• Title/Summary/Keyword: Toluene Recovery

Search Result 79, Processing Time 0.028 seconds

Energy Recovery via Pyrolysis of Waste Tire Rubber : Desulfurization Effect of Pyrolysis Oil by Adding Waste Polypropylene (폐타이어의 열분해를 통한 에너지화 : 폐폴리프로필렌 첨가 시 열분해 오일의 탈황 효과)

  • Jeong, Jaeyong;Lee, Uendo;Chang, Wonseok;Oh, Munsei;Jeong, Soohwa
    • Journal of Energy Engineering
    • /
    • v.26 no.3
    • /
    • pp.97-104
    • /
    • 2017
  • In this study, waste tire rubbers were pyrolyzed in a lab-scale pyrolysis plant equipped with a fluidized bed reactor in a temperature ranges of $450-650^{\circ}C$. The main object of this work is to investigate the properties of pyrolysis oil with reaction temperatures and the behavior of sulfur in the products when waste polypropylene was added for co-pyrolysis. The maximum yield of oil was about 52wt.% at the reaction temperature of $456^{\circ}C$. From GC-MS analysis, the pyrolysis oils consisted mainly of limonene, toluene, xylene, styrene, trimethylbenzene, methylnaphthalenes and some heteroatom(sulfur and nitrogen)-containing compounds. The addition of waste polypropylene resulted in decrease in sulfur contents of the pyrolysis oils.

Study on Oil Production from Pyrolysis of Mixed Plastic Waste Using Multidimensional Chromatography (Multidimensional Chromatography/Mass Spectrometry를 이용한 혼합 폐플라스틱의 열분해 오일 특성 평가에 관한 연구)

  • 김석완
    • Journal of Environmental Science International
    • /
    • v.11 no.4
    • /
    • pp.375-382
    • /
    • 2002
  • The total hydrocarbon distribution of oil products obtained from the pyrolysis of four kinds of mixtures of polyethylene-polystyrene waste has been studied by multidimensional chromatography(high performance liquid chromatography followed by capillary gas chromatography)/mass spectrometry. Saturated, unsaturated and aromatic hydrocarbons in oil products were selectively pre-separated according to structural groups by HPLC and the weight fraction of each group was estimated by analysis of each component using GC-FID response factors. The hydrocarbon distribution of aliphatic fraction consists of $C_{5}$ to $C_{25}$ saturated and unsaturated hydrocarbons. And that of aromatics fraction consists of benzene, toluene, xylene, styrene, propenyl benzene, naphthalene, and some of derivatives. Pyrolysis temperature did not affect the ratio of total weight fraction of aliphatic over aromatic hydrocarbon distribution in case of PS only and PE-PS mixtures (1:1 and 1:4 wt. ratio) as a feed while affected the ratio of total wt. fraction in case of PE only. The optimal temperature for the maximum oil production was $600^{\circ}C$ for pyrolysis of PS and 1:1 and 1:4 mixtures of PE and PS. The optimal condition for aromatic recovery was $600^{\circ}C$ with 1:1 mixture of PE and PS. In this condition, aromatic was produced up to 90% of total oil product. The maximum yield of toluene, xylene, styrene, and propenyl benzene were 8.6, 8.9, 51.0 and 7.4% of feed for pyrolysis PS at $700^{\circ}C$, respectively. However, only 1.3% naphthalene was recovered at $700^{\circ}C$ with 1:1 PE:PS(by wt.).

Preparation and Property of POSS-Based Organic-Inorganic Hybrid Filler and Polyamide Thermoplastic Elastomer (PA-TPE)/POSS Nanocomposite (POSS 기반 유-무기 하이브리드 충전제와 폴리아미드계 TPE로 이루어진 나노복합체의 제조 및 특성)

  • Han, Jae Hee;Kim, Hyung Joong
    • Polymer(Korea)
    • /
    • v.37 no.1
    • /
    • pp.34-40
    • /
    • 2013
  • Commercially available polyamide thermoplastic elastomer (PA-TPE) was blended with hybrid filler which was prepared by means of the reaction between polyhedral oligomeric silsesquioxane (POSS) containing amine group and toluene diisocyanate (TDI)-caprolactam (CL) to explore the effect of blending the hybrid filler with the TPE. The chemical structure of the filler was identified by using FTIR and $^1H$ NMR. The composites, PA-TPE/POSS-(TDI+CL), which were the blends of TDI+CL modified POSS filler and PA-TPE up to 7 wt%, showed better elastic recovery delivered from lower tension setting compared to the PA-TPE and the PA-TPE/octaphenyl POSS blend. In addition the tensile strength and the initial modulus increased with increasing the hybrid filled content. Consequently it was assumed that the POSS-(TDI+CL) filler was a suitable material for enhancing strength and modulus without loss of elastic properties for the original PA-TPE.

Analytical Method for Dioxin and Organo-Chlorinated Compounds: (Ⅱ) Comparison and Extraction Methods of Dioxins from XAD-2 Adsorbent

  • 양정수;이성광;박영훈;이대운
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.6
    • /
    • pp.689-695
    • /
    • 1999
  • Supercritical fluid extraction (SFE), ultrasonic extraction (USE), and accelerated solvent extraction (ASE) were compared with the well known Soxhlet extraction for the extraction of polychlorinated biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins(PCDDs) from the XAD-2 resin which was used to adsorb PCDDs in the atmosphere. XAD-2 resin spiked with five PCDDs was chosen as a sample. The optimum conditions for the extraction of PCDDs by SFE were turned out to be the use of CO2 modified with 10% toluene at 100 ℃ and 350 atm, with 5 min static extraction followed by 20 min dynamic extraction. SFE gave a good extraction rate with good reproducibility for PCDDs ranging from 68 to 98%. The ultrasonic extraction of PCDDs from XAD-2 was investigated and compared with other extractions. A probe type method was compared with a bath type. Two extraction solvents, toluene and acetone were compared with their mixture. The use of their mixture in probe type, with 9 minutes of extraction time, was found to be the optimum condition. The average recovery of the five PCDDs for USE was 82-93%. Accelerated solvent extraction (ASE) with a liquid solvent, a new technique for sample preparation, was performed under elevated temperatures and pressures. The effect of tem-perature on the efficiency of ASE was investigated. The extraction time for a 10 g sample was less than 15 min, when the organic solvent was n-hexaneacetone mixture (1 : 1, v/v). Using ASE, the average recoveries of five PCDDs ranged from 90 to 103%. SFE, USE, and ASE were faster and less laborious than Soxhlet extraction. The former three methods required less solvent than Soxhlet extraction. SFE required no concentration of the solvent extracts. SFE and ASE failed to perform simultaneous parallel extractions because of instrumental limitations.

A Study on the Mortality in Oxygen and Toxic Gas Concentration According using Experimental Animals (실험동물을 이용 산소 및 유해가스 농도에 따른 치사율 연구)

  • Kim, Hyeon-Yeong
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.4
    • /
    • pp.18-25
    • /
    • 2013
  • It may occur health hazards or death by suffocation or acute poisoning in case of oxygen deficiency in ambient or exposure to harmful gas. As a part of accident prevention, we studied the change of activity and lethal dose by changing the concentration of several hazardous gas with inhalation exposure chamber and laboratory animals. We investigated the lethality and motility change during either the 4 hrs whole body exposure to oxygen, nitrogen, toluene, $H_2S$, CO and 48 recovery. As results, it is estimated that 5% oxygen concentration as lethal concentration and 5.5% as $LC_{50}$ (rat, 4 hrs) with statistics for dose-response. The results of lethality in oxygen deficient condition (approximately 6%), the lethalities were 40%, 20% with 20 ppm $H_2S$, 600 ppm CO respectively, and was not increased the lethality with 8% CO. Thus, it was confirmed that the $H_2S$, CO had influence to lethal dose, while toluene had low fluence.

The study on the analysis of α-naphthylamine in urine (요중 알파나프틸아민 분석에 관한 연구)

  • kim, Choon Sung;Roh, Jae Hoon;Bae, Mun Joo;Kim, Chi Nyon;Lim, Nam Gu;Won, Jong Uk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.1
    • /
    • pp.49-59
    • /
    • 1997
  • This study was performed to analyze the purity of technical grade ${\alpha}$-naphthylamine, to establish optimal analytical condition of ${\alpha}$-naphthylamine in urine and to determine the urine sample of workers exposed to ${\alpha}$-naphthylamine. The purity of technical grade ${\alpha}$-naphthylamine were $96.5{\pm}2.38%$, $94.1{\pm}0.97%$, $97.0{\pm}0.02%$ by gas chromatography-mass selective detector. To analyze ${\alpha}$-naphthylamine in urine, high performance liquid chromatography-electrochemical detector and gas chromatography-electron capture detector operating conditions have been optimized by preliminary expriment. In high performance liquid chromatography-electrochemical detector, the mobile phase was consisted of acetonitrile(35%) and water(65%), and the flow rate was maintained at 1.0ml per minute. Optimal detective condition was 9.0V(10nA/V) of electrochemical detector. The recovery of sep-pak treatment method was highly estimated as pretreatment of ${\alpha}$-naphthylamine in urine. The free amine was isolated by gas chromatography-electron capture detector after basic hydrosis, sep-pak treatment, toluene elution and HFBA(heptafluoro-butyric anhydride) derivatization of urine. The recovery of ${\alpha}$-naphthylamine in urine was $98.73{\pm}3.29%$ by gas chromatography-electron capture detector. The sensitivity was more higher than that of high performance liquid chromatography-electrochemical detector. Urinary ${\alpha}$-naphthylamine was detected in only one worker among nine workers. The level of ${\alpha}$-naphthylamine in urine was 6.42 ng/ml.

  • PDF

Reprocessing of simulated voloxidized uranium-oxide SNF in the CARBEX process

  • Boyarintsev, Alexander V.;Stepanov, Sergei I.;Kostikova, Galina V.;Zhilov, Valeriy I.;Chekmarev, Alexander M.;Tsivadze, Aslan Yu.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.7
    • /
    • pp.1799-1804
    • /
    • 2019
  • The concept of a new method, the CARBEX (CARBonate EXtraction) process, was proposed for reprocessing of spent uranium oxide fuel. The proposed process is based on use of water solutions of $Na_2CO_3$ or $(NH_4)_2CO_3$ and solvent extraction (SE) by the quaternary ammonium compounds for selective recovery and purification of U from the fission products (FPs). Applying of SE allows to reach high degree of purification of U from FPs. Carrying out the processes in poorly aggressive alkaline carbonate media leads to increasing safety of SNF's reprocessing and better selectivity of separation of lanthanides and actinides. Moreover carbonate reprocessing media allows to carry out a recycling and regeneration of reagents. We have been done laboratory scale experiments on the extraction components of simulated voloxidated spent fuel in the solutions of NaOH or $Na_2CO_3-H_2O_2$ and recovery of U from carbonate solutions by SE method using carbonate of methyltrioctylammonium in toluene. It was shown that the purification factors of U from impurities of simulated FPs reached values $10^3-10^5$. The received results support our opinion that CARBEX after the further development can become more safe, simple and profitable method of spent fuel reprocessing.

Determination of Organic Pollutants in Dyeing Wastewater (염색폐수 중의 유기오염물질 분석)

  • Yook, Keun-Sung
    • Analytical Science and Technology
    • /
    • v.10 no.5
    • /
    • pp.332-342
    • /
    • 1997
  • Fifteen volatile organic pollutants were spiked in blank water at the concentration of $20{\mu}g/L$ and analyzed with Purge and Trap and GC/MS. As a result, the overall mean recovery of 100% was obtained with a mean relative standard deviation of 3.6%. The method detection limits were in the range of $1.9{\sim}3.3{\mu}g/L$. In the wastewater analysis of Banwol dyeing comlex, 15 organic compounds were identified and three of these were quantified. Among the compounds identified, only trichloroethylene and tetrachloroethylene are regulated in wastewater by the Korea Ministry of Environment. But, the concentration of these two compounds were below the government allowance level.

  • PDF

Validation of an Extraction Method for the Determination of Airborne MWFs using Alternative Solvents (대체용매를 이용한 금속가공유 측정방법 타당성 평가)

  • Jeong, Jee Yeon;Baek, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.2
    • /
    • pp.91-100
    • /
    • 2006
  • The purpose of this study was to validate alternative method by using non-carcinogenic, and less toxic solvents than NIOSH analytical method 5524 for measuring the airborne MWFs in workplaces. In laboratory tests, the ETM solvents(mixture of same volume for ethyl ether, toluene, and ethanol) were selected. The alternative method of analyzing MWFs, referred to as the ETM solvent extraction method, showed 0.04 mg/sample as LOD, and 0.15 mg/sample as LOQ. The analytical precision (pooled CV, coefficient of variation) of the ETM solvent extraction method for analyzing the straight, soluble, semisynthetic, and synthetic metalworking fluid was 1.5%, 2.0%, 2.6%, 1.6%, respectively, which was similar to the precision (2.6%) of NIOSH analytical method (NIOSH 0500) for total dust. The analytical accuracy by recovery test, spiked mass calculated as extractable mass, was almost 100%. As the result of storage stability test, metalworking fluid samples should be stored in refrigerated condition, and be analyzed in two weeks after sampling. The 95% confidence limit of the estimated total standard error for the ETM solvent extraction method for analyzing the straight, soluble, semisynthetic, and synthetic metalworking fluid was ${\pm}12.6%$, ${\pm}12.5%$, ${\pm}14.0%$, and ${\pm}13.6%$, respectively, which satisfied the OSHA sampling and analytical criteria.

Solid-Phase Extraction of L-Muscone from Aqueous Samples with Amberlite XAD-4 for Gas Chromatographic Assay

  • Paik, Man-Jeong;Kim, Kyoung-Rae
    • Archives of Pharmacal Research
    • /
    • v.27 no.5
    • /
    • pp.539-543
    • /
    • 2004
  • An efficient analytical method was devised for the accurate L-muscone assay in aqueous samples. It involves solid-phase extraction of L-muscone in adsorption mode using XAD-4 as the sorbent and dichloromethane modified with 10% (v/v) methanol as the eluting solvent. The gas chromatographic analysis of the eluate residue dissolved in toluene on a DB-5MS capillary column provided complete resolution of L-muscone from the co-extracted interferences. The overall method showed excellent linearity ($r^2{\geq}$ 0.9994) in the range of 0.1 to 2.0 $\mu\textrm{g}$/mL with good intra- and inter-day precisions (% RSD = 2.5~7.3) and with high extraction recovery rates ($\geq$ 98.1 %). When the present method was applied to a L-muscone herbal drink product, the within-batch RE (%) in the labeled concentration (1.5 $\mu\textrm{g}$/mL) for the three randomly chosen bottles were -2.4, -1.3 and -3.3 with high precision (% RSD $\leq$ 3.1). The present method is considered to be suitable for quality control evaluation on liquid drinks and other complex formulations fortified with L-muscone.