• Title/Summary/Keyword: Thermal-Comfort

Search Result 701, Processing Time 0.026 seconds

A Study on Climate Change KML Contents Publishing by using Meteorological Model (수치모델을 이용한 기후변화 KML 콘텐츠 출판 연구)

  • An, Seung-Man;Choi, Yeong-Jin;Eum, Jung-Hee;Jeon, Sang-Hee;Sung, Hyo-Hyun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.19 no.4
    • /
    • pp.35-45
    • /
    • 2011
  • The purpose of this study is visualizing climate change contents from Weather Research and Forecasting model and providing useful tool to anyone who want to use them for communication and actual movement. As a results, we have built a process and user interface for publishing Arrow KML, BWS KML, and DI KML. Arrow KML provide wind rose service and wind attribute information for each arrow. BWS KML provide a wind power index and DI KML provide a thermal comfort. All KML contents are more reliable because those are visualized from the scientifically verified climate change prediction model. Further study will focus on searching for climate change contents mining and useful contents design for wide range of climate change mitigation/adaptation activity.

Effects of Fiber Type and Blouse Design on the Clothing Microclimate (의복재료와 상체부 의복형태변화가 의복내기후에 미치는 효과)

  • Kim Ok Jin;Kim Yong Ser;Shin Youn Sook;Lee Young Suk;Chung Myung Sun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.14 no.1 s.33
    • /
    • pp.20-30
    • /
    • 1990
  • In order to investigate the mechanism of the formation of clothing microclimate with different blouse designs and materials, physiological and subjective sensational changes were measured. Experimental clothing were four types of blouse made of $100\%$ cotton, $100\%$ regular polyes­ter, and $100\%$ hygroscopic polyester. Four types of box style blouse were with stand collar and long sleeve, with stand collar and sleeveless, with long sleeve and collarless, and sleeveless and collarless. Five healthy female were chosen as subjects. Experiments were carried out in the environ­mental chamber controlled at $28{\pm}1^{\circ}C$ , $70{\pm}5\%$ RH. and still-air condition for SO min. The skin temperature (9 spots), oral temperature, humidity inside chest, and subjective sensations were measured. Obtained results are: I) Material which is capable of absorbing sweat effectively and transfering moisture rapidly made a comfortable feeling, because cloth­ing humidity is increasing slowly at this material. 2) During exercise period, covered arms have more influenced on thermal comfort than a covered neck.

  • PDF

Development of Impact-based Heat Health Warning System Based on Ensemble Forecasts of Perceived Temperature and its Evaluation using Heat-Related Patients in 2019 (인지온도 확률예보기반 폭염-건강영향예보 지원시스템 개발 및 2019년 온열질환자를 이용한 평가)

  • Kang, Misun;Belorid, Miloslav;Kim, Kyu Rang
    • Atmosphere
    • /
    • v.30 no.2
    • /
    • pp.195-207
    • /
    • 2020
  • This study aims to introduce the structure of the impact-based heat health warning system on 165 counties in South Korea developed by the National Institute of Meteorological Sciences. This system was developed using the daily maximum perceived temperature (PTmax), which is a human physiology-based thermal comfort index, and the Local ENSemble prediction system for the probability forecasts. Also, A risk matrix proposed by the World Meteorological Organization was employed for the impact-based forecasts of this system. The threshold value of the risk matrix was separately set depending on regions. In this system, the risk level was issued as four levels (GREEN, YELLOW, ORANGE, RED) for first, second, and third forecast lead-day (LD1, LD2, and LD3). The daily risk level issued by the system was evaluated using emergency heat-related patients obtained at six cities, including Seoul, Incheon, Daejeon, Gwangju, Daegu, and Busan, for LD1 to LD3. The high-risks level occurred more consistently in the shorter lead time (LD3 → LD1) and the performance (rs) was increased from 0.42 (LD3) to 0.45 (LD1) in all cities. Especially, it showed good performance (rs = 0.51) in July and August, when heat stress is highest in South Korea. From an impact-based forecasting perspective, PTmax is one of the most suitable temperature indicators for issuing the health risk warnings by heat in South Korea.

The Wearing Sensation and Physiological Responses in School Wear in the High School Girl's (여고생 통학복의 착용감과 생리반응에 관한 연구)

  • Kweon, Soo-Ae
    • Korean Journal of Human Ecology
    • /
    • v.7 no.2
    • /
    • pp.81-91
    • /
    • 1998
  • The subjects in this research were 368 girls in high school for survey, and wearing sensation and physiological responses were investigated through wearing trials on human body in climatic chamber based on these results from the survey. The results are as follows : 1. They enjoyed wearing t-shirts, jackets, vests, and blouses in order for the upper clothes, and they preferred t-shirts to blouses. For the lower clothes, they enjoyed slacks much more than skirts. The weight of clothes was significantly heavier in the group where they wore the uniforms(U-group) than in the group where they wore the free styles(F-group). When they chose the school wear, activity was the most important of all, and the maintenance was the least. 2. As the classes were a little cool and dry, most of them dissatisfied the environment. The degree of the satisfaction of the class environment and properties to it were higher in the U-group than in F-group. 3. In the textiles, colors, styles, activity, static electricity, seasonal property, and easiness of putting on and taking off the clothes, F-group was more satisfied than U-group. U-group was more satisfied than F-group in the soil of the clothes. 4. The thermal comfort, thickness, and tightness of the clothes were not significantly different between the groups. The clothes of U-group was heavier than those of F-group, and the tactile sensation in U-group was worse than F-group. In U-group the students felt the skirts very inconvenient when they acted. 5. The weight of the clothes influenced the wearing sensation, therefore the heavier the clothes were the less satisfied they felt. 6. The inside temperature of clothes was significantly higher in U-group than in F-group. The skin temperatures of abdomen and arm were significantly higher in U-group than in F-group, while the skin temperatures of thighs and legs were significantly lower in U-group than in F-group. U-group felt heavier than F-group in wearing the clothes. Therefore the improvement of the clothes weight is needed.

  • PDF

A Study on the Improvement of Cold Protective Clothing for Mailman (우편배달원 방안복 개선을 위한 연구)

  • Kwon, Myoung-Sook;Seok, Hye-Jung
    • Journal of the Korean Society of Costume
    • /
    • v.57 no.8
    • /
    • pp.14-23
    • /
    • 2007
  • The purpose of this study was to investigate the present condition of cold protective clothing for mailman, to improve its design in movement, fitness, and other functions, and supply basic data for its performance evaluation. The results are as follows : The 46.60% of those questioned did not satisfy current clod protective clothing fer mailman. Especially, they considered dissatisfactory in properties such as waterproof, comfort, activity, and sweat absorption. The newly developed cold protective clothing is two-piece style composed of jacket and pants. Both jacket and pants are composed of inner and outer clothing individually. In both jacket and pants, their outer clothing's material was waterproof, windproof, and breathable shell fabric on which PTFE film laminated and their inner clothing's material was 100% polyester Polar polis to have better insulation property. The jacket has attachable cap which can be used as rain gear and set-in sleeve with stand collar. It also had big outside patch pockets and side seam pockets to ensure enough storage space. The pants have knee pads to give free movement to knees and slant side pockets. Inner clothing of both jacket and pants can be worn during working inside without out clothing. Insulation of the newly developed cold protective clothing was not better than current one except right hand, left hand and left foo. It is considered that is because thickness of material is the most important factor to influence insulation.

Physical Property of Heat Storage Knitted Fabrics for High Emotional Garment (고감성 의류용 축열 니트소재의 물성)

  • Kim, Hyun Ah;Heo, Kyoung;Kim, Seung Jin
    • Fashion & Textile Research Journal
    • /
    • v.17 no.2
    • /
    • pp.295-304
    • /
    • 2015
  • This paper investigated wear comfort property of heat storage knitted fabrics for high emotional garment. For this purpose, ZrC imbedded PET knitted fabric was prepared and various physical properties such as thermal, wicking and drying characteristics were measured. In addition, far-infrared emission characteristics of ZrC imbedded PET was analysed and tactile hand property and dye affinity of ZrC imbedded knitted fabric were also studied in comparison with regular and other commercial heat storage PET knitted fabrics. It was observed that Zr imbedded amount in the yarn was 19.29% by ingredient analysis and far-infrared emission energy was $3.65{\times}10^2W/m^2$, emissivity was 0.906 at the range of wavelength $6{\sim}20{\mu}m$. It was found that maximum heat flow (Qmax) of ZrC imbedded PET knitted fabric was lower than that of regular PET one and warmth keepability rate was higher than that of regular PET one, which means ZrC imbedded PET have heat storage property. Drying property of ZrC imbedded knitted fabric was better than that of regular PET one due to heat by far-infrared emitted from ZrC in the core of filament. It revealed that wicking property of the ZrC imbedded fabric was not influenced by far-infrared emission, but affected by fibre physical properties. Tactile hand property of ZrC imbedded knitted fabric was not influenced by imbedding ZrC in the filament but affected preferably by structure of knitted fabric. Dye affinity of ZrC imbedded PET knitted fabric was less influenced by dyeing temperature and time than regular PET knitted one.

A Study on Correlations of the Gap Ratio of Apartment Houses Arrangement and the Wind Field (공동주택단지배치의 간극비와 바람장의 상관관계에 관한 연구)

  • Moon, Chul-Seong;Oh, Se-Gyu;Cho, Sung-Woo
    • KIEAE Journal
    • /
    • v.11 no.2
    • /
    • pp.75-82
    • /
    • 2011
  • In Korea, the ratio of population in urban areas used to be only 50.1% in 1970, but with the value risen to 90.8% in 2009, urbanization is going on rapidly. Urbanization, which occurs by the rampantly planted buildings, has become major source of raising building density, changing wind direction and reducing wind amount, and such reductions are affecting even inside the building. In each year, among the total energy consumption in Korea, residential portion takes up significant ratio, and specifically the ratio of apartment house is shown to be highest. In order to solve such problem, many studies are being conducted for the improvement of natural ventilation performance. The natural ventilation performance of apartment house are significantly determined by the characteristics of external and internal structure, but in macroscopic perspective, the performance is established fundamentally by the layout characteristics of the main building of the apartment house in preparation for wind conditions. So far researches on raising the thermal comfort through elevation of ventilation performance have been conducted actively, but many of them propose only theoretical concepts deduced through wind path analysis, and do not include any indicator to measure ventilation performance simply only with area data from layout planning stage. Therefore, in this study, gap ratio a wind field measuring indicator was developed, and after the ventilation characteristics by layout types and main building uniformity were identified, the scope of gap ratio efficient for ventilation and that of uniformity were clarified, followed by verification through simulation.

A Study on Indoor Environment Performances of Power Yacht in Summer Season (여름철 파워요트 실내환경 성능에 관한 연구)

  • Lee, Han-Seok;Doe, Guen-Young;Lim, Duck-Min;Kim, Hak-Chul
    • Journal of Navigation and Port Research
    • /
    • v.33 no.3
    • /
    • pp.175-180
    • /
    • 2009
  • In this study, the basic data were collected for improving the amenity of indoor environment of a super yacht and the performance of indoor environment was analyzed by utilizing measured data during summer period. Through the results of examination, the following conclusions are drawn. 1) It is estimated that, in case of closing the door of Saloon connected with outside, there is little inflow of exhaust gas, but when the door is open, the indoor-air might be polluted so fast. Therefore, it is necessary to make a counter plan about the method of ventilation and amount of ventilation to keep the indoor aerial environment agreeable. 2) It is urgent to conceive countermeasure against engine noise because the noise level of all rooms exceeds 60dB, which is regulation of noise for protecting crew established in ship's classification, during the sailing. 3) State cabin and Guest cabin are super cooled by operating air conditioner exceeding agreeableness extent and it is needed to prevent them.

Thermal Comfort and Sleep under Different Room Temperatures (침상내 기후와 수면과의 관계)

  • Lee Young Suk;Engel Peter
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.15 no.4 s.40
    • /
    • pp.351-365
    • /
    • 1991
  • 본 연구에서는, 수면환경의 열적 쾌적도의 측정방법으로서 생리적 반응 뿐만 아닌 국소자극의 반응에 대한 평가법 (Allesthesial Response)에 의 한 가능성을 제시 하고자 하였다. 피험자는 19세에서 22세의 건강한 독일 여자 대학생 5명이며, 실험은 12월과 1월 독일의 KASSEL에 있는 Marburg대학 연구소의 인공기후실에서 이루어졌다. 사용의복은 면 $100\%$의 잠옷이며, 침구는 메트리스와 Wool 담요(두께 180 mm)를 사용하였다. 국소자극 반응의 온도는 $20.0^{\circ}C,\;22.5^{\circ}C,\;25.0^{\circ}C,\;27.5^{\circ}C,\;30.0^{\circ}C,\;32.5^{\circ}C$의 set가 사용되었으며, 온도자극은 Pottier Thermode type PKE 36 HO2-1 (독일, Peltroil사)로서, 온도의 도달정 밀도는 60내지 90초 동안에 각 자극온도의 변화조절이 가능하였다. 수면환경 온도는 $15^{\circ}C,\;18^{\circ}C,\;21^{\circ}C,\;24^{\circ}C,\;27^{\circ}C$의 다섯 환경으로 조절하였으며, 습도는 RH $45\%$였다. 수면환경 $18^{\circ}C$에서 $24^{\circ}C$까지에서는, 수면전, 수면후 모두, 피험자는 약간의 Hypothermia의 경향을 보였지만 Neutral Situation과 큰 차이는 나타나지 않았다. 수면전과 수면후의 체온조절 반응의 차이가 Allesthesial Response와 국소의 쾌적한 온도 선택의 두 실험결과 모두에서 현저히 나타났다. 생리적 반응의 결과에서도 $18^{\circ}C$에서 $21^{\circ}C$까지의 수면환경이 가장 쾌적하게 나타났다. 또한, 실험결과에서 행동적 온도 조절 반응이 생리적 반응에 앞서 보다 민감하게 이루어짐을 볼 수 있었다

  • PDF

The Relationship between Increased Cold Tolerance Resulting from Cool Clothing on Heat Tolerance (의복을 이용한 내한성 향상 훈련이 내열성에 미치는 영향)

  • 이종민
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.21 no.4
    • /
    • pp.669-676
    • /
    • 1997
  • The purpose of this study is to examine the effect of the improved cold tolerance resulting from cool clothing in winter on heat tolerance in summer. Ten healthy women were divided into two groups, cold group(C group) (n=5) and warm group(W group) (n=5) . In the previous study, C group was proved that their cold acclimatization was achieved through wearing cool clothing from September to February of the following year, while Wgroup was not proved because of wearing warm clothing during same period. After February, no more clothing training was continued in two groups. To determine the heat tolerance, both groups were exposed from a thermoneutral environment(25$\pm$1$^{\circ}C$, 50$\pm$5% R.H.) to a hot environment (35$\pm$1$^{\circ}C$, 50$\pm$5% R.H.) before and after clothing training, respectively September in 1994 and truly in 1995. Rectal temperature, skin temperatures, thermal sensation and comfort were measured every 10 min., and Os uptake was measured at 10, 45, 85 min. after entering the chamber for 5 min. Body weight was measured before and after the experiment and amount of local sweat was measured during the 90 min long experiment. The results are as follows: Rectal temperatures in 35'c environment of C group were increased after training when compared with before clothing, while those of W group were not changed. But the changes of rectal temperature and heat production during 90 min in hot environment were almost the same in two groups after training. And mean skin temperatures, the changes of mean skin temperatures during 90 min in hot environment, total sweat amount and local sweat amount after training were also the same in two groups. From these results, it might be supposed that the heat loss of two groups were the same but the heat production, especially heat production during rest in C group was higher than in Wgroup. This fact suggests that the increase of rest heat production from cold acclimatization in winter is maintained to summer of the following year. And mild cold acclimatization coming from westing cool clothing does not have a negative effect on heat tolerance.

  • PDF