• Title/Summary/Keyword: Transmission Formula

Search Result 156, Processing Time 0.027 seconds

Wireless Power Transmission between Two Metamaterial-Inspired Loops at 300 MHz

  • Kim, Gun-Young;Jung, Youn-Kwon;Lee, Bom-Son
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.4
    • /
    • pp.219-223
    • /
    • 2010
  • Based on a provided closed-form wireless power transmission (WPT) efficiency formula, which may be used for any value of load, we have analyzed the WPT efficiencies between two metamaterial-inspired loop antennas in various aspects. Due to the modeling based on low frequency circuit theory, the provided formula at the center resonant frequency has been found to be accurate until when the distance between the two loop antennas increases to 15 cm (about $\lambda_0/6$ at 300 MHz). When the two loops get closer, the resonant frequency has been found to split into two in theory, simulations, and measurements. The EM-simulated and measured efficiencies at new resonant frequencies are 60.9 % and 46.3 %, respectively, at d=15 cm. With two extra rings around the loops, the maximum efficiency is enhanced to 93.7 % at d=15 cm. The effect of the additional two rings is about 30 %.

Analysis of the Power for a Decanter-Type Centrifuge (II) - Total Power and the Power-Transmission Mechanism - (Decanter형 원심분리기의 동력 계산 (II) - 총동력과 동력전달 기구 -)

  • Suh, Yong-Kweon;Han, Geun-Jo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.7
    • /
    • pp.938-947
    • /
    • 2003
  • In this paper, we derived the formula for estimating the power of the electric motors needed to operate the Decanter-type centrifuge. In the derivation of the formula the sludge-removal torque is to be supplied from the formula derived in the first paper. The intricate nature of the transmission mechanism in the planetary gear trains of the sludge-removal power and torque has been clarified in this second paper. In particular we considered two-motor system, where the main motor drives the machine while the differential-speed control motor plays the role of braking in adjusting the differential speed. Sample calculation for the specific design treated in the first paper showed that the selection criterion for the main motor depends on the lower limit of the differential speed; when the lower limit is set low, it should be selected based on the steadily operating power, while it should be selected based on the starting power when the lower limit is set high. The total power required by both the main motor and the differential-speed control motor increases as the differential speed is decreased. It is suggested that the power loss in the differential-speed control motor could be minimized by attaching an electric generator to it.

Analysis of Primary and Secondary Thrust of a Metal Belt CVT Part I : New Formula for Speed Rtio-Torque-Thrust Relationship Considering Band Tension and Block Compression (금속벨트 CVT 의 구동 및 종동 드러스트 해석 Part I : 밴드 장력과 블록 압축력을 고려한 새로운 변속비-토크-트러스트 관계식)

  • 이희라;김현수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.8
    • /
    • pp.132-142
    • /
    • 1999
  • In this paper, a new formula for primary and secondary thrust of metal belt CVT is proposed considering variation of band tension, block compression and active arc for each of the primary and secondary pulleys. For the secondary thrust, effective friction coefficient is introduced considering the effect of flange deflection. Nondimensional primary and secondary thrust of the metal belt CVT by the new formula agree well with the experimental results except for low torque range, $0\;<\;{\lambda}\;<\;0.2$ at speed ration i = 1.0. The new formula can be used in design of the primary and secondary thrusts control system for the metal belt CVT.

  • PDF

Coordinate and Length of Straight Transmission Line Minimally connecting X-Y axis via a Specific Point (특정지점을 경유하며 X-Y 축을 최단거리로 연결하는 전선로의 길이 산정)

  • Lee, Sang-Joong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.9
    • /
    • pp.65-70
    • /
    • 2015
  • Minimal line length enables low-cost construction of the transmission lines and low-loss transportation of electric power. This paper presents a derivation to determine the coordinate and length of the straight line that minimally connects two perpendicular lines x-axis and y-axis via a specific point, using the optimization technique. The author shows a formula to obtain the minimal length, which is represented by the cube root of the coordinate given by the specific point. Case studies have been also discussed to prove the optimal solutions derived by the proposed formula.

Synthesis of Filtering Structures for Microstrip Active Antennas Using Orlov's Formula

  • Urbani, Fabio;Bilotti, Filiberto;Vegni, Lucio
    • ETRI Journal
    • /
    • v.27 no.2
    • /
    • pp.166-171
    • /
    • 2005
  • In this paper, a synthesis technique for nonuniform filtering structures to be employed in active integrated antenna layouts is presented. The idea is to suppress the higher harmonic contribution due to the presence of nonlinear components through a nonuniform transmission line properly designed via Orlov's synthesis formula. The theory presented is applied here to synthesize an amplifier-based active antenna layout for wireless local area network (WLAN) purposes working at 2.4 GHz. The numerical results presented show the capabilities of the proposed approach.

  • PDF

Power Flow and Efficiency of Input Coupled type CVT combined Differential Gear Unit (차동기어장치를 적용한 입력축 연결방식 무단변속기의 동력흐름 및 효율해석에 관한 연구)

  • Kim, Yeon-Su;Choi, Sang-Hoon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.11
    • /
    • pp.141-150
    • /
    • 2000
  • Continuously variable transmission(CVT) combined differential gear unit has many advantages, which are the decrease of CVT size, the increase of overall efficiency, the extension of speed ratio range, and the generation of geared neutral. It is known that such CVT can be classified into the input coupled type and the output coupled type according to the coupling location of continuously variable unit(CVU). In this paper, six different configurations of input coupled type CVT combined V-belt CVU and 2K-H I type differential gear unit are proposed. Some useful theoretical formula related to speed ratio, power flow and efficiency are derived and analyzed. The propriety of derived formula and theoretical analysis are proven by various experiments.

  • PDF

On the Starvation Period of CDF-Based Scheduling over Markov Time-Varying Channels

  • Kim, Yoora
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.8
    • /
    • pp.924-927
    • /
    • 2016
  • In this paper, we consider a cumulative distribution function (CDF)-based opportunistic scheduling for downlink transmission in a cellular network consisting of a base station and multiple mobile stations. We present a closed-form formula for the average starvation period of each mobile station (i.e., the length of the time interval between two successive scheduling points of a mobile station) over Markov time-varying channels. Based on our formula, we investigate the starvation period of the CDF-based scheduling for various system parameters.

A Numerical Study of 1-D Surface Flame Spread Model - Based on a Flatland Conditions - (산불 지표화의 1차원 화염전파 모델의 수치해석 연구 - 평지조건 기반에서 -)

  • Kim, Dong-Hyun;Tanaka, Takeyoshi;Himoto, Keisuke;Lee, Myung-Bo;Kim, Kwang-Il
    • Fire Science and Engineering
    • /
    • v.22 no.2
    • /
    • pp.63-69
    • /
    • 2008
  • The characteristics of the spread of a forest fire are generally related to the attributes of combustibles, geographical features, and meteorological conditions, such as wind conditions. The most common methodology used to create a prediction model for the spread of forest fires, based on the numerical analysis of the development stages of a forest fire, is an analysis of heat energy transmission by the stage of heat transmission. When a forest fire breaks out, the analysis of the transmission velocity of heat energy is quantifiable by the spread velocity of flame movement through a physical and chemical analysis at every stage of the fire development from flame production and heat transmission to its termination. In this study, the formula used for the 1-D surface forest fire behavior prediction model, derived from a numerical analysis of the surface flame spread rate of solid combustibles, is introduced. The formula for the 1-D surface forest fire behavior prediction model is the estimated equation of the flame spread velocity, depending on the condition of wind velocity on the ground. Experimental and theoretical equations on flame duration, flame height, flame temperature, ignition temperature of surface fuels, etc., has been applied to the device of this formula. As a result of a comparison between the ROS(rate of spread) from this formula and ROSs from various equations of other models or experimental values, a trend suggesting an increasing curved line of the exponent function under 3m/s or less wind velocity condition was identified. As a result of a comparison between experimental values and numerically analyzed values for fallen pine tree leaves, the flame spread velocity reveals a prediction of an approximately 10% upward tendency under wind velocity conditions of 1 to 2m/s, and of an approximately 20% downward tendency under those of 3m/s.

A Study on Implementation for the PCB Design Simulator (PCB 디자인 시뮬레이터 구현에 관한 연구)

  • 김현호;우경환;이천희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.296-296
    • /
    • 2000
  • This paper describes the features of a transmission line and a wiring, and a design rule based on a demanded condition for a wiring. Like as the simulation of a circuit, by tracking the wiring path among parts that are disposed on PCB, we analyze the feature of the corresponding wiring using the design formula and rule. We implement a signal integrity simulator, which is capable of electrical and electronic simulation for the feature of a wiring signal and the corresponding signal, and the results are demonstrated.

  • PDF

Calculation of Electric Field and Magnetic Flux Density under 3-Phase Power Lines (3상 전력선로하의 전계 및 자속밀도 계산)

  • Lee, Y.S.;Park, J.E.;Noh, I.S.;Kang, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.439-441
    • /
    • 2003
  • In this study the formula of electro magnetic fields under 3-phase power lines with vertical or horizontal line-configurations were deduced and the effect of the earth was considered in the formula. Using the formula the electric field and the magnetic flux density under distribution and transmission lines constucted currently in our country were calculated and the components of each field were investigated with horizontal distance from tower and height above the earth.

  • PDF