• 제목/요약/키워드: Symmetric and asymmetric structures

검색결과 68건 처리시간 0.029초

지진하중에 대한 다경간 교량의 비탄성 변위응답 평가 (Evaluation of Inelastic Displacement Response for Multi-Span Bridge Structures Subjected to Earthquakes)

  • 송종걸;남왕현;정영화
    • 산업기술연구
    • /
    • 제24권A호
    • /
    • pp.195-204
    • /
    • 2004
  • To evaluate inelastic seismic responses of multi-span bridge structures, the capacity spectrum method(CSM) incorporating the equivalent single-degree-of freedom(ESDOF) method is presented. Application of the CSM incorporating the ESDOF method is illustrated by example analysis for symmetric and asymmetric bridge structures. To investigate an accuracy of the CSM, the maximum displacements estimated by the CSM are compared to those by inelastic time history analysis for several artificial earthquakes. The results show that the CSM provided conservative estimates of the maximum displacements for the symmetric and asymmetric bridge structures, and the trend of conservative estimates of the asymmetric bridge structures was significantly larger than that of the symmetric bridge structure.

  • PDF

점성 감쇠기를 이용한 인접 비대칭 강성 구조물의 내진보강 최적설계 (Optimal Seismic Reinforcement Design of Adjacent Asymmetric-Stiffness Structures with Viscous Dampers)

  • 성은희
    • 한국안전학회지
    • /
    • 제37권6호
    • /
    • pp.60-70
    • /
    • 2022
  • This paper proposes an optimal design method of a seismic reinforcement system for the seismic performance of adjacent asymmetric-stiffness structures with viscous dampers. The first method considers plan asymmetry for efficient seismic reinforcement, and evaluates the seismic performance of optimal design applied to two cases of modeling: adjacent stiffness-asymmetric structures and adjacent stiffness-symmetric structures. The second method considers the response of asymmetric structures to derive the optimal objective function, and evaluates seismic efficiency of the objective function applied to two cases of responses: horizontal displacement and torsion. Numerical analyses are conducted on 7- and 10-story structures with a uni-asymmetric-stiffness plan using six cases of historic earthquakes, normalized to 0.4g. The results indicate that the seismic performance is excellent as modeled by adjacent asymmetric-stiffness structures and how much horizontal displacement is applied as the objective function.

Effect of rigid connection to an asymmetric building on the random seismic response

  • Taleshian, Hamed Ahmadi;Roshan, Alireza Mirzagoltabar;Amiri, Javad Vaseghi
    • Coupled systems mechanics
    • /
    • 제9권2호
    • /
    • pp.183-200
    • /
    • 2020
  • Connection of adjacent buildings with stiff links is an efficient approach for seismic pounding mitigation. However, use of highly rigid links might alter the torsional response in asymmetric plans and although this was mentioned in the literature, no quantitative study has been done before to investigate the condition numerically. In this paper, the effect of rigid coupling on the elastic lateral-torsional response of two adjacent one-story column-type buildings has been studied by comparison to uncoupled structures. Three cases are considered, including two similar asymmetric structures, two adjacent asymmetric structures with different dynamic properties and a symmetric system adjacent to an adjacent asymmetric one. After an acceptable validation against the actual earthquake, the traditional random vibration method has been utilized for dynamic analysis under Ideal white noise input. Results demonstrate that rigid coupling may increase or decrease the rotational response, depending on eccentricities, torsional-to-lateral stiffness ratios and relative uncoupled lateral stiffness of adjacent buildings. Results are also discussed for the case of using identical cross section for all columns supporting eachplan. In contrast to symmetric systems, base shear increase in the stiffer building may be avoided when the buildings lateral stiffness ratio is less than 2. However, the eccentricity increases the rotation of the plans for high rotational stiffness of the buildings.

The influence of nonlinear damping on the response of a piezoelectric cantilever sensor in a symmetric or asymmetric configuration

  • Habib, Giuseppe;Fainshtein, Emanuel;Wolf, Kai-Dietrich;Gottlieb, Oded
    • Smart Structures and Systems
    • /
    • 제30권3호
    • /
    • pp.239-243
    • /
    • 2022
  • We investigate the influence of nonlinear viscoelastic damping on the response of a cantilever sensor covered by piezoelectric layers in a symmetric or asymmetric configuration. We formulate an initial-boundary-value problem which consistently incorporates both geometric and material nonlinearities including the effect of viscoelastic damping which cannot be ignored for micro- and nano-mechanical sensor operation in a vacuum environment. We employ an asymptotic multiple-scales methodology to yield the system nonlinear frequency response near its primary resonance and employ a model-based estimation procedure to deduce the system damping backone curve from controlled experiments in vacuum. We discuss the effect of nonlinear damping on sensor applications for scanning probe microscopy.

2심 냉간성형 각형 CFT기둥-보 접합부의 구조거동 (Structural Behavior of Two-Seam Cold Formed Square CFT Column to Beam Connections)

  • 오헌근;김선희;박찬면;최성모
    • 한국공간구조학회논문집
    • /
    • 제12권4호
    • /
    • pp.81-90
    • /
    • 2012
  • The concrete-filled tube (CFT) column has the excellent structural performance. But it is difficult to connect with column and beam because of closed section. Its Solution, 2 members of ㄷchennel in which Internal diaphragm is installed were welded beforehand and the method of making Rectangular Steel Tube was proposed. According to upside and downside junction shape, Internal diaphragm suggested as symmetric specimen and asymmetric specimen. The upper and lower diaphragm of the Symmetric specimen used the same horizontal and The upper diaphragm of the Asymmetric specimen used the horizontal plate and the lower diaphragm used the vertically plate. In this research, 4 T-shape column to beam steps connections were tested with cyclic loading experiment in order to evaluate the structural capability of the offered connection. Symmetric specimens be a failure in 0.03rad from beam flange. And Asymmetric specimens be a failure in 0.05rad from column interface. The comparison results of All specimens shown similar to energy absorption capacity in 0.02rad.

직육면체를 지나는 층류 유동 (LAMINAR FLOW OVER A CUBOID)

  • 김동주
    • 한국전산유체공학회지
    • /
    • 제13권1호
    • /
    • pp.57-62
    • /
    • 2008
  • Laminar flows over a cube and a cuboid (cube extended in the streamwise direction) are numerically investigated for the Reynolds numbers between 50 and 350. First, vortical structures behind a cube and lift characteristics are scrutinized in order to understand the variation in vortex shedding characteristics with respect to the Reynolds number. As the Reynolds number increases, the flow over a cube experiences the steady planar-symmetric, unsteady planar-symmetric, and unsteady asymmetric flows. Similar to the sphere wake, the planar-symmetric flow over a cube can be divided into two different regimes: single-frequency regime and multiple-frequency regime. The former has a single frequency due to regular shedding of vortices with the same strength in time, while the latter has multiple frequency components due to temporal variation in the strength of shed vortices. Second, the effect of the length-to-height ratio of the cuboid on the flow characteristics is investigated for the Reynolds number of 270, at which planar-symmetric vortex shedding takes place behind a cube. With the ratio smaller than one, the flow over the cuboid becomes unsteady asymmetric flow, whereas it becomes steady flow for the ratios greater than one. With increasing the ratio, the drag coefficient first decreases and then increases. This feature is related to the flow reattachment on the side faces of the cuboid.

Symmetric and Asymmetric Properties in Korean Verbal Coordination: A Computational Implementation

  • Kim, Jong-Bok;Yang, Jae-Hyung
    • 한국언어정보학회지:언어와정보
    • /
    • 제15권2호
    • /
    • pp.1-21
    • /
    • 2011
  • Of the coordination structures in Korean, the symmetric and asymmetric properties of verbal coordination have challenged both theoretical and computational approaches. This paper shows how a typed feature structure grammar, HPSG, together with the notions of 'type hierarchy' and 'constructions', can provide a robust basis for parsing (un)tensed verbal coordination as well as pseudo-coordination found in the language. We show that the analysis sketched here and computationally implemented in the existing resource grammar for Korean, Korean Resource Grammar (KRG), can yield proper syntactic structures as well as enriched semantic representations for real-time applications such as machine translation.

  • PDF

불규칙한 소오스/드레인 금속 접촉을 갖는 비대칭 n-MOSFET의 전기적 특성 및 모델 (Electrical Characteristics and Models for Asymmetric n-MOSFET′s with Irregular Source/Drain Contacts)

  • 공동욱;정환희;이재성;이용현
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 추계종합학술대회 논문집
    • /
    • pp.208-211
    • /
    • 1999
  • Abstract - Electrical characteristics or asymmetric n-MOSFET's with different source and drain geometry are experimently investigated using test structures having various gate width. Saturation drain current and resistance in linear region are estimated by a simple schematic model, which consists of conventional device having parasitic resistor. A comparison of experimental results of symmetric and asymmetric devices gives the parasitic resistance caused by abnormal device structure. The suggested model shows good agreement with the measured drain current for both forward- and reverse-modes.

  • PDF

비대칭(非對稱) 단면(斷面) 보강재(補剛材)의 강도해석(强度解析) (On the Strength Analysis of the Stiffener with Asymmetric Cross Section)

  • 임상전;양영순;이규성
    • 대한조선학회지
    • /
    • 제17권1호
    • /
    • pp.11-18
    • /
    • 1980
  • In the conventional ship's structures, the stiffeners with asymmetric sections have been widely used, in spite of the disadvantage on the point of strength, compared to those with symmetric sections. So far, the stiffened plating was usually analyzed not considering the geometric unsymmetry characteristics of the section, including only the cross sectional area and moment of inertia. In this paper, the stiffened plating is devided into the strips having a thin-walled open cross section by using the concept of the effective width. The geometric characteristics of the sections are also included. The governing equations are derived, which can be applied to the arbitrary cross section beams, and the symmetric and the asymmetric section beams which have the same cross sectional areas are analyzed by using the finite element method. From that result, we obtain the allowable load of the two sections, and compared them.

  • PDF

AC PDP의 효율 향상을 위한 비대칭형 금속전극구조 (Improvement of Luminous Efficacy in AC PDP with Asymmetric Metal Electrode Structure)

  • 동은주;옥정우;윤초롬;이해준;이호준;박정후
    • 전기학회논문지
    • /
    • 제57권4호
    • /
    • pp.660-667
    • /
    • 2008
  • To improve the luminous efficacy of PDPs, an AC PDP with new metal electrode structure is suggested. Operating voltage margin, power consumption, luminance, luminous efficacy, addressing jitter and ICCD image of test panel with proposed structure are measured, to compared with performances of the conventional ITO structure and proposed structures. To enhance luminous efficacy, we designed new structure which have asymmetric metal electrode structure. The experimental results show that the suggested structure shows luminance to maximum 89% and luminous efficacy to maximum 107% compared with conventional ITO standard structure. In addition, proposed structures with asymmetric electrode show low power consumption by $2{\sim}3%$, high luminance by $5{\sim}7%$, and high luminous efficacy by $2{\sim}3%$ compared with proposed symmetric electrode structures.