1 |
Shim, Y. S., A Study on the Absorption Heat Pump for Waste Heat Recovery, Ph. D. Thesis, Incheon National University, 2014.
|
2 |
Harold, K. E., Radermacher, R. and S. A. Klein, Absorption Chillers and Heat Pumps, 1st ed., CRC Press, 1996.
|
3 |
EES, F-Charts Software, www.fchart.com, 2015.
|
4 |
Park. I. W., Park, J. T. and Yoo, S. Y., "An investigation on the domestic industrial waste heat", Korean J. Air-Conditioning Refrigeration Engineering, Vol. 14, No. 10, pp. 811-816, 2002.
|
5 |
Park, Y. S., "Technology trends on the recovery of waste heat and unused energy using a heat pump", Ministry of Science of Technology, 2011.
|
6 |
Ma, X., Chen, J., Li, S., Sha, Q., Liang, A., Li, W., Zhang, J., Zheng, G. and Feng, Z., "Application of absorption heat transfer to recover waste heat from a synthetic rubber plant", Applied Thermal Engineering Vol. 23, pp. 797-806, 2003. DOI: http://dx.doi.org/10.1016/S1359-4311(03)00011-5
DOI
|
7 |
Grossman, G. and Childs, K. W., "Computer simulation of a lithium bromide-water absorption heat pump for temperature boosting", ASHRAE Trans., Vol. 89, Part 1, pp. 240-250, 1983.
|
8 |
Perez-Blanco, H. and Grossman, G., "Conceptual design and performance analysis of absorption heat pumps for waste heat utilization", ASHRAE Trans., Vol. 88, Part 1, pp. 451-466, 1982. DOI: http://dx.doi.org/10.1016/0140-7007(82)90058-5
|
9 |
Grossman, G., "Adiabatic absorption and desorption for improvement of temperature-boosting absorption heat pumps", ASHRAE Trans., Vol. 88, Part 2, pp. 359-367, 1982.
|
10 |
Grossman, G., "Multistage absorption heat transformers for industrial applications", ASHRAE Trans., Vol. 91, Part 2, pp. 2047-2061, 1985.
|
11 |
Grossman, G. and Michelson, E., 1"A modular computer simulation of absorption systems" ASHRAE Trans., Vol. 91, Part 2B pp. 1808-1827, 1985.
|
12 |
Youn, C. H., "Development of a absorption heat pump for recovery of low temperature waste heat", KIMM, 1989.
|
13 |
Kang, S. W., Kang, B. H., Jeong, S. Y. and Lee, C. S., "Computer simulation of a absorption heat pump of the first kind for low temperature waste heat recovery", Korean J. Air-Conditioning Refrigeration Engineering, Vol. 8, No. 2, pp. 187-197, 1996.
|
14 |
Lee, Y. H., Shin, H. J., Youn, H. C. and Park H. K., "A study on the heating and cooling system using sewage heat", J. Korean Solar Energy Society, Vol. 27, No. 4, pp. 19-26, 2007.
|
15 |
Greiter, I., Schweigler, C., and Alefeld, G., "A 500kW absorption heat pump for heating at two temperature levels : Experience of the first heating season", Proc. Int. Absorption Heat Pump Conference, AES-Vol. 31, pp. 85-92, New Orleans, USA, 1994.
|
16 |
World Energy Co., internal performance data, 2015.
|