• 제목/요약/키워드: Switch fault

검색결과 186건 처리시간 0.034초

멀티 에이전트 개념에 기반한 배전계통의 분산 자율적 고장구간 분리 기법 (Autonomous Separation Methodology of Faulted Section based on Multi-Agent Concepts in Distribution System)

  • 고윤석;홍대승;송완석;박학열
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권6호
    • /
    • pp.227-235
    • /
    • 2006
  • In this paper, autonomous separation methodology of faulted section based on network is proposed newly, which can minimize the outage effect as compared with the existing center-based faulted section separation method by determining and separating autonomously the faulted section by the free operation information exchange among IEDs on the feeder of distribution system. The all IEDs is designed in network in which client/server function is possible in order to separate autonomously the faulted section using PtP(Peer to Peer) communication. Also, Inference based solution of IED for the autonomous faulted section separation is designed by rules obtained from the analyzing results of distribution system topology. Here, the switch IEDs transmit on network the fault information utilizing on multi-casting communication method, at the fame time, determine selfly whether they operates or not by inferencing autonomously the faulted section using the inference-based solution after receiving the transmitted information. Finally, in order to verify the effectiveness and application possibility of the proposed methodology, the diversity fault cases are simulated for the typical distribution system.

국내 배전계통의 최적 개폐기 설치 기준(I) (The optimized standards and criteria for installing switches on distribution feeder)

  • 조남훈;오재형;이흥호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.70-73
    • /
    • 2002
  • Utilities are trying to install the equipment of high quality to avoid deterioration of supply reliability. In addition, many sectionalizing switches which can decrease the total outage value for a fault are installed for the same reason. Therefore, utilities are interested in standards and criteria for installing switches to optimize the total cost on distribution systems. The affect of sectionalizing switches installed on distribution feeder is gradually decreased because the failure rate on distribution feeder is decreased. Also the automation for distribution systems is widely applied for the efficient operation. Therefore, the renewal for installation standards of sectionalizing switches is required to reflect the current operation situation. The variable data is used to consider the KEPCO's real situation of distribution feeder as follows; the feeder capacity, connecting rate, feeder length, failure rate of distribution feeder, the failure rate of switches, perception time of feeder fault, the restoration time for a faulted section, the transfer time to other feeders, and the switching time. In this study, We propose equations which can determine the number of sectionalizing switches for minimizing the outage and switch installation cost.

  • PDF

Efficient Management of PCM-based Swap Systems with a Small Page Size

  • Park, Yunjoo;Bahn, Hyokyung
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제15권5호
    • /
    • pp.476-484
    • /
    • 2015
  • Due to the recent advances in non-volatile memory technologies such as PCM, a new memory hierarchy of computer systems is expected to appear. In this paper, we explore the performance of PCM-based swap systems and discuss how this system can be managed efficiently. Specifically, we introduce three management techniques. First, we show that the page fault handling time can be reduced by attaching PCM on DIMM slots, thereby eliminating the software stack overhead of block I/O and the context switch time. Second, we show that it is effective to reduce the page size and turn off the read-ahead option under the PCM swap system where the page fault handling time is sufficiently small. Third, we show that the performance is not degraded even with a small DRAM memory under a PCM swap device; this leads to the reduction of DRAM's energy consumption significantly compared to HDD-based swap systems. We expect that the result of this paper will lead to the transition of the legacy swap system structure of "large memory - slow swap" to a new paradigm of "small memory - fast swap."

배전계통 광역 정전복구 알고리즘 개발 (The Development of Multi-Fault Restoration Algorithm for Distribution Network)

  • 정진수;이승재;정종욱;임용배;배석명;이건호
    • 조명전기설비학회논문지
    • /
    • 제20권3호
    • /
    • pp.69-77
    • /
    • 2006
  • 이 논문에서는 배전계통의 정전복구 알고리즘에 대해 연구하였다. 배전계통에서 정전이 발생하였을 경우, 그 피해를 최소화하기 위해 가능한 빠른 시간 내에 정전복구가 완료되어야 한다. 따라서, 본 논문에서는 광범위한 영역에 걸친 정전구간을 신속하게 복구하기 위한 2가지 방법을 연구하였다. 하나의 방안은 개별정전복구방안이며, 다른 하나는 종합정전복구방안이다. 이 방안은 복구지수를 이용하여 정전구간을 복구하는 것을 도와준다. 또한 연계점 교환법을 이용하여 과부하구간을 해소함으로써 정전복구에 일조하게 된다.

하이브리드 방식을 적용한 배전급 초전도 한류기 개발 (Hybrid Superconducting Fault Current Limiters for Distribution Electric Networks)

  • 이방욱;박권배;심정욱;오일성;임성우;김혜림;현옥배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.102-103
    • /
    • 2007
  • In order to apply resistive superconducting fault current limiters into electric power systems, the urgent issues to be settled are as follows, such as initial installation price of SFCL, operation and maintenance cost due to ac loss of superconductor and the life of cryostat, and high voltage and high current problems. The ac loss and high cost of superconductor and cryostat system are main bottlenecks for real application. Furthermore in order to increase voltage and current ratings of SFCL, a lot of superconductor components should be connected in series and parallel which resulted in extreme high cost. Thus, in order to make practical SFCL, we designed novel hybrid SFCL which combines superconductor and conventional electric equipment including vacuum interrupter, power fuse and current limiting reactor. The main purpose of hybrid SFCL is to drastically reduce total usage of superconductor by adopting current commutation method by use of superconductor and high fast switch. Consequently, it was possible to get the satisfactory test results using this method, and further works for practical applications are in the process.

  • PDF

반사필터를 이용한 광선로 원격감시 시스템 (Optical Line Remote-Monitoring System Using Reflecting Filter)

  • 정소기;차경천
    • 한국통신학회논문지
    • /
    • 제39A권6호
    • /
    • pp.357-364
    • /
    • 2014
  • 본 논문은 반사필터를 사용하여 FTTH-PON의 원격제어 시스템을 다루고 있다. 기존의 FTTH-PON방식은 광케이블 고장과 수동분기소자(Splitter)의 품질 저하가 발생하는 것을 실시간 인지 할 수 없다. 본 연구에서는 이를 해결하기 위해서 광섬유 브래그 격자 원리를 이용한 반사필터를 개발하여 간선망과 Splitter를 감시 할 수 있게 하였다. 반사필터는 광케이블 밴딩, 커넥터 상태와 스플리터의 품질이 점진적으로 저하되는 것을 모니터링 하고 광케이블 고장, 수동 광분배기(Splitter) 등의 고장 위치를 확인하여 OLT측에 경보를 보내서 중앙관제에서 감시할 수 있는 시스템이다. 즉, 기존 통신 국사 측 파장분기 결합부(Coupler)를 이용해 1개의 광심선으로 live 파장과 감시용 파장을 2개로 보내어 가입자 측 장치인 모뎀과 집선 스위치에 반사필터를 사용하여 원격으로 광선로를 감시하는 시스템에 관한 연구이다. 이러한 반사필터의 개발로 인해 광선로 평균 고장처리 시간 단축과 효율적 유지보수를 할 수 있을 것으로 기대한다.

초전도소자의 트리거를 이용한 초전도 전류제한기의 전류제한 및 회복특성 분석 (Analysis on Current Limiting and Recovery Characteristics of a SFCL using a Trigger of Superconducting Element)

  • 임성훈
    • 조명전기설비학회논문지
    • /
    • 제24권1호
    • /
    • pp.112-116
    • /
    • 2010
  • 본 논문에서는 고장발생 초기에 초전도 전류제한기를 구성하는 초전도 소자의 ��치발생을 검출하여 고장전류의 경로를 별도의 상전도 전류제한기로 우회시킴으로써 초전도 전류제한기의 회복시간을 단축시킬 수 있는 초전도소자의 트리거를 이용한 초전도 전류제한기의 전류제한 및 회복특성에 대해 분석하였다. 고장전류 크기를 조절하기 용이한 구성요소로 상전도 전류제한기의 저항크기에 따른 초전도 전류제한기를 구성하고 있는 전력용스위치의 개방시점과 투입시점의 변화를 비교하였으며, 분석을 통해 상전도 전류 제한기의 저항이 증가할수록 초전도 전류제한기를 구성하는 전력용스위치의 복귀시간이 길게 나타남을 확인할 수 있었다.

스마트 센서를 이용한 선박용 승강기 실시간 모니터링 시스템의 구현 (Implementation of Real-time Monitoring System for Marine Elevator using Smart Sensors)

  • 이우진;임재홍
    • 한국멀티미디어학회논문지
    • /
    • 제19권2호
    • /
    • pp.405-410
    • /
    • 2016
  • Elevator industry is a field that is mechanical, electrical and electronic technology and constantly requires inspection and maintenance considering various applications and various types. Recently, various elevator control and monitoring technologies with IT are developing for elevators on land. But technologies with IT have been hardly done in marine elevator that is consistently assured safety and reliability of life cycle for its parts in poor environment. In this paper, we implemented embedded main controller, floor controller and car controller that meet the requirements and use NMEA network protocol by analyzing home and abroad integrated elevator operation and management systems. Especially, we secured reliability of maintenance by real-time fault diagnosis and control that was implemented with limit switch, gyro sensor, temperature/humidity/barometric pressure sensor and fire detection sensor thinking over the environmental conditions of terrestrial and marine elevator.

3상 PWM 정류기의 스위치 개방 고장시 감지 및 허용운전 방법 (Switch Open Fault Detection and Tolerant Method for Three Phase PWM Rectifier)

  • 신희근;안병웅;김학원;조관열;임병국;정신명
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 추계학술대회
    • /
    • pp.18-19
    • /
    • 2011
  • 본 논문에서는 3상 PWM 정류기의 스위치 개방 고장시 감지 및 허용 운전 방법에 대해 제안한다. 스위치의 개방 고장이 발생 하면, 한상의 전류가 반주기 동안 나타나지 않기 때문에 출력 직류전압의 리플로 나타나게 된다. 이경우 고장 감지 및 허용 운전을 하지 않으면, 전력 품질을 저하되며, 직류 링크 콘덴서의 수명이 감축되는 문제를 발생 시킨다. 제안된 기법은 추가적인 하드웨어 없이 간단한 모델 적응 제어 (Model Reference Adaptive System)을 이용하여, 고장된 스위치를 감지 하며, 고장난 스위치의 반대 스위치를 켜고 나머지 2상을 전류제어 하여 3상 전류를 평형상태로 만들어 출력 직류전압의 리플을 줄이는 허용운전을 제안한다. 본 논문은 6kW급 3상 PWM 정류기 시스템을 모의해석을 통해 제안된 기법의 타당성을 입증 하였다.

  • PDF

Short-circuit Protection for the Series-Connected Switches in High Voltage Applications

  • Tu Vo, Nguyen Qui;Choi, Hyun-Chul;Lee, Chang-Hee
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1298-1305
    • /
    • 2016
  • This paper presents the development of a short-circuit protection mechanism on a high voltage switch (HVS) board which is built by a series connection of semiconductor switches. The HVS board is able to quickly detect and limit the peak fault current before the signal board triggers off a gate signal. Voltage clamping techniques are used to safely turn off the short-circuit current and to prevent overvoltage of the series-connected switches. The selection method of the main devices and the development of the HVS board are described in detail. Experimental results have demonstrated that the HVS board is capable of withstanding a short-circuit current at a rated voltage of 10kV without a di/dt slowing down inductor. The corresponding short-circuit current is restricted to 125 A within 100 ns and can safely turn off within 120 ns.