• 제목/요약/키워드: Type of mode III

검색결과 40건 처리시간 0.029초

TELM에 적용한 직병렬 공진형 DC/DC 컨버터의 출력전압 제어에 관한 연구 (A Study on the Output Voltage Control of Series-Parallel Resonant type DC/DC Converter for Transverse Flux Linear Motor)

  • 황계호;이영식;전진용;방덕제;김호종;신병철;강도현;김종무
    • 반도체디스플레이기술학회지
    • /
    • 제4권1호
    • /
    • pp.9-16
    • /
    • 2005
  • In this paper, with loosely coupled transformer Relies-parallel resonant type DC/DC converter is analyzed and adopted to the power source of a TFLM(Transverse Flux Linear Motor). To get more efficient operating mode of the series-parallel resonant type DC/DC converter, theoretical analysis using normalized parameters are accepted. The analysis includes a specially made ferrite transformer with two separately wound half cores in order to evaluate analytically and experimentally the changes in magnetizing the leakage fluxes and inductances caused by the distance between the halves. The proposed converter must be operated in switching Pattern III among the three switching patterns for the Zero Voltage Switching operation. According to Pulse Frequency Modulation(PFM) control method, the output voltage of the proposed circuit can be controlled. The results of the theoretical development are compared with practical measurements from a prototype system.

  • PDF

Stimulated Emission with 349-nm Wavelength in GaN/AlGaN MQWs by Optical Pumping

  • Kim, Sung-Bock;Bae, Sung-Bum;Ko, Young-Ho;Kim, Dong Churl;Nam, Eun-Soo
    • Applied Science and Convergence Technology
    • /
    • 제26권4호
    • /
    • pp.79-85
    • /
    • 2017
  • The crack-free AlGaN template has been successfully grown by using selective area growth with triangular GaN facet. The triangular GaN stripe structure was obtained by vertical growth rate enhanced mode with low growth temperature of $950^{\circ}C$ and high growth pressure of 500 torr. The lateral growth rate enhanced mode of AlGaN for crack-free and flat surface was also investigated. Low pressure of 30 torr and high V/III ratio of 4400 were favorable for lateral growth of AlGaN. It was confirmed that the $4{\mu}m$ -thick $Al_{0.2}Ga_{0.8}N$ was crack-free over entire 2-inch wafer. The dislocation density of $Al_{0.2}Ga_{0.8}N$ was as low as ${\sim}7.6{\times}10^8/cm^2$ measured by cathodoluminescence. Based on the high quality AlGaN with low dislocation density, the ultraviolet laser diode epitaxy with cladding, waveguide and GaN/AlGaN multiple quantum well (MQW) was grown by metalorganic chemical vapor deposition. The stimulated emission at 349 nm with full width at half maximum of 1.8 nm from the MQW was observed through optical pumping experiment with 193 nm KrF laser. We also have fabricated the deep ridge type ultraviolet laser diode (UV-LD) with $5{\mu}m-wide$ and $700{\mu}m-long$ cavity for electrical properties. The turn on voltage was below 5 V and the resistance was ${\sim}55{\Omega}$ at applied voltage of 10 V. The amplified spontaneous emission spectrum of UV-LD was also observed from pulsed current injection.

찢김 하중에서 단일 재료 및 이종 접합 재료에 따른 이중외팔보 시험편의 접착제 파손 특성 (Adhesive Fracture Characteristic of DCB Specimen due to Single and Heterogeneous Materials under Tearing Load)

  • 김재원;조재웅
    • 한국기계가공학회지
    • /
    • 제20권4호
    • /
    • pp.127-134
    • /
    • 2021
  • In this study, the adhesive fracturing characteristics of a DCB specimen due to single and heterogeneous bonding materials under tearing load was investigated. The experiments were conducted to examine the fracturing properties of the adhesive DCB specimen. As an experimental condition, a forced displacement of 3mm/min was applied to one side while the other side was fixed. As a result of the experiment, it was found that the AL6061-T6 material was superior to the CFRP material in terms of maximum stress, specific strength, and energy release rate when compared to the adhesive fracturing property of a single material. We tested CFRP-AL, a heterogeneous bonding material, and compared its experimental results to the results from the single materials. Based on these results, CFRP-AL with a heterogeneous bonding material was observed to have the superior structural safety compared to single materials for the mode III fracture type.

반복하중에 따른 수종 임플란트의 피로파절에 관한 연구 (Fatigue fracture of different dental implant system under cyclic loading)

  • 박원주;조인호
    • 대한치과보철학회지
    • /
    • 제47권4호
    • /
    • pp.424-434
    • /
    • 2009
  • 연구목적: 임플란트는 수직교합 하중에는 비교적 잘 견디나 측방하중에 대해서는 약한 역학적 성질을 갖고 있으므로 임플란트의 재료 특성과 기하학적 형태에 따른 응력 분석 연구의 필요성이 제기되고 있다. 연구재료 및 방법: 외부육각구조를 갖는 28개의 임플란트를 7개씩 4군으로 나누어 그 제품에 적합한 UCLA gold abutment를 이용해, 제3형 금합금으로 보철 물을 제작하였고, A군 (3i, FULL $OSSEOTITE^{(R)}$-Implant), B군 (Nobelbiocare, Branemark $System^{(R)}$Mk III Groovy RP), C군 (Neobiotec, $SinusQuick^{(TM)}$ EB), D군 (Osstem, US-II)으로 분류하였다. 고정체와 지대주나사, 지대주를 연결한 후 수직적으로 절단하여 연마한 후 미세경도계를 이용하여 10군데에서 경도측정을 실시하였고, 동적하중 피로시험기를 이용하여 60-600 N범위로 파절시까지 동적 하중을 가하였다. 주사전자현미경을 이용하여 지대주나사 및 고정체의 파절 양상과 파절 위치 등을 관찰하였고, 유한요소분석을 통해 고정체와 지대주 나사에 나타나는 응력 분포와 파절면을 비교 분석하였다. 결과: 1.고정체 경도는 A, B, C, D군에서 각각 245.3, 289.7, 281.3, 300.4 Hv로 D군이 가장 높았고, A군이 가장 낮았다. 지대주 나사의 경도는 A, B, C, D군에서 각각 340.00, 317.62, 306.5, 306.2 Hv로 A군이 가장 높고, D군이 가장 낮았다. 2. 모든 실험군에서 임플란트 고정체의 파절은 응력이 집중되는 고정체 3-4번째 나사산 홈 (valley) 부위 또는 내면의 사공간부와 일치하는 부위에서 발생되었고, 피로수명은 A, B, C, D군에서 각각 31585, 47311, 30141, 105371로 D군이 가장 높았으며, A, B, C군과는 유의한 차이가 있었다(P<.05). 3. 파절양상은 B군과D군에서는 고정체와 나사 모두에서 수직 (longitudinal)파절과 수평 (transverse)파절이 동시에 일어나는 복합 (complex mode) 파절이 관찰 되었고, A와 C군에서는 고정체에서 수평 (transverse mode) 파절만이 관찰되었다. 4. 유한요소분석 결과 인장응력이 가장 높은 고정체 표면부에서 피로 균열이 시발되어 압축응력이 가장 높은 반대편 부위로 피로균열이 전파되었으며, 최대 유효 응력값은 C군이 가장 높았고, B군에서 가장 낮았다. 결론: 피질골 높이와 일치하는 임플란트 고정체 부위에서 최대 인장 주응력이 발생되며, 고정체 사공간부 (dead space)가 최대 인장 주응력이 작용하는 지그 표면과 일치할 때 피로파절이 발생되었다. 따라서 악골에 식립된 임플란트의 신뢰성을 향상시키고 수명을 증대시키기 위해서는 가능한 임플란트 주위의 골소실이 일어나지 않도록 해야 할 것이나 골흡수가 일어나 사공간부 수준까지 진행된다면 임플란트의 파절 빈도가 증가될 수 있으므로 이에 대한 대처가 필요할 것으로 사료된다.

상아질 형성 부전증에 대한 증례보고 (A CASE REPORT OF DENTINOGENESIS IMPERFECTA)

  • 김재곤;이두철;이승영;이승익;백병주
    • 대한소아치과학회지
    • /
    • 제27권1호
    • /
    • pp.1-6
    • /
    • 2000
  • 상아질 형성 부전증은 상아질 형성에 이상을 초래하는 유전성 질환으로, 주로 상염색체 우성의 양상으로 유전된다. 제1형의 상아질 형성 부전증은 골 형성 부전증 환자에서 나타난다. 제2형 상아질 형성 부전증은 골 형성 부전증과 연관되지 않고 단독으로 나타난다. 제3형 상아질 형성 부전증은 brandywine type이라고도 하는데, 이 유형은 매우 드물며 상염색체 우성에 의해 유전되고, Maryland 주에 사는 한정된 민족에서 관찰된다. 세가지 모든 유형에서 유치열과 영구치열 모두 다양한 임상 양상을 나타낸다. 치아는 유백색을 띠고, 청회색에서 황갈색까지 다양하게 변색되어 있다. 상아질은 비정상적으로 연하고, 상부의 법랑질을 기능적으로 지지하지 못한다. 비록 법랑질이 정상이고 해도, 쉽게 파절되어 떨어져나가, 교합면이나 절단면쪽 상아질이 노출된다. 노출된 유약 상아질은 쉽고, 빠르게 심한 교모를 일으킨다. 치아는 구형의 치관과 협소화된 백악-법랑 경계 그리고 가는 치근을 나타낸다. 치수강과 치근관은 다양한 정도의 폐쇄상을 나타낸다. 백악질, 치주인대, 그리고 치조골은 정상 소견을 나타낸다. 상아질 형성 부전증에서 법랑질은 정상이다. 법랑질은 직하방의 mantle dentin은 거의 정상적이나, 나머지 상아질은 심각한 정도의 이형성을 나타낸다. 상아세관은 방향성을 상실하여 불규칙적이며, 정상보다 더 크고 공간도 넓다.

  • PDF

COMPARATIVE STUDY ON THE FRACTURE STRENGTH OF METAL-CERAMIC VERSUS COMPOSITE RESIN-VENEERED METAL CROWNS IN CEMENT-RETAINED IMPLANT-SUPPORTED CROWNS UNDER VERTICAL COMPRESSIVE LOAD

  • Pae, Ahran;Jeon, Kyung-A;Kim, Myung-Rae;Kim, Sung-Hun
    • 대한치과보철학회지
    • /
    • 제45권3호
    • /
    • pp.295-302
    • /
    • 2007
  • Statement of problem. Fracture of the tooth-colored superstructure material is one of the main prosthetic complications in implant-supported prostheses. Purpose. The purpose of this in vitro study was to compare the fracture strength between the cement-retained implant-supported metal-ceramic crowns and the indirect composite resinveneered metal crowns under the vertical compressive load. Material and methods. Standard implants of external type (AVANA IFR 415 Pre-mount; Osstem Co., Busan, Korea) were embedded in stainless steel blocks perpendicular to their long axis. Customized abutments were fabricated using plastic UCLA abutments (Esthetic plastic cylinder; Osstem Co., Busan, Korea). Thirty standardized copings were cast with non-precious metal (Rexillium III, Pentron, Walling ford, Conn., USA). Copings were divided into two groups of 15 specimens each (n = 15). For Group I specimens, metal-ceramic crowns were fabricated. For Group II specimens, composite resin-veneered (Sinfony, 3M-ESPE, St. Paul, MN, USA) metal crowns (Sinfony-veneered crowns) were fabricated according to manufacturer's instructions. All crowns were temporary cemented and vertically loaded with an Instron universal testing machine (Instron 3366, Instron Corp., Norwood, MA, USA). The maximum load value (N) at the moment of complete failure was recorded and all data were statistically analyzed by independent sample t-test at the significance level of 0.05. The modes of failure were also investigated with visual analysis. Results. The fracture strength of Sinfony-veneered crowns ($2292.7{\pm}576.0N$) was significantly greater than that of metal-ceramic crowns ($1150.6{\pm}268.2N$) (P < 0.05). With regard to the failure mode, Sinfony-veneered crowns exhibited adhesive failure, while metal-ceramic crowns tended to fracture in a manner that resulted in combined failure. Conclusion. Sinfony-veneered crowns demonstrated a significantly higher fracture strength than that of metal-ceramic crowns in cement-retained implant-supported prostheses.

대사증후군의 체질병증 모델 구축을 위한 예비연구 - 40대 태음인을 중심으로 - (A Pilot Study for the Construction of Sasang - Constitutionally Differentiated Model of the Metabolic Syndrome with Focus on 40 $\sim$ 49 year old Taeumin)

  • 김윤희;이준희;이의주;고병희
    • 사상체질의학회지
    • /
    • 제21권2호
    • /
    • pp.123-136
    • /
    • 2009
  • 1. Objectives : This study is a pilot study to construct of metabolic syndrome model with constitutional type. We focused on the correlation of Metabolic syndrome(MetS) and ordinary symptoms with Taeumin at 40. 2. Methods : 32 subjects who had taken health examinations and diagnosis of Sasang constitution from Oct 1, 2008 to Dec 31, 2008 at Kyung-Hee medical center were included and underwent B-mode ultrasonography for measurement of intima-media thickness of common carotid arteries. MetS was defined by the criteria of the criteria of the National Cholesterol Education Program Adult Treatment Panel III. 3. Results and Conclusions : Mean intima-media thickness of common carotid artery was higher in subjects with MetS compared with control subjects(0.56$\pm$0.12 vs 0.54$\pm$0.08mm) however. The ordinary symptoms shown to differentiate the MetS group and the control group were related to "dark urine color," "dryness of eyes," and "night sweat". Therefore, these ordinary symptoms can be said to be indicators of the Taeumin with Mets syndrome.

  • PDF

The Role of $K^+$ Channels on Spontaneous Action Potential in Rat Clonal Pituitary $GH_3$ Cell Line

  • Rhim, Hye-Whon;Baek, Hye-Jung;Ho, Won-Kyung;Earm, Yung-E
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제4권2호
    • /
    • pp.81-90
    • /
    • 2000
  • The types of $K^+$ channel which determine the pattern of spontaneous action potential (SAP) were investigated using whole-cell variation of patch clamp techniques under current- and voltage-clamp recording conditions in rat clonal pituitary $GH_3$ cells. Heterogeneous pattern of SAP activities was changed into more regular mode with elongation of activity duration and afterhyperpolarization by treatment of TEA (10 mM). Under this condition, exposure of the class III antiarrhythmic agent E-4031 $(5\;{\mu}M)$ to $GH_3$ cells hardly affected SAP activities. On the other hand, the main $GH_3$ stimulator thyrotropin-releasing hormone (TRH) still produced its dual effects (transient hyperpolarization and later increase in SAP frequency) in the presence of TEA. However, addition of $BaCl_2$ (2 mM) in the presence of TEA completely blocked SAP repolarization process and produced membrane depolarization in all tested cells. This effect was observed even in TEA-untreated cells and was not mimicked by higher concentration of TEA (30 mM). Also this barium-induced membrane depolarization effect was still observed after L-type $Ca^{2+}$ channel was blocked by nicardipine $(10\;{\mu}M).$ These results suggest that barium-sensitive current is important in SAP repolarization process and barium itself may have some depolarizing effect in $GH_3$ cells.

  • PDF

InAs/InGaAs 양자점을 이용한 전계광학변조기 (Electrooptic Modulator with InAs Quantum Dots)

  • 옥성해;문연태;최영완;손창완;이석;우덕하;변영태;전영민;김선호;이종창;오재응
    • 한국광학회지
    • /
    • 제17권3호
    • /
    • pp.278-284
    • /
    • 2006
  • 본 연구에서는 광통신 시스템에서의 고속변조를 위하여 사용되는 전계광학 변조기를 구현하기 위하여 InAs 양자점(Quantum Dots)을 변조영역으로 하는 전계광학 변조기를 설계, 제작하였다. 제작한 양자점 전계광학 변조기에서 1550 nm의 파장을 가지는 입력광의 변조 특성을 측정하여 벌크(Bulk)형태의 변조영역을 가지는 동일한 구조의 전계광학 변조기와 비교하였다. 위상변조효율은 TE 모드에서 $333.3^{\circ}/V{\cdot}mm$, TM 모드에서 $300^{\circ}/V{\cdot}mm$ 로 측정되었으며, 기존의 벌크로 변조영역이 구성된 전계광학 변조기와 동일한 소자구조를 가지는 전계광학 변조기에 비해 편광의존도가 낮으며 위상변조효율이 20배 이상 향상된 결과를 얻었으며, 양자우물구조에 비하여는 3배 이상의 높은 위상변조효율을 얻었다.

열순환이 상아질 접착제의 결합 내구성에 미치는 영향 (THE EFFECT OF THERMOCYCLING ON THE DURABILITY OF DENTIN ADHESIVE SYSTEMS)

  • 문영훈;김종률;최경규;박상진
    • Restorative Dentistry and Endodontics
    • /
    • 제32권3호
    • /
    • pp.222-235
    • /
    • 2007
  • 이 논문의 목적은 열순환이 4종 상아질 접착 시스템의 결합 내구성에 미치는 영향을 측정한 것이다. 제3대구치의 상아질층을 노출시킨 후, 무작위로 8개군으로 나눈다: 3단계 산부식 시스템 (Scotchbond Multi-Purpose Plus; SM, All Bond-2 ; AB), 2 단계 산부식 시스템 (Single Bond; SB, One Step plus, OS), 2단계 자가부식 시스템 (Clearfil SE Bond; SE, AdheSE; AD), 1 단계 자가부식 시스템 (Promp L-Pop ; PL, Xeno III; XE). 8개 군에 각 상아질 접착제를 제조사의 지시에 따라 도포하고 복합레진 (Z250)을 적층한 후, 광조사한다. $37^{\circ}C$ 증류수에서 24시간 보관한 후, 각 군마다 정해진 프로그램으로 0, 1000, 2000회 열순환한 후, 저속 diamond saw로 $1\times1mm$ 막대형 시편을 제작한다. Universal testing machine (EZ-test; Shimadzu, Japan)으로 미세인장 결합강도를 측정하였고, 유의수준 0.05 level에서 ANOVA / Duncan's test로 통계분석 하였다. 상아질측 파단면과 접착계면에 대한 주사전자현미경 관찰을 시행하였다. 이 연구의 결과는 다음과 같다; 1. 3단계 상아질 접착제의 결합강도는 열순환 전후에 통계학적으로 유의한 변화를 나타내지 않았다. 2단계 산부식형 상아질 접착제의 결합강도는 열순환 처리에 의하여 유의하게 감소되었다. 2. 2단계 자가부식형 접착제 (SE)의 결합강도가 가장 높았고, 1단계 자가부식 접착제 (PL, XE)는 실험군 중 가장 낮은 결합강도를 보였다. 3. 모든 접착제는 주로 접착성 파괴가 발생하였고, 열순환에 의하여 산부식형 접착제는 접착성 파괴가, 1단계 자가부식형 접착제에서는 혼합형 파괴가 증가하는 경향을 나타내었다. 이상의 결과로, 상아질 접착제의 접착단계/과정이 결합내구성에 영향을 미침을 알 수 있었다. 따라서 접착과정의 단순화가 반드시 접착에 효과적이라고 할 수 없다.