• Title/Summary/Keyword: Three coil

Search Result 352, Processing Time 0.025 seconds

The Optimum Structure Design of 1005 RF Chip Inductors for GHz Band (GHz 대역을 위한 1005 RF 칩 인덕터의 최적 구조 설계)

  • Kim, Jae-Wook;Ryu, Chang-Keun
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.785-788
    • /
    • 2005
  • In this study, micro-scale, high-performance, solenoid-type RF chip inductors were investigated. The size of the RF chip inductors fabricated in this work was $1.0{\times}0.5{\times}0.5mm^3$ The material and shape of the core were 96% $Al_2O_3$ and I-type. The material and number of turn of coil were copper (Cu) and 6. The diameter ($40{\mu}m$) of coil and length (0.35mm) of solenoid were determined by a Maxwell three-dimensional field simulator to maximize the performance of the inductors. High frequency characteristics of the inductance (L) and quality-factor (Q) of developed inductors were measured using an RF Impedance/Material Analyzer (HP4291B with HP16193A test fixture). The inductors developed have inductances of 10.8nH and quality factors of 25.2 at 250MHz, and show results comparable to those measured for the inductors prepared by CoilCraftTm that is one of the best chip inductor company in the world. The simulated data predicted the high-frequency data of the Land Q of the inductors developed well.

  • PDF

Judgement Criterion of Insulation Deterioration in 4.16kV and 6.6kV Motor Stator Windings (4.16kV 및 6.6kV 전동기 고정자 권선의 절연열화 판정기준)

  • Kim, Hee-Dong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.4
    • /
    • pp.788-794
    • /
    • 2009
  • To assess the condition of stator insulation, nondestructive tests were performed on twenty five coil groups and twenty six motors. The stator windings has nominal ratings of 6.6kV and are classified into five coil groups ;one group with healthy insulation and four groups with four different types of artificial defects. After completing nondestructive tests, the AC voltage applied to the stator windings was gradually increasing until insulation failure in order to obtain the breakdown voltage. No.1, No.2 and No.6 of 6.6kV motors failed near rated voltage of 14kV, 8.7kV and 14kV, respectively. The breakdown voltage of three motors was lower that expected for good quality coils(14.2kV) in 6.6kV motors. No.3 and No.6 of 4.16kV motors failed near rated voltage of 5.6kV and 4.2kV, respectively. Almost all of failures were located in a line-end coil at the exit from the core slot. The breakdown voltages and the types of defects showed strong relation to the stator insulation tests such as in the case of AC current, dissipation factor(tan${\delta}$) and partial discharge magnitude.

Analysis of Stiffness for Frustum-shaped Coil Spring (원추형 코일스프링의 강성해석)

  • Kim, Jin-Hun;Lee, Soo-Jong;Kim, Jung-Ryul
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.2
    • /
    • pp.250-255
    • /
    • 2008
  • Springs are widely utilized in machine element. To find out stiffness of frustum-shaped coil spring, the space beam theory using the finite element method is adopted in this paper. In three dimensional space, a space frame element is a straight bar of uniform cross section which is capable of resisting axial forces, bending moments about two principal axes in the plane of its cross section and twisting moment about its centroidal axis. The corresponding displacement degrees of freedom are twelve. To find out load vector of coil spring subjected to distributed compression. principle of virtual work is adapted. And this theory was programming using MATLAB software. To compare FEM using MATLAB software was applied MSC. Nastran software. The geometry model for MSC. Patran was produced by 3-D design modeling software. Finite element model was produced by MSC. Patran. Finite element was applied tetra (CTETRA) having 10 node. The analysis results of the MATLAB and MSC. Nastran are fairly well agreed with those of various experiments. Using MATLAB program proposed in this paper and MSC. Nastran, spring constants and stresses can be predicted by input of few factors.

Studies on Enterotoxigenic Escherichia coli Isolated from Cattle (우(牛) 유래(由來) 장독소(腸毒素) 산생(産生) 대장균(大腸菌)에 대하여)

  • Lee, Gang-log;Choi, Won-pil
    • Korean Journal of Veterinary Research
    • /
    • v.26 no.1
    • /
    • pp.69-77
    • /
    • 1986
  • The purpose of this study was the examination for presence of K99 antigen (K99), enterotoxigenicity, 0-groups, colicin and antibiotic susceptibility among E. coil isolated from calves and cows. A total of 49(18.7%) among 262 strains, isolated from 30(26.5%) out of 113 calves and cows, possesed K99, and thirty three of 49 $K99^+$ strains produced ST. Of the strains of diarrheal calf origin which less than 15 days old, a high correlation was observed between enterotoxigenic ability and K99: 92.3% of the $K99^+$ strains produced heat stable enterotoxin(ST). In O group typing of 33 $ST^+$ strains, they belonged to O20(48.4%), O8(9.1%), O9(6.1%), O139(6.1%), O149(6.1%), O101(3.0%), O115(3.0%), except six which were untypable or autoagglutinable. Of 262 E. coil isolates, 30 strains(13.3%) produced colicin and K99 were detected in 6 strains. One hundred eighty eight strains(71.8%) of 262 E. coil isolates were resistance to ampicillin, chloramphenicol, gentamicin, kanamycin, streptomycin, tetracycline, alone or in combination thereof. One hundred and fourteen(60.6%) out of 188 drug resistance strains carried R factor($R^+$) which were transferable to the recipients by conjugation. Sixty five $R^+$ strains(57.0%) carried thermo-sensitive R plasmid.

  • PDF

Spherical Flux Concentration Transmitter for Omnidirectional Wireless Power Transfer with Improved Power Transmission Distance (전력전송거리 증가를 위한 구형 자속 집중 송신부 구조의 설계 및 해석)

  • Park, Kwang-Rock;Cha, Hwa-Rang;Kim, Rae-Young;Kim, Tae-Jin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.3
    • /
    • pp.181-187
    • /
    • 2020
  • In this study, we propose a spherical flux concentration structure for omnidirectional wireless power transfer. Omnidirectional wireless power transfer technology is a method that can transmit power to a transmitter located in an arbitrary position in a two-dimensional or three-dimensional space. However, to improve the power transfer distance in a wireless power transfer system, the diameter of the coil or the number of windings must increase, thereby increasing the size of the transmitter. The proposed transmitter structure adds a ferrite core inside the transmitter coil so that the magnetic flux generated by the transmitter is directed toward the position of the receiver. As a result, the flux linkage and the mutual inductance increase. By implementing the omnidirectional wireless power transfer system using the proposed structure, the power transfer distance can be improved by 65% compared with the conventional system without increasing the size of the transmitter. Simulation shows that the proposed spherical flux concentration structure increases the mutual inductance of the omnidirectional wireless power transmission system.

Performance Test of Search Coil Sensors with Different Core Types

  • Hyeonji Kang;Ho Jin;Yunho Jang;Seungmin Lee;Hyeonhu Park;Juhyeong Kim;Wooin Jo
    • Journal of Astronomy and Space Sciences
    • /
    • v.41 no.3
    • /
    • pp.139-148
    • /
    • 2024
  • A search coil magnetometer (SCM) is a common equipment to observe energy transmission and vibrations in space physics, enabling measurements across a wide frequency range of up to tens of kilohertz. This study proposes the designs of a magnetic core that allows a low-mass sensor and improves its performance: a rod core, sheet-stacked core, and rolling-sheet core. Subsequently, the performance of each sensor was investigated. The sheet-stacked core using the cobalt-based alloy exhibited the highest sensitivity, although it exhibited instability beyond 20 kHz. In contrast, the rod and rolling-sheet core sensors demonstrated stability in the magnetic field measurements (10 Hz-40 kHz). Moreover, the noise equivalent magnetic induction (NEMI) of the rod- and rolling-sheet core sensors were 0.014 pT Hz-1/2 and 0.012 pT Hz-1/2 at 1 kHz, respectively. The rolling-sheet core with high relative permeability achieved a mass reduction of over three times that of the rod core while exhibiting sufficient sensitivity.

Sptimum Design of a Uniform Magnetic Field Exposure System for a Small-Sized Animal Study (자계 균일 공간 확보를 위한 소동물 실험용 5G급 자계 발생장치의 최적 설계)

  • 김상범;추장희;이동일;명성호
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.7
    • /
    • pp.1194-1203
    • /
    • 2000
  • A magnetic field exposure system that generates 60 Hz magnetic fields from 1 mG to 5 G was designed and constructed for small-sized animal study. In order to investigate as many animals as possible at one series of test, uniform magnetic fields are required at wide living area of the animals. In this article, a cubic shaped field exposure system with three animal living floors was designed, which offers about 50 seating capacity. For calculation of magnetic fields inside the cage, a three-dimensional calculation program was developed. Using this, optimum electric current ratio of inner coil to outer coil and position of each coil were determined. Meanwhile, inductance of the exposure system was calculated for the design of power supply. The field measurement results of the manufactured exposure system showed that the difference between maximum and minimum magnetic field at the testing floors was less than 3%, which strongly demonstrated the field exposure system was good for small sized animal study.

  • PDF

Clinical and Radiogical Outcomes of Endovascular Detachable Coil Embolization in Paraclinoid Aneurysms : A 10-Year Experience

  • Jin, Sung-Chul;Kwon, Do-Hoon;Ahn, Jae-Sung;Kwun, Byung-Duk;Song, Young;Choi, Choong-Gon
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.1
    • /
    • pp.5-10
    • /
    • 2009
  • Objective : Direct surgical clipping of paraclinoid aneurysms poses technical challenges to even very experienced neurosurgeons, making endovascular treatment an alternative treatment modality in many centers. We have therefore retrospectively evaluated the safety and efficacy of endovascular detachable coil embolization of paraclinoid aneurysms. Methods : From June 1997 to June 2007, 65 patients underwent endovascular detachable coiling for 67 paraclinoid aneurysms (of which 9 were ruptured and 58 were unruptured) in our institute. Their medical records, radiological images and readings, and operation records were reviewed retrospectively. Results : After the initial embolization procedure, complete occlusion was achieved in 29 (43.3%) of the aneurysms treated by endovascular detachable coiling. Six aneurysms required retreatment, with two each requiring one, two, or three additional endovascular procedures. Fifty-five (82.1%) aneurysms were measured by three-dimensional time of flight (TOF) magnetic resonance images (MRI) or transfemoral cerebral angiography (TFCA) at a mean follow-up of 29.7 months (range from 4 to 94 months), with 39 aneurysms (70.9%) showing complete occlusion. Thromboembolic events (3.8%) were the most frequent complication. Rupture did not occur during or after any of the procedures. According to the Glasgow Outcome Scale (GOS), 98.4% of the patients treated by coil embolization had a score of 4 or 5. Conclusion : Our results indicate that endovascular detachable coiling is a safe and effective treatment modality in paraclinoid aneurysms.

A Study on Fingerprint-Based Coil Alignment Improvement Technique for Magnetic Resonant Wireless Power Transfer System (핑거프린트 방식의 자기 공진형 무선전력전송 코일 정렬 상태 개선 기법 연구)

  • Kim, Sungjae;Lee, Euibum;Ku, Hyunchul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.1
    • /
    • pp.38-44
    • /
    • 2019
  • This paper proposes fingerprint-based positioning methods which can be used in a magnetic resonant wireless power transfer(WPT) system and verifies their performance. A new receiver coil with small orthogonal auxiliary coils is proposed to measure magnetic field signals in three axial directions. The magnitude and phase characteristics of the three-axis electromotive force can be obtained by using the proposed coil. To predict a position with the measured values, we propose a lookup table-based method and linear discriminant analysis-based method. For verification, the proposed methods are applied to predict 75 positions of the 6.78 MHz WPT system, and the performances such as accuracy and computation time are compared.

Types of Thromboembolic Complications in Coil Embolization for Intracerebral Aneurysms and Management

  • Kim, Hong-Ki;Hwang, Sung-Kyun;Kim, Sung-Hak
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.3
    • /
    • pp.226-231
    • /
    • 2009
  • Objective : We describe our clinical experiences and outcomes in patients who had thromboembolic complications occurring during endovascular treatment of intracerebral aneurysms with a review of the literature. The types of thromboembolic complications were divided and the treatment modalities for each type were described. Methods : Between August 2004 and March 2009 we performed endovascular embolization with Guglielmi detachable coils for 173 patients with 189 cerebral aneurysms, including ruptured and unruptured aneurysms at our hospital. Sixty-eight patients were males and 105 patients were females. The age of patients ranged from 22-82 years (average, 58.8 years). We retrospectively evaluated this group with regard to complication rates and outcomes. The types of thromboembolic complications were classified into the following three categories: mechanical obstruction, distal embolic stroke, and stent-induced complications, which corresponded to types I, II, and III, respectively. A comparison of the clinical results was made for each type of complication. Results : Only eight patients had a thromboembolic complication during or after a procedure (4.6%). Of the eight patients, two had a mechanical obstruction as the causative factor; the other three patients had distal embolic stroke as the causative factor. The remaining three patients had stent-induced complications. In cases of mechanical obstruction, recanalization occurred due to the use of intra-arterial thrombolytic agents in one of two patients. Nevertheless, a poor prognosis was seen. In the cases of stent-induced complications, in one of three patients in whom a thrombus developed following stent insertion, a middle cerebral artery territory infarct developed with a poor prognosis despite the use of wiring and an intra-arterial thrombolytic agent. In the cases of distal embolic stroke, all three patients achieved good results following the use of antiplatelet agents. Conclusion : Treatment for thromboemboic complications due to mechanical obstruction and stent-induced complications include antiplatelet and intra-arterial thrombolytic agents; however, this cannot guarantee a sufficient extent of effectiveness. Therefore, active treatments, such as balloon angioplasty, stent insertion, and clot extraction, are helpful.