• 제목/요약/키워드: Thermal cross-section

검색결과 256건 처리시간 0.024초

그래핀을 적용한 고출력 반도체 광원의 열특성 분석 (Heat Conduction Analysis and Improvement of a High-Power Optical Semiconductor Source Using Graphene Layers)

  • 지병관;오범환
    • 한국광학회지
    • /
    • 제26권3호
    • /
    • pp.168-171
    • /
    • 2015
  • 고출력 반도체 광원의 열유동 특성을 분석하고, 열전달 병목지점을 파악하여 열저항을 개선하는 방안을 도출하고, 전산모사를 통하여 개선 효과를 확인하였다. 띠구조 활성층을 가진 LD 광원의 경우에 발열부의 부피가 작을 뿐 아니라 발열면적이 좁아서 발열부 근처의 열전달 유효단면적이 매우 좁을 수 밖에 없는데, 이 부근의 경계면에 그래핀층을 추가적으로 적용하면 전체 열저항이 확연히 개선되는 것이 전산모사 되었다. 이는 열전달 경로상의 유효단면적이 넓어지는 효과를 가져와 전체 열저항이 확연히 개선되는 것으로 파악되었다.

Optimization of hydraulic section of irrigation canals in cold regions based on a practical model for frost heave

  • Wang, Songhe;Wang, Qinze;An, Peng;Yang, Yugui;Qi, Jilin;Liu, Fengyin
    • Geomechanics and Engineering
    • /
    • 제17권2호
    • /
    • pp.133-143
    • /
    • 2019
  • An optimal hydraulic section is critical for irrigated water conservancy in seasonal frozen ground due to a large proportion of water leakage, as investigated by in-situ surveys. This is highly correlated with the frost heave of underlain soils in cold season. This paper firstly derived a practical model for frost heave of clayey soils, with temperature dependent thermal indexes incorporating phase change effect. A model test carried out on clay was used to verify the rationality of the model. A novel approach for optimizing the cross-section of irrigation canals in cold regions was suggested with live updated geometry characterized by three unique geometric constraints including slope of canal, ratio of practical flow section to the optimal and lining thickness. Allowable frost heave deformation and tensile stress in canal lining are utilized as standard in computation iterating with geometry updating while the construction cost per unit length is regarded as the eventual target in optimization. A typical section along the Jinghui irrigation canal was selected to be optimized with the above requirements satisfied. Results prove that the optimized hydraulic section exhibits smaller frost heave deformation, lower tensile stress and lower construction cost.

파이프 순환수의 수치해석 모사를 통한 수직 밀폐형 지중열교환기 단면의 열전달 효율 평가 (Numerical Evaluation of Heat Transfer un Ground Heat Exchanger Considering Flow through U-loop)

  • 길후정;이강자;이철호;최항석
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.583-587
    • /
    • 2009
  • This paper presents a series of numerical simulations on the thermal performance and sectional efficiency of a closed-loop vertical ground heat exchanger (U-loop) equipped in a geothermal heat pump system (GHP). A 3-D finite volume analysis (Fluent) was used to simulate the operating process of the closed-loop vertical ground heat exchanger by considering the effect of the thickness of HDPE pipe and grout thermal properties, distance between the inflow and outflow pipes, and the effectiveness of the latticed HDPE pipe system. It was observed that the thermal interference between the two strands of U-loop is of importance in determining the efficiency of the ground heat exchanger, and thus it is highly recommendable to modify the cross section configuration of the conventional U-loop system by including a thermally insulating latice between the two strands.

  • PDF

디스크 브레이크 저더 개선을 위한 신뢰성 향상 연구

  • 정원선;이창수;송현석;정도현
    • 한국신뢰성학회:학술대회논문집
    • /
    • 한국신뢰성학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.99-106
    • /
    • 2011
  • In this study, the analysis technique, which can estimate the temperature rise and thermal deformation of the ventilated disc considering the vehicle information, braking condition and properties of the disc and pad, is developed. The analytical process of the braking power generation during braking is mathematically derived. The thermal energy, which is applied to the surface of a disc as heat flux, is calculated. Then, the temperature rise and thermal deformation of a disc are estimated using FE software, SAMCEF. Shape of the cross section of the disc is optimized according to the response surface analysis method in order to minimize the temperature rise and thermal deformation. The hot judder analysis is done using the optimized disc, and the analysis results are discussed.

  • PDF

리플로우 횟수에 따른 플립칩 접합부의 기계적 특성 평가 (The Effects of the reflow number in the Mechanical Reliability of Flip Chip Solder Joint)

  • 박진석;양경천;한성원;신영의
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2007년 추계학술발표대회 개요집
    • /
    • pp.254-256
    • /
    • 2007
  • In this paper, the effects of the reflow number in the mechanical reliability of flip chip solder joint was investigated by flip chip shear test and thermal shock test. For evaluation mechanical reliability of flip chip, We experiment that specimens were operated 3-times, 6-times, 9-times, 12-times under reflow Process. After shear test and thermal shock test, We measured max shear strength and coming first crack number of thermal cycle. And We observe fracture surface and cross section by using SEM(Scanning Electron Microscope) and optical scope. In the results, the more specimens were operated reflow process, the more decreased maximum shear strength and number of thermal cycle.

  • PDF

Green Composites. I. Physical Properties of Ramie Fibers for Environment-friendly Green Composites

  • Nam Sung-Hyun;Netravali Anil N.
    • Fibers and Polymers
    • /
    • 제7권4호
    • /
    • pp.372-379
    • /
    • 2006
  • The surface topography, tensile properties, and thermal properties of ramie fibers were investigated as reinforcement for fully biodegradable and environmental-friendly 'green' composites. SEM micrographs of a longitudinal and cross sectional view of a single ramie fiber showed a fibrillar structure and rough surface with irregular cross-section, which is considered to provide good interfacial adhesion with polymer resin in composites. An average tensile strength, Young's modulus, and fracture strain of ramie fibers were measured to be 627 MPa, 31.8 GPa, and 2.7 %, respectively. The specific tensile properties of the ramie fiber calculated per unit density were found to be comparable to those of E-glass fibers. Ramie fibers exhibited good thermal stability after aging up to $160^{\circ}C$ with no decrease in tensile strength or Young's modulus. However, at temperatures higher than $160^{\circ}C$ the tensile strength decreased significantly and its fracture behavior was also affected. The moisture content of the ramie fiber was 9.9 %. These properties make ramie fibers suitable as reinforcement for 'green' composites. Also, the green composites can be fabricated at temperatures up to $160^{\circ}C$ without reducing the fiber properties.

Investigation of physical characteristics for Al2O3:C dosimeter using LM-OSL

  • Kim, Myung-Jin;Lee, Young-Ju;Kim, Ki-Bum;Hong, Duk-Geun
    • 분석과학
    • /
    • 제32권4호
    • /
    • pp.131-138
    • /
    • 2019
  • This paper reports results on the physical properties of a powder type of $Al_2O_3:C$ commonly used as a luminescence dosimeter using the LM-OSL technique. On the analysis with the general order kinetics model, the LM-OSL signal measured appeared to be composed of three components (fast, medium, slow) showing the largest area in the medium component. The photoionization cross sections of three components were distributed between $10^{-19}{\sim}10^{-21}cm^2$. The values of the thermal assistance energy were evaluated the largest in slow component and the smallest in fast component, which indicates the electrons trapped in defects attributed to slow component should be the most sensitive to thermal vibration among three components. In illumination to blue light, the fast component showed a rapid linear decay and completely disappeared after light exposure time of about 5 s. The medium component decayed with two exponential elements but the slow component did not observed any noticeable change until light exposure time of 40 s. In a dose response study, all components exhibited a linear behaviour up to approximately 10 Gy.

Coupled neutronics/thermal-hydraulic analysis of ANTS-100e using MCS/RAST-F two-step code system

  • Tung Dong Cao Nguyen;Tuan Quoc Tran;Deokjung Lee
    • Nuclear Engineering and Technology
    • /
    • 제55권11호
    • /
    • pp.4048-4056
    • /
    • 2023
  • The feasibility of using the Monte Carlo code MCS to generate multigroup cross sections for nodal diffusion simulations RAST-F of liquid metal fast reactors is investigated in this paper. The performance of the MCS/RAST-F code system is assessed using steady-state simulations of the ANTS-100e core. The results show good agreement between MCS/RAST-F and MCS reference solutions, with a keff difference of less than 77 pcm and root-mean-square differences in radial and axial power of less than 0.5% and 0.25%, respectively. Furthermore, the MCS/RAST-F reactivity feedback coefficients are within three standard deviations of the MCS coefficients. To validate the internal thermal-hydraulic (TH) feedback capability in RAST-F code, the coupled neutronic/TH1D simulation of ANTS-100e is performed using the case matrix obtained from MCS branch calculations. The results are compared to those obtained using the MARS-LBE system code and show good agreement with relative temperature differences in fuel and coolant of less than 0.8%. This study demonstrates that the MCS/RAST-F code system can produce accurate results for core steady-state neutronic calculations and for coupled neutronic/TH simulations.

Development of Piping Analysis Procedure of a PWR Surge Line for Stratified Flow

  • Y. J. Yu;J. H. Jheon;K. S. Yoon;Park, S. H.;Kim, D. H.
    • Nuclear Engineering and Technology
    • /
    • 제28권4호
    • /
    • pp.390-396
    • /
    • 1996
  • Piping Systems are usually designed for thermal expansion loads based on uniform temperatures at each cross section. However, in lines with low flow rates such as surge lines and spray lines, large transverse temperature gradients have been observed, resulting in too types of additional thermal stresses : (1) local thermal gradient stresses which are independent of routing and supports and (2) gross bending stresses due to induced pipe curvature which are routing and support system dependent. This paper presents a simplified method for analyzing a PER surge line for stratified flow.

  • PDF

열전달 매질을 고려한 에너지파일의 열전달 거동 분석 (Heat Transfer Analysis of Energy Pile Considering heat transfer medium)

  • 김도현;정상섬;송진영
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.963-970
    • /
    • 2010
  • In this study, a series of thermal numerical analysis was conducted through the ground condition and the length and shape of the energy pile. In order to investigate the effect of the thermal properties of ground condition, grout and pile type on heat transfer efficiency in the U-type heat exchanger in energy pile, thermal numerical analysis was done by using ABAQUS. ABAQUS, a finite element analyzing program, was employed to evaluate the temperature distribution on the cross section of energy pile system incorporating HDPE - grout - pile - Ground condition which consists of clay, sand, rock type soil and ground water.

  • PDF