• 제목/요약/키워드: Testing time

검색결과 3,688건 처리시간 0.038초

Applying Parallel Processing Technique in Parallel Circuit Testing Application for improve Circuit Test Ability in Circuit manufacturing

  • Prabhavat, Sittiporn;Nilagupta, Pradondet
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.792-793
    • /
    • 2005
  • Circuit testing process is very important in IC Manufacturing there are two ways in research for circuit testing improvement. These are ATPG Tool Design and Test simulation application. We are interested in how to use parallel technique such as one-side communication, parallel IO and dynamic Process with data partition for circuit testing improvement and we use one-side communication technique in this paper. The parallel ATPG Tool can reduce the test pattern sets of the circuit that is designed in laboratory for make sure that the fault is not occur. After that, we use result for parallel circuit test simulation to find fault between designed circuit and tested circuit. From the experiment, We use less execution time than non-parallel Process. And we can set more parameter for less test size. Previous experiment we can't do it because some parameter will affect much waste time. But in the research, if we use the best ATPG Tool can optimize to least test sets and parallel circuit testing application will not work. Because there are too little test set for circuit testing application. In this paper we use a standard sequential circuit of ISCAS89.

  • PDF

Low Cost Endurance Test-pattern Generation for Multi-level Cell Flash Memory

  • Cha, Jaewon;Cho, Keewon;Yu, Seunggeon;Kang, Sungho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제17권1호
    • /
    • pp.147-155
    • /
    • 2017
  • A new endurance test-pattern generation on NAND-flash memory is proposed to improve test cost. We mainly focus on the correlation between the data-pattern and the device error-rate during endurance testing. The novelty is the development of testing method using quasi-random pattern based on device architectures in order to increase the test efficiency during time-consuming endurance testing. It has been proven by the experiments using the commercial 32 nm NAND flash-memory. Using the proposed method, the error-rate increases up to 18.6% compared to that of the conventional method which uses pseudo-random pattern. Endurance testing time using the proposed quasi-random pattern is faster than that of using the conventional pseudo-random pattern since it is possible to reach the target error rate quickly using the proposed one. Accordingly, the proposed method provides more low-cost testing solutions compared to the previous pseudo-random testing patterns.

AUTOSAR 소프트웨어 컴포넌트의 유닛 테스트 방법 (Unit Testing for the AUTOSAR Software Component)

  • 금대현;이성훈;박광민;손병점
    • 한국정보과학회논문지:컴퓨팅의 실제 및 레터
    • /
    • 제16권11호
    • /
    • pp.1061-1065
    • /
    • 2010
  • 최근 세계 자동차 업계는 AUTOSAR 소프트웨어 플랫폼 표준을 제정하여 소프트웨어의 신뢰성과 재사용성을 향상키고 있다. 그러나 테스트 시스템 및 테스트 프로세스의 신뢰성 확보와 테스트에 소요되는 기간 단축을 위하여 테스트의 표준화 및 자동화가 절실하다. 특히 RTE 및 베이직 소프트웨어 모듈은 표준화를 만족하는 설계 도구를 사용함으로써 최소한의 신뢰성이 보장되지만, 여전히 응용 소프트웨어 컴포넌트에 대해서는 철저한 테스트가 필요하다. 본 논문에서는 표준화된 AUTOSAR 설계 정보를 이용하여 소프트웨어 컴포넌트의 유닛 테스트를 위한 테스트 시스템의 생성 및 테스트 케이스 생성 자동화 방법을 제안하였으며, 테스트 시스템은 TTCN-3 테스트 표준을 적용하였다. 본 논문에서 제안한 방법을 적용함으로써 차량 소프트웨어의 개발 기간 단축 및 신뢰성을 향상시킬 수 있었다.

PCB 검사기의 단락측정 알고리즘에 관한 연구 (A study on the short-open testing algorithm of the PCB tester)

  • 이용석;정화자;김용득
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.269-272
    • /
    • 1988
  • This paper deals with the test strategy on the short-open for the printed circuit board. A group testing algorithm, which is the several testing point to be measured redefined as one of the testing points, was suggested. As a result, the total testing time was reduced to 30${\sim}$50 percent.

  • PDF

Use of Fast Transfer Analysis Cartridges for Cervical Sampling and Real Time PCR Based High Risk HPV Testing in Cervical Cancer Prevention - a Feasibility Study from South India

  • Vijayalakshmi, Ramshankar;Viveka, Thangaraj Soundara;Malliga, JS;Murugan, Kothandaraman;Kanchana, Albert;Arvind, Krishnamurthy
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권14호
    • /
    • pp.5993-5999
    • /
    • 2015
  • Background: Molecular testing for human papillomavirus (HPV) is the most objective and reproducible of all cervical cancer screening tests and also less demanding in terms of training and quality assurance. However, there is an impending need for cost effective molecular HPV testing methods with sampling ease, easy storage measures and minimum turn around times suitable for a low resource setting. Objective : Our aim was to evaluate the feasibility of using a fast transfer analysis (FTA) mini elute cartridge for cervical sampling to identify high risk HPV by real time PCR and to compare molecular HPV testing and Pap cytology testing to predict histologically confirmed cervical precancer (CIN 2+ lesions) in a cervical cancer prevention program. Materials and Methods: This was conducted as a pilot study (n=200) on women sampled using FTA mini elute cartridges, genotyped by two different real time PCR assays, detecting 13 high risk HPV (HR HPV) species, including HPV16 along with its physical DNA status. Results obtained from each of the tests were compared and analysed using suitable statistical tests. Results: With FTA mini elute cartridge samples HR HPV positivity was seen in 48/200 (24%). Of these, presence of HPV 16 DNA was observed in 28/48 (58.3%) women. High risk HPV was positive in 20% (37/185) of women with benign cytology and 73.3% (11/15) of women with abnormal cytology findings. A very significant correlation (${\chi}^2=22.090$ ; p=0.000) was observed between cytology and HR HPV findings showing an increasing trend of HR HPV prevalence in 50% (1/2) of LSIL, 75% (3/4) of HSIL and 100% (3/3) of SCC. Of the CIN 2+ lesions identified by histopathology, 88.9% (8/9) had HR HPV. A significant association (${\chi}^2=11.223$ ; p=0.001) of HR HPV and histopathologically confirmed CIN 2+ lesions was found. Sensitivity of the two tests were comparable but specificity of Pap testing was better (90.7% vs 70.4%) to predict histopathologically diagnosed cervical precancers. Conclusions: The current study explored the feasibility of using a FTA mini elute cartridge for cervical sampling for the first time in India as a part of a community based cervical cancer prevention program. We suggest that FTA based sampling is suitable and feasible for real time based HPV testing. Molecular HR HPV testing can be more sensitive and useful to identify high risk women requiring Pap testing which is more specific to detect histologically confirmed cervical precancer.

넓은 대역 광원을 이용한 광 가입자 선로 운용보전 시스템에 관한 연구 (A Study on the operation and Maintenance system for optical subscriber loops using a broadband light source)

  • 이용기;이영호;박봉근
    • 한국통신학회논문지
    • /
    • 제25권3B호
    • /
    • pp.504-509
    • /
    • 2000
  • This paper presents a noble operation and maintenance system for the optical subscriber loops and its feasibility through several experiments. In this system, a broadband CW (Continuous Wave) light source I used as monitoring of testing signals. and a FGF(Fiber Grating Filter) of which reflective wavelength is independent, is inserted somewhere in each subscriber loop for the reflection of monitoring of testing signals. The propose of the system is quick decision. whether the loop is just fault or not. rather than detailed information of loop state. At present, most of operation and maintenance system for the optical subscriber loops adopts OTDR(optical time domain reflectometer) for testing function. the OTDR is useful for detailed test, but not adequate for simple test because of long testing time . And it is difficult to test PON network by using general OTDR that has a single-wavelength light source. Compared to using OTDR, the proposed system can afford to shorten testing time and to test PON network. Moreover, we can cut down the system cost by simplifying circuits of the optical light sources. Our results show that the proposed system operates well according to the purpose mentioned above.

  • PDF

대형 MR감쇠기가 설치된 건축구조물의 실시간 하이브리드 실험 및 준능동 알고리즘 적용 (Real-time Hybrid Testing a Building Structure Equipped with Full-scale MR dampers and Application of Semi-active Control Algorithms)

  • 박은천;이성경;이헌재;문석준;정형조;민경원
    • 한국전산구조공학회논문집
    • /
    • 제21권5호
    • /
    • pp.465-474
    • /
    • 2008
  • 실시간 하이브리드 실험법(real-time hybrid testing method)은 구조물의 수치해석부와 실험부 부분구조를 운동방정식으로 통합하여 실시 간으로 동시에 계산과 실험을 수행하는 방법이다 본 연구는 실시간 하이브리드 실험법을 사용하여 수동 및 준능동 MR감쇠기가 설치된 건축구조물의 내진성능을 정량적으로 평가한다. 건물 모델은 실물 크기 5층 건물을 강제진동실험 결과를 통해 식별한 수치모델로 사용하였고, MR감쇠기는 실험적 부분구조르 UTM에 설치되었다. 본 연구에서 수행되는 실시간 하이브리드 실험은 사인파 및 지진파 가진을 통하여 얻은 결과와 전류에 따른 MR감쇠기의 제어력을 이용하여 얻은 Bouc-Wen모델을 사용하여 얻은 해석모델과 일치함으로 그 유효성을 입증하였다. 또한 예비연구로써 구조물의 응답을 최적으로 제어하기 위한 clipped-optimal 제어알고리즘과 modulated homogeneous friction 준능동 제어알고리즘을 MR감쇠기에 적용하였다. 각 전류별 Bouc-Wen모델을 곡선맞춤하여 각각의 Bouc-Wen모델 파라미터를 식별하였으며 그 결과를 준능동 제어알고리즘 수치해석에 적용하였다. 또한 실시간 하이브리드 실험법을 이용한 준능동 제어 실험결과와 해석결과를 비교하여 준능동 제어알고리즘의 성능을 평가함에 있어 실시간 하이브리드 실험이 합리적임을 보여준다.

설계사양기반 RF 집적회로의 시간영역 테스팅 기법 (The time domain testing technique of RFIC based on specifications)

  • 한석붕;백한석;김강철
    • 대한전자공학회논문지SD
    • /
    • 제43권5호
    • /
    • pp.34-47
    • /
    • 2006
  • 본 논문에서는 무선 트랜시버 구성소자들의 완제품 테스팅을 용이하게 할 수 있는 새로운 테스팅 기법을 제안하였다. 즉 RF 집적회로에 존재하는 고장들에 대하여 설계사양의 정보를 포함하는 구간고장모델(band fault model)을 제안하고 이 구간고장모델들의 변화를 회로의 출력에서 그대로 관찰할 수 있도록 함으로써 시간영역에서 설계사양에 대한 테스트를 용이하게 할 수 있는 방식을 제시하였다. 이 방식은 주파수 영역에서 테스트를 행하는 기존의 설계사양 테스트를 시간영역에서 용이하게 테스트할 수 있도록 함으로써 고가의 테스트 장비가 필요 없으며 테스트 시간이 단축되는 장점이 있다. 본 논문에서 제시된 테스팅 기법을 5.25 GHz 저잡음증폭기의 테스트에 적용하여 설계사양을 고려한 시간영역 테스팅 기법이 저잡음증폭기를 비롯한 RF 집적회로의 테스트에 매우 효과적임을 입증하였다.

시간영역 자장 적분방정식을 이용한 유전체의 전자파 산란 과도해석 (Transient Analysis of Electromagnetic Scattering From Dielectric Objects Using Time-Domain Magnetic Field Integral Equation)

  • 서정훈;정백호;한상호;안현수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권9호
    • /
    • pp.412-417
    • /
    • 2003
  • In this Paper, we propose a time-domain magnetic field integral equation (TD-MFIE) formulation for analyzing the transient electromagnetic response from three-dimensional (3-D) dielectric bodies. The solution method in this paper is based on the Galerkin's method that involves separate spatial and temporal testing procedures. Triangular patch basis functions are used for spatial expansion and testing functions for arbitrarily shaped 3-D dielectric structures. The time-domain unknown coefficients of the equivalent electric and magnetic currents are approximated tv a set of orthonormal basis function that is derived from the Laguerre polynomials. These basis functions are also used for the temporal testing. Numerical results computed by the proposed method are presented and compared.

일정 변형률 시험에 의한 TRIP강의 수소 지연파괴 특성연구 (Study on the Hydrogen Delayed Fracture Property of TRIP Steel by Slow Strain Rate Testing Method)

  • 조정현;이종권
    • Corrosion Science and Technology
    • /
    • 제10권4호
    • /
    • pp.131-135
    • /
    • 2011
  • The demands of high-strength steel have been steadily increased to reduce the weight of vehicles. Although the TRIP steel has been the promising candidate material for the purpose, high strength hinders the application due to the susceptibility to hydrogen delayed fracture in the corrosive environment. Moreover, the testing method was not specified in the ISO standards. In this work, the test method to evaluate the susceptibility of hydrogen delayed fracture was studied by slow strain rate testing technique. The four test experimental parameters were studied : strain rate, hydrogen charging time, holding time after hydrogen charging, and holding time after cadmium plating. The steel was fractured by hydrogen in case the strain rate was in the range of $1{\times}10^{-4}{\sim}5{\times}10^{-7}/sec$. It was confirmed that the slow strain rate test is effective method to evaluate the susceptibility to hydrogen delayed fracture. The holding time over 24 hrs after hydrogen charging, nullified the hydrogen effect, that is, the specimen was no more susceptible to hydrogen after 24 hrs even though the specimen was fully hydrogen-charged. Moreover, cadmium electroplating could not prevent from diffusing out the hydrogen from the steel in the experiment. The effective experimental procedures were discussed.