• Title/Summary/Keyword: The causes of fire

Search Result 500, Processing Time 0.032 seconds

A Literature Study on Stercoremia(Fecal blood) (변혈(便血)에 대한 문헌적(文獻的) 고찰(考察))

  • Chang, Gyu-Tae;Kim, Jang-Hyun;Kim, Hee-Eun
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.18 no.1
    • /
    • pp.105-129
    • /
    • 2004
  • Methods: It was studied on the 47 kinds of oriental medical literature for fecal blood. Results: Fecal blood means bleeding with faces from anus and indicates all the three cases such as blooding before and after evacuation, evacuation of feces mixed with blood, and simple melena. The main causes are fire(火) and deficiency of spleen qi (脾氣虛). According to the color of fecal blood and the region of the bleeding, first, if the blood color is dark-red and blood discharges after emptying the bowels, it is called deposited poison into Jang(臟毒) or distant bleeding(遠血), and if the color of blood is clear and bowel emptying occurs after bleeding, it is bloody stool due to intestinal wind(腸風) or nearby bleeding(近血). For treating methods(治法). removing heat from the blood and stopping bleeding(淸熱凉血止血), removing dampness and stopping bleeding(淸熱除濕止血), invigorating Ki for promoting Hul-controJ(益氣攝血), warming the spleen and stomach to dispel cold and stopping bleeding(溫中散寒止血) etc are applied. As for the treating prescriptionl(治法), a Hwangtotang(黃土湯). Jeoksodudanggwitang(赤小豆當歸散). Gwihwasan(槐花散). Wipungtang(胃風湯). Hwangnyeonhwan modifying(黃連丸加減). Samultang modifying(四物湯加減). Paedoksan modifying(敗毒散加減) etc are used. As for acupuncture and moxibustion(鍼灸療法). if etiology(病因) is damp-heat(濕熱), acupuncture(刺鍼) at Janggang(長强); Charyo(BL 32); Sangeoheo(ST 37)(上巨虛); Seungsan(BL 57)(承山穴), and in case of deficiency of spleen Gi(脾氣虛), acupunture(刺鍼) with tonification(補法) at I Baek(EX-UE 2)(二白); Gwanwon(CC 4)(關元); Joksamni(ST 36)(足三里) Taebaek(SP 3)(太白); Hoeeum(CC 1)(會陰穴), or mxibuston(灸) at Baekoe(GC 2O)(百會); Myeongmun9GC (命門) or the point of opposite to umbilicus among spinal vertebrae(脊中對臍穴) are used. The external treatment(外治療法) was consisted of plastering umbilicus therapy(敷臍法) and enema therapy(灌腸法).

  • PDF

Analysis of the low-chapter prescription in 『Bangyakhappyun』 (『방약합편(方藥合編)』 하통(下統) 처방(處方)의 방제분석에 대한 고찰(考察))

  • Kim, Ae Wha;Cho, Jung Hoon;Jung, Chang Ohk;Han, Jong Hyun;Lim, Kyu Sang;Yun, Young Gab
    • Herbal Formula Science
    • /
    • v.26 no.2
    • /
    • pp.147-170
    • /
    • 2018
  • Objectivs : This report describes the studies as follows through the research of 163prescribtions in low-chapter from Bangyakhappyun. Methods : Analysis the 163prescribtions of basic prescribtions, therapeutic area, symptoms and pathology. Result : Many prescriptions are contained in the diseases areas such as defecate diseases, women diseases, internal diseases, exogenous febrile diseases. And prescriptions in the low-chapter are used in the areas such as eye, aggregation, mouth and tongue, teeth, hand, back, neck, emergency. Eighty-five basic prescriptions are analyzed from the low-chapter and the ratio of nineteen prescriptions containing Ijintang, Pyeongwisan, Oryungsan, Samultang, Sunggitang, Jichultang are over 60%. The efficacy classifications containing basic prescriptions frequently used are researched in the following order: heat-clearing and fire-purging formulae, digestant formulae, phlegm-dispelling formulae, qi-regulating formulae and blood-activating formulae. And tonifying and replenishing formulae are rarely used. Most of the prescriptions in the low-chapter are used for the excess syndrome and few of them are used for the deficiency syndrome. And six excesses, food damage, phlegm are the major causes of excess syndrome. Conclusions : As s result of study on analysis all prescriptions in low-chapter from Bangyakhappyun. We can understand more about basic prescriptions, symptoms of prescriptions and pathology.

Robust Design for Parts of Induction Bolt Heating System (유도가열시스템의 구성부품에 대한 강건설계)

  • Kim, Doo Hyun;Kim, Sung Chul;Lee, Jong Ho;Kang, Moon Soo;Jeong, Cheon Kee
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.2
    • /
    • pp.10-17
    • /
    • 2021
  • This paper presents the robust design of each component used in the development of an induction bolt heating system for dismantling the high-temperature high-pressure casing heating bolts of turbines in power plants. The induction bolt heating system comprises seven assemblies, namely AC breaker, AC filter, inverter, transformer, work coil, cable, and CT/PT. For each of these assemblies, the various failure modes are identified by the failure mode and effects analysis (FMEA) method, and the causes and effects of these failure modes are presented. In addition, the risk priority numbers are deduced for the individual parts. To ensure robust design, the insulated-gate bipolar transistor (IGBT), switched-mode power supply (SMPS), C/T (adjusting current), capacitor, and coupling are selected. The IGBT is changed to a field-effect transistor (FET) to enhance the voltage applied to the induction heating system, and a dual-safety device is added to the SMPS. For C/T (adjusting current), the turns ratio is adjusted to ensure an appropriate amount of induced current. The capacitor is replaced by a product with heat resistance and durability; further, coupling with a water-resistant structure is improved such that the connecting parts are not easily destroyed. The ground connection is chosen for management priority.

Real-time Intelligent Exit Path Indicator Using BLE Beacon Enabled Emergency Exit Sign Controller

  • Jung, Joonseok;Kwon, Jongman;Jung, Soonho;Lee, Minwoo;Mariappan, Vinayagam;Cha, Jaesang
    • International journal of advanced smart convergence
    • /
    • v.6 no.1
    • /
    • pp.82-88
    • /
    • 2017
  • Emergency lights and exit signs are an indispensable part of safety precautions for effective evacuation in case of emergency in public buildings. These emergency sign indicates safe escape routes and emergency doors, using an internationally recognizable sign. However visibility of those signs drops drastically in case of emergency situations like fire smoke, etc. and loss of visibility causes serious problems for safety evacuation. This paper propose a novel emergency light and exit sign built-in with Bluetooth Low Energy (BLE) Beacon to assist the emergency self-guiding evacuation using devices for crisis and emergency management to avoid panic condition inside the buildings. In this approach, the emergency light and exit sign with the BLE beacons deployed in the indoor environments and the smart devices detect their indoor positions, direction to move, and next exit sign position from beacon messages and interact with map server in the Internet / Intranet over the available LTE and/or Wi-Fi network connectivity. The map server generate an optimal emergency exit path according to the nearest emergency exit based on a novel graph generation method for less route computation for each smart device. All emergency exit path data interfaces among three system components, the emergency exit signs, map server, and smart devices, have been defined for modular implementation of our emergency evacuation system. The proposed exit sign experimental system has been deployed and evaluated in real-time building environment thoroughly and gives a good evidence that the modular design of the proposed exit sign system and a novel approach to compute emergency exit path route based on the BLE beacon message, map server, and smart devices is competitive and viable.

Implementation of Film Type Sensor for Synthetic Lube Oil and High Pressure Hydraulic Fluid Leak Detection (합성 윤활유 및 고압 작동유 누출감지 필름형 센서의 구현)

  • Park, No-Jin;Yu, Dong-Kuen;Yu, Hong-Kuen
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.266-271
    • /
    • 2014
  • Chemical sensors are used in various industrial facilities such high-risk and prevent the leakage of substances, important in life and environmental protection and the safe use of industry, used for management. In particular, high-temperature environments such as power generation equipment of the rotating part due to leakage generated by the various oil, power plants Shut Down, fire, work environment (exposure to various chemical solution and gas leak) and various water, air and soil pollution causes. Thus, over the long term through various channels such as crops and groundwater contamination caused by the slow, serious adverse effect on the ecosystem. In this paper, synthetic lube oil and high pressure hydraulic fluid leakage and immediately detect a new Printed Electronic implementation of technology-based film-type sensors, and its performance test. Thus, industrial accidents and environmental pollution and for early detection of problems, large accidents can be prevented. Experimental results of the synthetic lube oil and high pressure hydraulic fluid solution after the contact time depending on the experiment and the oil solution of the sensor material of the conductive porous PE resistance value by a chemical reaction could be confirmed that rapid increase. Also implemented in the film-type oil sensor electrical resistance change over time of the reaction rate and the synthetic lube oil is about 2 minutes or less, the high pressure hydraulic fluid is less than about 1 minute was. Therefore, more high-pressure hydraulic fluid such as a low volatility synthetic lube oils are the resistance change and the reaction rate was confirmed to be the slowest.

An Intersection Validation and Interference Elimination Algorithm between Weapon Trajectories in Multi-target and Multi-weapon Environments (다표적-다무장 환경에서 무장 궤적 간 교차 검증 및 간섭 배제 알고리즘)

  • Yoon, Moonhyung;Park, Junho;Yi, JeongHoon;Kim, Kapsoo;Koo, BongJoo
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.9
    • /
    • pp.614-622
    • /
    • 2018
  • As multiple weapons are fired simultaneously in multi-target and multi-weapon environments, a possibility always exists in the collision occurred by the intersection between weapon trajectories. The collision between weapons not only hinders the rapid reaction but also causes the loss of the asset of weapons of friendly force to weaken the responsive power against the threat by an enemy. In this paper, we propose an intersection validation and interference elimination algorithm between weapon trajectories in multi-target and multi-weapon environments. The core points of our algorithm are to confirm the possible interference through the analysis on the intersections between weapon trajectories and to eliminate the mutual interference. To show the superiority of our algorithm, we implement the evaluation and verification of performances through the simulation and visualization of our algorithm. Our experimental results show that the proposed algorithm performs effectively the interference elimination regardless of the number of targets and weapon groups by showing that no cross point exists.

Research on the Ejection Gas Generator to Improve Ejecting Performance (사출성능 개선을 위한 사출용 가스발생기 연구)

  • Oh, Seok-Jin;Jang, Seung-Gyo;Cha, Hong-Seok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.5
    • /
    • pp.383-390
    • /
    • 2013
  • The reduction of the maximum acceleration which causes shock for a missile is very important to prevent abnormal operation of a missile and decrease size and cost of missile components. Because the maximum acceleration created by operation of an ejection gas generator occurs in the initial ejection stage, the design parameters which affect initial ejection stage were examined. The igniter and the nozzle closure were selected as design parameters of a gas generator. The maximum acceleration created by the gas generator was examined experimentally by changing of the design parameters. Finally the reduction effect of the maximum acceleration was compared quantitatively by static fire test of a gas generator. The maximum acceleration of the best model which was applied to each optimal design parameter was about 68% reduced than that of the reference model.

A study on control method of DPF regeneration according to operation characteristics of Light Tactical Vehicle (전술차량 운용 특성에 따른 DPF 재생 제어 개선방안 연구)

  • Kim, Seon-Jin;Park, Jin-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.689-695
    • /
    • 2018
  • This paper presents the means of controlling the regeneration of a diesel particulate filter (DPF) that is mounted on tactical vehicles to satisfy exhaust gas standards. The DPF captures particulate matter in the exhaust gas and combusts the captured particulate matter. This process is regeneration, which is essential to the normal performance of the DPF. Bad regeneration causes degradation of vehicle performance; worse, it can lead to a vehicle fire. DPF regeneration is performed by control logic. If the regeneration control logic does not properly reflect the operating characteristics of the vehicle, DPF regeneration may not occur. Consequently, it is very important to ensure the DPF operates properly by reflecting the operating characteristics of the tactical vehicle. This study analyzes the operational characteristics of a tactical vehicle and the DPF, and adds proper DPF regeneration control logic. Additionally, this study is intended to simultaneously improve the additional problems that may occur from operating under the added regeneration control logic.

A study on Development way of 119 drowning rescue (119수난구조대의 현황 및 발전 방안)

  • Chong, Ji-Yon;Hwang, Hee-Jin;Kim, Gwang-Shok
    • The Korean Journal of Emergency Medical Services
    • /
    • v.9 no.1
    • /
    • pp.33-41
    • /
    • 2005
  • In Korea, the number of those who were drowned of the dead by 'accident and injury' ranked the third of causes of death is over 2,300 people a year. So the Ministry of Home Affairs arranged '119 drowning rescue team' at frequent occurrence regions of drowning temporarily as a part of drowning rescue measures during every summer season and made perfection more perfect for safety control and rescue services at prevention areas of accidents. However, considering that the number of professional drowning rescuers is small and it is managed temporarily only for summer, the placement of special rescue team equipped with professional education and qualification should be ensured and quick lifesaving and first-aid treatment should be conducted, since much time is required to arrive at accident place after receiving accident report at 119 office, rapid rescue and relief have not been achieved. Therefore, the placement of special rescue team should be increased for reducing the personal damages by considering regional characteristics and in particular placement of more drowning rescue teams in Jeonnam region which has more seas and rivers is needed This study aims at analyzing relief activities and statistics to cope with water accidents and achieve qualitative growth of first-aid services, examining actual conditions of water accident relief team and personnel assignment, providing first-aid services of good quality and establishing improvement methods to increase operation of relief team.

  • PDF

Analysis of Patients with Acute Industrial Toxic Exposure at an Emergency Department in an Industrial Complex (공단밀집지역에 위치한 일개 응급의료센터에 내원한 급성산업중독환자에 대한 분석)

  • Shin, Jun-Hyun;Moon, Sung-Woo;Baek, Seung-Won;Lim, Sung-Ik;Yoon, Young-Hun;Lee, Sung-Woo;Hong, Yun-Sik
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.6 no.2
    • /
    • pp.117-122
    • /
    • 2008
  • Purpose: Surveys on poisoning usually involves intoxication rather than inhalation, skin contact, etc. Therefore, we examined the characteristics of patients who visited the emergency department in an industrial complex after acute industrial exposure to toxic materials. Methods: Medical records of patients exposed to toxic materials in the work places from April, 2006, to March, 2008, were analyzed retrospectively. Inhalation patients due to fire were excluded. Results: Subjects included 66 patients, with a mean age of $35.4{\pm}10.9$ years, mostly men (91%). Toxicity occurred in 51 patients (77%) by contact, 15 patients (23%) by inhalation, and none by oral ingestion. For toxic materials, 10 patients were exposed to hydrofluoric acid, 8 to hydrochloric acid, 7 to sodium hydroxide, 7 to metals, and others. The face and hands were the most frequent exposure site by contact. Most exposures were caused by accidents, with 29 cases (42%) exposed because of carelessness or not wearing protective equipment. Most complaints were pain on exposure site, but 7 of the inhalation patients complained of dyspnea. The majority of patients with contact exposure were discharged after wound care or observation. After inhalation exposure, 1 patient died and 5 patients were admitted to the intensive care unit. Conclusion: Major causes of workplace exposure were not wearing protective equipment or carelessness. Although contact exposures are usually benign, cautious observation and management are required in patients with inhalation exposure.

  • PDF