• Title/Summary/Keyword: V.A.K.

Search Result 24,951, Processing Time 0.053 seconds

Isolation and Identification of Vibrio vulnificus and Vibrio parahaemolyticus from Coast of Pusan and Daechon (부산과 대천 해안에서 Vibrio vulnificus와 Vibrio parahaemolyticus의 분리 및 동정)

  • Ju, Jin-Woo;Park, Min-Jung;Heo, Moon-Soo;Jung, Cho-Rok
    • The Journal of the Korean Society for Microbiology
    • /
    • v.35 no.4
    • /
    • pp.309-316
    • /
    • 2000
  • This study was focused on the isolation of pathogenic Vibrio species, V. vulnificus and V. parahaemolyticus from marine environment from May to July of 1999. Isolation sites were coast near by Pusan and Daechon. The results obtained were as follows: 1. Seventy strains of V. parahaemolyticus and 19 strains of V. vulnificus were isolated from a total of 120 specimens. 2. Nineteen strains of V. vulnificus did not fermented arabinose and salicin but fermented lactose and cellobiose. All of V. parahaemolyticus isolates did not fermented lactose and cellobiose. 47 strains of V. parahaemolyticus fermented arabinose but 53 strains did not fermented salicin. 3. V. vulnificus and V. parahaemolyticus isolates showed three different API index numbers with 5046105 and 4346107 dominant. 4. V. vulnificus did not grow on 0% and 8% NaCl containing medium. V. parahaemolyticus grew on 8% NaCl containing medium. 5. V. vulnificus isolates and V. parahaemolyticus revealed different outer membrane protein profiles on SDS-PAGE.

  • PDF

Thermal and Mechanical Properties of Insulation Materials for Underground Power Cable (지중 전력케이블용 절연재료의 열적 특성 및 기계적 특성)

  • Lee, Kyoung-Yong;Lee, Kwan-Woo;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.138-141
    • /
    • 2004
  • In this paper, we Investigated effects on impurities and water of semiconductive shield through a thermal, mechanical, and absorption experiment to estimate performance of insulating materials in power cable. Specimens had been prepared 22[kV], 154[kV] XLPE power cables and then were made of sheet form with XLPE and semiconductive shield with dimension of 0.4[mm] ~1.2[mm] of thickness from power cable. Heat capacity $({\Delta}H)$ and glass trasition temperature (Tg) of XLPE sheet were measured by DSC (Differential Scanning Calorimetry). We could know that thermal stabilities of 154[kV] are more excellent than 22[kV] from this experimental result. The strain of mechanical properties in 22[kV] and 154[kV] XLPE was 486[%], 507[%] and stress was 1.74$[kgf/mm^2]$, 1.80$[kgf/mm^2]$. The absorption contents of existing semiconductive shield were measured 710[ppm] to 1,090[ppm], and semiconductive shield of 22[kV] cable was measured 14,750[ppm] to 24,780[ppm]. We thermal and mechanical properties of 154[kV] could know more excellent than 22[kV] from this experimental result.

  • PDF

Effect of Channel Length and Drain Bias on Threshold Voltage of Field Enhanced Solid Phase Crystallization Polycrystalline Thin Film Transistor on the Glass Substrate (자계 유도 고상결정화를 이용한 다결정 실리콘 박막 트랜지스터의 채널 길이와 드레인 전압에 따른 문턱 전압 변화)

  • Kang, Dong-Won;Lee, Won-Kyu;Han, Sang-Myeon;Park, Sang-Geun;Han, Min-Koo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1263-1264
    • /
    • 2007
  • 자계 유도 고상결정화(FESPC)를 이용하여 제작한 다결정실리콘(poly-Si) 박막 트랜지스터(TFT)는 비정질 실리콘 박막 트랜지스터(a-Si:H TFT)보다 뛰어난 전기적 특성과 우수한 안정성을 지닌다. $V_{DS}$ = -0.1 V에서 채널 폭과 길이가 각각 $5\;{\mu}m$, $7\;{\mu}m$인 P형 TFT의 이동도(${\mu}$)와 문턱 전압($V_{TH}$)은 각각 $31.98\;cm^2$/Vs, -6.14 V 이다. FESPC TFT는 일반 poly-Si TFT에 비해 채널 내 결정 경계 숫자가 많아서 상대적으로 열악한 특성을 가진다. 채널 길이 $5\;{\mu}m$인 TFT의 $V_{TH}$는 채널 길이 $18\;{\mu}m$ 소자의 $V_{TH}$보다 1.36V 작지만, 일반적으로 큰 값이다. 이 현상은 채널에 다수의 결정 경계가 존재하고, 수평 전계가 크기 때문이다. 수평 전계가 증가하면, 결정 경계의 전위 장벽 높이가 감소하게 되는데, 이는 DIGBL 효과이다. ${\mu}$의 증가에 따라서, 드레인 전류가 증가하고 $V_{TH}$은 감소한다. 활성화 에너지($E_a$)는 드레인 전압과 결정 경계의 수에 따라 변하는데, 드레인 전압이 크거나 결정 경계의 수가 감소하면 $E_a$는 감소한다. $E_a$가 감소하면 $V_{TH}$가 감소한다. 유리기판 위의 FESPC를 이용한 P형 poly-Si TFT의 $V_{TH}$는 채널의 길이와 $V_{DS}$에 영향을 받는다. 증가한 수평 전계가 결정 경계에서 에너지 장벽을 낮추는 효과를 일으키기 때문이다.

  • PDF

Fabrications and Properties of MFIS Structures using high Dielectric AIN Insulating Layers for Nonvolatile Ferroelectric Memory (고유전율 AIN 절연층을 사용한 비휘발성 강유전체 메모리용 MFIS 구조의 제작 및 특성)

  • Jeong, Sun-Won;Kim, Gwang-Hui;Gu, Gyeong-Wan
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.11
    • /
    • pp.765-770
    • /
    • 2001
  • Metal-ferroelectric-insulator- semiconductor(MFTS) devices by using rapid thermal annealed (RTA) LiNbO$_3$/AIN/Si(100) structures were successfully fabricated and demonstrated nonvolatile memory operations. Metal-insulator-semiconductor(MIS) C-V properties with high dielectric AIN thin films showed no hysteresis and good interface properties. The dielectric constant of the AIN film calculated from the capacitance at the accumulation region in the capacitance-voltage(C-V) characteristics was about 8. The C-V characteristics of MFIS capacitor showed a hysteresis loop due to the ferroelectric nature of the LiNbO$_3$ thin films. Typical dielectric constant value of LiNbO$_3$ film of MFIS device was about 23. The memory window width was about 1.2 V at the gate voltage of $\pm$5 V ranges. Typical gate leakage current density of the MFIS structure was the order of 10$^{-9}$ A/$\textrm{cm}^2$ at the range of within $\pm$500 kV/cm. The ferroelectric capacitors showed no polarization degradation up to about 10$^{11}$ switching cycles when subjected to symmetric bipolar voltage pulse(peak-to-peak 8 V, 50 % duty cycle) in the 500 kHz.

  • PDF

Expression of p53, CD44v6 and VEGF in Gastric Adenocarcinomas (위선암종의 예후인자로서 p53, CD44v6과 VEGF 단백 발현)

  • Park, Eon-Sub;Lee, Chang-Young;Lee, Tae-Jin;Kim, Mi-Kyung;Yoo, Jae-Hyung
    • Journal of Gastric Cancer
    • /
    • v.1 no.1
    • /
    • pp.10-16
    • /
    • 2001
  • Purpose: The p53 protein is a tumor supressor gene, and its mutation is associated with biologic aggressiveness. CD44v6, one of the CD44 family, is a cell surface glycoprotein that plays a role in cancer invasion and metastasis. Vascular endothelial growth factor (VEGF) is another recently identified growth factor with significant angiogenic properties. The purpose of this study was to investigate p53, CD44v6, and VEGF expressions to determine whether degree of expression was related to pathological parameters such as Lauren's classification, depth of invasion, and lymph node metastasis. Materials and Methods: Immunohistochemical stains of p53, CD44v6, and VEGF in formalin-fixed paraffin-embedded tissue sections of 125 gastric adenocarcinomas were done. Results: The overall expression rates of p53, CD44v6, and VEGF were $54.4\%$ (68/125), $36.8\%$ (46/125), and $48.0\%$ (60/125), respectively. The p53, not CD44v6 and VEGF was higher in intestinal-type gastric carcinomas by Lauren's classification. The expressions of p53, CD44v6, and VEGF were statistically correlated with depth of tumor invasion. The expression of CD44v6 was higher in the lymph node metastatic group than in the negative group. The p53 expression was significantly associated with VEGF expression. Conclusions: These data suggest that the expressions of p53, CD44v6, and VEGF are biologically related to malignancy. The p53 and CD44v6 expressions are independent; however, p53 gene mutation is one of the contributing factors to VEGF expression in gastric adenocarcinoma.

  • PDF

Vibrios Isolated from Diseased Marine Culturing Fishes in Korea (질병의 증상을 보이는 해수 양식 어류에서 분리한 비브리오속 세균)

  • Kim, Su-Mi;Won, Kyung-Mi;Woo, Sung-Ho;Li, Hua;Kim, Eun-Jeon;Choi, Kwang-Jin;Cho, Mi-Young;Kim, Myung-Suk;Park, Soo-Il
    • Journal of fish pathology
    • /
    • v.18 no.2
    • /
    • pp.133-146
    • /
    • 2005
  • A bacteriological survey in maricultured fish farms was conducted in Korea from 2002 to 2004. A total number of 166 Vibrio isolates were collected from diseased fishes, including olive flounder (133 isolates), black rock fish (8 isolates), red sea bream (6 isolates), shrimp (5 isolates), black sea bream (4 isolates), abalone (3 isolates) and other fishes (7 isolates). All isolates were phenotypically characterized and then groups were obtained using the traditional biochemical test. Representative isolates of each group were genotypically characterized with sequencing the 16S rRNA genes or 16S-23S intergenic space genes. Above 14 species of Vibrio were identified as V. ichthyoenteri (45 strains), V. alginolyticus (34 strains), V. harveyi (32 strains), Ph. damselae subsp. damselae (Formerly V. damsela, 10 strains), V. campbellii (6 strains), V. costicola-like (6 strains), V. fisheri (5 stains), V. fluvialis (4 strains) and others Vibrio sp. (24 strains) by combining of biochemial and genetic characteristics.

Separation Performance of Zigzag Air Classifier

  • Hirajima, Tsuyoshi;Nishida, Takuji;Toshima, Ryutaro;Kataoka, Kenji;Tsunekawa, Masami;Asakura, Kuniomi
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.759-764
    • /
    • 2001
  • The separation performance of zigzag air classifier with angle of 90 degrees was studied using narrow size fractions of thin square samples and granular samples. The simulation results of air velocity inside the classifier indicated that the zigzag geometry induces a new pattern consisting of an upward flow and a circulation flow, Experimental results showed that overflow product recovery was described as an integral calculus of normal distribution as a function of dimensionless air velocity ( $V_{A}$ $V_{A50}$), where $V_{A}$ is superficial air velocity and $V_{A50}$ is the $V_{A}$ at the fifty percent recovery. The $V_{A}$ values were predicted using the equations derived from dynamics for a particle dropping in air. A monitoring system that utilizes changes in acoustic signals emitted during the process of air classification was developed to separate PET with desired recovery or grade. The technical feasibility of the on-line monitoring of the PET recovery and grade was demonstrated by measuring relative energy of the signals.signals.als.

  • PDF

Electron-excitation Temperature with the Relative Optical-spectrumIntensity in an Atmospheric-pressure Ar-plasma Jet

  • Han, Gookhee;Cho, Guangsup
    • Applied Science and Convergence Technology
    • /
    • v.26 no.6
    • /
    • pp.201-207
    • /
    • 2017
  • An electron-excited temperature ($T_{ex}$) is not determined by the Boltzmann plots only with the spectral data of $4p{\rightarrow}4s$ in an Ar-plasma jet operated with a low frequency of several tens of kHz and the low voltage of a few kV, while $T_{ex}$ can be obtained at least with the presence of a high energy-level transition ($5p{\rightarrow}4s$) in the high-voltage operation of 8 kV. The optical intensities of most spectra that are measured according to the voltage and the measuring position of the plasma column increase or decay exponentially at the same rate as that of the intensity variation; therefore, the excitation temperature is estimated by comparing the relative optical-intensity to that of a high voltage. In the low-voltage range of an Ar-jet operation, the electron-excitation temperature is estimated as being from 0.61 eV to 0.67 eV, and the corresponding radical density of the Ar-4p state is in the order of $10^{10}{\sim}10^{11}cm^{-3}$. The variation of the excitation temperature is almost linear in relation to the operation voltage and the position of the plasma plume, meaning that the variation rates of the electron-excitation temperature are 0.03 eV/kV for the voltage and 0.075 eV/cm along the plasma plume.

Spectral CT Analysis of Hounsfield Unit (HU) according to MonoE (keV) and Dilution Ratio of the Contrast Agent: Use of Spectral CT (단색에너지(keV)와 조영제 희석비율 변화에 따른 HU(Hounsfield Unit)값 분석: Spectral CT 이용)

  • Jung, Hee-Ra;Kang, Jin-woo;Kwon, Oh-Jun;Kim, Ho-Jin;Jung, Dabin;Lee, Jae-Hyun;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.669-676
    • /
    • 2020
  • The purpose of this study was to analyze the changes in the values of Hounsfield Unit (HU) according to the changes in monoenergy (keV) and dilution ratio of the contrast agent, using the spectral CT. Spectral CT was used as the testing device, while 20 cc syringe phantom was used to set a total of six dilution ratios of the contrast agent: 8:2, 7:3, 6:4, 5:5, 4:6, and 3:7. Here, the non-ionic iodine solution (350 mg/ml) was used as a contrast agent. The syringe axial image was reconstructed by adjusting the obtained data on nine MonoE levels; 40 keV, 45 keV, 50 keV, 55 keV, 60 keV, 65 keV, 70 keV, 75 keV, and 80 keV. The HU values were measured at the three points of the reconstructed syringe axial image. The measurements were taken 1,620 times in total. In the analysis of the HU values according to the changes in keV and dilution ratio of the contrast agent, the highest and lowest HU values were obtained from dilution ratio 8:2 and dilution ratio 3:7, respectively, across every MonoE in the comparison of HU according to dilution ratio per MonoE (p<0.05), while the highest and lowest HU values were obtained from 40 keV and 80 keV, respectively, across all dilution ratios in the comparison of HU according to MonoE per dilution ratio (p<0.05). For the correlation per each parameter, a negative correlation of -15.014 ± 0.298 was found for HU per keV (R2=0.519) and a negative correlation of -61.372 ± 3.608 was found for HU per dilution ratio (R2=0.152) (p<0.05). To conclude, an increase in keV or dilution ratio of the contrast agent was shown to decrease the HU, and the findings in this study are anticipated to serve as the basic data in the research of HU-related parameters in Spectral CT.

Reducing Methods of Patient's Exposed Dose Using Auto Exposure Control System in Digital Radiography (디지털 방사선장비에서 자동노출제어 사용 시 환자피폭선량 감소 방안)

  • Shin, Seong-Gyu
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.111-122
    • /
    • 2013
  • This study was carried out to reduce patient dose through focus-detector distance, kilovoltage, and a combination of copper filters. In the C, L-spine lateral, Skull AP views were obtained by making changes of 60-100 kV in tube voltage and of 100-200 cm in focus-detector distance and by adding a copper filter when using an auto exposure control device in the digital radiography equipment. The incident dose showed 90 kV, 0.3 mmCu in C-spine lateral with 0.06 mGy under the condition of 200 cm; 100 kV, 0.3 mmCu with 0.40 mGy under the condition of 200 cm and 90 kV 0.3 mmCu in Skull AP with the lowest value of 0.24 mGy under the condition of 140 cm. It was observed that entrance surface dose decreased the most when was increased by 150 cm, 70 kV (C-spine lateral), 81 kV (L-spine lateral). It was also found out that as the between the focus-detector increased in the expansion of the video decreased but the difference was not significant when the distance was 180 cm or more. Skull AP showed the most reduction in the entrance surface dose when the tube voltage was changed by 80 kV, 0.1 mmCu, and 120 cm. Therefore, when using the automatic exposure control device, it is recommended to use the highest tube voltage if possible and to increase focus-detector distance at least by 150~200 cm in wall and 120~140 cm in table in consideration of the radiotechnologist's physical conditions, and to combine 0.1~0.3 mmCu and higher filters. It is thus expected to reduce patient dose by avoiding distortion of images and reducing the entrance surface dose.