• Title/Summary/Keyword: Temperature Lift

Search Result 162, Processing Time 0.029 seconds

Evaluation on the Creep Life Prediction Using Initial Strain Method (초기 연신율법을 이용한 크리프 수명예측 평가)

  • Kong, Yu-Sik;Lim, Man-Bae;Lee, Sang-Pill;Yoon, Han-Ki;Oh, Sae-Kyoo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.6
    • /
    • pp.1069-1076
    • /
    • 2002
  • The high temperature creep behavior of heat machine systems such as aircraft engines, boilers and turbines in power plants and nuclear reactor components have been considered as an important and needful fact. There are considerable research results available for the design of high temperature tube materials in power plants. However, few studies on the Initial Strain Method (ISM) capable of securing repair, maintenance, cost loss and life loss have been made. In this method, 3 long time prediction Of high temperature creep characteristics can be dramatically induced through a short time experiment. The purpose of present study is to investigate the high temperature creep lift of Udimet 720, SCM 440-STD61 and 1Cr-0.5Mo steel using the ISM. The creep test was performed at 40$0^{\circ}C$ to $700^{\circ}C$ under a pure loading. In the prediction of creep life for each materials, the equation of ISM was superior of Larson-Miller Parameter(LMP). Especially, the long time prediction of creep life was identified to improve the reliability.

A Study on Operating Characteristics of Heat Pump System Using Sea Water Sources (해수온도차에너지이용 냉난방시스템 운전특성에 관한 연구)

  • Chang, Ki-Chang;Baik, Young-Jin;Yoon, Hyung-kee;Ra, Ho-Sang
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.422-425
    • /
    • 2009
  • A sea water source cascade heat pump was designed and tested in this study. The system was designed to perform a single stage operation in summer, as well as a cascade operation in winter to ensure the high temperature lift. A steady-state simulation model was developed to analyze and optimize its performance. The simulation results show that the R717 exhibits best performance among combinations considered in this study. A R410A also exhibits the highest performance among HFCs with the smallest compressor displacement. A 15-RT R410A-R134a pilot system was installed in the 5-story commercial building at Samcheok City by the East Sea. A scroll type R410A compressor, a reciprocating type R134a compressor, plate type condenser/evaporator/ cascade heat exchanger and two electronic expansion valves were used to build a pilot. A titanium plate type heat exchanger is also used for the heat exchanging with a sea water. The heat source/sink water is supplied from the well below the seashore in the depth of 5 m. In the initial test of the system, supply water temperature was rising up to $67^{\circ}C$ using a sea water heat source of $9^{\circ}C$, while an ambient temperature was $4.5^{\circ}C$.

  • PDF

Study on Fuel Consumption Improvement in SI Engine with EGR for Hybrid Electric Vehicle (하이브리드용 가솔린엔진의 EGR을 통한 연비향상에 관한 연구)

  • Park, Cheol-Woong;Choi, Young;Kim, Chang-Gi
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.2
    • /
    • pp.128-135
    • /
    • 2008
  • EGR(exhaust gas recirculation) is considered as a most effective method to reduce the NOx emissions. But high EGR tolerance is always pursued not only for its advantages of the pumping loss reduction and fuel economy benefit in Gasoline-Hybrid engine. However, the occurrence of excessive cyclic variation with high EGR normally prevents substantial fuel economy improvements from being achieved in practice. Therefore, the optimum EGR rate should be carefully determined in order to achieve low fuel consumption and low exhaust emission. In this study, 2 liters gasoline engine with E-EGR system was used to investigate the effects of EGR on fuel efficiency, combustion stability, engine performance and exhaust emissions. With optimal EGR rates, the fuel consumption was improved by 4%. This improvement was achieved while a reduction in NOx emissions of 75% was accomplished. Increase of EGR gas temperature causes the charge air temperature to affect the knock phenomenon and moreover, the EGR valve lift changes for the same control signal.

High Temperature Creep Rupture Characteristics of Ni-Based Alloy718 (니켈기 초내열합금 Alloy718의 고온 크리프 파단 특성)

  • Kwon, Sang-Woo;Kong, Yu-Sik;Kim, Seon-Jin
    • Journal of Ocean Engineering and Technology
    • /
    • v.22 no.6
    • /
    • pp.52-57
    • /
    • 2008
  • The short-term high temperature creep rupture behavior of Ni-based Alloy718 steel was investigated at the elevated temperatures range of 550 to $700^{\circ}C$ under constant stress conditions. The creep rupture characteristics such as creep stress, rupture time, steady state creep rate, and initial strain were evaluated. Creep stress has a quantitative correlation between creep rupture tim and steady state creep rate. The stress exponents (n, m) of the experimental data at 550, 600, 650 and $700^{\circ}C$ were derived as 33.5, -24.9, 26.1, -21.2, 16.8, -12.8 and 10, -8.2, respectively. The stress exponent decreased with increasing creep temperature. The creep lift prediction was derived by the Larson-Miller parameter (LMP) method and the resultant equation was obtained as follows: T($logt_r$+20)=-0.00252 ${\sigma}^2$-1.377${\sigma}$+-22718.

Comparison of Cardiopulmonary Effects and Recovery between Total Intravenous Anesthesia with Propofol and Volatile Induction/maintenance Anesthesia with Isoflurane in Beagle Dogs (비글견에서 Propofol 완전정맥마취와 Isoflurane 휘발성 유도/유지 마취 시 심폐기능과 회복의 비교)

  • Lee Soo-Han
    • Journal of Veterinary Clinics
    • /
    • v.22 no.3
    • /
    • pp.259-263
    • /
    • 2005
  • To compare cardiopulmonary effects and recovery between total intravenous anesthesia (TIVA) with propofol (PRO group, n=5) and volatile induction/maintenance anesthesia (VIMA) with isoflurane (ISO group, n=5), we investigated changes of heart rate, $SpO_2$, arterial pressure, rectal temperature and respiratory rate during 60 minute anesthesia and 40 minute recovery period in beagle dogs, and investigated recovery (extubation, head lift, sternal position and righting) after 60 minute anesthesia. Rectal temperature was significantly low in ISO group (p<0.05) from 10 to 100 minute. Heart rate was significantly low in ISO group (p<0.05) at 40, 50, 60 minute. Respiratory rate was significantly low in PRO group (p<0.05) at induction and 70 minute. $SpO_2$ tendency was similar. Systolic arterial pressure (SAP) was significantly low in ISO group (p<0.05) at induction and during anesthesia. Recovery was similar in two groups. We concluded that TIVA with propofol is useful in stabilizing rectal temperature and arterial pressure during anesthesia and provide fast and stable recovery.

Reducing Thermal Cracking of Mat-foundation Mass Concrete Applying Different Mix Designs for Upper and Lower Placement Lifts (상하부 배합을 달리함에 의한 기초 매트 매스콘크리트의 수화열 균열저감)

  • Han, Cheon-Gu;Kim, Min-Ho
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.1
    • /
    • pp.39-46
    • /
    • 2017
  • In this research, considering the practical conditions at field, thermal cracking reducing method was suggested based on the comparative analysis between predicted value and actual value obtained from the actual structure member with optimum mix design. The optimum mix design was deduced from the various mix designs with various proportions of cementitious binder for upper and lower placement lifts of mat-foundation mass concrete. Therefore, before field applications, the mix designs were obtained from the theoretical analysis obtained by MIDAS GEN for upper lift was OPC to FA of 85 to 15, and for lower lift was OPC to FA to BS of 50 : 20 : 30. Based on this mix design, the actual concrete for field was determined and all concrete properties were reached within the predicted range. Especially, the temperature properties of mass concrete at core was approximately $39^{\circ}C$ of temperature difference for low-heat mix design, while approximately $54^{\circ}C$ was shown for normal mix design currently used. Additionally, in the case of cracking index, the low heat mix design showed about 1.4 of relatively high value while the normal mix design showed 1.0. Therefore, it can be stated that applying low heat mix design and different heating technique between upper and lower placement lifts for mass concrete are efficient to control the thermal cracking.

Simulation of a Double Effect Double Stage Absorption Heat Pump for Usage of a Low Temperature Waste Heat (저온 폐열 활용을 위한 2중 효용 2단 흡수식 히트펌프 시뮬레이션)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.11
    • /
    • pp.7736-7744
    • /
    • 2015
  • Considering the significant waste of industrial energy, effective use of low temperature waste heat is extremely important. In this study, a heat pump cycle with double effect and double stage was realized, which escalates the hot water temperature from $50^{\circ}C$ to $70^{\circ}C$ using $160^{\circ}C$ high temperature heat source and $17^{\circ}C$ low temperature heat source. The steam generated in the first generator condenses in the first condenser generating steam in the second generator. The steam condenses in the second condenser and is provided to the second evaporator. Part of the water out of the second evaporator is supplied to the first evaporator, which evaporates using low temperature waste heat. The evaporated steam enters the first absorber and the second evaporator. The steam out of the second evaporator is absorbed into the solution at the second absorber. The hot water temperature is raised in the second condenser and in the second absorber. Proper flow rates and UA values, which satisfied temperature lift $20^{\circ}C$ and COP 1.6, were deduced through trior and error. The COP increases as the temperature of the high temperature water increases, hot water temperature decreases and flow rate increases, waste water temperature and flow rate increases, solution circulation rate decreases. On the other hand, the temperature rise of the hot water increases as the temperature of the high temperature water increases, hot water temperature increases and flow rate decreases, waste water temperature and flow rate increases, solution circulation rate increases. In addition, the COP and hot water temperature rise increase as UAs of the heat exchangers increase.

Solder Bump Deposition Using a Laser Beam (레이저빔을 이용한 솔더범프 적층 공정)

  • Choi, Won-Suk;Kim, Jea-Woon;Kim, Jong-Hyeong;Kim, Joo-Han
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.1
    • /
    • pp.37-42
    • /
    • 2012
  • LIFT (laser-induced forward transfer) is an advanced laser processing method used for selectively transferring micron-sized objects. In our study, this process was applied in order to deposit solder balls in microsystem packaging processes for electronics. Locally melted solder paste could be transferred to a rigid substrate using laser pulses. A thin glass plate with a solder cream layer was used as a donor film, and an IR laser pulse (wavelength = 1070 nm) was used to transfer a micron-sized solder ball to the receptor. Mass balance and energy balance were applied to analyze the shape and temperature profiles of the solder paste drops. The transferred solder bumps had measured diameters of 30-40 ${\mu}m$ and thicknesses of 50 ${\mu}m$ in our experiment. The limits and applications of this method are also presented.

Fabrication of Nanopatterns for Biochip by Nanoimprint Lithography (나노임프린트를 이용한 바이오칩용 나노 패턴 제작)

  • Choi, Ho-Gil;Kim, Soon-Joong;Oh, Byung-Ken;Choi, Jeong-Woo
    • KSBB Journal
    • /
    • v.22 no.6
    • /
    • pp.433-437
    • /
    • 2007
  • A constant desire has been to fabricate nanopatterns for biochip and the Ultraviolet-nano imprint lithography (UV-NIL) is promising technology especially compared with thermal type in view of cost effectiveness. By using this method, nano-scale to micro-scale structures also called nanopore structures can be fabricated on large scale gold plate at normal conditions such as room temperature or low pressure which is not possible in thermal type lithography. One of the most important methods in fabricating biochips, immobilizing, was processed successfully by using this technology. That means immobilizing proteins only on the nanopore structures based on gold, not on hardened resin by UV is now possible by utilizing this method. So this selective nano-patterning process of protein can be useful method fabricating nanoscale protein chip.

Prediction Method of End of Charge Voltage using Battery Parameter Measurement (배터리 파라미터 측정을 이용한 충전종지전압 예측기법)

  • Kim, Ho-Yong;Wang, Yi-Pei;Park, Seong-Mi;Park, Sung-Jun;Son, Gyung-Jong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.3
    • /
    • pp.387-396
    • /
    • 2022
  • Recently, e-Mobility, which is a personal mobility device such as an electric bicycle or an electric scooter, is rapidly emerging. However, since E-Mobility has various voltage systems due to the characteristics of its products, it is essential for companies that operate them to use multiple dedicated chargers. A universal charger capable of charging batteries of various voltage systems with one charger is required to reduce the cost of purchasing and managing multiple dedicated chargers. For this, information on the EOC(End of Charge) is essential. In order to know the EOC, it is necessary to detect the internal impedance of the battery. However, the internal impedance of the battery changes according to various conditions such as SOH(State Of Health), SOC(State Of Charge), and ambient temperature. By observing the change in these parameters, the state of the battery can be diagnosed and the EOC can be predicted. In this paper, we propose an algorithm to analyze the battery's internal impedance and to predict the EOC, in order to acquire information on the EOC of the battery, which is an essential requirement of a universal charger.