Comparison of Ga-67, Tl-201 and Tc-99m MIBI Imaging in Lymphoma Patients

림프종 환자에서의 갈륨, Tl-201 그리고 Tc-99m MIBI 섭취의 비교

  • Chun, Kyung-Ah (Departments of Nuclear Medicine, College of Medicine, Yeungnam University) ;
  • Cho, Ihn-Ho (Departments of Nuclear Medicine, College of Medicine, Yeungnam University) ;
  • Won, Kyu-Chang (Departments of Internal Medicine, College of Medicine, Yeungnam University) ;
  • Lee, Kyung-Hee (Departments of Internal Medicine, College of Medicine, Yeungnam University) ;
  • Lee, Hyung-Woo (Departments of Internal Medicine, College of Medicine, Yeungnam University) ;
  • Hyun, Myung-Soo (Departments of Internal Medicine, College of Medicine, Yeungnam University) ;
  • Lee, Jae-Tae (Department of Nuclear Medicine, School of Medicine, Kyungpook National University) ;
  • Lee, Kyu-Bo (Department of Nuclear Medicine, School of Medicine, Kyungpook National University)
  • 천경아 (영남대학교 의과대학 핵의학교실) ;
  • 조인호 (영남대학교 의과대학 핵의학교실) ;
  • 원규장 (영남대학교 의과대학 내과학교실) ;
  • 이경희 (영남대학교 의과대학 내과학교실) ;
  • 이형우 (영남대학교 의과대학 내과학교실) ;
  • 현명수 (영남대학교 의과대학 내과학교실) ;
  • 이재태 (경북대학교 의과대학 핵의학교실) ;
  • 이규보 (경북대학교 의과대학 핵의학교실)
  • Published : 2002.12.30

Abstract

Purpose: Ga-67 scintigraphy has been used for the evaluation of tumors, especially lymphoma. Recently, Tl-201 and Tc-99m MIBI were also used to tumor imaging. Tl-201 and Tc-99m MIBI had better physiologic characteristics than Ga-67, so we studied 32 biopsy proven lymphoma patients (male 24, female 8, mean age 46 years) with Ga-67, Tl-201 or Tc-99m MIBI and compared the scan findings. Materials and Methods: Twenty-three of 32 patients were injected 74-111 MBq (2-3 mCi) of Tl-201, before chemotherapy and imaged with dual-headed SPECT (Prism 2000, Picker, USA) at 30 minutes after injection. Delayed images were obtained after 3 hr in 8 patients. Twenty seven of 32 patients were injected 740 MBq (20 mCi) of Tc-99m MIBI and imaged at 30 minutes after injection. 111-185 MBq (3-5 mCi) of Ga-67 was injected in 12 patients and imaged at 48 and 72 hours after injection. Twenty eight patients were diagnosed as non-Hodgkin's lymphoma and others were Hodgkin's lymphoma. Results: Twenty patients were positive on Tl-201 scan and 3 patients showed negative findings. One of these 3 patients, Tc-99m MIBI and Ga-67 scan were positive. Twenty two patients were positive on Tc-99m MIBI scan and 5 patients showed negative findings. One of these 5 patients, Tl-201 was positive and 2 were positive on Ga-67 scan. Ten of 12 patients showed positive findings on Ga-67 scan. The sensitivity of these agents were 83.3%, 87.0% and 81.5% for Ga-67, Tl-201 and Tc-99m MIBI, respectively. The sensitivity was highest in Tl-201 scan, but there were no significant differences among three tests. In this study, there was no significant difference of uptake ratios between early and delayed images of Tl-201. Conclusion: Scintigraphy with Tl-201 and Tc-99m MIBI in lymphoma patients have similar sensitivity with Ga-67.

Ga-67스캔은 림프종의 평가에 널리 이용되어져 왔다. 최근에 Tl-201과 Tc-99m MIBI가 종양의 평가에 사용되고 있으며, 특히 림프종에서 이들 방사성 의약품을 이용한 연구들이 보고된 바 있다. 본 연구는 림프종으로 진단된 32명의 환자에서 Tl-201, Tc-99m MIBI 그리고 Ga-67 스캔을 실시하여 그 섭취를 비교하고 각 검사간의 차이를 살펴 보았다. 조직검사상 림프종으로 증명된 32명(2-76세, 평균연령 46세)을 대상으로 하였다. 32명 중 23명에서 Tl-201 스캔을 실시하였고, 27명에서는 Tc-99m MIBI 스캔을 실시하였으며, Ga-67스캔은 12명의 환자에서 실시하였다. Tl-201 스캔은 74-111 MBq을 환자에 주사한 후 30분에 영상을 얻었으며, 이들 중 8명에서 3시간 지연영상을 얻었다. Tc-99m MIBI는 740 MBq의 용량을 투여한 후 역시 30분에 영상을 얻었다. Ga-67은 111-185 MBq를 투여한 후 48시간과 72시간에 영상을 얻었다. 32명의 환자 중 호지킨 림프종 환자는 4명이었고, 비호지킨 림프종 환자는 28명 이었다. Tl-201 스캔을 시행한 23예 중에서 20예가 양성소견을 보였으며, Tc-99m MIBI영상에서는 27예 중 22예가 양성소견을 보였다. 음성소견을 보인 5예중 1예에서는 Tl-201 영상에서 양성소견을 보였고, 2예에서는 Ga-67 영상이 양성으로 나타났다. 12예의 Ga-67 영상에서는 10예에서 양성소견을 보여, Ga-67 및 Tl-201과 Tc-99m MIBI 스캔의 예민도는 각각 83.3%, 87.0% 그리고 81.5% 였다. Tl-201 스캔의 예민도가 가장 높았으나, 각 검사간에 통계적으로 유의한 차이는 없었다(p=0.905). Tl-201 스캔의 조기영상과 지연영상사이에 섭취율의 차이는 없었으며, 이들과 Tc-99m MIBI 스캔 영상사이에도 섭취율의 유의한 차이는 보이지 않았다. Tl-201과 Tc-99m MIBI를 이용한 연구에서 Ga-67과 유사하게 림프종 환자의 진단과 추적 검사로 유용함을 보였다.