Objective : We describe our clinical experiences and outcomes in patients who had thromboembolic complications occurring during endovascular treatment of intracerebral aneurysms with a review of the literature. The types of thromboembolic complications were divided and the treatment modalities for each type were described. Methods : Between August 2004 and March 2009 we performed endovascular embolization with Guglielmi detachable coils for 173 patients with 189 cerebral aneurysms, including ruptured and unruptured aneurysms at our hospital. Sixty-eight patients were males and 105 patients were females. The age of patients ranged from 22-82 years (average, 58.8 years). We retrospectively evaluated this group with regard to complication rates and outcomes. The types of thromboembolic complications were classified into the following three categories: mechanical obstruction, distal embolic stroke, and stent-induced complications, which corresponded to types I, II, and III, respectively. A comparison of the clinical results was made for each type of complication. Results : Only eight patients had a thromboembolic complication during or after a procedure (4.6%). Of the eight patients, two had a mechanical obstruction as the causative factor; the other three patients had distal embolic stroke as the causative factor. The remaining three patients had stent-induced complications. In cases of mechanical obstruction, recanalization occurred due to the use of intra-arterial thrombolytic agents in one of two patients. Nevertheless, a poor prognosis was seen. In the cases of stent-induced complications, in one of three patients in whom a thrombus developed following stent insertion, a middle cerebral artery territory infarct developed with a poor prognosis despite the use of wiring and an intra-arterial thrombolytic agent. In the cases of distal embolic stroke, all three patients achieved good results following the use of antiplatelet agents. Conclusion : Treatment for thromboemboic complications due to mechanical obstruction and stent-induced complications include antiplatelet and intra-arterial thrombolytic agents; however, this cannot guarantee a sufficient extent of effectiveness. Therefore, active treatments, such as balloon angioplasty, stent insertion, and clot extraction, are helpful.
Keywords
Thromboembolism; Coil embolizatio; Mechanical obstruction; Distal embolic stroke; Stent-induced complication;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
Times Cited By Web Of Science : 1  (Related Records In Web of Science)
Times Cited By SCOPUS : 1
연도 인용수 순위
1 Henkes H, Fischer S, Weber W, Miloslavski E, Felber S, Brew S, et al. : Endovascular coil occlusion of 1811 intracranial aneurysms : early angiographic and clinical results. Neurosurgery 54 : 268-280; discussion 280-285, 2004   DOI   PUBMED   ScienceOn
2 Pruvo JP, Leclerc X, Ares GS, Lejeune JP, Leys D : Endovascular treatment of ruptured intracranial aneurysms. J Neurol 246 : 244-249, 1999   DOI   ScienceOn
3 Qureshi AI, Suri MF, Khan J, Kim SH, Fessler RD, Ringer AJ, et al. : Endovascular treatment of intracranial aneurysms by using Guglielmi detachable coils in awake patients: safety and feasibility. J Neurosurg 94 : 880-885, 2001   DOI   ScienceOn
4 Soeda A, Sakai N, Sakai H, Iihara K, Yamada N, Imakita S, et al. : Thromboembolic events associated with Guglielmi detachable coil embolization of asymptomatic cerebral aneurysms : evaluation of 66 consecutive cases with use of diffusion-weighted MR imaging. AJNR Am J Neuroradiol 24 : 127-132, 2003   PUBMED
5 Workman MJ, Cloft HJ, Tong FC, Dion JE, Jensen ME, Marx WF, et al. : Thrombus formation at the neck of cerebral aneurysms during treatment with Guglielmi detachable coils. AJNR Am J Neuroradiol 23 : 1568-1576, 2002   PUBMED
6 Brilstra EH, Rinkel GJ, van der Graaf Y, van Rooij WJ, Algra A : Treatment of intracranial aneurysms with embolization with coils : a systematic review. Stroke 30 : 470-476, 1999   DOI   PUBMED   ScienceOn
7 Cognard C, Weill A, Castaings L, Rey A, Moret J : Intracranial berry aneurysms : angiographic and clinical results after endovascular treatment. Radiology 206 : 499-510, 1998   DOI   PUBMED
8 Eskridge JM, Song JK : Endovascular embolization of 150 basilar tip aneurysms with Guglielmi detachable coils : results of the Food and Drug multicenter clinical trial. J Neurosurg 89 : 81-86, 1998   DOI   ScienceOn
9 Pelz DM, Lownie SP, Fox AJ : Thromboembolic events associated with the treatment of cerebral aneurysms with Guglielmi detachable coils. AJNR Am J Neuroradiol 19 : 1541-1547, 1998   PUBMED
10 Chung SW, Baik SK, Kim Y, Park J : Thromboembolic events after coil embolization of cerebral aneurysms : Prospective study with diffusion-weighted magnetic resonance imaging follow-up. J Korean Neurosurg Soc 43 : 275-280, 2008   DOI   PUBMED   ScienceOn
11 Kl$\ddot{o}$tzsch C, Nahser HC, Henkes H, K$\ddot{u}$hne D, Berlit P : Detection of microemboli distal to cerebral aneurysms before and after therapeutic embolization. AJNR Am J Neuroradiol 19 : 1315-1318, 1998   PUBMED
12 Sakai H, Sakai N, Higashi T : Embolic complications of endovascular surgery for cerebrovascular diseases : evaluation with diffusionweighted MR imaging. Intervent Neuroradiol 6 (Suppl) : 223-226, 2000
13 Rordorf G, Bellon RJ, Budzik RE Jr, Farkas J, Reinking GF, Pergolizzi RS, et al. : Silent thromboemoblic events associated with the treatment of unruptured cerebral aneurysms by use of Guglielmi detachable coils : prospective study applying diffusion-weighted imaging. AJNR Am J Neuroradiol 22 : 5-10, 2001   PUBMED
14 Derdeyn CP, Cross DT 3rd, Moran CJ, Brown GW, Pilgram TK, Diringer MN, et al. : Postprocedure ischemic events after treatment of intracranial aneurysms with Guglielmi detachable coils. J Neurosurg 96 : 837- 843, 2002   DOI   ScienceOn
15 McDougall CG, Halbach VV, Dowd CF, Higashida RT, Larsen DW, Hieshima GB : Endovascular treatment of basilar tip aneurysms using electrolytically detachable coils. J Neurosurg 84 : 393-399, 1996   DOI   ScienceOn
16 Bendszus M, Koltzenburg M, Burger R, Warmuth-Metz M, Hofmann E, Solymosi L : Silent embolism in diagnostic cerebral angiography an neurointerventional procedures : a prospective study. Lancet 354 : 1594-1597, 1999   DOI   ScienceOn
17 Byrne JV, Hope JK, Hubbard N, Morris JH : The nature of thrombosis induced by platinum and tungsten coils in saccular aneurysms. AJNR Am J Neuroradiol 18 : 29-33, 1997   PUBMED
18 Horowitz M, Samson D, Purdy P : Does electrothrombosis occur immediately after embolization of an aneurysm with Guglielmi detachable coils? AJNR Am J Neuroradiol 18 : 510-513, 1997   PUBMED
19 Vinuela F, Duckwiler G, Mawad M : Guglielmi detachable coil embolization of acute intracranial aneurysm : perioperative anatomical and clinical outcome in 403 patients. J Neurosurg 86 : 475-482, 1997   DOI   ScienceOn
20 Cronqvist M, Pierot L, Boulin A, Cognard C, Castaings L, Moret J : Local intraarterial fibrinolysis of thromboemboli occurring during endovascular treatment of intracerebral aneurysm : a comparison of anatomic results and clinical outcome. AJNR Am J Neuroradiol 19 : 157-165, 1998   PUBMED
21 Song JK, Niimi Y, Fernandez PM, Brisman JL, Buciuc R, Kupersmith MJ, et al. : Thrombus formation during intracranial aneurysm coil placement : treatment with intraarterial abciximab. AJNR Am J Neuroradiol 25 : 1147-1153, 2004   PUBMED
22 Guglielmi G, Vinuela F, Dion J, Duckwiler G : Electrothrombosis of saccular aneurysms via endovascular approach. Part 2 : Prelieminary clinical experience. J Neurosurg 75 : 8-14, 1991   DOI   PUBMED
23 Murayama Y, Vinuela F, Duckwiler GR, Gobin YP, Guglielmi G : Embolizatiion of incidental cerebral aneurysms by using the Guglielmi detachable coil system. J Neurosurg 90 : 207-214, 1999   DOI   ScienceOn
24 Debrun GM, Vinuela FV, Fox AJ : Aspirin and systemic heparinization in diagnostic and interventional neuroradiology. AJR Am J Roentgenol 139 : 139-142, 1982   DOI   PUBMED   ScienceOn