• Title/Summary/Keyword: Syringe

Search Result 359, Processing Time 0.029 seconds

A Comparison of the Rates of Hemolysis and Repeated Blood Sampling using Syringe needles versus Vacuum tube needles in the Emergency Department (응급실에서의 주사기 채혈과 진공관 채혈의 용혈과 재채혈 비교)

  • Sung, Young-Hee;Hwang, Moon-Sook;Lee, Jee-Hyang;Park, Hyung-Doo;Ryu, Kwang-Hyun;Cho, Myung-Sook;Yi, Young-Hee;Song, S.
    • Journal of Korean Academy of Nursing
    • /
    • v.42 no.3
    • /
    • pp.443-451
    • /
    • 2012
  • Purpose: This study was done to compare the rates of hemolysis and repeated sampling in blood samples obtained by a syringe needle versus a vacuum tube needle. Methods: A randomized, prospective study was used to evaluate the differences between the two blood sampling methods. The study group consisted of patients seen in the emergency department (ED) for blood sampling to determine electrolyte level. ED patients were randomly assigned to either the syringe group or the vacuum tube group. All blood samples were collected by experienced ED nurses and hemolysis was determined by experienced laboratory technologists. Data were analyzed using Fisher's exact test and binary logistic regression. Results: One hundred forty-five valid samples were collected (74 in the syringe group versus 71 in the vacuum tube group). 5 of 74 (6.8%) blood samples in the syringe group and 8 of 71 (11.3%) in the vacuum tube group hemolyzed. Repeated blood sampling occurred for 2 of 74 (2.7%) and 3 of 71 (4.2%) in each group respectively. There were no significant differences in rates of hemolysis and repeated sampling between two groups (B=1.97, p=.204; B=2.36, p=.345). Conclusion: Venipuncture with syringe needles can be recommended for ED nurses to obtain blood samples.

COMPARISON OF STONE SURFACE POROSITIES CAUSED BY HYDROGEN GAS FROM ADDITION SILICONE IMPRESSION MATERIALS (부가 중합형 실리콘 인상재에서 발생하는 수고 기체가 경석고 표면에 미치는 영향)

  • Yoo, So-Jeong;Lee, Keun-Woo;Kim, Kyeung-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.2
    • /
    • pp.349-362
    • /
    • 1996
  • To determine the factors to affect on stone surface porosities produced from hydrogen gas of additional silicone, both putty and syringe type of 7 commercially different additional silicone impression materials(Blend-A-Scon, Correct VPS, Exaflex, Express, Extrude, Provil, Reprosil) were chosen and NewFujirock(GC) was poured into the impressions of detail-reproducing test block at 1, 15, 30, 45, 60 minutes after the impression materials had set and 4 specimens were made for each pouring time, each type of impression material, and each consisency and So, 280 specimens were made in total. The number of surface porosities of same area($2826 mm^2$) which were typically caused by hydrogen gas using the stereoscope(X 7.5) by two observers. Comparison of putty-syringe type and among the impression materials are tested by Kruscal-Wallis method and Mann-Whitney method(p<0.05). The results are as follows. 1. The number of porosities decreased as the pouring time of stone was delayed on both putty and syringe type of additional silicone materials. 2. The putty type significantly produced more porosities than syringe type except for the group of Reprosil.(p<0.05). 3. In case of putty type, the number of porosities increased as following order. Reprosil / Blend-A-Scon and Provil / Correct VPS and Extrude / Express and Exaflex. 4. In case of syringe type, Blend-A-Scon and Extrude produced no porosity and Exaflex and Provil at 30 minites, but Express produced porosities even at 60 minutes and the most. Additional silicone impression material releases hydrogen gas, and that fact can make the resulting die stone model useless. So, to minimize these adverse effects, it is desirable not to expose putty type of additional silicone on critical impression surface because putty type has a tendency to produce more porosities than syringe type. And it is important to have sufficient time before pouring the stone on impression because porosities produce less as time passes after setting of impression material. Also, there are differences among 7 additional silicone impression materials, so it is desirable to choose adequate brand of additional silicone for good laboratory work.

  • PDF

IN VITRO EVALUATION OF CLEANING EFFICACY OF VARIOUS IRRIGATION METHODS IN MANDIBULAR MOLARS (하악 대구치에서 근관세척방법에 따른 잔사제거효과에 대한 평가)

  • Lee, So-Young;Son, Won-Jun;Lee, Woo-Cheol;Kum, Kee-Yeon;Bae, Kwang-Shik;Baek, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.3
    • /
    • pp.215-222
    • /
    • 2009
  • The aim of this in vitro study was to evaluate the cleaning efficacy of various irrigation methods in the mandibular mesial roots. The forty five mesial root canals were shaped by Profile .06 instruments to apical size #30 and irrigated with 5ml of 3.5% NaOCl. The teeth were divided into 3 groups and irrigated finally for 1 minute; Group 1: syringe irrigation. Group 2: ultrasonic irrigation. Group 3: RinsEndo irrigation. After histological processing, the cross sections of apical 1, 3, and 5 mm level were examined with an optical microscope. The cleanliness values of canals and isthmuses were calculated and analyzed by Mann-Whitney U test. 1. There were no significant differences in both canal and isthmus cleanliness between syringe irrigation and ultrasonic irrigation except 5 mm level of isthmus. 2. RinsEndo irrigation had significantly higher canal cleanliness values than syringe irrigation at 1 mm and 3 mm levels (p<0.05). Also, RinsEndo irrigation had significantly higher isthmus cleanliness values than syringe irrigation at all levels evaluated (p<0.05). 3. There were no statistical differences in both canal and isthmus cleanliness between ultrasonic irrigation and RinsEndo irrigation except 3 mm level of canal. From this study, RinsEndo irrigation can be useful as an additional irrigation procedure.

Smart syringe pumps for drug infusion during dental intravenous sedation

  • Seo, Kwang-Suk;Lee, Kiyoung
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.16 no.3
    • /
    • pp.165-173
    • /
    • 2016
  • Dentists often sedate patients in order to reduce their dental phobia and stress during dental treatment. Sedatives are administered through various routes such as oral, inhalation, and intravenous routes. Intravenous administration has the advantage of rapid onset of action, predictable duration of action, and easy titration. Typically, midazolam, propofol or dexmedetomidine are used as intravenous sedatives. Administration of these sedatives via infusion by using a syringe pump is more effective and successful than infusing them as a bolus. However, during intravenous infusion of sedatives or opioids using a syringe pump, fatal accidents may occur due to the clinician's carelessness. To prevent such risks, smart syringe pumps have been introduced clinically. They allow clinicians to perform effective sedation by using a computer to control the dose of the drug being infused. To ensure patient safety, various alarm features along with a drug library, which provides drug information and prevents excessive infusion by limiting the dose, have been added to smart pumps. In addition, programmed infusion systems and target-controlled infusion systems have also been developed to enable effective administration of sedatives. Patient-controlled infusion, which allows a patient to control his/her level of sedation through self-infusion, has also been developed. Safer and more successful sedation may be achieved by fully utilizing these new features of the smart pump.

Development of the Dual Mode Syringe Type Infusion Pump (이중모드 주사기형 약물자동주입장치의 개발에 관한 연구)

  • Hong, S.Y.;Um, K.H.;Kim, I.K.;Lee, K.J.;Yoon, H.R.;Kim, U.K.;Um, D.J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.317-318
    • /
    • 1998
  • The purpose of this study is to design and develop the circuit of the dual mode syringe pump. Syringe pump is used in intensive care unit, delivery room, pediatric room, operating theater and other fields of hospital at present. Normally the syringe pump delivers one medicine in one case, but in case of intensive care unit, it is necessary to deliver more than two kinds of medicines at a time. Therefore we have designed dual mode syringe pump. We used RISC type microcontroller, PIC17C44 as master controller, and PIC16C73 as slave cpu using for the low power consumption. The performance of system is evaluated by analysis of the linearity and accuracy which is the most important factors in application. While the proposed system shows a acceptable linearity and accuracy, a further research about reducing the errorr should be done.

  • PDF

The Effect of Bee Venom Therapy on Skin Aging (봉독이 피부 노화에 미치는 영향)

  • Kim, Jin-Myoung;Kim, Yoon-Bum
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.23 no.2
    • /
    • pp.27-40
    • /
    • 2010
  • Background and Objective : Increasing interest in anti-aging and anti-wrinkling agents for the skin has triggered the recent outflow of researches and studies in this field. This study was designed to investigate the effects of bee venom on skin wrinkling and skin aging by testing the skin wrinkling, skin elasticity, trans-epidermal water loss (TEWL), free radical level, anti-oxidative agent level, and skin tissue after infusion of bee venom on hairless mouse. Materials and Methods : Fifteen hairless mice aged between 36~40 weeks were divided randomly into 3 Group; the Bee Venom Syringe Group, the Bee Venom Needle Group, and the control group. The Bee Venom Syringe Group were injected subcutaneously with bee venom (0.1cc in total) using an insulin syringe on three spots in the lumbar spine (one spot on the center and two spots 1~2cm to the side bilaterally). The Bee Venom Needle Group were pricked with bee venom-smeared acupuncture needles on three longitudinal spots in the lumbar spine each 1cm apart, after which the needles were removed 10 minutes later. The Control Group did not receive any form of intervention. All procedures took place thrice a week for four weeks, during which the mice were allowed free access to water and fodder. The mice were measured and compared in the weight, skin wrinkling scale, skin elasticity, and TEWL before and after the experiment. After the experiment, blood samples were taken to measure the free radical and anti-oxidative agent level, and the skin tissue was sliced for examination. Data was analyzed using the SPSS program (ver 12.0). The ANOVA analysis was used to compare and contrast the three groups, and t-test for paired samples was used to evaluate skin-wrinkling before and after experiment. The cut-off p-value of significance was set at p<0.05. Results : 1. Administration of bee venom did not cause serious weight loss or gain. 2. Compared to the control group, the Bee Venom Syringe Group and the Bee Venom Needle Group both showed a decrease in skin wrinkling scale after intervention. Especially, the Bee Venom Syringe Group showed a significant decrease (p<0.05). 3. Compared to the control group, the Bee Venom Syringe Group and the Bee Venom Needle Group both showed an increase in skin elasticity. Especially, the Bee Venom Syringe Group showed a significant increase (p<0.05). 4. No significant change in TEWL was found in the mice in all the three groups before and after experiment. 5. Free radical level was normal in all 15 mice in all the three groups, and anti-oxidative agent was not significantly different across the three groups. 6. The Bee Venom Syringe Group, the Bee Venom Needle Group, and the control group did not show any significant difference in the thickness of epidermis and dermis, infiltration of inflammatory cells, and skin wrinkling. The epidermis layer was relatively better preserved in the Bee Venom Syringe Group as compared to the Bee Venom Needle Group and the control group. Conclusion : Direct injection of bee venom on the hairless mouse using a syringe was found to improve wrinkling of the skin and increase skin elasticity but did not show effectiveness on skin dryness due to water loss. The bee venom appears to have suppressive effects on skin wrinkling, one of the symptoms of skin aging, through a process independent of suppression of free radicals or increase of anti-oxidative agent.

Normative data of penile length in Korean newborns (한국인 신생아 음경 길이에 대한 연구)

  • Kim, Sang Yeob;Jun, Jae Sung;Lee, Sang Geel
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.9
    • /
    • pp.944-949
    • /
    • 2008
  • Purpose : As modern society has became more open, interest in healthy internal and external growth has increased, including that pertaining to penile length in children. A micropenis is defined as one where penile length is more than 2 SD (standard deviation) below the mean, and it can be traced back to chromosome and endocrine disorders. The authors executed this study to suggest guidelines for the study of the micropenis and standard information for penile length in Korean newborns. Methods : The subjects of this study were 168 male infants between 37 and 42 weeks of gestational age, none of whom had any complications during pregnancy or birth; each had been born in Daegu Fatima Hospital between February and June 2007. Penile length was measured using conventional stretched penile length measurement (CPLM) and syringe methods. Results : Penile length was $3.02{\pm}0.25cm$ (F=36.467, $R^2=0.180$, P<0.001) when measured with CPLM, and $3.29{\pm}0.26cm$ (F=9.149, $R^2=0.052$, P<0.001) with the syringe method. There was no statistically significant difference in the penile length of newborn infants as a result of taking measurements with the two methods, and both methods showed significance at 0.631 in terms of Pearson's correlation coefficient, at the level of P=0.01. Conclusion : In this study, penile length tended to be longer when gestational age was longer, and a micropenis can be assumed to be one less than 2.5 cm using CPLM and less than 2.8 cm using the syringe method. In the case of a concealed penis, the syringe method is helpful. When a micropenis is assumed, close observation by outpatient department personnel, and additional endocrine and chromosome studies should be undertaken after sufficiently consulting the parents.

A Study on the Implementation of a Remote Medicines Injection System For u-Hospital (u-Hospital 을 위 한 원 격 약물 주사 제어 시스템의 구현의 관한 연구)

  • Lim, Su-Young;Heo, Jung-Il;Seo, Jung-Ho;Ahn, Jin-Soo;Kim, Woo-Shik
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.376-380
    • /
    • 2007
  • This paper suggests remote injection system and explains the design of the system and means of implementation. Remote injection system means a system delivering the precise injection prescribed to the patient in the ward through input into the remote server using TCP/IP protocol. The system has been planned in detail. The syringe has been designed to be linked with the Ringer's rubber tube and the independently developed syringe-module is to be used in order to ensure precise and accurate delivery of the injected medication. In development stage of embedded software, object-oriented planning method has been chosen.

  • PDF

A Study on the Mixing of Pulverization Matters when the Contrast Medium is connected to the Automatic Injection Device using the Syringe Connector (Syringe Connector를 이용하여 조영제를 자동 주입장치에 연결 시 분쇄물 혼입에 관한 연구)

  • Kim, Hyeon ju;Kim, Ji eun;Han, Yu bean;Choi, Seung hyun;Kang, Yun ki;Jung, Yu jin;Jung, Min young;Lee, Hoo min
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.777-783
    • /
    • 2018
  • The purpose of this study was to investigate the degree of tearing of the rubber when the spike of the syringe connector was connected to the bottle of the contrast medium composed of the rubber compound type and to investigate the presence of the synthetic rubber due to tearing and grinding and the size of the pulverized product when the pulverized matters rubber was detected. As a result, in the case of tearing degree, the front side of the first contact with the end of the syringe connector was torn more than the back side by about $3.14{\pm}0.04mm$, and the pulverized matters was detected on average 7 to 15 on the 10 contrast mediums. The average particle size was measured to be about $7.89{\pm}0.31{\mu}m$. In addition, it is necessary to develop a micro_filter type automatic injection system for blocking off the pulverized matters as well as additional experiments through various experiments and analysis methods, and it is considered that interest of related organizations will be needed in preparation of fatal accidents when pulverized matters is introduced.

The survey on the infection control of noncritical instruments used in dental treatment (치과 치료에 사용되는 비위험 기구의 감염 관리 실태 조사)

  • Kim, Jae Hyun;Lee, Jin-Han
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.1
    • /
    • pp.27-36
    • /
    • 2019
  • Purpose: The aims of this study were to evaluate the dentist's awareness and the actual status of infection control of noncritical dental instruments. Materials and Methods: 40 dental clinics in Daejeon, South Chungcheong, North Chungcheong and North Jeolla provinces were surveyed. The questionnaire was delivered to the dentists belonging to those clinics, and the awareness and the practice of infection control were examined. The microbial contamination on the surface of five noncritical instruments (impression gun, light curing unit, 3-way syringe, shade guide, and dental floss dispenser) used by them was measured with an ATP luminometer. Correlation analysis between the awareness and the actual state of infection control was conducted. Results: Awareness and frequency of infection control was highest in the 3-way syringe. Surface disinfection using disinfectant was most frequent in all instruments. 3-way syringes and shade guides were less contaminated than impression guns, light curing units, and dental floss dispensers. Conclusion: 3-way syringes had a significant correlation between user awareness of infection control and surface contamination, and the higher awareness, the lower the contamination measurement was shown.