The Evaluation of TrueX Reconstruction Method in Low Dose (저선량에서의 TrueX 재구성 방법에 의한 유용성 평가)

  • Oh, Se-Moon;Kim, Kye-Hwan;Kim, Seung-Jeong;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.83-87
    • /
    • 2011
  • Purpose: Recently in diagnostics area PET/CT is using a variety of areas including oncology, as well as in cardiology, neurology, etc. While increasing in the importance of PET/CT, there are various researches in the image quality related to reconstruction method. We compared and tested Iterative 2D Reconstruction Method with True X Reconstruction method by Siemens through phantom experiment, so we can see increasing of clinical usefulness of PET/CT. Materials and Methods: We measured contrast ratio and FWHM due to evaluating images on dose and experiment using Biograph 40 True Point PET/CT (Siemens, Germany). Getting a result of contrast ratio and FWHM, we used NEMA IEC PET body phantom (Data Spectrum Corp.) and capillary tube. We used the current TrueX and the previous Iterative 2D algorithm for all images which have 10 minutes long. Also, a clinical suitability of parameter for Iterative 2D and a recommended parameter by Siemens for True X are applied to the experiment. Results: We tested FWHM using capillary tube. As a result, TrueX was less than Iterative 2D. Also, the differences of FWHM get bigger in low dose. On the other hand, we tested contrasts ratio using NEMA IEC PET body phantom. As a result, TrueX was better aspect than Iterative 2D. However, there was no difference in dose. Conclusion: In this experiment, TrueX get higher results of contrast ratio and spatial resolution than Itertive 2D through experiment. Also, in the reconstruction result through TrueX, TrueX had better aspect of resolution than Iterative 2D in low dose. However, contrast ratio had no specific difference. In other words, TrueX reconstruction method in PET/CT had higher clinical value in use because TrueX can reduce exposure of patient and had a better quality of screen.

  • PDF

A Copper Shield for the Reduction of X-γ True Coincidence Summing in Gamma-ray Spectrometry

  • Byun, Jong-In
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.4
    • /
    • pp.137-142
    • /
    • 2018
  • Background: Gamma-ray detectors having a thin window of a material with low atomic number can increase the true coincidence summing effects for radionuclides emitting X-rays or gamma-rays. This effect can make efficiency calibration or spectrum analysis more complicated. In this study, a Cu shield was tested as an X-ray filter to neglect the true coincidence summing effect by X-rays and gamma-rays in gamma-ray spectrometry, in order to simplify gamma-ray energy spectrum analysis. Materials and Methods: A Cu shield was designed and applied to an n-type high-purity germanium detector having an $X-{\gamma}$ summing effect during efficiency calibration. This was tested using a commercial, certified mixed gamma-ray source. The feasibility of a Cu shield was evaluated by comparing efficiency calibration results with and without the shield. Results and Discussion: In this study, the thickness of a Cu shield needed to avoid true coincidence summing effects due to $X-{\gamma}$ was tested and determined to be 1 mm, considering the detection efficiency desired for higher energy. As a result, the accuracy of the detection efficiency calibration was improved by more than 13% by reducing $X-{\gamma}$ summing. Conclusion: The $X-{\gamma}$ summing effect should be considered, along with ${\gamma}-{\gamma}$ summing, when a detection efficiency calibration is implemented and appropriate shielding material can be useful for simplifying analysis of the gamma-ray energy spectra.

Performance Test of the Iterative Method and Newly Developed True X Method (PET 검사에서 Iterative 재구성 방법과 True X 재구성 방법에 따른 영상의 균일성 및 대조도 비교 평가)

  • Choi, Jae-Min;NamKung, Chang-Kyeong;Park, Seung-Yong;Nam, Ki-Pyo;Lim, Ki-Cheon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.20-24
    • /
    • 2009
  • Objective: In this study, the differences between two reconstruction methods were analyzed by comparing image uniformity and contrast according to Iteration and Subset, which were altered through the Iterative method and True X method, used in Siemens' PET/CT studies. Methods: The Phantom images were obtained by exposure for two minutes per one bed. To determine the image uniformity, the Coefficient of variance was used. Also, in order to compare the contrast value, we measured and analyzed the ratio of the SUV mean of Phantom image's hot spheres and the background. Results: Under the same reconstruction conditions (Iteration and Subset) of CV, the Iterative method was higher than the True X method. In the comparison of the SUV mean ratio of the background and hot sphere, the True X method had a closer rate than the Iterative method. Conclusion: The newly developed True X reconstruction method is better than the previously used Iterative method in terms of uniformity and contrast. However, the date for this study was only obtained using the Phantom device. In order to obtain more accurate and useful information from the experiment, further research should be conducted. Also, it is necessary to find the appropriate standards for Iteration and Subset for further experimentation.

  • PDF

EFFICINET GENERATION OF MAXIMAL IDEALS IN POLYNOMIAL RINGS

  • Kim, Sunah
    • Bulletin of the Korean Mathematical Society
    • /
    • v.29 no.1
    • /
    • pp.137-143
    • /
    • 1992
  • The purpose of this paper is to provide the affirmative solution of the following conjecture due to Davis and Geramita. Conjecture; Let A=R[T] be a polynomial ring in one variable, where R is a regular local ring of dimension d. Then maximal ideals in A are complete intersection. Geramita has proved that the conjecture is true when R is a regular local ring of dimension 2. Whatwadekar has rpoved that conjecture is true when R is a formal power series ring over a field and also when R is a localization of an affine algebra over an infinite perfect field. Nashier also proved that conjecture is true when R is a local ring of D[ $X_{1}$,.., $X_{d-1}$] at the maximal ideal (.pi., $X_{1}$,.., $X_{d-1}$) where (D,(.pi.)) is a discrete valuation ring with infinite residue field. The methods to establish our results are following from Nashier's method. We divide this paper into three sections. In section 1 we state Theorems without proofs which are used in section 2 and 3. In section 2 we prove some lemmas and propositions which are used in proving our results. In section 3 we prove our main theorem.eorem.rem.

  • PDF

True Digestibility of Phosphorus in Different Resources of Feed Ingredients in Growing Pigs

  • Wu, X.;Ruan, Z.;Zhang, Y.G.;Hou, Y.Q.;Yin, Y.L.;Li, T.J.;Huang, R.L.;Chu, W.Y.;Kong, X.F.;Gao, B.;Chen, L.X.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.21 no.1
    • /
    • pp.107-119
    • /
    • 2008
  • To determine the true digestible phosphorus (TDP) requirement of growing pigs, two experiments were designed with the experimental diets containing five true digestible P levels (0.16%, 0.20%, 0.23%, 0.26% and 0.39%) and the ratio of total calcium to true digestible P (TDP) kept at 2:1. In Experiment 1, five barrows (Duroc${\times}$Landrace${\times}$Yorkshire) with an average initial body weight of 27.9 kg were used in a $5{\times}5$ Latin-square design to evaluate the effect of different dietary P levels on the digestibility and output of P and nitrogen. In Experiment 2, sixty healthy growing pigs (Duroc${\times}$Landrace${\times}$Yorkshire) with an average body weight (BW) of 21.4 kg were assigned randomly to one of the five dietary treatments (12 pigs/diet), and were used to determine the true digestible phosphorus (TDP) requirement of growing pigs on the basis of growth performance and serum biochemical indices. The results indicated that the true digestibility of P increased (p<0.05) linearly with increasing dietary TDP level below 0.26%. The true P digestibility was highest (56.6%) when dietary TDP was 0.34%. Expressed as g/kg dry matter intake (DMI), fecal P output increased (p<0.05) linearly with increasing P input. On the basis of g/kg fecal dry matter (DM), fecal P output was lowest for Diet 4 and highest (p<0.05) for Diet 5. The apparent digestibility of crude protein (CP) did not differ (p>0.05) among the five diets, with the average nitrogen output of 12.14 g/d and nitrogen retention of 66% to 74% (p>0.05), which suggested that there was no interaction between dietary P and CP protein levels. During the 28-d experimental period of Experiment 2, the average daily gain (ADG) of pigs was affected by dietary TDP levels as described by Eq. (1): $y=-809,532x^4+788,079x^3-276,250x^2+42,114x-1,759$; ($R^2=0.99$; p<0.01; y = ADG, g/d; x = dietary TDP, %), F/G for pigs by Eq. (2): $y=3,651.1x^4-3,480.4x^3+1,183.8x^2-172.5x+10.9$ ($R^2=0.99$; p<0.01; y = F/G; x = dietary TDP, %), and Total P concentrations in serum by Eq. (3): $y=-3,311.7x^4+3,342.7x^3-1,224.6x^2+195.6x-8.7$ (R2 = 0.99; p<0.01; y = total serum P concentration and x = dietary TDP, %). The highest ADG (782 g/d), the lowest F/G (1.07) and the highest total serum P concentration (3.1 mmol/L) were obtained when dietary TDP level was 0.34%. Collectively, these results indicate that the optimal TDP requirement of growing pigs is 0.34% of the diet at a total Ca to TDP ratio of 2:1.

Evaluation of Perfusion and Image Quality Changes by Reconstruction Methods in 13N-Ammonia Myocardial Perfusion PET/CT (13N-암모니아 심근관류 PET/CT 검사 시 영상 재구성 방법에 따른 관류량 변화와 영상 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.69-75
    • /
    • 2014
  • Purpose: The aim of this study was to evaluate changes of quantitative and semi-quantitative myocardial perfusion indices and image quality by image reconstruction methods in $^{13}N$-ammonia ($^{13}N-NH_3$) myocardial perfusion PET/CT. Materials and Methods: Data of 14 (8 men, 6 women) patients underwent rest and adenosine stress $^{13}N-NH_3$ PET/CT (Biograph TruePoint 40 with TrueV, Siemens) were collected. Listmode scans were acquired for 10 minutes by injecting 370MBq of $^{13}N-NH_3$. Dynamic and static reconstruction was performed by use of FBP, iterative2D (2D), iterative3D (3D) and iterative TrueX (TrueX) algorithm. Coronary flow reserve (CFR) of dynamic reconstruction data, extent(%) and total perfusion deficit (TPD) (%) measured in sum of 4-10 minutes scan were evaluated by comparing with 2D method which was recommended by vendor. The image quality of each reconstructed data was compared and evaluated by five nuclear medicine physicians through a blind test. Results: CFR were lower in TrueX 18.68% (P=0.0002), FBP 4.35% (P=0.1243) and higher in 3D 7.91% (P<0.0001). As semi-quantitative values, extent and TPD of stress were higher in 3D 3.07%p (P=0.001), 2.36%p (P=0.0002), FBP 1.93%p (P=0.4275), 1.57%p (P=0.4595), TrueX 5.43%p (P=0.0003), 3.93%p (P<0.0001). Extent and TPD of rest were lower in FBP 0.86%p (P=0.1953), 0.57%p (P=0.2053) and higher in 3D 3.21%p (P=0.0006), 2.57%p (P=0.0001) and TrueX 5.36%p (P<0.0001), 4.36%p (P<0.0001). Based on the results of the blind test for image resolution and noise from the snapshot, 3D obtained the highest score, followed by 2D, TrueX and FBP. Conclusion: We found that quantitative and semi-quantitative myocardial perfusion values could be under- or over-estimated according to the reconstruction algorithm in $^{13}N-NH_3$ PET/CT. Therefore, proper dynamic and static reconstruction method should be established to provide accurate myocardial perfusion value.

  • PDF

A Note on the Small-Sample Calibration

  • So, Beong-Soo
    • Journal of Korean Society for Quality Management
    • /
    • v.22 no.2
    • /
    • pp.89-97
    • /
    • 1994
  • We consider the linear calibration model: $y_1={\alpha}+{\beta}x_i+{\sigma}{\varepsilon}_i$, i = 1, ${\cdots}$, n, $y={\alpha}+{\beta}x+{\sigma}{\varepsilon}$ where ($y_1$, ${\cdots}$, $y_n$, y) stands for an observation vector, {$x_i$} fixed design vector, (${\alpha}$, ${\beta}$) vector of regression parameters, x unknown true value of interest and {${\varepsilon}_i$}, ${\varepsilon}$ are mutually uncorrelated measurement errors with zero mean and unit variance but otherwise unknown distributions. On the basis of simple small-sample low-noise approximation, we introduce a new method of comparing the mean squared errors of the various competing estimators of the true value x for finite sample size n. Then we show that a class of estimators including the classical and the inverse estimators are consistent and first-order efficient within the class of all regular consistent estimators irrespective of type of measurement errors.

  • PDF

WDM Optical True Time-Delay for X-Band Phased Array Antennas (X-밴드 위상 배열 안테나를 위한 WDM 광 실시간 지연선로)

  • Jung, Byung-Min;Shin, Jong-Dug;Kim, Boo-Gyoun
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.2
    • /
    • pp.162-166
    • /
    • 2007
  • In this paper, we propose a WDM optical true time-delay (OTTD) beam former for phased way antenna (PAA) systems. It is composed of a delay lines matrix and a multiwavelength source with discrete DFB laser diodes. The building block of a delay lines matrix is a $2\times2$ optical MEMS switch with proper fiber-optic delay line connected between cross ports. A $4\times3$ matrix using four DFB lasers has been fabricated with unit time-delay difference of 12 ps. Maximum time-delay error was measured to be -1.74 ps and +1.14 ps at a radiation angle of $46.05^{\circ}$, corresponding to error range of $-2.87^{\circ}\sim+1.88^{\circ}$. By measuring time-delays at six different RF frequencies from 5- to 10-GHz, we verified the true time-delay characteristic of our OTTD.

CONTINUOUS DERIVATIONS OF NONCOMMUTATIVE BANACH ALGEBRA

  • Park, Kyoo-Hong;Jung, Yong-Soo
    • Journal of applied mathematics & informatics
    • /
    • v.7 no.1
    • /
    • pp.319-327
    • /
    • 2000
  • In this paper we investigate the conditions for derivations under which the Singer-Wermer theorem is true for noncommutative Banach algebra A such that either [[D(x),xD(x)] ${\in}$ rad(A) for all $x{\in}$A or $D(x)^2$x+xD(x))$^2$${\in}$rad(A) for all $x{\in}$A, where rad(A) is the Jacobson radical of A, then $D(A){\subseteq}$rad(A).

Development of Stress-Modified Fracture Strain Criterion for Ductile Fracture of API X65 Steel (API X65 강의 연성파괴 해석을 위한 삼축응력 영향을 고려한 파괴변형률 기준 개발)

  • Oh Chang-Kyun;Kim Yun-Jae;Park Jin-Moo;Baek Jong-Hyun;Kim Woo-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.12 s.243
    • /
    • pp.1621-1628
    • /
    • 2005
  • This paper presents a stress-modified fracture strain for API X65 steel used for gas pipeline, as a function of stress triaxiality. To determine the stress-modified fracture strain, tension test of bars with four different notch radii, made of API X65 steel, is firstly performed, from which true fracture strains are determined as a function of notch radius. Then detailed elastic-plastic, large strain finite element (FE) analyses are performed to estimate variations of stress triaxiality in the notched bars with load. Combining experimental with FE results provides the true fracture strain as a function of stress triaxiality, which is regarded as a criterion of ductile fracture. Application of the developed stress-modified fracture strain to failure prediction of gas pipes made of API X65 steel with various types of defects is discussed.