• 제목/요약/키워드: Type IV stone

검색결과 35건 처리시간 0.022초

Evaluation of marginal and internal gap of three-unit metal framework according to subtractive manufacturing and additive manufacturing of CAD/CAM systems

  • Kim, Dong-Yeon;Kim, Eo-Bin;Kim, Hae-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권6호
    • /
    • pp.463-469
    • /
    • 2017
  • PURPOSE. To evaluate the fit of a three-unit metal framework of fixed dental prostheses made by subtractive and additive manufacturing. MATERIALS AND METHODS. One master model of metal was fabricated. Twenty silicone impressions were made on the master die, working die of 10 poured with Type 4 stone, and working die of 10 made of scannable stone. Ten three-unit wax frameworks were fabricated by wax-up from Type IV working die. Stereolithography files of 10 three-unit frameworks were obtained using a model scanner and three-dimensional design software on a scannable working die. The three-unit wax framework was fabricated using subtractive manufacturing (SM) by applying the prepared stereolithography file, and the resin framework was fabricated by additive manufacturing (AM); both used metal alloy castings for metal frameworks. Marginal and internal gap were measured using silicone replica technique and digital microscope. Measurement data were analyzed by Kruskal-Wallis H test and Mann-Whitney U-test (${\alpha}=.05$). RESULTS. The lowest and highest gaps between premolar and molar margins were in the SM group and the AM group, respectively. There was a statistically significant difference in the marginal gap among the 3 groups (P<.001). In the marginal area where pontic was present, the largest gap was $149.39{\pm}42.30{\mu}m$ in the AM group, and the lowest gap was $24.40{\pm}11.92{\mu}m$ in the SM group. CONCLUSION. Three-unit metal frameworks made by subtractive manufacturing are clinically applicable. However, additive manufacturing requires more research to be applied clinically.

다양한 삼차원 프린팅 시스템으로 제작된 다이의 정확도 비교 (Accuracy of dies fabricated by various three dimensional printing systems: a comparative study)

  • 백주원;신수연
    • 구강회복응용과학지
    • /
    • 제36권4호
    • /
    • pp.242-253
    • /
    • 2020
  • 목적: 이 연구의 목적은 3D 프린팅으로 제작된 다이의 정확도를 인상재와 치과용 석고를 이용하여 제작한 기존 방식 다이와 비교하고 체적 변화를 평가하여 정확도를 비교하는 것이다. 연구 재료 및 방법: 치과용 모델 하악 우측 제1대구치를 준비하여 스캔한 뒤 polyetherketoneketone (PEKK)으로 기준 다이를 제작한다. 기존 방식 다이는 기준 다이를 polyvinylsiloxane로 인상채득한 뒤 Type IV 치과용 석고를 부었다. 3D 프린팅 시스템의 경우 기준 다이를 스캔하고 3개의 서로 다른 3D 프린터를 이용하여 모델로 변환하였다. 4가지 방법으로 각각 10개의 표본을 만들었다. 3D 표면매칭 소프트웨어를 사용하여 기준 다이와 중첩하였다. 통계 분석을 위해 Kruskal-Wallis test, Mann-Whitney U test를 수행하였다(P < 0.05). 결과: 기준 다이와 비교하여 기존 방식, Stereolithography로 제작된 다이를 제외하고는 각 방식으로 제작된 다이의 체적 변화가 상당히 있었다(P < 0.05). 기존 방식으로 제작된 다이는 3D 프린팅된 다이보다 체적 변화가 가장 적었다(P < 0.05). Stereolithography로 제작된 3D 프린팅 다이는 다른 3D 프린터 중에서 체적 변화가 가장 적었다(P < 0.05). 결론: 기존 방식의 다이는 3D 프린팅 다이보다 더 정확했지만 3D 프린팅 다이는 임상적으로 허용되는 범위 내에 있었다. 따라서 3D 프린팅 다이는 수복물 제작에 사용할 수 있다.

인상채득 후 시간경과에 따른 고무인상재의 체적변화 (AN EVALUATION OF THE TIME-DEPENDENT DIMENSIONAL STABILITY OF ELASTOMERIC IMPRESSION MATERIALS)

  • 이홍석;조석규;윤태호;박주미;송광엽
    • 대한치과보철학회지
    • /
    • 제44권4호
    • /
    • pp.363-373
    • /
    • 2006
  • Statement of Problem : The accuracy and dimensional stability of elastomeric impression materials have been the subject of numerous investigation. Few studies have addressed the effect of changes in time on the dimensional stability of impression materials. Purpose: The purpose of this investigation was to evaluate the effects of elastomeric impression materials and storage time on dimensional stability. Materials and methods: A total of 75 impressions were made of epoxy resin dies mimicked prepared 3-unit fixed partial denture. The dies had 1 buccolingual, 1 mesiodistal and 1 occlusogingival lines and interpreped dot. Impression materials investigated included two polyether impression materials and three polyvinylsiloxane impression material. 15 specimens were made of each impression material and poured by type IV stone over times (30 minutes, 24 hours, 72 hours) after mixing; the same examiner measured each specimen 3 times at a magnification of 3.5$\times$. All statistical tests were performed with the level of significance set at .05. Results : The results indicated that significant difference at any measuring point of stone dies of the polyether impression materials and when measurements at 30 minutes, 24 hours, and 72 hours were compared ; the length of measuring point increased significantly as time passed by. However this result is not significant clinically. Analysis also showed significant differences at any measuring point when polyvinylsiloxane and polyether impression materials were compared and significant differences clinically. Conclusion: Under the conditions of this study, the shrinkage rate of the polyvinylsiloxane and polyether impression materials significantly increased as time passed by. The polyether impression materials showed higher shrinkage significantly, while the shrinkage rate of all five materials showed a significant time-dependent increase.

드릴 반경 설정이 보철물 가공에 미치는 영향 (Effect of drill radius setting on prosthesis machining)

  • 김총명;김소리;조미향
    • 대한치과기공학회지
    • /
    • 제40권1호
    • /
    • pp.1-8
    • /
    • 2018
  • Purpose: The purpose of this study is to evaluate the trueness and fitness of machined prostheses according to drill radius setting in CAD software. Methods: For this study, standard abutment were replicated in Type IV stone. The stone abutment were scanned using a dental scanner. The CAD design software was designed using scanned abutment data. When designing, the drill radius was set to 0.3 mm and 0 mm, respectively, and saved. The saved design data was milled using a milling machine (n=13). The inner surface of the milled crown was scanned. The trueness and fitness were measured using the inner scan data of prostheses. Independent t-tests were performed to identify significant differences in each data. Results: Trueness values of the data saved with 0.3 mm and 0 mm drill radius were $18.9{\pm}2.3{\mu}m$ and $19.1{\pm}0.9{\mu}m$, respectively. There was no statistically significant difference between the groups. Fitness values of the data saved with 0.3 mm and 0 mm drill radius were $65.5{\pm}0.8{\mu}m$ and $33.8{\pm}1.0{\mu}m$, respectively. There was a statistically significant difference between the groups (p<.05). Conclusion : Setting the drill radius is important to produce clinically good fit prostheses.

유리섬유 보강재를 삽입한 하악 레진의치 인상면의 정밀성 평가 (Precision evaluation of impression surface of lower complete dentures reinforced with glass fiber)

  • 김동연;양천승;이광영;김지환
    • 대한치과기공학회지
    • /
    • 제42권1호
    • /
    • pp.27-33
    • /
    • 2020
  • Purpose: This study is to compare and analyze the precision of glass fiber resin dentures. Methods: A lower edentulous model was prepared. Ten study models were produced using Type IV stone. Ten wax lower resin dentures containing artificial teeth were prepared. The lower wax denture was buried with plaster and deflasking was performed to remove the wax. Five conventional lower resin dentures and five glass fiber lower resin dentures were produced. The scanning spray was coated on the impression surface and then scanned. Independent sample t-test were performed using statistical software. Results: In the color different map, which is a qualitative evaluation, the green area of the precision of the conventional lower resin denture occupied the whole. The glass fiber conventional resin dentures had many negative and positive area. In quantitative evaluation, the RMS of conventional lower resin was 89.83 ㎛ and that of fiberglass resin was 224.92 ㎛. The two groups showed statistically significant differences (p<0.05). Conclusion: Conventional lower resin dentures were superior in precision, and glass fiber resin dentures would have to improve the process.

비접촉식 구강외 스캐너와 비디오방식 구강내 스캐너를 이용하여 제작된 보철물의 내면정확도 비교 (Comparison of the Internal Fitness of Prostheses Fabricated with Non-Contact Extra-Oral Scanner and Intra-Oral Video Scanner)

  • 박진영;김지환;정일도;이광영;김원수
    • 대한치과기공학회지
    • /
    • 제41권4호
    • /
    • pp.263-269
    • /
    • 2019
  • Purpose: The purpose of this study was to evaluate the internal fitness of prostheses fabricated with non-contact extra-oral scanner and those fabricated with intra-oral video scanner, with a comparative accuracy analyses of their precision and trueness. Methods: A polymethyl methacrylate (PMMA) model was fabricated by replicating a master model. The prostheses in the first group were fabricated based on the PMMA model with an intra-oral video scanner (IVS group). Following the fabrication of work models with Type IV Stone that were based on the PMMA model, the prostheses in the second group were fabricated with a non-contact extra-oral scanner (ENB group). The precision and trueness of the prostheses were calculated from comparisons of the three-dimensional images of the internal surfaces of the prostheses and those of the master model. Kruskal-Wallis tests were used to determine the statistical significance, with the level of type 1 error set at 0.05. Results: Trueness (P < 0.009) and precision (P < 0.001) did not differ significantly between the ENB and IVS groups. The IVS group exhibited lower trueness values and larger precision values than the ENB group. Conclusion: Although no significant differences were found in the internal fitness of the prostheses that were fabricated by the two different scanners, the intraoral video scanner-fabricated prostheses had better trueness, whereas the non-contact extra-oral scanner-fabricated prostheses had better precision.

치과 도재용 금속의 재사용에 따른 금속과 도재간의 결합 강도에 관한 연구 (A STUDY ON THE BOND STRENGTH BETWEEN REUSED DENTAL ALLOYS AND PORCELAIN)

  • 김인;양홍서
    • 대한치과보철학회지
    • /
    • 제31권2호
    • /
    • pp.181-190
    • /
    • 1993
  • The purpose of this study was to evaluate the effect of shear bond strength between various percentage of reused dental ceramic alloys and porcelain. One hundred specimens were made of one semiprecious alloy and three nonprecious alloys. Each alloy group was subdevided into five groups according to the additional precentage of new alloy. Group I specimens were made of 100% new alloy and served as the control of the investigation. Group II specimens were made of once-cast alloy with 75% new alloy. Group III specimens were made of once-cast alloy with 50% new alloy. Group IV specimens were made of once-cast alloy with 25% new alloy. Group V specimens were made of 100% recast alloy. Five specimens were made for each group of the alloy combinations. The test specimens were prepared by firing porcelain doughnuts on the alloy rod surface, and invested in dental stone. Bond strengths were measured by Instron universal testing machine at a crosshead speed of 0.5mm/min. The fractured surface of metal specimens were examined under the scanning electron microscope. The obtained results were as follows : 1. The shear bond strength of Albabond showed no significant difference between control group and reused alloy group. 2. The shear bond strength of reused alloy groups of nonprecious alloys were lower than that of control groups. 3. The shear bond strength between porcelain and metal in semiprecious alloy was higher than in nonprecious alloys 4. In nonprecious alloys. Rexillium III showed the highest bond strength value and Excelalloy showed the lowest shear bond strength value. 5. Regardless of the type of alloys and additional proportion of new alloys, scanning electron microscope photographs of the fracture surface between alloy and porcelain revealed simillar semiprecious alloy and nonprecious alloys.

  • PDF

적층가공방식을 이용한 열가압 세라믹 라미네이트 비니어의 적합도: 3차원 분석 (Fitness of heat - pressed ceramic laminate veneer using additive manufacturing process: 3 Dimensional analysis)

  • 강신영;이하나;김어빈;이경은;김지환;김웅철
    • 대한치과기공학회지
    • /
    • 제39권3호
    • /
    • pp.137-143
    • /
    • 2017
  • Purpose: The purpose of this study is to analyze the fitness of heat - pressed ceramic laminate veneers fabricated using the additive manufacturing. Methods: Impression was replicated by using light body silicone and heavy body silicone on the custom tray, and it was fabricated using Type IV Stone. The test specimens were prepared by using a dental scanner, a laminating veneer using a dental design program, and a specimen with a 3D printer. The control specimens were prepared by the lost wax technique and heat - pressed to fabricate the specimens. The data of the specimens were measured by the RMS value of the internal fitness a using a 3-dimensional measurement program. Results: The Stereolithography laminate veneer group was measured at $78.10(4.09){\mu}m$ and the LWV group was measured at $31.50(5.10){\mu}m$. There is a significant difference between the two groups (p<0.001) Conclusion : Evaluation of fitness laminate veneers was fabricated by additive manufacturing showed the difference statistically significantly and clinically acceptable result.

세 가지 방식으로 제작된 레진코핑의 내면적합성 평가: 3차원적 분석 (Assessment of internal fitness on resin copings fabricated by 3 - ways methods: Three - dimensional analysis)

  • 강신영;박진영;김동연;김웅철
    • 대한치과기공학회지
    • /
    • 제39권1호
    • /
    • pp.17-24
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate the internal fitness of the resin coping that was fabricated by the traditional and Digital manufacturing methods through 3-dimensional analysis. Methods: maxillary right second molar was chosen implant master model. Custom-built impression trays were manufactured. After screwing the pick-up impression coping onto the master cast, impressions were made with silicone impression. The Working model was then made with type IV stone. The coping was fabricated: SLAC group (n=8), APPC group (n=8), LAPC group (n=8) Resin coping data was measured by using a three-dimensional evaluation program. Internal fitness was calculated by RMS (Root Mean Square).It measures mean and Standard Deviation (SD). Results: Three groups are measured $47.11{\pm}(3.08){\mu}m$ total RMS of SLAC group, $48.35({\pm}1.55{\mu}m)$ for total RMS of LAPC group, $43.45{\pm}2.09{\mu}m$ for total RMS of APPC group. Measured value is gradually increased. Followed by autopolymerized pattern resin; Stereolithography resin, Light-activated pattern resin But there were no differences stastically(P>0.321). Conclusion: Evaluation of internal fitness on Resin copings was fabricated by three-ways methods showed that no differences statistically significant and clinically acceptable results.

유리섬유 보강재로 제작한 레진의치의 온성 전·후에 따른 정확성 평가 (Accuracy evaluation of resin complete denture made with glass fiber mesh reinforcement before and after curing)

  • 김동연;정일도;박진영;강신영;김지환;김웅철
    • 대한치과기공학회지
    • /
    • 제39권1호
    • /
    • pp.25-33
    • /
    • 2017
  • Purpose: The aim of this study was to evaluate accuracy of glass fiber mesh complete denture of before and after curing. Methods: Edentulous model was selected as the master model. Ten study models were made by Type IV stone. Wax complete dentures were produced by the denture base and artificial teeth. CD and GD groups were measured six measurement distance before curing. The wax complete denture was investment after measurement is completed. Using a heat polymerization resin was injected resin. After injecting the resin it was curing. A complete denture was re-measured after curing. The measured data was verified by paired t-test. Results: Overall CD group was larger the value of the measured length. In the CD group, A-D point was larger. The smallest point was the B-D point. However, there was no statistically significant difference only C-D point(p>0.05). In the GD group, A-B point was larger. but B-D point was the smallest. A-D and B-C statistically points showed significant differences(p<0.05). Conclusion: Glass fiber mesh resin complete denture can be clinically applied to the edentulous patient.