• 제목/요약/키워드: Two-well

검색결과 19,933건 처리시간 0.047초

Reference-Intrinstic Analysis for the Difference between Two Normal Means

  • Jang, Eun-Jin;Kim, Dal-Ho;Lee, Kyeong-Eun
    • Communications for Statistical Applications and Methods
    • /
    • 제14권1호
    • /
    • pp.11-21
    • /
    • 2007
  • In this paper, we consider a decision-theoretic oriented, objective Bayesian inference for the difference between two normal means with unknown com-mon variance. We derive the Bayesian reference criterion as well as the intrinsic estimator and the credible region which correspond to the intrinsic discrepancy loss and the reference prior. We illustrate our results using real data analysis as well as simulation study.

산악지 쌍글 수로터널 해석에 대한 고찰 (A STUDY ON THE ANALYSIS ZONE OF MOUNTAIN TWIN WATER TUNNELS)

  • 백영식;김홍택;임수빈
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1993년도 봄 학술회 논문집
    • /
    • pp.21-26
    • /
    • 1993
  • Using the well-known FLAC program an analylical parametric study was made to investigate the horizontal and vartical solution zone applied to the mountain water tunnel analysis. In the analyses two different heights(30m, 130m) of overburden soils measured from the center of a tunnel and three different coafflclants of lateral earth pressures(0.25, 0.75, 0.5) were adopted. Also the effected of plliar width between twin tunnels, having two different heighte of overburdon soils as well as different soil conditions, were analyzed.

  • PDF

Discovery of the Extraplanar FUV Halo of NGC 891

  • 선광일
    • 천문학회보
    • /
    • 제35권1호
    • /
    • pp.76.2-76.2
    • /
    • 2010
  • We report the extended far-ultraviolet (FUV) halo of NGC 891 above the galactic plane. The FUV intensity distribution is well described by two exponential components, one with the scale height of ~0.34 kpc and the other of ~2.3 kpc. The extraplanar FUV halo is traceable up to > 5 kpc. The FUV halo is attributable to scattered-off starlight by extraplanar dust. Using Monte-Carlo radiative transfer simulations, the FUV intensity distribution along the minor axis is found to be well modeled with two dust comonents. Its implications are discussed.

  • PDF

목포항의 부진동에 관한 연구 (A Study on the Seich of Mok-po.Harbour)

  • 정명선;강신영;박한일;유홍선;민병언
    • 한국항해학회지
    • /
    • 제13권1호
    • /
    • pp.63-75
    • /
    • 1989
  • A two dimensional numerical model as well as theoretical formula are used to investigate the seich characteristics of Mok-po harbour. The natural periods of the first two modes computed from the numerical mode are about 34 minutes and 12 minutes which are well consistent with those by the theoretical formula.

  • PDF

분할링에 관한 응력해석 (Stress analysis of split ring)

  • 이영식;조선휘;남준우
    • 오토저널
    • /
    • 제6권1호
    • /
    • pp.71-77
    • /
    • 1984
  • Stress analysis of split ring with four different radius ratios under the compressive load is made by the photoelastic experiment and the numerical analysis through the FEM. The results of the two methods agreed well. Above results are also compared with those of the theoretical formula in order to confirm the range in which the formula of the curved bar is applied in connection with the radius ratio. The results of the two methods agreed well with those of the formula for the radius ratio, 3/2 and 9/7 within small errors of around 7% and 5% respectively.

  • PDF

실내 공기질 평가를 위한 2구획 모델의 개발 (Development of the Two-Zone Model to Estimate the Air Quality in Indoor Environments)

  • 조석호;양성환;이봉헌;정성욱;이병호
    • 한국환경과학회지
    • /
    • 제7권6호
    • /
    • pp.745-751
    • /
    • 1998
  • The well-mixed room model has been traditionally used to predict the concentrations of contaminants in indoor environments. However, this is inappropriate because the flow fields in many indoor environments distribute contaminants non-uniformly, due to imperfect air mixing. Thus, some means used to describe an imperfectly mixed room are needed. The simplest model that accounts for imperfect air mixing is a two-zone model. Therefore, this study on development of computer program far the two-zone model is carried out to propose techniques of estimating the concentration of contaminants in the room. To do this, an important consideration is to divide a room into two-zone, i.e. the lower and upper zone assuming that the air and contaminants are well mixed within each zone. And between the zones the air recirculation is characterized through the air exchange parameter. By this basic assumption, the equations for the conservation of mass are derived for each zone. These equations are solved by using the computational technique. The language used to develope the program is a VISUAL BASIC. The value of air exchange coefficient($f_12$) is the most difficult to forecast when the concentrations of contaminants in an imperfectly mixed room are estimated by the two-zone model. But, as the value of $f_12$ increases, the air exchange between each zone increases. When the value of $f_12$ is approximately 15, the concentrations in both zone approach each other, and the entire room may be approximately treated as a single well-mixed room. Therefore, this study is available for designing of the ventilation to improve the air quality of indoor environments. Also, the two-zone model produces the theoretical base which may be extended to the theory for the multi-zone model, that will be contributed to estimate the air pollution in large enclosures, such as shopping malls, atria buildings, atria terminals, and covered sports stadia.

  • PDF

WELL-BALANCED ROE-TYPE NUMERICAL SCHEME FOR A MODEL OF TWO-PHASE COMPRESSIBLE FLOWS

  • Thanh, Mai Duc
    • 대한수학회지
    • /
    • 제51권1호
    • /
    • pp.163-187
    • /
    • 2014
  • We present a multi-stage Roe-type numerical scheme for a model of two-phase flows arisen from the modeling of deflagration-to-detonation transition in granular materials. The first stage in the construction of the scheme computes the volume fraction at every time step. The second stage deals with the nonconservative terms in the governing equations which produces states on both side of the contact wave at each node. In the third stage, a Roe matrix for the two-phase is used to apply on the states obtained from the second stage. This scheme is shown to capture stationary waves and preserves the positivity of the volume fractions. Finally, we present numerical tests which all indicate that the proposed scheme can give very good approximations to the exact solution.

Two optimal threshold criteria for ROC analysis

  • Cho, Min Ho;Hong, Chong Sun
    • Journal of the Korean Data and Information Science Society
    • /
    • 제26권1호
    • /
    • pp.255-260
    • /
    • 2015
  • Among many optimal threshold criteria from ROC curve, the closest-to-(0,1) and amended closest-to-(0,1) criteria are considered. An ROC curve that passes close to the (0,1) point indicates that two models are well classified. In this case, the ROC curve is located far from the (1,0) point. Hence we propose two criteria: the farthest-to-(1,0) and amended farthest-to-(1,0) criteria. These criteria are found to have a relationship with the KolmogorovSmirnov statistic as well as some optimal threshold criteria. Moreover, we derive that a definition for the proposed criteria with more than two dimensions and with relations to multi-dimensional optimal threshold criteria.

저전압 DRAMs을 위한 2-단계 2-위상 VPP 전하 펌프 발생기 (A Two-Stage Two-Phase Boosted Voltage Generator for Low-Voltage DRAMs)

  • 조성익;유성한;박무훈;김영희
    • 대한전자공학회논문지SD
    • /
    • 제40권6호
    • /
    • pp.442-446
    • /
    • 2003
  • 본 논문에서는 몸체효과와 문턱전압 손실이 제거된 새로운 2-단계 2-위상 VPP 전하펌프 발생기를 제안하였다. 새롭게 제안된 회로의 동작을 검증하기 위하여 0.18um Triple-Well CMOS 공정을 사용하였으며, VPP의 전압 레벨은 VDD가 문턱전압 이상일 때 3VDD가 공급되는 결과를 얻었다.

분할유동차원 2층 대수층에서의 투수성, 층간흐름, 저류성의 효과 (Permeability, crossflow and storativity effects in two-layer aquifer system with fractional flow dimension)

  • 함세영
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2000년도 추계학술대회
    • /
    • pp.81-84
    • /
    • 2000
  • Two-layer aquifer system with fractional flow dimension is composed of contiguous two layers: Layer 1 (lower layer) and Layer 2 (upper layer) with different permeability and specific storage each other. For this aquifer system, we assume that groundwater flow originates only from Layer 1 on the pumping well. The aquifer system considers wellbore storage and skin effects on the pumping well. Dimensionless drawdown curves for different flow dimensions are analyzed for different lambda (λ, crossflow coefficient) values, kappa ($textsc{k}$, permeability ratio between Layer 1 and Layer 2) values and omega ($\omega$, storativity ratio between Layer 1 and Layer 2) values. The curves for Layer 1 and Layer 2 show characteristic trend each other.

  • PDF