΔ Modulator with Single Reconfigurable Amplifier (재구성가능 연산증폭기를 사용한 저전력 4차 델타-시그마 변조기 설계)

  • Sung, Jae-Hyeon;Lee, Dong-Hyun;Yoon, Kwang Sub
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.5
    • /
    • pp.24-32
    • /
    • 2017
  • In this paper, a low power 4th order delta-sigma modulator was designed with a high resolution of 12 bits or more for the biological signal processing. Using time-interleaving technique, 4th order delta-sigma modulator was designed with one operational amplifier. So power consumption can be reduced to 1/4 than a conventional structure. To operate stably in the big difference between the two capacitor for kT/C noise and chip size, the variable-stage amplifier was designed. In the first phase and second phase, the operational amplifier is operating in a 2-stage. In the third and fourth phase, the operational amplifier is operating in a 1-stage. This was significantly improved the stability of the modulator because the phase margin exists within 60~90deg. The proposed delta-sigma modulator is designed in a standard $0.18{\mu}m$ CMOS n-well 1 poly 6 Metal technology and dissipates the power of $354{\mu}W$ with supply voltage of 1.8V. The ENOB of 11.8bit and SNDR of 72.8dB at 250Hz input frequency and 256kHz sampling frequency. From measurement results FOM1 is calculated to 49.6pJ/step and FOM2 is calculated to 154.5dB.