A study on the Optimum Design Configuration of Passive Solar TI-wall system (투명단열재가 적용된 축열벽 시스템의 최적구성 선정에 관한 연구)

  • Kim, Byoung-Soo;Yoon, Jong-Ho;Yoon, Yong-Jin;Baek, Nam-Choon
    • KIEAE Journal
    • /
    • v.3 no.2
    • /
    • pp.37-44
    • /
    • 2003
  • The aim of this study was to analyze the thermal performance through Test-Cell of TI-wall in domestic climate. This study was carried out as follows: 1) The TI-wall was studied for ability to reduce heat loss through the building envelope and analyzed to TIM properties. 2) Test models of TI-wall were designed through the investigation of previous paper and work, measured for winter and spring, and the thermal effects were analyzed. The type of the TIM used in test model is small-celled(diameter 4mm and thickness 50mm) capillary and cement brick(density $1500kg/m^3$) was used by thermal mass. 3) Test-cell of TI-wall was calibrated from measured data and the dynamic simulation program ESP-r 9.0. In these simulations, the measured climate conditions of TaeJon were used as outdoor conditions, and the simulation model of Test-cell was developed. 4) The sensitivity analysis is executed in various aspects with standard weather files and ESP-r 9.0, and then most suitable system of TI-wall are predicted. Finally, The suitable system of TI-wall was analysed according to sizes of air gap, kinds, thickness, and the surface absorption of therm wall. The result is following. In TI-wall, Concrete is better than cement brick, at that time the surface absorption is 95%, and the most efficient thickness is 250mm. As smaller of a air gap, as reducer of convection heat loss, it is efficient for heating energy. However, ensuring of a air gap at least more than 50mm is desirable for natural ventilation in Summer.

Thermal Performance of TI-wall System (투과형단열재 부착 건물외피구조체의 열성능)

  • Yoon, Yong-Jin;Kim, Hea-Jeong;Kim, Byoung-Soo
    • KIEAE Journal
    • /
    • v.4 no.3
    • /
    • pp.121-128
    • /
    • 2004
  • One of the most weak parts for energy loss through the whole building components are building envelopes. Lots of technbologies to increase the thermal performance of building envelopes have been introduced in recent years. Transparent insulation is a new technology for building insulation and has function both solar transmittance and thermal insulation. This study has been carried out to develope the transparent insulation panels and TI-wall system and to analyze the thermal performance of TI-wall system by experiments using test-cell and dynamic energy simulation program ESP-r 9.0. This system is regarded as a efficient building envelope system suitable for to reduce the heating and cooling load of the buildings in our country.

The Thinning Phenomena of the Wall Thickness during $360^{\circ}$ Cold Bending of Ti-6Al-4V Large-Diameter Seamless Tube (대 직경 이음매 없는 Ti-6Al-4V 합금 튜브의 $360^{\circ}$ 냉간 굽힘 시 벽두께 감소현상)

  • 허선무;박종승
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.3 no.1
    • /
    • pp.231-236
    • /
    • 2000
  • The wall thickness of the Ti-6Al-4V Large-Diameter Seamless Tube, which is supposed to be a very important parameter in a system design, was measured during $360^{\circ}$ cold bending processes. The factors or processes affecting the wall thickness include 1) primary bending, 2)secondary or finishing step of the $360^{\circ}$ bending, 3)cleaning processes in CERO TRUTM(CT)process. But thinning effects of the wall thickness during the cleaning processes are negligible compared to those during the formers. The variations in the percentages of the change in wall thickness were found to be from -14% to +16%.

  • PDF

Antiferromagnetically Exchange-coupled Two Phase Magnets: Co/Co2TiSn

  • Kim, Tae-Wan;Oh, Jung-Keun
    • Journal of Magnetics
    • /
    • v.13 no.2
    • /
    • pp.43-52
    • /
    • 2008
  • The objective of this paper is to review the magnetic and magneto-transport properties of Co/$Co_2TiSn$ consisting of two metallic magnetic phases that are antiferromagnetically exchange-coupled at the phase boundary. The bulk Co/$Co_2TiSn$ system, which has a $Co_2$TiSn Heusler alloy precipitates in the hexagonal Co matrix, showed an unusual coercivity change with a concurrent change in temperature, and was modeled on the basis of a wall formation caused by exchange coupling at the phase boundary. For measurements of magneto-transport properties, Co/$Co_2TiSn$ thin films that had two-magnet phases were deposited using a magnetron sputtering system with a composite target. The magnetization process in the films is also explained on the basis of the model of wall formation at the phase boundary. Annealed Co/$Co_2TiSn$ films showed a 0.12% GMR effect, indicating the scattering of polarized conduction electrons due to the antiparallel exchange coupling at the phase boundary. The scattering process of conduction electrons at the phase boundary was modeled with relation to the magnetization process.

Arc Ion Plating Deposition System의 Bias 종류에 따른 TiN 박막의 특성평가

  • Kim, Wang-Ryeol;Park, Min-Seok;Kim, Dae-Yeong;Kim, Hyeon-Seung;Gwon, Min-Cheol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.208-208
    • /
    • 2012
  • 최근 환경문제가 많이 제기되면서 친환경적 운송수단인 자전거 개발과 관련하여 다양한 기술개발이 이루어지고 있다. 그 중 고부가가치의 서스펜션 포크의 프레임에 고기능성 표면처리로 Arc ion plating deposition system (AIPDS)을 이용하여 부식, 내마모 특성이 뛰어난 TiN 박막을 증착시켰다. AIPDS는 기존의 arc system과 달리 다원계 소재 코팅 공정조건 확립을 위하여 chamber wall에 2개의 rectangular type sputter source를 장착하고 소재의 pre-treatment 용 linear type ion source를 설치하였다. 장비의 Chamber 중앙에는 pipe형 arc cathode를 설치하였으며, 그 주위를 anode 역할을 하는 copper 코일로 감아 이는 발생한 arc를 target인 cathode 축을 중심으로 방향성을 가지고 회전하여 진행 할 수 있도록 유도 하였다. 이 시스템에서 증착된 TiN 박막은 bias 전압 변화에 따른 박막의 구조 및 물성을 평가하였다. XRD 장비를 통하여 TiN 박막의 상분석을 진행하였고, 마모테스터, 원자현미경, 마이크로 비커스 경도기 등을 이용하여 기계적 특성을 평가하였다.

  • PDF

Development of Thermal Properties on the Roof Waterproof with Insulation System using the Diffused Reflection Material (확산반사를 이용한 경질시트 옥상 단열방수공법의 열성능 개선에 관한 연구)

  • Koo, Jae-Oh
    • KIEAE Journal
    • /
    • v.7 no.1
    • /
    • pp.73-80
    • /
    • 2007
  • This paper aims to develop the diffused reflection material in order to reduce the solar absorption coefficient, and to compare the thermal properties with the different roof structure system; one is using the diffused reflection material applied the upper side of the rigid sheet waterproof system and the other is using the conventional up-side down waterproof system on the roof. For this purpose two experimental test boxes were made of same iso-panel wall and floor with different roof system. The experiment was carried out under these process; measure the surface temperature exposed solar radiation of the variation of the reflection materials(cement paste, silica, galvanized steel and titanium dioxide(TiO2)), measure and analyze the variation of the temperature distribution of the each roof system and indoor air in order to evaluate the thermal properties according to the different roof system. The result shows clearly that using the titanium dioxide(TiO2) might be more effective to reduce the solar insolation.

Thermal Performance Evaluation Monitoring Study of Transparent Insulation Wall System (투명단열 축열벽 시스템의 열성능 평가 실험 연구)

  • Kim, B.S.;Yoon, J.H.;Yoon, Y.J.;Baek, N.C.;Lee, J.S.
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.1
    • /
    • pp.1-8
    • /
    • 2003
  • Various efforts to combine new high-tech materials with solar system have been progressed nowadays in order to improve the performance of the existing passive solar system. TIM(Transparent Insulation Material) replacing the conventional outer building envelope glazing as well as the wall is good example for this trend. TI integrated wall is a thermal mass wall with a special shaped TIM instead of using typical envelope materials The tested TIM type is a small(diameter 4mm and thickness 50mm) capillary tube of Okalux model and cement brick(density 1500kg/m3). The purpose of this study was to analyze the thermal performance through the actual measurements performed in a test cell. This study was carried out to justify the following issues. 1) the impact of Tl-wall over the temperature variations 2) the impact of mass wall surface absorptance over the transient thermal behavior and 3) the impact of thermal mass wall thickness over the temperature variations. Finally, as results indicated that the peak time of room temperature was shifted about one hour early when absorptance of thermal mass wall changed from 60% to 95% for the 190mm thickness thermal mass wall test case. the temperature difference of both surfaces of thermal mass wall surface showed about $23^{\circ}C$ during a day of March for the 380mm thickness thermal mass wall case. However, the thermal mass wall was over-heated by outside temperature and solar radiation in a day of May the temperature difference of both surfaces of thermal mass wall surface was indicated $10^{\circ}C$ and inside temperature was observed more than average 22C.

Effect of ZnO and TiO2 Nanopaticles (NPs) on Microorganisms Growth in Activated Sludge (활성슬러지에서의 미생물 성장에 대한 ZnO와 TiO2 나노물질의 영향)

  • Ha, Min Jeong;Lee, Yeo Eun;Jang, Am
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.4
    • /
    • pp.177-183
    • /
    • 2016
  • Sewage treatment using microorganisms is affected by multiple factors such as microbial properties, characteristics of sewage and operating conditions, and nanoparticles inflow may cause negative effects on sewage treatment system especially on the system stability and efficiency. It was studied to assess the toxic effects of nanoparticles on microorganism growth. The activated sludge in the sewage treatment plant of university was cultured in the optimized medium for each strain. Bacillus (gram-positive), Pseudomonas and E.coli (gram-negative) in the activated sludge were selected as target microorganisms, and ZnO and $TiO_2$ were chosen as nanoparticles. For same concentration of nanoparticles, average growth inhibition rate of Bacillus was 60% or more, while that of Pseudomonas was less than 10%. The toxicity of nanoparticles was shown to be higher for gram-positive bacteria than gram-negative bacteria because of their differences on structure of cell wall, components of cell wall protein, physiology of cells and metabolism. ZnO affected 3 times more negative on the growth of microorganisms as compared to $TiO_2$. It was assumed that, therefore, toxicity of ZnO was found to be greater than $TiO_2$.

Aging Behavior and Electric Field Induced-Domain Stabilization in Cr2O3 Doped Pb(Zr0.525 Ti0.475)O3 System (Cr2O3첨가 Pb(Zr0.525 Ti0.475)O3계에서의 시효거동과 전계유도 Domain 안정화)

  • 한이섭;김호기
    • Journal of the Korean Ceramic Society
    • /
    • v.24 no.5
    • /
    • pp.477-483
    • /
    • 1987
  • Cr2O3 doped Pb(Zr0.525 Ti0.475)O3 piezoelectric ceramics were prepared from reagent grade oxide mixture, PbO, ZrO2, TiO2 and Cr2O3. Piezoelectric and aging properties of specimens were measured for various additions of Cr2O3. Generally, it has been known that aging rate decreased with Cr2O3 addition by stabilizing the domain wall. But hysteresis loops showed that the domain destabilization was occurred at high electric field (larger than 10KV/cm). In smaller additions of Cr2O3 (0-0.2mol%), aging rate increased and microcracks were created with increasing poling filed due to increasing internal stress. In larger additions of Cr2O3(0.4∼0.6mol%), aging rate decreased with increasing poling field.

  • PDF

Collapse Mechanism of Ordinary RC Shear Wall-Frame Buildings Considering Shear Failure Mode (전단파괴모드를 고려한 철근콘크리트 보통전단벽-골조 건물의 붕괴메커니즘)

  • Chu, Yurim;Kim, Taewan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.25 no.1
    • /
    • pp.1-9
    • /
    • 2021
  • Most commercial buildings among existing RC buildings in Korea have a multi-story wall-frame structure where RC shear wall is commonly used as its core at stairways or elevators. The members of the existing middle and low-rise wall-frame buildings are likely arranged in ordinary details considering building occupancy, and the importance and difficulty of member design. This is because there are few limitations, considerations, and financial burdens on the code for designing members with ordinary details. Compared with the intermediate or unique details, the ductility and overstrength are insufficient. Furthermore, the behavior of the member can be shear-dominated. Since shear failure in vertical members can cause a collapse of the entire structure, nonlinear characteristics such as shear strength and stiffness deterioration should be adequately reflected in the analysis model. With this background, an 8-story RC wall-frame building was designed as a building frame system with ordinary shear walls, and the effect of reflecting the shear failure mode of columns and walls on the collapse mechanism was investigated. As a result, the shear failure mode effect on the collapse mechanism was evident in walls, not columns. Consequently, it is recommended that the shear behavior characteristics of walls are explicitly considered in the analysis of wall-frame buildings with ordinary details.