• 제목/요약/키워드: Test apparatus

검색결과 984건 처리시간 0.024초

치과용 시술기구(Micro Handpiece)재료의 특성평가 및 표면품질에 대한 연구 (Study on Evaluation of Material Property of Micro Handpiece for dentistry and Surface Quality)

  • 손재환;한창우;최상일;김용중;최창진
    • 한국산업융합학회 논문집
    • /
    • 제9권3호
    • /
    • pp.221-228
    • /
    • 2006
  • As Industrialization gets more and more advanced, human technological medical apparatus for dentistry has been developed. Such a medical apparatus have to let precision revolution and torque control facilitate. Consequently, Development of Micro hand-piece with strong durability should be required. Moreover, It's also very important to evaluate performance of such a Micro hand-piece, Evaluation of Mechanical property of Material and ANOVA have been known as useful methods in the field of Quality Evaluation. For Verification of Quality Evaluation, It has been evaluated by One-way layout ANOVA based on the data of Surface Roughness Test. Anyhow, This test has been respectively carried out by 3 kinds of Test and Superior performance has appeared in the Test result.

  • PDF

초고압 절연시험을 위한 4.2MV 충격전압발생장치의 구축방안 검토 (A preliminary study on the construction of 4.2MV IVG for the UHV dielectric test)

  • 이정기;신영준;허종철;문인욱;김맹현;강영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1750-1752
    • /
    • 2003
  • This paper, as a preliminary study, presents the important consideration in laboratory planning and designing 4.2MV impulse voltage generator(IVG), which enable to test and evaluate the UHV dielectric performance of power electric apparatus up to 765kv-class. To fix and confirm the kinds of loads and their capacities to be tested by KERI hereafter, wide investigation and an analysis of test objects, especially heavy electric apparatus of Korea, according to their ratings and test voltages have been conducted. With the special consideration concerning other matters in designing of 4.2MV IVG have been described with the practical examples and references.

  • PDF

중발포 소화약제 소화성능 분석을 통한 중발포기 적용에 관한 연구 (A Study on the Application Medium Expansion Foam Extinguisher by a Fire Performance Analysis used Medium Expention Foam Agent)

  • 이장원
    • 한국재난정보학회 논문집
    • /
    • 제15권3호
    • /
    • pp.402-408
    • /
    • 2019
  • 연구목적 : 포소화설비에 사용되는 중발포 소화약제는 기류에 영향이 적어 방출거리를 유지 할 수 있을뿐만 아니라 소화약제도 효율적으로 사용 할 수 있기 때문에 중발포기를 이용하여 발포배율 및 소화성능을 실험으로 밝히고자 한다. 연구방법 : 본 연구를 위해 중발포 시험장치를 제작하여, 합성계면활성 제포를 대상으 로 유류화재(B급) 소화성능 및 발포배율 분석과 포소화약제 소모량을 측정하고 분석하였다. 연구결과: 중발포기로 발포배율을 측정한 결과 팽창율이 26.1배의 중발포 배율로 나타났으며, 유류화재 20단위 소화모형 실험결과 소화시간이 고발포 및 저발포 보다 빠르게 나타나, 수동식설비인 호스릴 또는 중발포기 적용이 가능할 것으로 본다. 결론: 본 연구를 통해 중발포 포소화약제 발포성능 및 소화성능이 우수하게 나타나는 점을 고려하여 중발포 소화약제를 활용한 호스릴 또는 중발포기의 기술기준 도입이 필요하다.

48개 채널의 GM Tube 센서 테스터 장치의 설계 (Design of Tester Apparatus for 48 Channel GM Tube Sensor)

  • 이희열;이주현;이승호
    • 전기전자학회논문지
    • /
    • 제20권3호
    • /
    • pp.310-313
    • /
    • 2016
  • 본 논문에서는 48개 채널의 GM Tube 센서 테스터 장치를 설계한다. 제안하는 장치는 48 채널의 GM Tube 센서들을 동시에 테스트하여 불량의 여부 및 센서 특성을 분석한다. 시간의 변화에 따라 달라지는 센서의 특성에 적합한 300 ~ 1000V의 가변 고전압을 발생할 수 있는 회로로 센서의 특성을 분석한다. 따라서 다양한 종류의 GM Tube 센서의 특성 분석에 용이하게 사용된다. 제안하는 장치를 통해 대량의 GM Tube를 동시에 테스트 할 수 있는 환경이 구축되어 센서의 불량 여부 및 센서의 특성을 미리 파악하여 생산 및 재작업 등에 소요되는 비용을 대폭 줄일 수 있다. 개발된 48 채널 GM Tube 센서 테스터 장치의 측정 불확도에 대하여 공인 시험기관의 장비를 사용하여 실험한 결과 우수한 성능을 나타내었다.

Does Competency, Commitment, and Internal Control Influence Accountability?

  • HARDININGSIH, Pancawati;UDIN, Udin;MASDJOJO, Greg. N.;SRIMINDARTI, Ceacilia
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제7권4호
    • /
    • pp.223-233
    • /
    • 2020
  • This study aims to analyze the influence of apparatus resources, organizational commitment, internal control on the accountability of village fund allocations with the level of education as a moderating. Accountability analysis of village fund allocation is carried out at every stage of planning, implementation stage, administration stage, reporting stage, and accountability stage. The study was conducted in 18 villages in Undaan District, Kudus Regency - Indonesia, with a total sample of 115 village officials. Structural Equation Model analysis techniques with Warp Partial Least Square were used to test the research hypotheses. The results showed that apparatus resources, organizational commitment, and internal control had a positive effect on the accountability of village fund allocations. The level of education strengthens the influence of apparatus resources on the accountability of village fund allocations. The findings of the study further prove that commitment has positive implications for achieving accountability. It means that the higher the commitment made by the government apparatus, the better and higher the effect on accountability in managing public funds. With an ethical commitment of the government apparatus in managing the budget, the use of funds can be in accordance with the planning and designation so that goals can be achieved.

실기체급 비행체 모델에 대한 M4 준자유류 시험 (M4 Semi-Freejet Test with Full-scale Vehicle Model)

  • 배주현;임창원;최호진;진상욱;김정우
    • 한국추진공학회지
    • /
    • 제26권5호
    • /
    • pp.63-73
    • /
    • 2022
  • 국내 설비를 활용하여 실기체급 비행체 모델에 대한 M4 준자유류 시험을 수행하였다. 시험장치 및 비행체 모델은 반복적인 전산유체해석을 통해 통합적으로 설계/제작되었고, 해당 설비를 목표 시험 조건까지 가동하여 시험장치의 M4 노즐이 완전히 팽창하는 것을 확인하였다. 비행체 모델의 흡입구 주변의 가시화 영상을 획득하여 경사충격파가 생성되면서 비행체의 흡입구가 시동하는 것을 관측하였다. 비행체의 가변노즐을 구동하여 배압을 조절하면서 비행체 내부 유로의 벽면 압력 분포를 획득하였고, 연소기 내 화염안정화장치에서 점화용 토치 점화 및 점화보조제의 연소 현상을 관측하였다.

현미경 진단용 슬라이드 제작을 위한 단층세포 흡착장치 개발 (Development of Mono Layer Cell Adsorption Apparatus to Create a Slide for Microscopic Diagnosis)

  • 오한영;문민기;김성현;김동욱;강소미;성락경;김현창
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권1호
    • /
    • pp.1-6
    • /
    • 2015
  • This study aims to design a monolayer cell adsorption apparatus that would help to produce high-quality slides for Liquid-Based Cytology (LBC) of an early cancer diagnosis for human bodies. The LBC collects exfoliated cells of human bodies and spreads the cells on the slides. Through processes of dyeing and cytological examination, the LBC screens for cancers in early stage. In this study, both of a cell suction module and a cell adsorption module, which are the key elements of the monolayer cell adsorption apparatus, were developed, and using those modules, the study set, first, conditions to help both GYN and NON-GYN apply principal cells without de-endothelialization before conducting its own analysis on the utility. As a results, for GYN, apparatus was determined to be able to produce high-quality slides under the condition of 4 and for NON-GYN, the apparatus would come up with other slides of high-quality under the condition of 2. The study carried out a repetitive test on selected conditions and proved 96% of the repetitive success rate. By the results of what has been learned so far, the study presents that the apparatus has a possibility to replace device from South Korea as one of those other currently-applied systems to run the LBC and that the system will also present a new paradigm for cancer diagnosis as it makes a contribution to the improvement in the LBC.

탈곡기의 선별 성능을 측정하는 방법의 개발에 관한 연구 (Development of Method for Measuring the Grain Separating Performance of Threshers)

  • 이승기;정창주
    • 한국농공학회지
    • /
    • 제17권1호
    • /
    • pp.3655-3665
    • /
    • 1975
  • This study was intended to develop a method for measuring the grain separating performance of threshers. The grain separating apparatus used for the experiment was designed and constructed, the function of which was to separate pneumatically mature and immature grain, chaff, straw, dust, and other impurities from the products of threshing. The apparatus has five material outlets where grains and impurities are fallen down by separation depending upon the specific gravity of the material white it moves above the outlets. The principle of design was to separate the mixture of mature grain, immature grain and chaff as distinct as possible, and to induce the mature grains onto the first outlet, the immature grains onto the second and the third, and the straw wastes onto the forth and the fifth outlets. The developed apparatus was tested to evaluate its separating performance with two rice varieties (Tongil and Mine-hikari) at different moisture levels and air velocities. The optimum conditions for operating the apparatus were found from experiment. The results are summarized as follows; 1. The degrees of separation, especially the amount of immature grain contained in the mature paddy, were dependent upon air speed delivered. The optimum air velocities for this apparatus for each levels of grain moisture contents were found from a series of experiments as follows; 14.7-15.3m/sec. for grain of 16 percent moisture content in wet basis, 15.3-16.0m/sec. for 20 percent, and 16.0-16.4m/sec for 24 percent. 2. Composition ratios determined based on the brine separating method was fairly well acted upon the developed apparatus, indicating its recollecting rate of the mature grains as 97.6 to 99.9 percent. The developed separatus acted similarly upon the two rice varieties which had different composition of immature paddy grain. In other words, the separating performance by the apparatus had a good correlation with the one by the brine separating method. 3. As immature grains were separated out unsatisfactory in these experiments than the brine separating method, further investigation may be needed to improve a separating performance of these materials. But the results obtained suggested a possibility of using the tester to replace the current hand separating method, ther eby enabling more consistent test results and also eliminating nearly all costly hand seperating operations.

  • PDF

3차원 안면 자동 인식기(3D-FARA)의 안면 위치변화에 따른 정확도 검사 (Precision Test of 3D Face Automatic Recognition Apparatus(3D-FARA) by Rotation)

  • 석재화;조경래;조용범;유정희;곽창규;이수경;고병희;김종원;김규곤;이의주
    • 사상체질의학회지
    • /
    • 제18권3호
    • /
    • pp.57-63
    • /
    • 2006
  • 1. Objectives The Face is an important standard for the classification of Sasang Contitutions. Now We are developing 3D Face Automatic Recognition Apparatus to analyse the facial characteristics. This apparatus show us 3D image of man's face and measure facial figure. We should examine accuracy of position recognition in 3D Face Automatic Recognition Apparatus. 2. Methods We took a photograph of Face status with Land Mark 8 times using Face Automatic Recognition Apparatus. Each taking-photo, We span Face statusby 10 degree. At last time, We took a photograph of Face status's lateral face. And We analysed Error Averige of Distance between seven Land Marks. So We examined the accuracy of position recognition in 3D Face Automatic Recognition Apparatus at indirectly in degree changing of Face status. 3. Results and Conclusions According to degree change of Face status, Error Averige of Distance between Seven Land Marks is 0.1848mm. In conclusion, We assessed that accuracy of position recognition in 3D Face Automatic Recognition Apparatus is considerably good in spite of degree changing of Face status

  • PDF

다중체 낙하법에 의한 상대밀도 재현에 관한 연구 (The Reapperarance of Relative Density by the Multiple Sieving Pluviation Method)

  • 주재우;곽정민
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1994년도 가을 학술발표회 논문집
    • /
    • pp.265-272
    • /
    • 1994
  • The relative density seems to be important as a factor of controlling the physical properties in the case of cohesionless soil ground as sand. Therefore, the study is more important about the method for reappearing the same relative density when the specimen of shearing test is to be produced or the model test of ground is to be made. In this study, the apparatus making use of the multiple sieving pluviation method - one of the reappearance of relative density - could be made. Using this apparatus, tests were practiced varying the factors such as the size of sieve mesh and the number of sieve, the amount of falling discharge, the falling height etc. about the standard sand in Jumunjin and Hadong sand. When laboratory test is performed by the cohensionless soil , it presents the method for reappearing of the relative density in field.

  • PDF