• Title/Summary/Keyword: Testing time

Search Result 3,700, Processing Time 0.036 seconds

The Method of Determining Stress Levels Regarding the Electrical ALT through Optical Temperature Sensor

  • Ryu, Haeng-Soo;Han, Gyu-Hwan;Yoon, Nam-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.2
    • /
    • pp.184-191
    • /
    • 2008
  • Electrical endurance is the critical characteristic of Magnetic contactors(MCs), which are widely used in such power equipment as elevators, cranes, and factory control rooms in order to close and open control circuits. Testing time, however, is not short in typical cases in which some method of reducing the testing period is required. This study shows the method of determining the stress level of electrical ALT(Accelerated Life Test) through optical temperature sensor and the relationship between 0.05 s and 0.1 s for on-time. The tool used for analyzing the test result is MINITAB. I will propose the method of determining the optimized stress level through optical temperature sensor, which will contribute to minimize the testing time and development period and also raise the product reliability.

Assessments for MGARCH Models Using Back-Testing: Case Study (사후검증(Back-testing)을 통한 다변량-GARCH 모형의 평가: 사례분석)

  • Hwang, S.Y.;Choi, M.S.;Do, J.D.
    • The Korean Journal of Applied Statistics
    • /
    • v.22 no.2
    • /
    • pp.261-270
    • /
    • 2009
  • Current financial crisis triggered by shaky U.S. banking system adds to the emphasis on the importance of the volatility in controlling and understanding financial time series data. The ARCH and GARCH models have been useful in analyzing economic time series volatilities. In particular, multivariate GARCH(MGARCH, for short) provides both volatilities and conditional correlations between several time series and these are in turn applied to computations of hedge-ratio and VaR. In this short article, we try to assess various MGARCH models with respect to the back-testing performances in VaR study. To this end, 14 korean stock prices are analyzed and it is found that MGARCH outperforms rolling window, and BEKK and CCC are relatively conservative in back-testing performance.

The Effectiveness of Blood β-ketone Testing in Patients with Diabetic Ketosis: A Systematic Review & Meta-analysis (당뇨환자에서 자가관리형 베타케톤검사의 유효성: 체계적 문헌 고찰 및 메타분석)

  • Mo, Jin A;Jang, Sunyoung;Bang, Hee Young
    • Korean Journal of Health Education and Promotion
    • /
    • v.31 no.4
    • /
    • pp.1-10
    • /
    • 2014
  • Objectives: The effectiveness of Blood ${\beta}$-ketone testing by using self-monitoring strip on diabetic patients. Methods: Clinical effectiveness of blood ${\beta}$-ketone testing was assessed through correlation with reference test that measured blood ${\beta}$-ketone value through gas chromatography or enzyme method, diagnostic accuracy, time taken for the test and time taken for confirmative diagnosis of diabetic ketosis by selecting literatures on researches that conducted this test on ketosis(suspected) patients or diabetic ketosis(suspected) patients. Each of the stages from literature search to application of selection standards and extraction of data were carried out independently by the Subcommittee along with 2 researchers. Results: 7 reports were selected. ${\beta}$-ketone testing displayed high level of correlation in the range of r=0.92~0.99 with test using enzyme method as the reference standard. Regarding the diagnostic accuracy, sensitivity of 0.82, specificity of 0.74. The time taken for the test was 30seconds for the index test, which is shorter than reference standard test. Conclusion: Blood ${\beta}$-ketone testing was assessed to be a safe and effective test to monitor ketosis and assess the level of risk of ketosis by measuring the blood ${\beta}$-ketone on ketosis patients and diabetic ketosis patients since it has high level of correlation with reference test and short period of testing.

New Randomness Testing Methods using Approximate Periods (근사 주기를 이용한 새로운 랜덤성 테스트 기법)

  • Lim, Ji-Hyuk;Lee, Sun-Ho;Kim, Dong-Kyue
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.16 no.6
    • /
    • pp.742-746
    • /
    • 2010
  • In this paper, we propose new randomness testing methods based on approximate periods in order to improve the previous randomness testing method using exact pattern matching. Finding approximate periods of random sequences enables us to search similarly repeated parts, but it has disadvantages since it takes long time. In this paper we propose randomness testing methods whose time complexity is O($n^2$) by reducing the time complexity of computing approximate periods from O($n^3$) to O($n^2$). Moreover, we perform some experiments to compare pseudo random number generated by AES cryptographic algorithms and true random number.

The Comparative Study for Property of Learning Effect based on Truncated time and Delayed S-Shaped NHPP Software Reliability Model (절단고정시간과 지연된 S-형태 NHPP 소프트웨어 신뢰모형에 근거한 학습효과특성 비교연구)

  • Kim, Hee Cheul
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.8 no.4
    • /
    • pp.25-34
    • /
    • 2012
  • In this study, in the process of testing before the release of the software products designed, software testing manager in advance should be aware of the testing-information. Therefore, the effective learning effects perspective has been studied using the NHPP software. The finite failure nonhomogeneous Poisson process models presented and applied property of learning effect based on truncated time and delayed S-shaped software reliability. Software error detection techniques known in advance, but influencing factors for considering the errors found automatically and learning factors, by prior experience, to find precisely the error factor setting up the testing manager are presented comparing the problem. As a result, the learning factor is greater than autonomous errors-detected factor that is generally efficient model can be confirmed. This paper, a failure data analysis was performed, using time between failures, according to the small sample and large sample sizes. The parameter estimation was carried out using maximum likelihood estimation method. Model selection was performed using the mean square error and coefficient of determination, after the data efficiency from the data through trend analysis was performed.

Re-ignition System using Vacuum Triggered Gap-switch for Synthetic Breaking Test

  • Park Seung-Jae;Suh Yoon-Taek;Kim Dae-Won;Kim Maeng-Hyun;Song Won-Pyo;Koh Hee-Seog
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.4
    • /
    • pp.145-151
    • /
    • 2005
  • The synthetic breaking test method was developed to evaluate the breaking performance of ultra high-voltage circuit breaker and made up of two independent circuits; current source circuit and voltage source circuit. In application of this test method, it is necessary to extend the arc of the test breaker. So, the new re-ignition system using VTGS (Vacuum Triggered Gap-Switch) was constructed to improve the efficiency and reliability of this test. In this re-ignition system, VTGS operates in high vacuum state of $5{\time}10^{17}$torr and control system consists of the triggering device and the air M-G (Motor-Generator). This re-ignition system showed the operating characteristics, such as delay time ($t_d$) and jitter time ($t_j$ not exceeding 5us and 1us respectively, and had the operating voltage of $25\~150kVdc$ at the gap distance of 24mm.

Manufacturing and Characteristics Analysis of a Testing Device for the Evaluation of a Distribution Board Management System (분전반 관리시스템 평가를 위한 시험 장치의 제작 및 특성 분석)

  • Ko, Wan Su;Lee, Byung Seol;Choi, Chung Seog
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.31-36
    • /
    • 2019
  • This study made a testing device to evaluate the distribution board management system. Power was supplied to the testing device using a loading-back method and the voltage applied to it was 440 V at the same turn ratio. When the human body electric shock current is 30 mA, the breaking time is set to be less than 240 ms while 30~45 mA current is flowing. The test result shows that in the case of the R-phase it was measured to be 5.19 Hz (193 ms). And the S-phase and T-phase were perfectly cut off at 5.39 Hz (186 ms) and 5.71 Hz (175 ms), respectively. When the human body electric shock current is 60mA, the breaking time is set to be less than 120 ms while 45~75 mA current is flowing. The test result shows that the R-phase, S-phase, and T-phase were accurately cut off at 8.39 Hz (11 ms), 8.87Hz (113 ms) and 9.69 Hz (103 ms), respectively. When the human body electric shock current is 90 mA, the breaking time is set to be less than 48 ms while 75 mA current is flowing. The test result shows that the R-phase, S-phase, and T-phase were accurately cut off at 19.8 Hz (50.4 ms), 16.9 Hz (59.2 ms), and 17.9 Hz (56.0 ms), respectively. That is, the developed testing device satisfied all the requirements of the distribution board evaluation criteria, and it becomes available for the performance evaluation of the distribution board management system.

Evaluation of the Reliability of Salivary Testing Instrument (타액검사기의 신뢰도 평가)

  • Han, Keumah;Lee, Joonhaeng
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.3
    • /
    • pp.363-369
    • /
    • 2018
  • A salivary testing instrument has an advantage that the method is simple and can be performed in a short time. However, it is necessary to verify the factors that affect the reliability of the result, because the device is easy to use and even saliva collection is simple. The aim of this study was to compare the difference of the test results according to the measurement time in order to analyze the time factor of the external variable among the factors that may affect the measurement results of the salivary testing instrument. The relationship between the measured values of the salivary testing instrument to identify the internal variables was analyzed. Saliva was collected from 20 randomly selected patients regardless of age, sex, or diseases. The mean age was 46.6 years, 10 males and 10 females. The saliva collected was directly measured with the salivary testing instrument as group I. The saliva samples were placed in air in a paper cup for 10 minutes, and then measured as group III. Then group I was remeasured after 30 minutes and assigned as group II. Group III was remeasured after 30 minutes and called as group IV. As a result, all of the cariogenic bacteria, acidity, buffer capacity, blood, leukocyte, protein and ammonia, except buffer capacity, showed statistically significant changes in group II and IV. This means that the reliability of the test results is poor if the measurement time is not observed. Cariogenic bacteria were correlated with leukocyte and protein, buffer capacity was related to acidity, protein, and protein was related to buffer capacity and leukocyte. In conclusion, the result according to the measurement time as the external variable was different, which means that time must be strictly monitored when testing saliva. It is also necessary to take into account the relevance of the correlations between the internal variables and the clinical data.

Time Reversal Beam Focusing of Ultrasonic Array Transducer on a Defect in a Two Layer Medium

  • Jeong, Hyun-Jo;Lee, Jeong-Sik;Bae, Sung-Min
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.3
    • /
    • pp.242-247
    • /
    • 2009
  • The ability of time reversal techniques to focus ultrasonic beams on the source location is important in many aspects of ultrasonic nondestructive evaluation. In this paper, we investigate the time reversal beam focusing of ultrasonic array sensors on a defect in layered media. Numerical modeling is performed using the commercially available software which employs a time domain finite difference method. Two different time reversal approaches are considered - the through transmission and the pulse-echo. Linear array sensors composed of N elements of line sources are used for signal reception/excitation, time reversal, and reemission in time reversal processes associated with the scattering source of a side-drilled hole located in the second layer of two layer structure. The simulation results demonstrate the time reversal focusing even with multiple reflections from the interface of layered structure. We examine the focusing resolution that is related to the propagation distance, the size of array sensor and the wavelength.

Conformance Test Scenario Extraction Techniques for Embedded Software using Test Execution Time (테스트 수행시간을 고려한 임베디드 소프트웨어의 적합성 테스트 시나리오 추출 기법)

  • Park, In-Su;Shin, Young-Sul;Ahn, Sung-Ho;Kim, Jin-Sam;Kim, Jae-Young;Lee, Woo-Jin
    • The KIPS Transactions:PartD
    • /
    • v.17D no.2
    • /
    • pp.147-156
    • /
    • 2010
  • Conformance testing for embedded software is to check whether software was correctly implemented according to software specification or not. In conformance testing, test scenarios must be extracted to cover every test cases of software. In a general way, test scenarios simply focus on testing all functions at least one time. But, test scenarios are necessary to consider efficiency of test execution. In this paper, we propose a test scenario extraction method by considering function's execution time and waiting time for user interaction. A test model is a graph model which is generated from state machine diagram and test cases in software specification. The test model is augmented by describing test execution time and user interaction information. Based on the test model, test scenarios are extracted by a modified Dijkstra's algorithm. Our test scenario approach can reduce testing time and improve test automation.