• Title/Summary/Keyword: Tl-201 Scan

Search Result 21, Processing Time 0.036 seconds

Left Ventricular Ejection Fraction Determined by Gated Tl-201 Perfusion SPECT and Quantitative Software (게이트 Tl-201 관류 SPECT와 Cedars 소프트웨어를 이용하여 측정한 좌심실 구혈률)

  • Hyun, In-Young;Kim, Sung-Eun;Seo, Jeong-Kee;Hong, Eui-Soo;Kwan, Jun;Park, Keum-Soo;Lee, Woo-Hyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.3
    • /
    • pp.222-227
    • /
    • 2000
  • Purpose: We compared estimates of ejection fraction (EF) determined by gated Tl-201 perfusion SPECT (g-Tl-SPECT) with those by gated blood pool (GBP) scan. Materials and Methods: Eighteen subjects underwent g-Tl-SPECT and GBP scan. After reconstruction of g-Tl-SPECT, we measured EF with Cedars software. The comparison of the EF with g-Tl-SPECT and GBP scan was assessed by correlation analysis and Bland Altman plot. Results: The estimates of EF were significantly different (p<0.05) with g-Tl-SPECT ($40%{\pm}14%$) and GBP scan ($43%{\pm}14%$). There was an excellent correlation of EF between g-Tl-SPECT and GBP scan (r=0.94, p<0.001). The mean difference of EF between GBP scan and g-Tl-SPECT was +3.2% Ninety-five percent limits of agreement were ${\pm}9.8%$. EF between g-Tl-SPECT and GBP scan were in poor agreement. Conclusion: The estimates of EF by g-Tl-SPECT was well correlated with those by GBP scan. However, EF of g-Tl-SPECT doesn't agree with EF of GBP scan. EF of g-Tl-SPECT can't be used interchangeably with EF of GBP scan.

  • PDF

Is $^{201}Tl-^{99m}Tc$-Subtraction Scan an Accurate Diagnostic Method to Detect Parathyroid Mass? ($^{201}Tl/^{99m}Tc$ 감영스캔으로 부갑상선종괴를 얼마나 찾을 수 있는가?)

  • Yang, Hyung-In;Kim, Deog-Yoon;Kim, Kwang-Won;Choi, Young-Kil
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.31-36
    • /
    • 1994
  • We studied 65 patients with hypercalcemia who had heed performed $^{201}Tl/^{99m}Tc$ subtraction scan, 21 of them were confirmed as parathyroid tumor (19 adenoma, 2 carcinoma). The diagnostic sensitivity of $^{201}Tl/^{99m}Tc$ subfraction scan for detecting parathyroid mass was 90.5%, specificity was 97.6%, ultrasonography was 80.6%, 58.8%, respectively. The causes of two false negative cases were relatively small size ($1.5{\times}1{\times}0.8cm$) compared to remainig cases and poor thallium uptake due to cystic necrosis of parathyroid adenoma. The one false positive case was non-functioning thyroid nodule. $^{201}Tl/^{99m}Tc$ subtraction scan was simple, effective diagnostic tool and superior to ultrasonography for evaluating the parathyroid mass with high sensitivity and specificity.

  • PDF

Thallium-201 Scan in Bone and Softtissue Sarcoma - Comparison with Tc-99m-MIBI and Tc-99m-MDP Scan - (악성 골 및 연부조직 종양에서 Tl-201 SCAN의 진단적 효능 - Tc-99m-MIBI 및 Tc-99m-MDP scan과의 비교 -)

  • Shin, Duk-Seop;Cho, Ihn-Ho;Ahn, Jong-Chul;Ahn, Myun-Hwan;Lee, Sang-Ho
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.2 no.1
    • /
    • pp.1-7
    • /
    • 1996
  • PURPOSE : The purpose of this study is to know the ability of detecting malignant tumor tissue by Tl-201 scan, and to compare with that of Tc-99m-MIBI and Tc-99m-MDP scan. MATERIAL AND METHODS : Between February 1994 and December 1995,38 unselected patients with various bone pathologies were studied prospectively. Eighteen had malignant bone and soft tissue pathologies, while twenty had benign. All patients were studied with Tl-201, Tc-99mMIBI and Tc-99m-MDP scan prior to surgical biopsy. PICKER Prism 2000 gamma camera with high resolution parallel hole collimator was used for scanning. To avoid the interaction of isotope, the early(30min.) and delayed phase(3hrs.) of Tl-20l scan was performed first and Tc-99m-MIBI scan was performed after 30 minutes, and then Tc-99m-MDP scan 48 hours later. The scan images were visually evaluated by a blinded nuclear medicine physician. We could find true positive, true negative, false positive and false negative by the comparison of results with those of biopsy. We calculated positive and negative predictive value(%), sensitivity(%), specificity(%) and diagnostic accuracy(%) of each scan. RESULT : The results of each scan were 85.7, 100, 100, 85, 92.1% in Tl-201, 81, 94.1, 94.4, 80, 86.8% in Tc-99m-MIBI and 50, 66.7, 88.9, 20, 52.6% in Tc-99m-MDP scan. As a conclusion, Tl-201 scan was the most specific and accurate method for detecting malignant tumor tissue. Tc-99m-MIBI scan was also good for malignant tumor searching. CONCLUSION : With our results, we can use Tl-201 scan to differentiate benign from malignant tumor, and to evaluate the response of preoperative chemotherapy or radiotherapy, and to determine the residual tumor or local recurrence. For the better result, we need to have a more detail information about false positive cases and a more objective and quantitative reading technique.

  • PDF

Comparison of Ga-67, Tl-201 and Tc-99m MIBI Imaging in Lymphoma Patients (림프종 환자에서의 갈륨, Tl-201 그리고 Tc-99m MIBI 섭취의 비교)

  • Chun, Kyung-Ah;Cho, Ihn-Ho;Won, Kyu-Chang;Lee, Kyung-Hee;Lee, Hyung-Woo;Hyun, Myung-Soo;Lee, Jae-Tae;Lee, Kyu-Bo
    • Journal of Yeungnam Medical Science
    • /
    • v.19 no.2
    • /
    • pp.107-115
    • /
    • 2002
  • Purpose: Ga-67 scintigraphy has been used for the evaluation of tumors, especially lymphoma. Recently, Tl-201 and Tc-99m MIBI were also used to tumor imaging. Tl-201 and Tc-99m MIBI had better physiologic characteristics than Ga-67, so we studied 32 biopsy proven lymphoma patients (male 24, female 8, mean age 46 years) with Ga-67, Tl-201 or Tc-99m MIBI and compared the scan findings. Materials and Methods: Twenty-three of 32 patients were injected 74-111 MBq (2-3 mCi) of Tl-201, before chemotherapy and imaged with dual-headed SPECT (Prism 2000, Picker, USA) at 30 minutes after injection. Delayed images were obtained after 3 hr in 8 patients. Twenty seven of 32 patients were injected 740 MBq (20 mCi) of Tc-99m MIBI and imaged at 30 minutes after injection. 111-185 MBq (3-5 mCi) of Ga-67 was injected in 12 patients and imaged at 48 and 72 hours after injection. Twenty eight patients were diagnosed as non-Hodgkin's lymphoma and others were Hodgkin's lymphoma. Results: Twenty patients were positive on Tl-201 scan and 3 patients showed negative findings. One of these 3 patients, Tc-99m MIBI and Ga-67 scan were positive. Twenty two patients were positive on Tc-99m MIBI scan and 5 patients showed negative findings. One of these 5 patients, Tl-201 was positive and 2 were positive on Ga-67 scan. Ten of 12 patients showed positive findings on Ga-67 scan. The sensitivity of these agents were 83.3%, 87.0% and 81.5% for Ga-67, Tl-201 and Tc-99m MIBI, respectively. The sensitivity was highest in Tl-201 scan, but there were no significant differences among three tests. In this study, there was no significant difference of uptake ratios between early and delayed images of Tl-201. Conclusion: Scintigraphy with Tl-201 and Tc-99m MIBI in lymphoma patients have similar sensitivity with Ga-67.

  • PDF

The Influence Evaluation of $^{201}Tl$ Myocardial Perfusion SPECT Image According to the Elapsed Time Difference after the Whole Body Bone Scan (전신 뼈 스캔 후 경과 시간 차이에 따른 $^{201}Tl$ 심근관류 SPECT 영상의 영향 평가)

  • Kim, Dong-Seok;Yoo, Hee-Jae;Ryu, Jae-Kwang;Yoo, Jae-Sook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.67-72
    • /
    • 2010
  • Purpose: In Asan Medical Center we perform myocardial perfusion SPECT to evaluate cardiac event risk level for non-cardiac surgery patients. In case of patients with cancer, we check tumor metastasis using whole body bone scan and whole body PET scan and then perform myocardial perfusion SPECT to reduce unnecessary exam. In case of short term in patients, we perform $^{201}Tl$ myocardial perfusion SPECT after whole body bone scan a minimum 16 hours in order to reduce hospitalization period but it is still the actual condition in which the evaluation about the affect of the crosstalk contamination due to the each other dissimilar isotope administration doesn't properly realize. So in our experiments, we try to evaluate crosstalk contamination influence on $^{201}Tl$ myocardial perfusion SPECT using anthropomorphic torso phantom and patient's data. Materials and Methods: From 2009 August to September, we analyzed 87 patients with $^{201}Tl$ myocardial perfusion SPECT. According to $^{201}Tl$ myocardial perfusion SPECT yesterday whole body bone scan possibility of carrying out, a patient was classified. The image data are obtained by using the dual energy window in $^{201}Tl$ myocardial perfusion SPECT. We analyzed $^{201}Tl$ and $^{99m}Tc$ counts ratio in each patients groups obtained image data. We utilized anthropomorphic torso phantom in our experiment and administrated $^{201}Tl$ 14.8 MBq (0.4 mCi) at myocardium and $^{99m}Tc$ 44.4 MBq (1.2 mCi) at extracardiac region. We obtained image by $^{201}Tl$ myocardial perfusion SPECT without gate method application and analyzed spatial resolution using Xeleris ver 2.0551. Results: In case of $^{201}Tl$ window and the counts rate comparison result yesterday whole body bone scan of being counted in $^{99m}Tc$ window, the difference in which a rate to 24 hours exponential-functionally notes in 1:0.114 with Ventri (GE Healthcare, Wisconsin, USA), 1:0.249 after the bone tracer injection in 12 hours in 1:0.411 with 1:0.79 with Infinia (GE healthcare, Wisconsin, USA) according to a reduction a time-out was shown (Ventri p=0.001, Infinia p=0.001). Moreover, the rate of the case in which it doesn't perform the whole body bone scan showed up as the average 1:$0.067{\pm}0.6$ of Ventri, and 1:$0.063{\pm}0.7$ of Infinia. According to the phantom after experiment spatial resolution measurement result, and an addition or no and time-out of $^{99m}Tc$ administrated, it doesn't note any change of FWHM (p=0.134). Conclusion: Through the experiments using anthropomorphic torso phantom and patients data, we found that $^{201}Tl$ myocardium perfusion SPECT image later carried out after the bone tracer injection with 16 hours this confirmed that it doesn't receive notable influence in spatial resolution by $^{99m}Tc$. But this investigation is only aimed to image quality, so it needs more investigation in patient's radiation dose and exam accuracy and precision. The exact guideline presentation about the exam interval should be made of the validation test which is exact and in which it is standardized about the affect of the crosstalk contamination according to the isotope use in which it is different later on.

  • PDF

Clinical Study of Simultaneous Acquisition Rest 99mTc-sestaMIBI/Stress 201Tl Dual-Isotope Myocardial Perfusion Imaging with a Solid-State Dedicated Cardiac Gamma Camera (반도체 심근 전용 감마카메라를 이용한 Rest 99mTc-sestaMIBI/Stress201Tl 이중 동위원소 심근 관류 동시 스캔에 관한 임상적 고찰)

  • Bahn, Young-Kag;Kim, Dong-Heui;Choi, Yong-Hoon;Kang, Chun-Koo;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.88-91
    • /
    • 2018
  • Purpose The purpose of this study is to investigate the simultaneous dual isotope (SDI) myocardial perfusion scan that can be performed in a short time using a semiconductor gamma camera. Materials and Methods Of the 86 patients who underwent Rest/Stress $^{99m}TC$-sestaMIBI 1-day myocardial perfusion scan and Rest $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ simultaneous dual isotope myocardial perfusion scan using a heart-only gamma camera, the test results were the same, 36 patients who did not show any change in the clinical outcome. Quantitative values were statistically analyzed using a QPS program to confirm the correlation between the images of the two examinations. Results Rest/Stress $^{99m}TC$-sestaMIBI simultaneous dual myocardial perfusion scans and $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ double-isotope myocardial perfusion scans were analyzed for Summed score. The $R^2$ value of the Rest summed score (RSS) was 0.91 and the $R^2$ value of the stress summed score (SSS) was 0.71. Conclusion The $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ simultaneous dual isotope scan confirmed its correlation with the previous day's test. The $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ simultaneous dual isotope scan can be completed in approximately 30minutes. It maybe clinically useful for patients who need short examination time such as emergency patients or elderly patients.

Accuracy of Ventricular Volume and Ejection Fraction Measured by Gated Tl-201 Perfusion Single Photon Emission Tomography (심전도 게이트 심근관류 Tl-201 SPECT로 측정된 좌심실 기능 및 좌심실 용적의 정확성)

  • Pai, Moon-Sun;Moon, Dae-Hyuk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.2
    • /
    • pp.94-99
    • /
    • 2005
  • Electrocardiogram-gated single photon omission computed tomography (SPECT) provides valuable information in the assessment of both myocardial perfusion and ventricular function. Tl-201 is a suboptimal isotope for gating. Tl-201 images are more blurred compared with Tc-99m tracers due to the increased amount of scattered photons and use of a smooth filter. The average myocardial count densities are approximately one-half those of conventional technetium tracers. However, Tl-201 is still widely used because of its well-established utility for assessing myocardial perfusion, viability and risk stratification. Gated SPECT with Tl-201 enables us to assess both post-stress and rest left ventricular volume and function. Previous studies with gated Tl-201 SPECT measurements of ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV) have shown high correlation with first-pass radionuclide angiography, gated blood pool scan, Tc-99m-MIBI gated SPECT, contrast ventriculography, echocardiography, and 3-dimensional magnetic resonance imaging. However, problems related to these studies include few agreement data of EDV and ESV, use of a reference method that is likely to have the same systemic errors (gated Tc-99m-MIBI SPECT), and other technical factors related to the count density of gated SPECT. With optimization of gated imaging protocols and more validation studies, gated Tl-201 SPECT would be an accurate method to provide perfusion and function information in patients with coronary artery disease.

Usefulness of Flow Composite Image in Raynaud Scan ($^{201}Tl$) ($^{201}Tl$을 이용한 레이노 검사에서 동적 Composite 영상의 유용성)

  • Kim, Dae-Yeon;Shin, Gyoo-Seol;Oh, Eun-Jung;Kim, Gun-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.101-104
    • /
    • 2010
  • Purpose: Raynaud scan is divided to flow, blood pool and local-delay image. Usually, we evaluate comparison through blood pool and local-delay image. We will evaluate about usability when comparative observe blood image and local-delay image in Raynaud scan that used $^{201}Tl$ as making flow image to one sheet of images. Materials and Methods: We have selected 29 Raynaud phenomenon patients aged 14~68 years who visited department of vascular surgery between Feb. 2008 and Aug. 2009. An intravenous injection $^{201}Tl$ of 111 MBq (3 mCi) to opposite side diagonal line limbs above an internal auditing department. Equipment used Philips gamma camera forte A-Z, and collimator used LEHR. Matrix size set up to each $64{\times}64$, $128{\times}128$, $256{\times}256$ and zoom factor used to full field. Protocol of dynamic is 2 second to 155 frames. Blood pool and delay count to 300 second. We set up ROI by a foundation to data acquired in PEGASYS processing program. Each results were analyzed with the SPSS 12.0 statistical software. Results: Each averages of count ratio (Rt / Lt) to have been given at composite image, a blood pool image, delay images analyzed at Raynaud phenomenon patients is $1.25{\pm}0.39$, $1.20{\pm}0.33$, $1.11{\pm}0.17$. The sample analysis results of blood pool image and delay image contented itself with p<0.029. Also, there don't have been each difference, and blood pool image, delay image regarding composite image was able to know. Conclusion: We were able to give help for comparison to evaluate a blood pool image and a local delay image at the Raynaud scan which used $^{201}Tl$ while making a flow image to one sheet image. Identification to be visual too was possible. If you are proceeded a researcher that there was further depth, you are more appropriate for, and you may get useful information.

  • PDF

Thallium-201 SPECT in the Evaluation of Postoperative Tumor Recurrence on the Chest Wall in Lung Cancer (폐암 수술 후 흉벽의 종양 재발 검출에 있어 Tl-201 폐 SPECT의 유용성)

  • Ryu, Young-Hoon;Kim, Hyung-Jung;Ahn, Chul-Min;Kim, Se-Kyu;Paik, Hyo-Chae;Lee, Doo-Yun;Chung, Kyung-Young;Yune, Min-Jin;Park, Sang-Jung;Moon, Sung-Wook;Kim, Sang-Jin;Lee, Jong-Doo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.5
    • /
    • pp.542-549
    • /
    • 2002
  • Purpose : The purpose of our study was to assess the usefulness of the Tl-201 SPECT for the detection of the postoperative tumor recurrence on chest wall. Methods: 28 patients including 14 with suspected recurrence of tumor in the chest wall on postoperative chest cr scan, 10 with postoperative pleural effusion which proved benign on radiologic, cytologic and laboratory findings, and 4 with chronic tuberculous empyema as control group were included. All patients underwent SPECT 30 minutes and 4 hours after intravenous injection of 111MBq of Tl-201. Tumor uptake was visually graded by two interpreters and scored as follows : no uptake:0, similar to contralateral lung: 1, higher than contralateral lung but less than heart:2 and similar to heart:3. Results : Markedly increased (grade 3 or 2) Tl-201 uptake was noted in patients with suspected recurrence of tumor in the chest wall (13/14) whereas no (8/10) or minimal (2/10) uptake along the collapsed lung in patients with postoperative benign pleural effusion. In two patients, Tl-201 SPECT revealed additional recurrent tumor mass lesions that were barely perceptible on chest cr scan. Patients with chronic tuberculous empyema showed relatively smoothly marginated increased uptake along the chest wall 4/4), but lesser in degree (grade 1 or 2), when compared to recurrent tumor uptake. Conclusion : Tl-201 lung SPECT seems to be useful to detect postoperative tumor recurrence on chest wall and to differentiate malignant from benign pleural effusion and may provide additional information to the morphologic data obtained by CT.

A Case of Thymoma Misdiagnosed as Parathyroid Adenoma on Tc-99m pertechnetate/Tl-201 Subtraction Scintigraphy (Tc-99m pertechnetate/Tl-201 감영 신티그라피에서 부갑상선 선종으로 오인된 흉선종 1예)

  • Chung, Yong-An;Yoo, Ie-Ryung;Kim, Sung-Hoon;Chung, Soo-Kyo;Wang, Young-Pil;Jung, Ji-Han;Lee, Kyo-Young;Kim, Byung-Kee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.4
    • /
    • pp.274-279
    • /
    • 2001
  • A large superior mediastinal mass was found incidentally by ultrasonography in a 60-year-old man. There was an abnormal accumulation of Tl-201 in the lower pole of left thyroid gland, extending into left superior mediastinum on Tc-99m pertechnetate/Tl-201 subtraction scan. Laboratory findings relating thyroid and parathyroid were all within normal range. We considered the mass as a non-functioning parathyroid adenoma tentatively. However, subsequent surgery and pathologic examination revealed the mass to be a benign mixed thymoma. We report a case of patient with thymoma showing unusual Tc-99m pertechnetate/Tl-201 subtraction imaging and laboratory findings, and suggest to consider the possibility of other mediastinal tumors rather than parathyroid adenoma.

  • PDF