Thermal and Mechanical Properties of Insulation Materials for Underground Power Cable

지중 전력케이블용 절연재료의 열적 특성 및 기계적 특성

  • 이경용 (원광대학교 전기전자 및 정보공학부) ;
  • 이관우 (원광대학교 전기전자 및 정보공학부) ;
  • 최용성 (원광대학교 전기전자 및 정보공학부) ;
  • 박대희 (원광대학교 전기전자 및 정보공학부)
  • Published : 2004.05.21

Abstract

In this paper, we Investigated effects on impurities and water of semiconductive shield through a thermal, mechanical, and absorption experiment to estimate performance of insulating materials in power cable. Specimens had been prepared 22[kV], 154[kV] XLPE power cables and then were made of sheet form with XLPE and semiconductive shield with dimension of 0.4[mm] ~1.2[mm] of thickness from power cable. Heat capacity $({\Delta}H)$ and glass trasition temperature (Tg) of XLPE sheet were measured by DSC (Differential Scanning Calorimetry). We could know that thermal stabilities of 154[kV] are more excellent than 22[kV] from this experimental result. The strain of mechanical properties in 22[kV] and 154[kV] XLPE was 486[%], 507[%] and stress was 1.74$[kgf/mm^2]$, 1.80$[kgf/mm^2]$. The absorption contents of existing semiconductive shield were measured 710[ppm] to 1,090[ppm], and semiconductive shield of 22[kV] cable was measured 14,750[ppm] to 24,780[ppm]. We thermal and mechanical properties of 154[kV] could know more excellent than 22[kV] from this experimental result.

Keywords