• Title/Summary/Keyword: Type of Installation

Search Result 1,522, Processing Time 0.028 seconds

Design of LCD Backlight Unit Coupled with Micro Fresnel Lens Array (배열형 소형 프레넬 렌즈가 결합된 LCD 백라이트의 설계)

  • Jeong, Man-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.2
    • /
    • pp.1-7
    • /
    • 2006
  • A light guided plate coupled with the micro Fresnel lens array(MFTA) is designed to improve the efficiency of the LCD backlight unit. Blazed Frenel lens and binary multi-level Fresnel lens are adapted for the MFLA. This type of MFLA can replace the prism sheet and diffuser sheet which are used for the conventional type of the LCD backlight unit. The luminance and uniformity are calculated to verify the performance of the MFLA type LCD backlight unit.

A Basic Study on the Measurement Induced Voltages due to Lightning Discharges (뇌방전에 의한 유도전압의 측정에 대한 기초적 연구)

  • Lee, Bok-Hee;Cho, Sung-Chul;Eom, Ju-Hong;Lee, Woo-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.559-564
    • /
    • 2004
  • This paper deals with the device for measuring the time-varying magnetic fields and induced voltages caused by lightning discharges. The two magnetic field measuring systems were designed and made. One consists of the loop-type magnetic field sensor with the active integrator operated by a differential amplifier. The other consists of the loop-type magnetic field sensor and Labview software. The loop-type magnetic field sensor detects the time derivative of the magnetic field being measured, and the signal detected is integrated by the Labview software. As a consequence, from the calibration experiments, the frequency bandwidth of the full measuring system ranges from 400 [Hz] to 1 (MHz) and the response sensitivity are 0.98 (mV/nT) and 22 (mV/nT) for the magnetic field sensor of 2 turns and 6 turns, respectively. Also, the results obtained by the two measuring devices well agreed with each other.

  • PDF

A Study on Ion Wind Characteristics of Acceleration Type Multipoint Electrode (가속형 다침전극의 이온풍 특성 연구)

  • Kim, Jin-Gyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.5
    • /
    • pp.104-109
    • /
    • 2011
  • In this paper, after an acceleration typed ion wind generator which could format strong electric field in air was manufactured and installed, the effects of the electrode configuration and distance of acceleration type ion wind generator with triangle structure on the ion wind generation characteristics were investigated. As a result, the ion wind generator with curvature multipoint electrode could generate higher ion wind velocity and ion wind generation yield than others with multipoint electrode, curvature line electrode, line electrode structure. The ion wind generator with curvature multipoint electrode showed a peak ion wind velocity of 1.33[m/s] at 19.0[kV] and a ion wind generation yield of 0.12[m/Ws] at 15.0[kV].

Evaluation of Electricity Generation According to Installation Type of Photovoltaic System in Residential Buildings (주거용 건물 태양광발전시스템의 설치유형에 따른 발전성능 평가)

  • Kim, Deok-Sung;Kim, Beob-Jeon;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.2
    • /
    • pp.35-45
    • /
    • 2017
  • The types of installation of the photovoltaic system applied to domestic residential buildings are classified as follows: Mounted modules with air circulation, semi-integrated modules with air duct behind, integrated modules with fully insulated back. In order to study generation characteristics of PV system, we verified the validity of interpretation program based on long-term measurement data of demonstration house installed in BAPV form and also analyzed the generation characteristics and performance of each installation type. The results are as follows. First, the RMSE of amount of generation and simulation according to annual daily insolation of demonstration system located in Daejeon was 0.98kWh and the range of relative error of monthly power generation was -5.8 to 3.1. Second, the average annual PR of mounted modules was 82%, semi-integrated modules 76.1% and integrated modules 71.9%. This differences were attributed to temperature loss. Third, the range of operating temperature of annual hourly photovoltaic modules was -6.5 to $61.0^{\circ}C$ for mounted modules, $-6.0{\sim}73.9^{\circ}C$ for semi-integrated modules and -5.5 to $88.9^{\circ}C$ for integrated modules. The temperature loss of each installation type was -14.0 to 16.1%, -13.8 to 21.9%, and -13.6 to 28.5%, respectively.

A Study on Construction and its Application of Multichannel Type Spectroradiometer (Multichannel Type 분광방사측정 시스템의 제작 및 응용에 관한 연구)

  • 성연국;백운식
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.10 no.2
    • /
    • pp.54-62
    • /
    • 1996
  • A multichannel type spectroradiometer which can measure the optical characteristics of light sources was constructed. Our system can be used to measure the optical characteristics of light sources of which the wavelengths are ranging from ultraviolet to infrared(220nm~1100nm)in 16msec. The optical characteristics such as color coordinates, color rendering index, brightness, color difference, etc. was measured and analyzed.

  • PDF

Fault Current Limiting Characteristics of Series Connected Flux-Lock Type Superconducting Fault Current Limiters (직렬연결된 자속구속형 초전도 사고전류 제한기의 사고전류제한 특성)

  • Lim, Sung-Hun;Kim, Jae-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.197-199
    • /
    • 2007
  • To apply the flux-lock type SFCL into power system, its current and voltage ratings are required to increase. Especially, in case of series connection of SFCLs, the countermeasure for simultaneous quenches must be considered. The structure, which each flux-lock type SFCL unit was wound in series on the same iron core, can induce the simultaneous quench of superconducting elements. Through the fault current limiting experiment for the suggested structure, it was confirmed that the even voltage burden among the superconducting elements comprising SFCLs could be made.

  • PDF

Current Limiting Characteristics of a Flux-lock type SFCL with Secondary Windings Connected to the Superconducting elements in parallel (초전도 소자 병렬 연결에 따른 자속구속형 한류기의 전류제한 특성)

  • Park, Hyoung-Min;Cho, Yong-Sun;Choi, Hyo-Sang;Oh, Geum-Kon;Jung, Soo-Bok;Lim, Sung-Hun;Choi, Myong-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.229-230
    • /
    • 2007
  • We investigated the quench characteristics of a superconducting element, two superconducting elements in order to increase the current capacity of flux lock type SFCL. The flux-lock type SFCL consisted of the transformer with a primary winding and a secondary winding connected in parallel, and the superconducting element was connected with secondary winding in series. The applied voltage at that time was 160 ${\sqrt{3}}$. We found that the parallel connection between the superconducting elements increased the power capacity and let quench characteristics improve through their mutual linkage.

  • PDF

A Study on Boost Type Single-Phase Inverter System for Compensation of Voltage Sag (Voltage Sag 보상을 위한 승압형 단상 인버터 시스템에 관한 연구)

  • Seo, Young-Min;Lee, Seung-Yong;Hong, Soon-Chan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.11
    • /
    • pp.50-57
    • /
    • 2011
  • This paper proposes a boost type single-phase inverter system to compensate the voltage sag appeared on source side. The proposed system is composed of a boost converter, a PWM inverter, and a bypass diode. If the voltage sag has appeared in input voltage, the boost converter would be operated to compensate it in the proposed system. The boost converter would not be operated when the magnitude of input voltage is more than 0.9 pu. The output voltage is kept constant by a direct-quadrature frame controller in the inverter. A 300 W class boost type inverter system was simulated, and the validity of the proposed system was verified by carrying out experiments.

A Study on the Green Growth Effect with the Rotational and Up-and-Down type Streetlight (회전·승하강식 가로등주 활용을 통한 녹색성장 효과에 관한 연구)

  • Choi, Hyoung-Bum;Kim, Kyung-Chul;Oh, Sung-Hwan;Hwang, Young-Rok;Jung, Ji-Won;Park, Dong-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.2
    • /
    • pp.19-23
    • /
    • 2011
  • The current streetlight system have been tried various attempts. but during maintenance, it has caused the traffic congestion and many risk factors. In addition, maintenance costs are very expensive to manage and the local government have to establish countermeasures about the present condition. If neglected, it may cause a variety of social problems. so, there should be a measure to prevent problems. This rotational and up-and-down type streetlight can be a solution to these factors and it has been highlighted indirectly in terms of green growth because we have to take advantage of the value.

The Evaluation of Pullout Resistance and Installation Damage according to the Shape of Flexible Strip Reinforcement (신장형 띠형 보강재의 형상에 따른 인발저항 및 시공성능 평가 실험 연구)

  • Jeoung, Jaehyeung;Kim, Jaehong
    • The Journal of Engineering Geology
    • /
    • v.31 no.3
    • /
    • pp.321-332
    • /
    • 2021
  • Though development of reinforced earth wall is on the rise recently, safety verification for various methods remains behind which has caused the problems including collapse after installation. This study aims to evaluate the field applicability of the shape of flexible strip reinforcement according to pullout resistance test and field damage test. The test specimens were 3 shape of reinforcement, the typical flexible band reinforcement, developed luged band reinforcement, and band type reinforcement made by cutting geogrid. It was found that reinforcement of type have strengths and weaknesses, respectively. The best type of flexible strip reinforcements can be selected, if the conditions are considered with the installation conditions of the reinforcing earth retaining wall and the particle size of the backfill materials.