• Title/Summary/Keyword: System Characteristic Constant

Search Result 268, Processing Time 0.025 seconds

A Constant Current Regulated Inverter System for Lighting and Beaconing of Aerodromes (항공관제용 정전류조정(CCR) 인버터 시스템의 개발)

  • Shon, Jin-Geun;Park, Jong-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2006.10b
    • /
    • pp.141-146
    • /
    • 2006
  • According as level of industry develops day after day, electricity load system of industry requires high level control, effectiveness and high efficiency. Among supply and control unit of suitable power supply in these load characteristic, inverter systems of constant current regulate is used widely control of lighting and electric heating system. Therefore, in this paper proposed an inverter systems with constant current regulation and power factor correction (PFC) circuit for Lighting and Beaconing of Aerodromes. The effectiveness of the proposed system confirmed through experimental results of CCR.

  • PDF

Study of High Efficiency LLC Resonant Converter for a Battery Charger of Emergency Electric Power Generator Control System (비상용 발전기 제어시스템의 배터리 충전기를 위한 고효율 LLC 공진형 컨버터의 연구)

  • Lee, Joonmin;Park, Min-Gi;Lee, Young Keun;La, Jae-Du
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.10
    • /
    • pp.93-100
    • /
    • 2013
  • Generally, the conventional battery charging system using an analog method has the large, heavy hardware and low efficiency. Also, it has the disadvantage that it is necessary to replace the control circuit on the basis of the characteristic curve of the specific battery cell. The proposed programmable digital LLC resonant charging system use high efficiency control system(CC-CV), and has characteristic a small hardware and advantage that a digital programming of the voltage, current, and battery capacity characteristics can be flexible. The system proposed the use of Half-bridge LLC resonant converter is possible to improve efficiency and reduce switching losses by using ZVS topology. Further, a constant voltage - constant current(CC-CV) control algorithm apply to the charger which using a buck converter. The performance of the proposed system is demonstrated through experiments.

A Study on the Quantatitive Voltage Stability Index Considering Load Voltage Characteristics (부하의 전압특성을 고려한 정량적 전압안정성 지표에 관한 연구)

  • Jeong, Joon-Mo;Lee, Bong-Yong;Kim, Jung-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.3-5
    • /
    • 1994
  • It is shown that the power flow considering the voltage characteristic of the composite load has some difference comparing with conventional load flow in this paper. When the load flow is used in a study of the static voltage stability, it is necessary to consider the voltage characteristic of load, since the composite load of a typical power system bas constant power, constant current, and constant impedance characteristic. The load is modeled to a polynomial form in here, and used in solving the load flow problem. In this way, the effect which the voltage characteristic of the load has on several voltage collapse proximity indicator based on sensitivities is compared with the conventional load flow, or with another load model having a different voltage characteristic. In this paper, the voltage collapse proximity indicator using the sensitivity of real power for transmission loss is also proposed, and compared with other indicators.

  • PDF

REPRESENTATIONS OF SOLUTIONS TO PERIODIC CONTINUOUS LINEAR SYSTEM AND DISCRETE LINEAR SYSTEM

  • Kim, Dohan;Shin, Jong Son
    • Bulletin of the Korean Mathematical Society
    • /
    • v.51 no.4
    • /
    • pp.933-942
    • /
    • 2014
  • We give a representation of the component of solutions with characteristic multiplier 1 in a periodic linear inhomogeneous continuous system. It follows from this representation that asymptotic behaviors of the component of solutions to the system and to its associated homogeneous system are quite different, though they are similar in the case where the characteristic multiplier is not 1. Moreover, the representation is applicable to linear discrete systems with constant coefficients.

A Power Supply System for Lighting of Aerodromes by Using Power Factor Correction and Constant Current Regulator (PFC 및 CCR에 의한 항공조명용 전원공급장치의 개발)

  • Shon, Jin-Geun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2150-2156
    • /
    • 2007
  • According as level of industry develops day after day, electricity load system of industry requires high level control, effectiveness and high efficiency. Among supply and control unit of suitable power supply in these load characteristic, inverter systems of constant current regulate is used widely control of lighting and electric heating system. But, problems that power factor deterioration and fast response of control, efficiency, harmonics and etc are still remain. Therefore, in this paper proposed an inverter systems with constant current regulation and power factor correction (PFC) circuit for lighting and beaconing of aerodromes. The effectiveness of the proposed system confirmed through experimental results of 10[kW] power supply system.

Characteristic Tests on the Gas Turbine Generator System for Determination and Verification of Model Parameters in a Combined Cycle Power Plant (복합화력발전소 가스터빈 발전기계통 모델정수 도출 및 검증을 위한 특성시험)

  • Kim, Jong Goo;Yoo, Hoseon
    • Plant Journal
    • /
    • v.17 no.4
    • /
    • pp.35-40
    • /
    • 2021
  • In this study, a technical characteristic test was conducted on the gas turbine generator system of Seoincheon Combined cycle no.6 to derive and verify the model constants. As a result of the generator maximum/minimum reactive power limit test, the maximum reactive power limit is 80 MVar and the minimum is -30 MVar. The generator uses the GENROU model, the field time constant (T'do) is 4.077 s, and the inertial constant (H) is 5.461 P.U. Excitation system used ESST4B model to derive and verify model constants by simulating no-load 2% AVR step test, PSS modeling derived from PSS2A model constants, and simulated and compared measurement data measured when PSS off/on Did. The GGOV1 model was used for the governor-turbine, and the numerical stability of the determined governor-turbine model constant was verified by simulating a 10% governor step test through the PSS/E simulation program

Inverter Systems of Constant Current Regulate by Using Advanced Measurement and Switching Techniques (개선된 계측 및 스위칭 기법을 이용한 정전류조정 인버터 시스템)

  • Shon, Jin-Geun;Seo, Il-Dong;Jeon, Hee-Jong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.4
    • /
    • pp.173-178
    • /
    • 2007
  • As development of industry is accelerated, most electricity load system requires power supply that could be high precision and effective control. Among supply and control unit of suitable power supply in these load characteristic, inverter systems of constant current regulate is used widely control of lighting & beaconing of aerodromes and electric heating system. Therefore, in this paper proposed a inverter systems of constant current regulate that using improved measurement and switching techniques. Proposed measure techniques that used moving average method of instantaneous r.m.s. for measuring current sensing improved response and precision. Also, in this paper proposed improved high effectiveness switching techniques that get high efficiency of inverter by the double-carrier modulation. Results of an experiment proved effect of proposed system.

Analysis of AT Feeding System using Constant Power Model for Train (정전력 열차 모델을 이용한 AT급전 시스템 해석)

  • Kim B.
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1327-1331
    • /
    • 2004
  • In this paper constant power models for electric trains have been used to analyze the steady states of the AT feeding systems. There are some previous studies utilizing constant impedance models or constant current models. These mentioned models are easy to use, but even so they don't yield exact results because of the innate restraints of the models since linear models cannot represent the characteristic of constant power in inverter-driven trains. It is reasonable that the train be considered as a constant load model when it drives or as a constant source model when it applies regenerative brake. Nonlinear equations which reflect constant power model for train have been developed by considering mutual impedances between wires and AT's turn-ratio of 1:1, then these equations have been solved by N-R iterative method. The proposed method doesn't need any specific assumptions through either the process of developing equations or the process of acquiring solutions, so it can be said to be stricter than other conventional methods.

  • PDF

Characterisic Experiment of Tilting Check Valve for Nuclear Power Plant(II) (원자력 발전소용 Tilting Check Valve의 특성실험 (II))

  • Yeom, Man-O
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.6
    • /
    • pp.803-812
    • /
    • 1998
  • In this study, testing equipment with which several kinds of valves can be tested was composed. Two kinds of tilting check valves and a swing check valve were tested to analyze their dynamic characteristics. The results of the experiment showed that the tilting check valves protected the pump but that the swing check valve could not protect the pump when the reverse flow rate was high. Also the dynamic equation of the tilting check valve was formulated and simulated using system characteristic constant t$_{c}$ and one method of predicting t$_{c}$ by comparing the results of the simulation with the results of the experiment was proposed.sed.

To Determine the Characteristic Polynomial Coefficients Based On the Transient Response

  • Haeri, Mohammad;Tavazoei, Mohammad Saleh
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.11-15
    • /
    • 2005
  • This paper presents a method to determine the characteristic polynomial of a closed loop all-pole system in order to obtain desired transient response in terms of the overshoot and speed (rising/settling time). The method adjusts the overshoot by doing some changes in the characteristic ratios of the Bessel-Thompson filter. The closed loop speediness is then tuned by suitable choice of the generalized time constant. Simulation results are presented to evaluate the achievements and make comparison with those of a similar method.

  • PDF