• Title/Summary/Keyword: Tm3+

Search Result 2,032, Processing Time 0.026 seconds

The Luminescent Properities of Li and Tm Doped $ZnGa_2$$O_4$Phosphors (Li, Tm이 도핑된 $ZnGa_2$$O_4$형광체의 발광특성)

  • 김용태;류호진;박희동;최대규;이명진;정경원;전애경;윤기현
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.2
    • /
    • pp.112-116
    • /
    • 2001
  • 고상반응법에 의한 제조한 ZnGa$_2$O$_4$형광체에 Li 및 Tm 원소를 도핑함에 따른 발광특성을 조사하였다. 254nm 여기 하에서, 환원 처리된 ZnGa$_2$O$_4$형광체는 245nm에서 흡수피크와 380nm에서 발광피크를 나타내며, 이는 스피넬 구조에서 Ga$^{3+}$ 이온의 $^4$T$_2$$\longrightarrow$$^4$A$_2$천이에 기인한다. ZnGa$_2$O$_4$형광체에 있어서 Li 및 Tm을 도핑했을 경우가 도핑하지 않은 시료에 비해 발광강도 및 색순도가 개선되었으며, Li 및 Tm을 각각 0.1 mol, 0.01 mol 첨가했을 때 가장 우수한 발광강도 및 색순도 특성을 보였다.

  • PDF

The Convergent Effects of Oral Health Education Feedback Using QraycamTM (QraycamTM 활용한 구강보건교육 피드백의 융합적 효과)

  • Yeo, An-Na;Lee, Su-Young
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.3
    • /
    • pp.63-70
    • /
    • 2017
  • The purpose of this study was to evaluate the effects of oral health education feedback using $Qraycam^{TM}$. The middle school students 118 were divided into intervention group (59) and control group (59) subjects evaluated the dental plaque score using $Qraycam^{TM}$ after oral health education at baseline. Then, the $Qraycam^{TM}$ images view only sent to students and parents of the intervention group by text message. After 4 weeks both intervention group and control group were evaluated dental plaque by $Qraycam^{TM}$ re-taking. Then, they filled out the questionnaire. Both ${\Delta}R$ value and SPS(Simple Plaque Score) were statistically significant reduced in groups performed feedback(p<0.001). The oral health behavior, toothbrushing of intervention group was significantly higher compared to the control group(p<0.001). Also the importance of oral health was significantly higher in the intervention group compared to the control group(p<0.001). The effect of dental plaque reducing, toothbrushing time and subjective oral health importance were higher in the intervention group who received feedback using $Qraycam^{TM}$ image. Therefore it was expected to be able to utilize $Qraycam^{TM}$ image as a visual feedback tool of oral health education.

Evaluation of a rapid diagnostic kit "BIOLINE RSVTM" for the detection of respiratory syncytial virus (Respiratory Syncytial Virus 감염의 조기 진단 kit "바이오라인 알에스브이TM"의 평가)

  • Kim, So-Hee;Sung, Ji-Yeon;Yang, Mi-Ae;Eun, Byung-Wook;Lee, Jin-A;Choi, Eun-Hwa;Lee, Hoan-Jong
    • Pediatric Infection and Vaccine
    • /
    • v.14 no.1
    • /
    • pp.91-96
    • /
    • 2007
  • Purpose : This study was performed to evaluate a new rapid diagnostic kit (BIOLINE $RSV^{TM}$; Standard Diagnostics Inc., Yongin, Korea), a lateral-flow immunoassay, in the detection of respiratory syncytial virus (RSV) from the nasopharyngeal aspirates (NPA) of children with lower respiratory tract infections (LRTIs) in comparison with other diagnostic methods. Methods : Three hundred and nineteen NPAs were selected from a large pool of NPAs that had been obtained from children with LRTIs. All specimens had already been tested for RSV by culture and immunofluorescent (IF) test, and had been kept frozen. Tests with BIOLINE $RSV^{TM}$ were performed at least twice. All who conducted the experiments or interpreted the test results were blinded to the results of both culture and IF tests. Results : One hundred seven (97.3%) of 110 specimens that were positive for RSV by both culture and IF test, 29 (87.9%) of 33 that were positive by IF test only, 20 (76.9%) of 26 that were positive by culture only, and 140 (93.3%) of 150 that were negative by both methods were negative for RSV by BIOLINE $RSV^{TM}$. By combining the above results, the following 5 diagnostic values of BIOLINE $RSV^{TM}$ were determined in comparison with viral culture or IF test; sensitivity, 92.3% (156/169, 95% confidence interval [CI], 87.1-97.5%); specificity, 93.3% (140/150, 95% CI, 88.4-98.2%); positive predictive value, 94.0% (156/166, 95% CI, 89.5-98.5%); negative predictive value, 91.5% (140/143, 95% CI, 86.0-97.0%); and agreement, 95.9% (306/319, 95% CI, 92.1-99.7%), respectively. Conclusion : This study revealed that BIOLINE $RSV^{TM}$ demonstrated good sensitivity and specificity for the detection of RSV antigen from NPAs of children with LRTIs. Because of simple methods and quick results, this test may be useful for the diagnosis of RSV infection during the epidemic periods.

  • PDF

Antibacterial Properties of Pit and Fissure Sealant Containing S-PRG filler on Streptococcus mutans (S-PRG filler를 포함한 치면열구전색제의 Streptococcus mutans에 대한 항미생물 특성에 관한 연구)

  • An, Jinseon;Park, Howon;Seo, Hyunwoo;Lee, Siyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.42 no.4
    • /
    • pp.302-311
    • /
    • 2015
  • The purpose of this study was to evaluate the antibacterial properties of a sealant containing S-PRG filler compared to those of two contemporary commercial sealants to determine the inhibition of bacterial growth in broth culture and biofilm formation using the CDC Biofilm Reactor. The BeautiSealant containing S-PRG filler, the fluoride releasing Clinpro$^{TM}$ sealant, which are known to have higher antibacterial effects, and the non-fluoride releasing Concise$^{TM}$ sealant were selected for this study. A Streptococcus mutans culture in BHI broth without sealant served as a negative control in the planktonic growth inhibition test. As a result, bacterial growth was inhibited in all three sealant groups compared to that in the control. The Clinpro$^{TM}$ sealant showed a significantly reduced number of CFUs compared to those of the BeautiSealant and Concise$^{TM}$ sealants. However, no significant difference was detected between the BeautiSealant and Concise$^{TM}$ sealants. The Clinpro$^{TM}$ sealant significantly decreased biofilm formation compared to that by the BeautiSealant and Concise$^{TM}$ sealants. No significant difference was observed between the BeautiSealant and Concise$^{TM}$ sealants. In conclusion, the sealant containing S-PRG filler had a less potent anti-bacterial property and increased biofilm formation capacity compared to those of the fluoride releasing Clinpro$^{TM}$ sealant.

AN EXPERIMENTAL STUDY ON THE MICROTENSILE BONDING STRENGTH OF DENTIN TREATED BY $CARISOLV^{TM}$ ($Carisolv^{TM}$ 에 의한 우식제거후 Microtensile Bonding Strength에 관한 연구)

  • Baik, Byeong-Ju;Kwon, Byoung-Woo;Kim, Jae-Gon;Cheon, Cheol-Wan
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.3
    • /
    • pp.389-396
    • /
    • 2002
  • The purpose of this study was to compare the microtensile bonding strength of chemomechanically excavated dentin($Carisolv^{TM}$) to conventional caries removal(bur). The following adhesive systems were used; AB: All-Bond 2(3M, USA), PB: Prime & Bond 2.1(Dentsply, DE), AQ: AQ Bond(sun medical, Japan). 42 human molars with occlusal caries were assigned to 6 groups. Sequential caries removal was controlled with laser fluorescence. Each group was devided as follows; group A, B, C were $Carisolv^{TM}$ applied, group D,E,F were bur used. In group A and D, AB was used as a dentin adhesive. group B,E and group C,F was AQ and AQ was used each. The cavity was filled with composite resin(Z-100). The specimens were sectioned vertically into multiple serial 0.7 mm thick slabs. And then those slabs were sectioned into rectangular parts under 0.7 mm width. Finally 0.7-1.0 mm a right hexahedron shape stick become. Microtensile bonding test was carried out with testing apparatus at cross-head speed of $0.5\;mm/min^{-1}$ and fractured surfaces were observed with scanning electron microscope(JSM-6400, Jeol, Japan). The obtained results were summarized as follows ; 1. In the group of caries removal with $Carisolv^{TM}$, micro-tensile bonding strength decreased to $75.8{\sim}80$ percent of bur used group. 2. In the group of caries removal with $Carisolv^{TM}$, decreased degree of micro-tensile bonding strength is not so different in 3 kinds of dentin adhesives(p<0.05). 3. In the group of caries removal with $Carisolv^{TM}$, microtensile bonding strength of AB, PB, AQ was 32.6MPa(2.4), 30.1Mpa (1.8), 21.2Mpa(1.9). 4. In the group of caries removal with Bur and $Carisolv^{TM}$, microtensile bonding strength of AQ was significantly lower than that of AB and PB(p<0.01).

  • PDF

THE EFFECTS OF THERMOCONDENSATION TECHNIQUE USING SYSTEM BTM ON THE PERIODONTIUM (System BTM를 이용한 열가압 충전시의 치주인대내에 미치는 영향)

  • Kim, Jae-Wook;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.366-378
    • /
    • 1998
  • Thermocondensation root canal filling technique have been used to fill accessary canals or to obtain homogeneous root caral fillings. But these thermocondensation technique inevitably produce heat in the canal which can be transmitted through the dentin and cementum and consequently damage periodontal ligamental cells and osteoblasts. In this study, System $B^{TM}$(Analytic technology, WA.D.S.A.) was used to evaluate the reaction of periodontal ligament tissue to "Continous Wave condensation technique" introduced by Buchanan, and the transmitted root surface temperature was measured according to measured root thicknesses. 12 Mandibular incisors of two adult dogs were used for the experiment. 6 controls were filled by lateral condensation technique with sealer.3 specimens were apically filled by Continuous Wave technique at $200^{\circ}C$ for 5 seconds and remaining 3 specimens were additionally backfilled using System $B^{TM}$(Analytic technology, WA.D.S.A.) was used to evaluate the reaction of periodontal ligament tissue to "Continous Wave condensation technique" introduced by Buchanan, and the transmitted root surface temperature was measured according to measured root thicknesses. 12 Mandibular incisors of two adult dogs were used for the experiment. 6 controls were filled by lateral condensation technique with sealer.3 specimens were apically filled by Continuous Wave technique at $200^{\circ}C$ for 5 seconds and remaining 3 specimens were additionally backfilled using System $B^{TM}$ at $100^{\circ}C$ for 20 seconds. Six weeks later, the dogs were sacrificed and the teeth stained with Hematoxylin and Eosin for histologic examination. 6 extracted human teeth were used to measure the transmitted temperature. After cutting off the crown, the canals were prepared and divided into 3 groups with root thickness of 1.5mm, 1.0mm, 0.5mm, 2 teeth in each group. Inside each root canal, System $B^{TM}$ was heated as with the temperature for the apically condensed and the back filled group, and the transmitted heat was measured on the external surface of the root. The temperature of System $B^{TM}$ heat spreader at $200^{\circ}C$ and $100^{\circ}C$ was also measured at root temperature. It can be concluded as follows: 1. In the thin area (200-$250{\mu}m$) of the root, root resorption could be seen even with heating at $200^{\circ}C$ for 5 seconds. 2. When the spreader was heated at $200^{\circ}C$ for 5 seconds and additionally at $100^{\circ}C$ for 20 seconds for backfill, all teeth showed root resorption regardless of their root thickness. 3. The transmitted external root surface temperature was higher as the root thickness decreased and as the heating time increased. In the thermocompaction technique using System $B^{TM}$, the spreader should be heated for the minimal time and used only in the apical area. The heated spreader shouldn't inserted to the binding point of the canal and backfilling should be done with other means of minimally heated gutta percha technique.

  • PDF

Magnetism of BN Nanotubes with Transition Metal Substitution (전이금속이 치환된 BN 나노튜브의 자성)

  • Jang, Y.R.;Park, Jin-Woo;Yu, B.D.
    • Journal of the Korean Magnetics Society
    • /
    • v.19 no.2
    • /
    • pp.43-46
    • /
    • 2009
  • The magnetic and structural properties of the (8, 0) BN nanotubes with transition metals (TM) of Fe, Co, or Ni substitution for B or N were investigated using a first-principles calculation. It was found that TM substitution makes the cross section being distorted and the bond length TM-B or TM-N being longer than that of the original B-N one. The magnetic moment is larger for the TM substitution for B than one for N, and it is mainly due to the 3d electrons of TM atoms.

Polarization Splitter Made of the Side-Polished Fiber Coupler Including a thin Metal Intermediate Layer (얇은 중간 금속층을 포함한 측면 연마 광섬유 결합기를 이용한 편광 분리기)

  • 김광택;이준옥
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.9
    • /
    • pp.651-657
    • /
    • 2003
  • We have demonstrated an in-line polarization splitter based on a side-polished fiber coupler including a thin metal intermediate layer. The experimental results revealed that the metal layer with proper thickness prevents TE polarization component from optical coupling between two contacted side-polished fibers, whereas it allows TM polarization component to the coupling. The design and fabrication techniques about the polarization splitter exploiting the side-polished fibers have been presented. The fabricated polarization splitter exhibited 18dB and 23dB of isolation ratio for TE polarization and TM polarization, respectively. The measured insertion loss for TE and TM polarization was 0.7dB and 1.3dB, respectively.