• 제목/요약/키워드: Ultra-sensitive

검색결과 149건 처리시간 0.03초

이트리아($Y_2O_3$) 세라믹 래핑가공의 AE 신호 분석 (AE Signal Analysis of Yttria($Y_2O_3$) Ceramic Lapping Process)

  • 차지완;황성철;신태희;이은상
    • 한국생산제조학회지
    • /
    • 제19권1호
    • /
    • pp.7-14
    • /
    • 2010
  • AE(acoustic emission) sensor has been used for a state monitoring and observation during a ultra-precision machining because AE signal, which has high frequency range, is sensitive enough. In case of ceramic fabrication, a monitoring of machining state is important because of its hard and brittle nature. A machining characteristic of ceramic is susceptibly different in accordance with variable machining conditions. In this study, Yttria($Y_2O_3$) ceramic was fabricated using the ultra-precision lapping process with in-process electrolytic dressing(IED) method. And the surface machining characteristic and AE sensor signal were compared and analyzed.

화학적 성분 분석능력을 가진 원자 현미경의 제작 (A micromachined cantilever for chemically sensitive scanning force microscope applications)

  • 이동원
    • 센서학회지
    • /
    • 제14권1호
    • /
    • pp.1-6
    • /
    • 2005
  • This paper describes a novel concept of a chemically sensitive scanning force microscope (CS-SFM). It consists of the conventional SFM and the time-of-flight mass spectrometer (TOF-MS). A switchable cantilever (SC) fabricated by the micromachining technology combines each advantage of two completely different systems, SFM and TOF-MS. The CS-SFM offers to produce both images of topography and chemical information simultaneously. First we employed a rotatable tip holder based on 4 piezotube actuators for demonstration of the possibility of the CS-SFM concept. Second the CS-SFM concept is optimized with the micromachining technology. The micromachined SC with an integrated bimorph actuator and a piezoresistive strain sensor provides a reasonable switching speed of ${\sim}10$ ms which is very attractive for the CS-SFM application. The SC is currently being integrated in an ultra-high-vacuum system to perform various experiments.

Electrical and Optical Propeties of a UV-Sensitive CCD Imager

  • Kim, Man-Ho;Choi, Jae-Ha
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권4호
    • /
    • pp.518-524
    • /
    • 2007
  • This paper describes several improved characterizations of the EPIC CCD, which now has modified electrode and channel structures. From a 3-D numerical simulation of the device, its channel doping and potential distributions are then observed for the optimization of the charge transfer. A wavelength-dependence on the device structure is observed in terms of the reflectivity of the incident radiation. The optical properties of ultra-low energy levels, when using an open-electrode structure, are then considered to improve their quantum efficiency.

Development of charge sensitive amplifiers based on various circuit board substrates and evaluation of radiation hardness characteristics

  • Jeong, Manhee;Kim, Geehyun
    • Nuclear Engineering and Technology
    • /
    • 제52권7호
    • /
    • pp.1503-1510
    • /
    • 2020
  • Ultra-low noise charge sensitive amplifiers (CSAs) based on various types of circuit board substrates, such as FR4, Teflon, and ceramics (Al2O3) with two different designs, PA1 and PA2, have been developed. They were tested to see the noise effect from the dielectric loss of the substrate capacitance before and after irradiation. If the electronic noise from the CSAs is to be minimized and the energy resolution enhanced, the shaping time has to be optimized for the detector, and a small feedback capacitance of the CSA is favorable for a better SNR. Teflon- and ceramic-based PA1 design CSAs showed better noise performance than the FR4-based one, but the Teflon-based PA1 design showed better sensitivity than ceramic based one at a low detector capacitance (<10 pF). In the PA2 design, the equivalent noise and the sensitivity were 0.52 keV FWHM for a silicon detector and 7.2 mV/fC, respectively, with 2 ㎲ peaking time and 0.1 pF detector capacitance. After 10, 100, 103, 104, and 105 Gy irradiation the ENC and sensitivity characteristics of the developed CSAs based on three different substrate materials are also discussed.

UHF 대역 RFID 시스템용 고감도 광대역 태그 안테나의 설계 (Design of High Sensitive Broadband Tag Antenna for RFID System in UHF Band)

  • 박건도;민경식
    • 한국항해항만학회지
    • /
    • 제33권1호
    • /
    • pp.51-56
    • /
    • 2009
  • 본 논문은 UHF 대역 RFID 시스템용 고감도 광대역 태그 안테나의 설계에 대하여 기술한다. 제안된 태그 안테나의 크기는 $60\;mm\;{\times}\;10\;mm\;{\times}\;1\;mm$이다. 공진 주파수는 910 MHz 이고, - 10 dB이하 대역폭은 약 900 MHz이다. 측정된 반사손실과 지향성 패턴은 계산결과 잘 일치하는 것으로 확인되었다. 칩을 가진 제안한 태그 안테나의 인식거리는 6.5 m로 관측되었으며, 이 값은 상용 태그 안테나의 인식거리보다 평균 0.5 m이상 멀리 감지된 결과이다.

Sensitive determination of pendimethalin and dinoseb in environmental water by ultra performance liquid chromatography-tandem mass spectrometry

  • Lim, Hyun-Hee;Park, Tae-Jin;Lee, Soo-Hyung;Shin, Ho-Sang
    • 분석과학
    • /
    • 제30권4호
    • /
    • pp.194-204
    • /
    • 2017
  • Direct injection (DI) and solid phase extraction (SPE) methods for the simultaneous determination of pendimethalin (PDM) and dinoseb (DNS) in environmental water have been optimized using the ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method. The limits of quantification (LOQs) of PDM and DNS were $0.01{\mu}g/L$ using the DI method and $0.0001-0.0002{\mu}g/L$ using the SPE method. The precision by SPE UPLC-MS/MS was less than 11 % for intra-day and inter-day analyses. When the proposed SPE method was used to analyze two analytes in environmental water, PDM was detected in a concentration range of $0.0002-0.011{\mu}g/L$ in 31 samples of the 114 surface water samples, and DNS was detected in a concentration range of $0.0005-0.045{\mu}g/L$ in 17 samples of the 114 surface water samples analyzed. When the DI method was used to analyze target compounds in the same samples, the detected concentrations of the two analytes were within 21% in samples with concentrations above $0.01{\mu}g/L$. The DI UPLC-MS/MS method can thus be used for the routine monitoring of PDM and DNS in environmental water, and the SPE LC-MS/MS method can be used for the determination of the ultra-trace PDM and DNS residues in environmental water.

UHPLC를 이용한 식품 중의 PAHs 신속분석법 (The rapid determination of PAHs in foods using ultra high performance liquid chromatography)

  • 하재호;신동빈;황진봉;서혜영;이토 마사히토;나카가와 히오아키
    • 분석과학
    • /
    • 제24권4호
    • /
    • pp.266-274
    • /
    • 2011
  • Hitachi LaChromUltra 2000U를 사용하여 역상의 초고속액체크로마토그래피 방법으로 식품 중의 PAHs 14종을 신속하게 분석하는 방법을 개발하였다. PAHs분석을 위한 방법은 solid phase extraction (SPE)법에 의한 정제 후 u-HPLC를 사용하여 형광검출기로 분석하였다. 이 분석법은 감도가 매우 좋았으며, 식품 중의 PAHs를 ${\mu}g$/kg수준에서 분석이 가능하였다. 6개의 시료를 분석한 결과 모든 시료에서 PHE가 검출되었고, 그 함량은 2.5~19.9 ${\mu}g$/kg이었다. Benzo[c]fluorine (BCL), pyrene (PYR), benzo[a]anthracene (BaA), chrysene (CHR), benzo[b]fluoranthene (BbF), benzo[k]fluoranthene (BkF) 이 ${\mu}g$/kg이하의 농도에서 검출되었으나 그 농도는 모두 정량한계 이하이었다.

저가형 PSD센서를 이용한 홈서비스 로봇의 Map building용 센서 제어시스템 (A sensor controller for map building of home service robot using low cost PSD sensor)

  • 현웅근;이창환
    • 한국정보통신학회논문지
    • /
    • 제10권10호
    • /
    • pp.1897-1904
    • /
    • 2006
  • 가사도우미 로봇과 같은 서비스 로봇은 가사구성물이 내제된 가정 내 가사 구성물 환경을 인식해야한다. 기존에는 홈서비스 로봇 등은 CCD, 초음파 등의 센서로 가정 내 구성물 및 실내 지형을 인식하였다. 실내지형 지도를 작성 할 경우 가사 구성물에는 헝겊 등이 있는바, 음파 등을 흡수하여 정확한 지형 지도가 만들어지지 못한다. 또한 CCD 카메라를 쓸 경우 pixel에 따라 거리 측정 정도가 달라지는 문제가 발생하고 가격이 고가이다. 본 논문은 이동로봇을 위한 위치 및 물체인식용 지능형 센서 제어 시스템에 대해 기술한다. 개발된 센서제어시스템은 저가의 광 PSD(Position sensitive detector)를 사용하였다. PSD센서의 스위칭 노이즈 및 광 산란에 의한 잡음을 효과적으로 제거하기 위해 로봇의 주행 중 센서 스캔 시 간 등을 고려하여 heuristic software filter를 제안하였다. 또한 개발된 시스템은 초음파 센서에 의한 지형작성 비교와 본 논문에서 개발한 시스템을 비교하였으며, 복잡한 실내지 형을 대상으로 실험 지형지도 작성 실험을 통해 우수성을 입증하였다.

초고속 Real-time PCR을 이용한 Tomato yellow leaf curl virus의 신속진단 (Ultra-rapid Real-time PCR for the Detection of Tomato yellow leaf curl virus)

  • 김택수;최승국;고민정;이민호;최형석;이세원;박경석;박진우
    • 식물병연구
    • /
    • 제18권4호
    • /
    • pp.298-303
    • /
    • 2012
  • 토마토황화잎말림바이러스(Tomato yellow leaf curl virus; TYLCV)는 온실가루이(Bemisia tabaci)에 의해서 영속전염되는 DNA 바이러스로 토마토에 발생하는 가장 중요한 병 중 하나이다. 우리나라에서 TYLCV는 2008년 최초로 보고된 이래 급속하게 전국적으로 확산되어 토마토 생산에 심각한 경제적 손실을 일으키고 있다. 토마토 생산과정에서 TYLCV의 확산을 최소화하기 위해 바이러스의 조기진단이 매우 중요하다. 본 연구에서는 바이러스의 신속진단을 위해 초고속 정밀 PCR 진단기술을 개발하였으며, 이는 마이크로칩을 기반으로 하여 $5{\mu}l$의 시료만으로 PCR을 수행할 수 있도록 고안된, 휴대가 가능할 정도의 소형 GenSpector$^{TM}$ TMC-1000 PCR 기기를 이용한 새로운 기술이다. 본 연구에서 개발된 초고속 정량 PCR을 이용하였을 때 TYLCV 진단을 위한 30 cycle의 PCR과 용융점분석(melting curve analysis)에 15분 이내의 시간이 소요되었으며, GenSpector$^{TM}$ TMC-1000 PCR을 이용한 초고속 정밀진단 기술은 향후 TYLCV의 대발생을 모니터링하는데 유용하게 사용될 수 있을 것으로 생각한다. 본 연구결과는 GenSpector$^{TM}$ TMC-1000 PCR기반의 초고속정량 PCR 기술을 이용한 식물 바이러스의 진단기술 개발로는 최초의 보고이다.

Nanoplasmonics: Enabling Platform for Integrated Photonics and Sensing

  • Yeo, Jong-Souk
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.75-75
    • /
    • 2015
  • Strong interactions between electromagnetic radiation and electrons at metallic interfaces or in metallic nanostructures lead to resonant oscillations called surface plasmon resonance with fascinating properties: light confinement in subwavelength dimensions and enhancement of optical near fields, just to name a few [1,2]. By utilizing the properties enabled by geometry dependent localization of surface plasmons, metal photonics or plasmonics offers a promise of enabling novel photonic components and systems for integrated photonics or sensing applications [3-5]. The versatility of the nanoplasmonic platform is described in this talk on three folds: our findings on an enhanced ultracompact photodetector based on nanoridge plasmonics for photonic integrated circuit applications [3], a colorimetric sensing of miRNA based on a nanoplasmonic core-satellite assembly for label-free and on-chip sensing applications [4], and a controlled fabrication of plasmonic nanostructures on a flexible substrate based on a transfer printing process for ultra-sensitive and noise free flexible bio-sensing applications [5]. For integrated photonics, nanoplasmonics offers interesting opportunities providing the material and dimensional compatibility with ultra-small silicon electronics and the integrative functionality using hybrid photonic and electronic nanostructures. For sensing applications, remarkable changes in scattering colors stemming from a plasmonic coupling effect of gold nanoplasmonic particles have been utilized to demonstrate a detection of microRNAs at the femtomolar level with selectivity. As top-down or bottom-up fabrication of such nanoscale structures is limited to more conventional substrates, we have approached the controlled fabrication of highly ordered nanostructures using a transfer printing of pre-functionalized nanodisks on flexible substrates for more enabling applications of nanoplasmonics.

  • PDF