Browse > Article

Thermal Performance Evaluation Monitoring Study of Transparent Insulation Wall System  

Kim, B.S. (Graduate School, Chungnam National University)
Yoon, J.H. (Department of Architecture, Hanbat National University)
Yoon, Y.J. (Korea Institute of Energy Research)
Baek, N.C. (Korea Institute of Energy Research)
Lee, J.S. (Department of Architecture, Chungnam University)
Publication Information
Journal of the Korean Solar Energy Society / v.23, no.1, 2003 , pp. 1-8 More about this Journal
Abstract
Various efforts to combine new high-tech materials with solar system have been progressed nowadays in order to improve the performance of the existing passive solar system. TIM(Transparent Insulation Material) replacing the conventional outer building envelope glazing as well as the wall is good example for this trend. TI integrated wall is a thermal mass wall with a special shaped TIM instead of using typical envelope materials The tested TIM type is a small(diameter 4mm and thickness 50mm) capillary tube of Okalux model and cement brick(density 1500kg/m3). The purpose of this study was to analyze the thermal performance through the actual measurements performed in a test cell. This study was carried out to justify the following issues. 1) the impact of Tl-wall over the temperature variations 2) the impact of mass wall surface absorptance over the transient thermal behavior and 3) the impact of thermal mass wall thickness over the temperature variations. Finally, as results indicated that the peak time of room temperature was shifted about one hour early when absorptance of thermal mass wall changed from 60% to 95% for the 190mm thickness thermal mass wall test case. the temperature difference of both surfaces of thermal mass wall surface showed about $23^{\circ}C$ during a day of March for the 380mm thickness thermal mass wall case. However, the thermal mass wall was over-heated by outside temperature and solar radiation in a day of May the temperature difference of both surfaces of thermal mass wall surface was indicated $10^{\circ}C$ and inside temperature was observed more than average 22C.
Keywords
TIM; Thermal storage effect; Thermal mass-wall;
Citations & Related Records
연도 인용수 순위
  • Reference
1 A, Haller, H.J. Althaus, 'Gain Control for Solar Wall Heating With Transparent Insulation(TI) Requirements for Cost Effecctive Applications of Natural Ventilation in Multi-functional and Ventilated Facades (MFVF), EuroSun 2000
2 Liisa Rautiainen, 'Transparent Thermal In-su1ation(TIM)-Performance properties', ETTR-research program funding by Ministry of Trande and Industry Energy Department. 1992
3 김세환, 김삼열, 이성, '투명 단열외피를 통한 환기효과에 관한 연구', 태양에너지학회논문집 Vol 20. No 4. 2000
4 유승호, 윤용진 '투과형 단열시스뎀의 투과 및 단열특성 평가' 대한건축학회계획계논문집 18권4호, 2002. 4
5 A. Beck, M. Reim, W. Korner, J. Fricke, 'Highly Insulating Aerogel Glazing', EuroSun 2000
6 이성, '투명단열된 불투명 외피에서의 에너지 흐름'. 태양에너지학회논문집, Vol16. No.3 1996
7 Bruno Peuportier, Jacques Michel., 1995, 'Comparative Analysis of Active and Passive Solar Heating Systems with Transparent Insulation' Solar Energy, Vo1.54, No.l. pp13-18   DOI   ScienceOn