AN EVALUATION OF THE TIME-DEPENDENT DIMENSIONAL STABILITY OF ELASTOMERIC IMPRESSION MATERIALS

인상채득 후 시간경과에 따른 고무인상재의 체적변화

  • Lee Hong-Seok (Department of Prosthodontics, School of Dentistry, Chonbuk National University) ;
  • Cho Suck-Kyu (Department of Prosthodontics, School of Dentistry, Chonbuk National University) ;
  • Yoon Tae-Ho (Department of Prosthodontics, School of Dentistry, Chonbuk National University) ;
  • Park Ju-Mi (Department of Prosthodontics, School of Dentistry, Chonbuk National University) ;
  • Song Kwang-Yeob (Department of Prosthodontics, School of Dentistry, Chonbuk National University)
  • 이홍석 (전북대학교 치과대학 치과보철학교실) ;
  • 조석규 (전북대학교 치과대학 치과보철학교실) ;
  • 윤태호 (전북대학교 치과대학 치과보철학교실) ;
  • 박주미 (전북대학교 치과대학 치과보철학교실) ;
  • 송광엽 (전북대학교 치과대학 치과보철학교실)
  • Published : 2006.08.01

Abstract

Statement of Problem : The accuracy and dimensional stability of elastomeric impression materials have been the subject of numerous investigation. Few studies have addressed the effect of changes in time on the dimensional stability of impression materials. Purpose: The purpose of this investigation was to evaluate the effects of elastomeric impression materials and storage time on dimensional stability. Materials and methods: A total of 75 impressions were made of epoxy resin dies mimicked prepared 3-unit fixed partial denture. The dies had 1 buccolingual, 1 mesiodistal and 1 occlusogingival lines and interpreped dot. Impression materials investigated included two polyether impression materials and three polyvinylsiloxane impression material. 15 specimens were made of each impression material and poured by type IV stone over times (30 minutes, 24 hours, 72 hours) after mixing; the same examiner measured each specimen 3 times at a magnification of 3.5$\times$. All statistical tests were performed with the level of significance set at .05. Results : The results indicated that significant difference at any measuring point of stone dies of the polyether impression materials and when measurements at 30 minutes, 24 hours, and 72 hours were compared ; the length of measuring point increased significantly as time passed by. However this result is not significant clinically. Analysis also showed significant differences at any measuring point when polyvinylsiloxane and polyether impression materials were compared and significant differences clinically. Conclusion: Under the conditions of this study, the shrinkage rate of the polyvinylsiloxane and polyether impression materials significantly increased as time passed by. The polyether impression materials showed higher shrinkage significantly, while the shrinkage rate of all five materials showed a significant time-dependent increase.

Keywords

References

  1. Chee WW, Donovan TE. Polyvinyl siloxane impression materials: a review of properties and techniques. J Prosthet Dent 1992; 68:728-32 https://doi.org/10.1016/0022-3913(92)90192-D
  2. Blatz MB, Sadan A, Burgess JO, Mercante D, Holst S. Selected characteristics of a new polyvinyl siloxane impression materials A randomized clinical trial. Quintessence Int 2005;36:97-104
  3. Berg JC, Johnson GH, Lepe X, AdanPlaza S. Temperature effects on the rheological properties of current polyether and polysiloxane impression materials during setting. J Prosthet Dent 2003; 90: 150-61 https://doi.org/10.1016/S0022-3913(03)00297-X
  4. Braden M, Causton B, Clarke RL. A polyether impression rubber. J Dent Res 1972;51:889-96 https://doi.org/10.1177/00220345720510042701
  5. Wadhwani CPK, Johnson GH, Lepe X, Radigrodski AJ. Accuracy of newly formulated fast-setting elastomeric impression materials. J Prosthet Dent 2005; 93:530-9 https://doi.org/10.1016/j.prosdent.2005.03.007
  6. Marcinak CF, Young FAm Draughn RA, Flemming WR. Linear dimensional changes in elastic impression materials. J Dent Res 1980;59: 1152-5 https://doi.org/10.1177/00220345800590071001
  7. Bailey JH, Donovan TE, Preston JD. The dimensional accuracy of improved dental stone, silberplated, and epoxy resin die materials. J Prosthet Dent 1988; 59: 307-10 https://doi.org/10.1016/0022-3913(88)90178-3
  8. Lacy AM, Bellman T, Fukui H, Jendresen MD. Time-dependent accuracy of elastomer impression materials. Part I. Condensation silicones. J Prosthet Dent 1981 ;45 :209-15 https://doi.org/10.1016/0022-3913(81)90342-5
  9. Lacy AM, Bellman T, Fukui H, Jendresen MD. Time-dependent accuracy of elas-tomer impression materials. Part II. Polyether, polysulfides, and polyvinyl-siloxane. J Prosthet Dent 1981;45:329-33 https://doi.org/10.1016/0022-3913(81)90400-5
  10. Jonhson GH, Craig RG, Accuracy of four types of rubber impression materials compared with time of pour and a repeat pour of models. J Prosthet Dent 1985; 53:484-90 https://doi.org/10.1016/0022-3913(85)90630-4
  11. Stackhouse JA. A comparison of elastic impression materials. J Prosthet Dent 1975;34:305-313 https://doi.org/10.1016/0022-3913(75)90108-0
  12. American National Standard/American Dental Association. Specification no. 19 for non-aqueous, elastomeric dental impressions. J Am Dent Assoc 1977:94:73341
  13. Tjan AHL, Nemetz H, Nguyen LTP, Contino R. Effect of tray space on the accuracy of monophasic polyvinylsiloxane impressions. J Prosthet Dent 1992;68: 19-28 https://doi.org/10.1016/0022-3913(92)90278-I
  14. Cho GC, Chee WWL. Distortion of disposable plastic stock trays when with putty vinyl polysiloxane impression materials. J Prosthet Dent 2004;92:354-8 https://doi.org/10.1016/j.prosdent.2004.07.020
  15. Johnson GH, Craig RG. Accuracy of additional silicones as a function of technique. J Prosthet Dent 1986;55:197-203 https://doi.org/10.1016/0022-3913(86)90342-2
  16. Lampe I, Marton S, Hegedus C. Effect of mixing technique on shrinkage rate of one polyether and two polyvinyl siloxane impression materials. Int J Prosthodont 2004;17:590
  17. Piwowarczyk A, Ottl P, Buchler A, Lauer HC, Hoffmann A. In vitro study on the dimensional accuracy of selected materials for monophase elastic impression making. Int J Prosthodont 2002;15:168-174
  18. Eames WB, Wallace SW, Suway NB, Rogers LB. Accuracy and dimensional stability of elastomeric impression materials. J Prosthet Dent 1979;42:159-162 https://doi.org/10.1016/0022-3913(79)90166-5
  19. Petrie CS, Walker MP. O' Mahony AM, Spencer P. Dimensional accuracy and surface detail reproduction of two hydrophilic vinyl polysiloxane impression materials tested under dry, moist, and wet conditions. J Prosthet Dent 2003;90:365-72 https://doi.org/10.1016/S0022-3913(03)00515-8
  20. Luebke RJ, Scandrett FR, Kerber PE. The effect of delayed and second pours on elastomeric impression material accuracy. J Prosthet Dent 1979;41 :517-21 https://doi.org/10.1016/0022-3913(79)90084-2
  21. Tjan AHL, Whang SB, Tjan AH, Sarkissian R. Clinically oriented evaluation of the accuracy of commonly used impression materials. J Prosthet Dent 1986; 56: 4-8 https://doi.org/10.1016/0022-3913(86)90272-6