Fatigue fracture of different dental implant system under cyclic loading  

Park, Won-Ju (Department of Prosthodontics, College of Dentistry, Dankook University)
Cho, In-Ho (Department of Prosthodontics, College of Dentistry, Dankook University)
Publication Information
The Journal of Korean Academy of Prosthodontics / v.47, no.4, 2009 , pp. 424-434 More about this Journal
Abstract
Statement of problem: Problems such as loosening and fractures of retained screws and fracture of implant fixture have been frequently reported in implant prosthesis. Purpose: Implant has weak mechanical properties against lateral loading compared to vertical occlusal loading, and therefore, stress analysis of implant fixture depending on its material and geometric features is needed. Material and methods: Total 28 of external hexed implants were divided into 7 of 4 groups; Group A (3i, FULL $OSSEOTITE^{(R)}$Implant), Group B (Nobelbiocare, $Br{\aa}nemark$ $System^{(R)}$Mk III Groovy RP), Group C (Neobiotec, $SinusQuick^{TM}$ EB), Group D (Osstem, US-II). The type III gold alloy prostheses were fabricated using adequate UCLA gold abutments. Fixture, abutment screw, and abutment were connected and cross-sectioned vertically. Hardness test was conducted using MXT-$\alpha$. For fatigue fracture test, with MTS 810, the specimens were loaded to the extent of 60-600 N until fracture occurred. The fracture pattern of abutment screw and fixture was observed under scanning electron microscope. A comparative study of stress distribution and fracture area of abutment screw and fixture was carried out through finite element analysis Results: 1. In Vicker's hardness test of abutment screw, the highest value was measured in group A and lowest value was measured in group D. 2. In all implant groups, implant fixture fractures occurred mainly at the 3-4th fixture thread valley where tensile stress was concentrated. When the fatigue life was compared, significant difference was found between the group A, B, C and D (P<.05). 3. The fracture patterns of group B and group D showed complex failure type, a fracture behavior including transverse and longitudinal failure patterns in both fixture and abutment screw. In Group A and C, however, the transverse failure of fixture was only observed. 4. The finite element analysis infers that a fatigue crack started at the fixture surface. Conclusion: The maximum tensile stress was found in the implant fixture at the level of cortical bone. The fatigue fracture occurred when the dead space of implant fixture coincides with jig surface where the maximum tensile stress was generated. To increase implant durability, prevention of surrounding bone resorption is important. However, if the bone resorption progresses to the level of dead space, the frequency of implant fracture would increase. Thus, proper management is needed.
Keywords
Implant; hardness; Cyclic loading; Fatigue fracture; Finite element analysis;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Hoyer SA, Stanford CM, Buranadham S, Fridrich T, Wagner J, Gratton D. Dynamic fatigue properties of the dental implant-abutment interface: joint opening in widediameter versus standard-diameter hex-type implants. J Prosthet Dent 2001;85:599-607   DOI   ScienceOn
2 Boggan RS, Strong JT, Misch CE, Bidez MW. Influence of hex geometry and prosthetic table width on static and fatigue strength of dental implants. J Prosthet Dent 1999;82:436-40   DOI   ScienceOn
3 Adell R, Lekholm U, Rockler B, Bra?.?.nemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981;10:387-416   DOI   PUBMED
4 Balshi TJ. An analysis and management of fractured implants: a clinical report. Int J Oral Maxillofac Implants 1996;11:660-6   PUBMED   ScienceOn
5 Adell R, Eriksson B, Lekholm U, Br$\aa$nemark PI, Jemt T. Long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws. Int J Oral Maxillofac Implants 1990;5:347-59   PUBMED
6 Eckert SE, Wollan PC. Retrospective review of 1170 endosseous implants placed in partially edentulous jaws. J Prosthet Dent 1998;79:415-21   DOI   ScienceOn
7 Tagger Green N, Machtei EE, Horwitz J, Peled M. Fracture of dental implants: literature review and report of a case. Implant Dent 2002;11:137-43   DOI   ScienceOn
8 Bonakdarchian M, Askari N, Askari M. Effect of face form on maximal molar bite force with natural dentition. Arch Oral Biol 2009;54:201-4   DOI   ScienceOn
9 Linkow LI, Donath K, Lemons JE. Retrieval analyses of a blade implant after 231 months of clinical function. Implant Dent 1992;1:37-43   PUBMED   ScienceOn
10 Gargallo Albiol J, Satorres-Nieto M, Puyuelo Capablo JL, Sa、nchez Garce、s MA, Pi Urgell J, Gay Escoda C. Endosseous dental implant fractures: an analysis of 21 cases. Med Oral Patol Oral Cir Bucal 2008;13:E124-8   PUBMED
11 Parein AM, Eckert SE, Wollan PC, Keller EE. Implant reconstruction in the posterior mandible: a long-term retrospective study. J Prosthet Dent 1997;78:34-42   DOI   ScienceOn
12 Vallittu PK. Effect of 180-week water storage on the flexural properties of E-glass and silica fiber acrylic resin composite. Int J Prosthodont 2000;13:334-9   PUBMED   ScienceOn
13 Binon PP, McHugh MJ. The effect of eliminating implant/abutment rotational misfit on screw joint stability. Int J Prosthodont 1996;9:511-9   PUBMED   ScienceOn
14 Jemt T, Linde、n B, Lekholm U. Failures and complications in 127 consecutively placed fixed partial prostheses supported by Br$\aa$nemark implants: from prosthetic treatment to first annual checkup. Int J Oral Maxillofac Implants 1992;7:40-4   PUBMED
15 Takeshita F, Suetsugu T, Higuchi Y, Oishi M. Histologic study of failed hollow implants. Int J Oral Maxillofac Implants 1996;11:245-50   PUBMED
16 Tolman DE, Laney WR. Tissue-integrated prosthesis complications. Int J Oral Maxillofac Implants 1992;7:477-84   PUBMED
17 Ashley ET, Covington LL, Bishop BG, Breault LG. Ailing and failing endosseous dental implants: a literature review. J Contemp Dent Pract 2003;4:35-50   PUBMED   ScienceOn
18 Bahat O, Handelsman M. Use of wide implants and double implants in the posterior jaw: a clinical report. Int J Oral Maxillofac Implants 1996;11:379-86   PUBMED   ScienceOn
19 Jemt T, Lekholm U. Oral implant treatment in posterior partially edentulous jaws: a 5-year follow-up report. Int J Oral Maxillofac Implants 1993;8:635-40   PUBMED   ScienceOn
20 Zarb GA, Schmitt A. The longitudinal clinical effectiveness of osseointegrated dental implants: the Toronto study. Part III: Problems and complications encountered. J Prosthet Dent 1990;64:185-94   DOI   ScienceOn
21 Rangert B, Jemt T, Jo ¨rneus L. Forces and moments on Branemark implants. Int J Oral Maxillofac Implants 1989;4:241-7   PUBMED
22 Kim JH, Lee JB. A comparative study on the correlation between Korean foods and the fractures of PFG and all ceramic crowns for posterior applications. J Korean Acad Prosthodont 2009;47:156-63   DOI   ScienceOn
23 Conrad HJ, Schulte JK, Vallee MC. Fractures related to occlusal overload with single posterior implants: a clinical report. J Prosthet Dent 2008;99:251-6   DOI   ScienceOn
24 Piattelli A, Piattelli M, Scarano A, Montesani L. Light and scanning electron microscopic report of four fractured implants. Int J Oral Maxillofac Implants 1998;13:561-4   PUBMED   ScienceOn
25 Carlson B, Carlsson GE. Prosthodontic complications in osseointegrated dental implant treatment. Int J Oral Maxillofac Implants 1994;9:90-4   PUBMED   ScienceOn
26 Kim JM, Han JS, Lee SY, Yang JH, Lee JB, Kim YS. A study of screw looswning after dynamic continous fatigue test of several abutment screw. J Korean Acad Prosthodont 2003:41:519-31   과학기술학회마을   ScienceOn
27 Lim TW, Cho IH, Lim JH, Lim HS. On the fatigue strength of dental implants with different types of connection between fixture and abutment cylinder. J Korean Acad Stomatognathic Func Occlusion 2002;18:1-19
28 Higuchi KW, Folmer T, Kultje C. Implant survival rates in partially edentulous patients: a 3-year prospective multicenter study. J Oral Maxillofac Surg 1995;53:264-8   DOI   ScienceOn
29 Rangert B, Krogh PH, Langer B, Van Roekel N. Bending overload and implant fracture: a retrospective clinical analysis. Int J Oral Maxillofac Implants 1995;10:326-34   PUBMED   ScienceOn
30 Mericske-Stern R, Steinlin Schaffner T, Marti P, Geering AH. Peri-implant mucosal aspects of ITI implants supporting overdentures. A five-year longitudinal study. Clin Oral Implants Res 1994;5:9-18   DOI   ScienceOn
31 Hong WS, Kim TH, Ryu SH, Kook MS, Park HJ, Oh HK. Comparative study of osseoi ntegration of 4 different surfaced implant in the tibia of dogs. J Korean Oral Maxillofac Surg 2005;31:46-54   과학기술학회마을   ScienceOn
32 Cibirka RM, Nelson SK, Lang BR, Rueggeberg FA. Examination of the implant-abutment interface after fatigue testing. J Prosthet Dent 2001;85:268-75   DOI   ScienceOn
33 Morgan MJ, James DF, Pilliar RM. Fractures of the fixture component of an osseointegrated implant. Int J Oral Maxillofac Implants 1993;8:409-14   PUBMED   ScienceOn
34 Han MJ, Chung CH, Choi HC. A study on surface alternation of implant screws after function. J Korean Acad Prosthodont 2002;40:275-86   ScienceOn
35 Santos MD, Pfeifer AB, Silva MR, Sendyk CL, Sendyk WR. Fracture of abutment screw supporting a cemented implant-retained prosthesis with external hexagon connection: a case report with sem evaluation. J Appl Oral Sci 2007;15:148-51   DOI   PUBMED
36 Siddiqui AA, Claudi R. Proceedings of the 4th International Symposium on Implant Dentistry: Focus on Esthetics. San Diego, California, January 27-29, 1994. Abstracts. J Prosthet Dent 1994;72:623-34   DOI   PUBMED   ScienceOn