• Title/Summary/Keyword: Use of Facility

Search Result 1,738, Processing Time 0.031 seconds

Hardware Design and Implementation of Block Encryption Algorithm ARIA for High Throughput (High Throughput을 위한 블록 암호 알고리즘 ARIA의 하드웨어 설계 및 구현)

  • Yoo, Heung-Ryol;Lee, Sun-Jong;Son, Yung-Deug
    • Journal of IKEEE
    • /
    • v.22 no.1
    • /
    • pp.104-109
    • /
    • 2018
  • This paper presents a hardware design for the block encryption algorithm of ARIA which is used for standard in Korea. It presents a hardware-efficient design to increase the throughput for the ARIA algorithm using a high-speed pipeline architecture. We have used ROM for the S-box implementation. This approach aims to decrease the critical path delay of the encryption. In this paper, hardware was designed by VHDL, realized RTL level by Synplify which is synthesis tool and verified simulation by ModelSim. The ARIA algorithm is shown 68.3 MHz (Maximum operation frequency) to use Xilinx VertxE XCV Series device.

Irrigation Facility for Agricultural Use of Rokugo Alluvial Fan in Yokote Basin, Northeastern Japan (일본 동북지방 요코테 분지 내 로쿠고 선상지의 농업적 토지이용을 위한 관개시설 - 원통형 사이펀(siphon) 방식 분수공(分水工)을 대상으로-)

  • Kim Tae-Ho;Son Ill
    • Journal of the Korean Geographical Society
    • /
    • v.41 no.4 s.115
    • /
    • pp.507-512
    • /
    • 2006
  • This paper introduces an irrigation facility for agricultural use of Rokugo alluvial fan in Yokote Basin, northeastern Japan. A cylindrical distributor of agricultural water is able to supply water accurately to seven irrigated areas through its 180 orifices and one circular baffle, implying that people around fan areas has been tenacious of agricultural water. It has been recently reevaluated as tourism resources or symbolic landscape reflecting regional characteristics even though its functional value has decreased.

Land Suitability Analysis of Collective Facility Area in the Kimhae Daechung Park using Geographic Information System and Multi-Criteria Evaluation (GIS와 다요소의사결정방법(MCE)에 의한 김해 대청공원 집단시설지구 적지분석)

  • Hwang, Kook-Woong;Lee, Kyu-Wan
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.3 no.3
    • /
    • pp.45-53
    • /
    • 2000
  • Geographical Information Systems(GIS) overlay analyses, while ideal for performing spatial searches on nominally mapped criteria, are of limited use when multiple uncertian criteria are concerned. But, Multi-Criteria Evaluation(MCE) techniques offer a means of making complex siting decisions, involving multiple criteria. The integration of GIS and MCE techniques became rational and objective approach to perform land suitability analysis on the basis of multiple criteria. An example application based on the search for suitable sites for the collective facility area in the kimhae daechung park using IDRISI is described.

  • PDF

Slitting Test of Simulated Fuel Rod by Using a Newly Developed Decladding Device (실증용 탈피복 장치를 이용한 모의 핵연료 슬릿팅 시험)

  • Jung, J.H.;Hong, D.H.;Kim, Y.H.;Park, B.S.;Lee, J.K.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2006.05a
    • /
    • pp.141-144
    • /
    • 2006
  • In this study, we developed a decladding device which separates 250 mm length of simulated nuclear spent fuel rod into the pallets and the pieces of the hulls after inserting the rod cut into the module with several pairs of blades. To improve the performance of the equipment, we considered some mechanisms to prevent the rod cut from being exposed or bounced into the hot-cell, to reduce the operation time, and to insert the rods automatically. It is expected that the newly developed system will contribute to prevent radioactive pollution in the hot-cell, reduce the operation time, and to increase the safety of the operators. As a result of the performance test for some mockup fuel rod cuts in the ACP(Advanced Spent Fuel Control Process) facility, it was verified that the decladding device could be applied to the actual fuel rod cut. And it will be able to use for a scale-up facility in the future.

  • PDF

The MARS Simulation of the ATLAS Main Steam Line Break Experiment

  • Ha, Tae Wook;Yun, Byong Jo;Jeong, Jae Jun
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.112-122
    • /
    • 2014
  • A main steam line break (MSLB) test at the ATLAS facility was simulated using the best-estimate thermal-hydraulic system code, MARS-KS. This has been performed as an activity at the third domestic standard problem for code benchmark (DSP-03) that has been organized by Korea Atomic Energy Research Institute (KAERI). The results of the MSLB experiment and the MARS input data prepared for the previous DSP-02 using the ATLAS facility were provided to participants. The preliminary MSLB simulation using the base input data, however, showed unphysical results in the primary-to-secondary heat transfer. To resolve the problems, some improvements were implemented in the MARS input modelling. These include the use of fine meshes for the bottom region of the steam generator secondary side and proper thermal-hydraulics calculation options. Other input model improvements in the heat loss and the flow restrictor models were also made and the results were investigated in detail. From the results of simulations, the limitations and further improvement areas of the MARS code were identified.

Cognition of oral health education and dental caries preventive effect in kindergartens and child care facilities (일부 유치원 및 보육시설 유아교사의 구강보건교육 유무에 따른 구강보건교육 및 치아우식예방효과 인식)

  • Jung, Yu Yeon;Choi, Mi-Hye
    • Journal of Korean society of Dental Hygiene
    • /
    • v.14 no.1
    • /
    • pp.17-24
    • /
    • 2014
  • Objectives : The purpose of this study was to investigate cognition on oral health education and dental caries preventive effect in kindergartens and child care facilities. Methods : A self-reported questionnaire was completed by 260 teachers in kindergartens and nursery facility in Daejeon from January to February, 2013. Except incomplete answers, 248 questionnaires were analyzed by using the statistical package SPSS WIN 18.0. Results : High intention to participate in oral health education was shown in the teachers who experienced the oral health education. Dental caries preventive effect included correct tooth brushing, fluoride dentifrice, fluoride mouth rinse, and use of xylitol. The teachers agreed that the fluoride mouth rinses would help good oral health in the children. Conclusions : Teachers in kindergartens and nursery facility are the most important persons in childhood oral health care. So it is necessary to provide the continuing standardized education for the teachers systematically.

A Study on Rail Station-Influenced Area Development Combined with the Optimal Connection and Transfer Facility (적정연계환승체계를 감안한 역세권개발방안에 관한 연구)

  • Chung, Chul;Kim, Sigon;Kim, Yeonkyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.5D
    • /
    • pp.519-525
    • /
    • 2012
  • This study suggests 3 different elements to develop a rail station-influenced area effectively. Above all, several typical models of TOD (Transit Oriented Development)are suggested. They consider the land use types around a rail station, characteristics of a rail station whether it serves a single line or multiple lines. a method of developing a rail station-influenced area. Secondly, the optimal level of service is suggested for connection facility and access modes. Finally, the allocation criteria of on-and-off facility to provide convenient transfer activity.

Analysis of earthquake countermeasure for electrical facility at building (건축물에 시설되는 수변전설비의 지진 대책에 대한 조사 분석)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Jean, Hyun-Jae;Bae, Suk-Myong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.359-362
    • /
    • 2008
  • Middle domestic the occurrence size which stews recently from the Korean Peninsula circumference country is augmenting on a large scale about earthquake about safe countermeasure part from the existing Natural Countermeasure Law 2008. Refers with the Earthquake Disaster Countermeasure Law to be new standard contents establishment by law and strengthened in March. Consequently the research is propelled about electric equipment earthquake-proof plan and countermeasure. The present paper investigated an equipment by domestic facility present condition about the change disappointment electric equipment which can supply all the member in the building an investigation analysis about problem point and improvement fact. Also about overseas electric equipment investigated about earthquake-proof plan relation system and facility present condition. Investigated the electric equipment earthquake-proof plan pertinent data which is advanced from like this existing nation and the equipment and application direction must apply to domestic presented. With character presents following the guide about electric equipment earthquake-proof plan becomes feed with the fact that will be able to use.

  • PDF

A Study on IFC extended and GIS linkage using BIM as Facility Management - Case Study on Bridge and Tunnel of Infra BIM - (BIM을 유지관리로 활용하는 IFC 확장 및 GIS 연계 연구 - 기반시설 BIM의 교량, 터널 중심으로 -)

  • Chae, Jae-Hyun;Choi, Hyun-Sang;Lee, Ji-Yeong
    • Journal of KIBIM
    • /
    • v.12 no.3
    • /
    • pp.1-17
    • /
    • 2022
  • As the technology of Smart City and Digital Twin is developing, techniques to integrate BIM data of infrastructure facilities into GIS are becoming more critical. Hence, this study aims to manage BIM data representing bridge and tunnel structures through the Industry Foundation Classes (IFC) standard and to develop a method to link these IFC-compliant files to the GIS standard CityGML without loss of information. We analyze the criteria for creating BIM data for bridges and tunnels by reviewing the BIM guidelines set by each client. We use these criteria to suggest methods for data management based on InfraBIM as a specific IFC class standard. Furthermore, we perform model analysis to determine the necessary design and construction field-appropriate model process and Level of Detail (LOD). From the model analysis, we conclude that the classified BIM models can be used as base data to generate BIM models of bridges and tunnels for facility management.

A Study on the Fire Protection System in the Stage (공연장의 소방시설 설치기준의 개선방안에 관한 연구)

  • 장상태;이영재
    • Fire Science and Engineering
    • /
    • v.13 no.4
    • /
    • pp.13-19
    • /
    • 1999
  • Currently, conventional fire prevention facility installation standard is based on the use and size of the domestic theaters. In the study, theaters with 1,900 seats were examined to suggest a suitable method to adapt a better fire preventing system. The proposed systems are as follow. - 100% of backup pressed-water outlet device, considering waterproof pressure for fire prevention facility at the top floor. - The supplement of the side wall type header and a large caliber outlet header for stage open sprinkler. - Subdividing a installation rule for special detector and implementing the latestdetector. - Installation of fire curtain for dividing stage area and auditorium area, and also the method of installation of fire curtain.

  • PDF