• Title/Summary/Keyword: The fire safety

Search Result 3,686, Processing Time 0.031 seconds

Characterization and Anti-Gastric Ulcer Activity of Bamboo Salt (죽염의 특성 분석과 항위궤양효과)

  • 김승희;강석연;정기경;김태균;한형미;류항묵;문애리
    • Journal of Food Hygiene and Safety
    • /
    • v.13 no.3
    • /
    • pp.252-257
    • /
    • 1998
  • Bamboo salt has been used as a traditional remedy for gastric ulcer and gastro-intestinal disorders. It is produced by baking the salt packed in bamboo cylinder nine times under the fire of pine tree. Three of commercially available bamboo salt products (bamboo salt A, B, and C) were characterized by qualitative and quantitative analyses using inductively coupled plasma (ICP) spectrometer, ion chromatograph (IC), X-ray diffractometer (XRD), and electron microscope (EM). Compared with crude salt, the contents of iron, silicon, potassium, and phosphate in the bamboo salt products were higher whereas the sulfate content was lower. Water-insoluble fraction of bamboo salts contained the following compounds; MgO, $SiO_2,\;Mg_2Si0_4,\;and\;CaMgSi0_4$. The study on the microscopic structures of the bamboo salts were shown to have smooth surface and fused shape compared with crude salt. Among the three bamboo salt products, product A was used to test a possible inhibitory effect on gastric acid secretion. Each test material (bamboo salt A, crude salt, and reagent-grade NaCl) was given orally to Sprague-Dawley rats at doses of 0.2, 1.0, and 2.0 g/kg for 28 days before pyrolus ligation. Twenty four hours after the last administration of the test materials, volume, pH, total acidity, and pepsin activity of gastric juice were measured by the Shay-ligation method. No significant differences were observed in the secretion of gastric acid between treated groups (bamboo salt-, crude salt- and reagent-grade NaCI-treated groups) and control group (distilled water-treated group). This result demonstrated that bamboo salt did not exert anti-ulcer activities in experimental animals used in the present study.

  • PDF

An Analysis on the Deployment Methods for Smart Monitoring Systems (스마트 모니터링 시스템의 배치 방식 분석)

  • Heo, No-Jeong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.6
    • /
    • pp.55-62
    • /
    • 2010
  • Monitoring systems are able to report certain events at region of interest(ROI) and to take an appropriate action. From industrial product line full of robots to fire detection, intrusion detection, smart grid application, environmental pollution alarm system, monitoring system has widely used in diverse industry sector. Recently, due to advance of wireless communication technology and availability of low cost sensors, intelligent and/or smart monitoring systems such as sensor networks has been developed. Several deployment methods are introduced to meet various monitoring needs and deployment performance criteria are also summarized to be used to identify weak point and be useful at designing monitoring systems. Both efficiency during deployment and usefulness after the deployment should be assessed. Efficiency factors during deployment are elapsed time, energy required, deployment cost, safety, sensor node failure rate, scalability. Usefulness factors after deployment are ROI coverage, connectivity, uniformity, target density similarity, energy consumption rate per unit time and so on.

A Stress Analysis for Pressure Vessel to Prevent Spontaneous Ignition of Coal Stockpile (저탄장 자연발화 방지를 위한 압력용기의 응력 해석)

  • Kim, Young In;Kim, Seung Hun;Jie, Min-Seok;Yeum, Chan Sub;Choi, Won Hyuck
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.3
    • /
    • pp.205-212
    • /
    • 2018
  • Spontaneous ignition is not only severe economic damage but also a typical plant damage caused by harmful gases generated during the fire. Because coal is porous, it causes oxygen to be absorbed in the amount of oxygen per unit weight of oxygen, resulting in low humidity and low thermal conductivity. The cause and effect of spontaneous ignition are very complex, so it is difficult to prevent it beforehand and once it is difficult to digest it, it is difficult to digest it. This study examines structural safety by conducting a structural analysis of the cooling ball system to prevent spontaneous combustion of coal stockpile plants and external pressures.

Analysis on Information Use of Smartphone in the context of Tourists (관광객 대상 스마트폰 사용의 정보이용 분석)

  • Jee, Geun-Sung;Kim, Min-cheol;Ha, Tai-Hyun
    • Journal of Digital Contents Society
    • /
    • v.18 no.8
    • /
    • pp.1543-1550
    • /
    • 2017
  • Previous research on smartphone has been focused on personal performance, accessibility, and information gaps in information system quality. In order to analyze the relationship between the use of smartphone information and personal characteristics, this study conducted a survey of 300 tourists at Jeju Airport, by using three variables of self-efficacy, 'impulsiveness and demographic variables (age, sex, education level, etc.) of smartphone use with personal characteristics. In conclusion, self-efficacy and impulsiveness seem to be positively related to the use of smartphone because it seems to be a living environment in which the desired information can be acquired within a desired time. In addition, there seems to be a difference between a mobile native environment in which online and offline boundaries are always connected and an environment in which 40 to 50 digital literacies are connected. This can be interpreted as a result of additional analysis.

Evaluation of Electrochemical Properties of Amorphous LLZO Solid Electrolyte Through Li2O Co-Sputtering (Li2O Co-Sputtering을 통한 비정질 LLZO 고체전해질의 전기화학 특성 평가)

  • Park, Jun-Seob;Kim, Jong-Heon;Kim, Hyun-Suk
    • Korean Journal of Materials Research
    • /
    • v.31 no.11
    • /
    • pp.614-618
    • /
    • 2021
  • As the size of market for electric vehicles and energy storage systems grows, the demand for lithium-ion batteries (LIBs) is increasing. Currently, commercial LIBs are fabricated with liquid electrolytes, which have some safety issues such as low chemical stability, which can cause ignition of fire. As a substitute for liquid electrolytes, solid electrolytes are now being extensively studied. However, solid electrolytes have disadvantages of low ionic conductivity and high resistance at interface between electrode and electrolyte. In this study, Li7La3Zr2O12 (LLZO), one of the best ion conducting materials among oxide based solid electrolytes, is fabricated through RF-sputtering and various electrochemical properties are analyzed. Moreover, the electrochemical properties of LLZO are found to significantly improve with co-sputtered Li2O. An all-solid thin film battery is fabricated by introducing a thin film solid electrolyte and an Li4Ti5O12 (LTO) cathode; resulting electrochemical properties are also analyzed. The LLZO/Li2O (60W) sample shows a very good performance in ionic conductivity of 7.3×10-8 S/cm, with improvement in c-rate and stable cycle performance.

Evaluation of Ignition Performance of Green Hypergolic Propellant (친환경 접촉점화 추진제 점화 성능 평가)

  • Sunjin Kim;Minkyu Shin;Jeongyeol Cha;youngsung Ko
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.1
    • /
    • pp.51-58
    • /
    • 2023
  • Hypergolic propellants, which can ignite themselves without an ignition source, are difficult to handle due to their corrosiveness and toxicity. Therefore, it is necessary to develop green hypergolic propellants with little or no toxicity. In this study, basic research on green hypergolic ignition propellants was conducted. With 95% hydrogen peroxide as an oxidizer and CNU_HGFv1 as a fuel, ignition and combustion characteristics of propellants were evaluated through a drop test, an ignition test, and a combustion test. As a result of the drop test, the ignition delay time was 9.7 ms. It was 27 ms in the ignition test, which was fast enough to be used as a propellant. As a result of the combustion test, a combustion efficiency of 95.4~98.1% was achieved at about 11.7 bar. It was confirmed that fast and stable combustion was possible without hard start or combustion instability.

Monitoring Method Using Moving CCTV in Common Duct (이동형 CCTV 장치를 이용한 공동구 모니터링 방법)

  • Kang, Jin-A;Kim, Tae-Hoon;Oh, Yoon-Seuk;Choi, Hyun-Sang
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.14 no.4
    • /
    • pp.1-12
    • /
    • 2011
  • There has been the increasing concern with the safety of seven major urban infrastructure such as road, electricity, water supply, sewerage and so on due to urban expansion and new town development. However, high technology development for the common duct which can be an alternative for the safety issue has not been completed due to the law of the national security area. Existing management method of the common duct by people could not respond to the urgent accidents adequately and immediately since it is impossible for us to get access to that in case of fire or gas leak. This study suggests to the method of installing monitoring devices and processing CCTV images with a water supply in a TestLab(a variety of the USN(Ubiquitous Sensor Network) equipment was tested in the TestLab in KICT). The suggested management method of common duct facilities make it possible to do real-time monitoring and prompt access and response to an accident inside the common duct.

Hazardous and Noxious Substances (HNSs) Styrene Detection Using Spectral Matching and Mixture Analysis Methods (분광정합 및 혼합 분석 방법을 활용한 위험·유해물질 스티렌 탐지)

  • Jae-Jin Park;Kyung-Ae Park;Tae-Sung Kim;Moonjin Lee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.spc
    • /
    • pp.1-10
    • /
    • 2022
  • As the volume of marine hazardous and noxious substances (HNSs) transported in domestic and overseas seas increases, the risk of HNS spill accidents is gradually increasing. HNS leaked into the sea causes destruction of marine ecosystems, pollution of the marine environment, and human casualties. Secondary accidents accompanied by fire and explosion are possible. Therefore, various types of HNSs must be rapidly detected, and a control strategy suitable for the characteristics of each substance must be established. In this study, the ground HNS spill experiment process and application result of detection algorithms were presented based on hyperspectral remote sensing. For this, styrene was spilled in an outdoor pool in Brest, France, and simultaneous observation was performed through a hyperspectral sensor. Pure styrene and seawater spectra were extracted by applying principal component analysis (PCA) and the N-Findr method. In addition, pixels in hyperspectral image were classified with styrene and seawater by applying spectral matching techniques such as spectral distance similarity (SDS), spectral correlation similarity (SCS), spectral similarity value (SSV), and spectral angle mapper (SAM). As a result, the SDS and SSV techniques showed good styrene detection results, and the total extent of styrene was estimated to be approximately 1.03 m2. The study is expected to play a major role in marine HNS monitoring.

Development of FCEV accident scenario and analysis study on dangerous distance in road tunnel (도로터널에서 수소차 사고시나리오 개발 및 위험거리에 대한 분석 연구)

  • Lee, Hu-Yeong;Ryu, Ji-Oh
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.6
    • /
    • pp.659-677
    • /
    • 2022
  • Hydrogen is emerging as a next-generation energy source and development and supply of FCEV (hydrogen fuel cell electric vehicle) is expected to occur rapidly. Accordingly, measures to respond to hydrogen car accidents are required and researches on the safety of hydrogen cars are being actively conducted. In this study, In this study, we developed a hydrogen car accident scenarios suitable for domestic conditions for the safety evaluation of hydrogen car in road tunnels through analysis of existing experiments and research data and analyzed and presented the hazard distance according to the accident results of the hydrogen car accident scenarios. The accident results according to the hydrogen car accident scenario were classified into minor accidents, general fires, jet flames and explosions. The probability of occurrence of each accident results are predicted to be 93.06%, 1.83%, 2.25%, and 2.31%. In the case of applying the hydrogen tank specifications of FCEV developed in Korea, the hazard distance for explosion pressure (based on 16.5 kPa) is about 17.6 m, about 6 m for jet fire, up to 35 m for fireball in road tunnel with a standard cross section (72 m2).

Combustion Characteristics of Useful Imported Woods (국내 유용 해외 목재 수종의 연소특성 평가)

  • Seo, Hyun Jeong;Kang, Mee Ran;Park, Jung-Eun;Son, Dong Won
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.1
    • /
    • pp.19-29
    • /
    • 2016
  • The purpose of this study is to analyze the combustion and thermal properties in order to establish baseline data for the fire safety evaluation of imported wood. The combustion properties such as heat release rate, total heat release, gas yield, and mass loss were analyzed by the method of cone calorimeter test according to KS F ISO 5660-1 and thermogravimetric analysis (TGA). Analyzed species are five kinds of species as Merbau, Mempening, Garo Garo, Malas, and Dillenia. The heat released rate values showed the highest value of Malas as $375.52kW/m^2$, and Dillenia showed the lowest value as $133.30kW/m^2$. The data values were confirmed in the following order: Malas > Mempening > Garo Garo > Merbau > Dillenia. In case of the total heat release, it was measured in the following order: Mempening > Malas > Garo Garo > Merbau > Dillenia. The gas analysis results were that Dillenia showed the highest value of 0.034. Also, Mempening and Malas showed the lowest at 0.020 in the $CO/CO_2$. Min of mass reduction was shown as 74.79% Sargent cherry, on the other hand, Malas had a 83.52%. It showed a correlation between and of the CO and $CO_2$ generation and combustion characteristics of wood. The thermal decomposition temperature of the wood in the TGA were as follow that Merbau $348.07^{\circ}C$, Mempening $367.57^{\circ}C$, Garo Garo $350.59^{\circ}C$, Malas $352.41^{\circ}C$, Dillenia $364.33^{\circ}C$. The aim of this study is to determine the combustion properties of imported wood according to ISO 5660-1. And, based on the results of this study, we would proceed with further research for improving the fire safety of wood for construction.